| 1 | Shifting & Conversion of HT Overhead lines to Underground Cable |
| 2 | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 3 | Supplying and erecting rolled steel joist (girder) pole 152 x 152 mm (37.1 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 4 | Making Cement concrete foundation including excavation (60 x 60)cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45cm x 45cm x 45cm/ 45cm dia. x 45cm height plinth duly plastered, with necessary curing and finishing complete. (for above 9m poles) |
| 5 | Supplying, installing and testing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.I. cover complete with all accessories of G.I. materials & recording the results as per specification no. EA-EP |
| 6 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 7 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP. |
| 8 | Supplying and erecting anti climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete. |
| 9 | Supplying and erecting extra thick alkathene pipe 10 mm dia. erected to enclose bare conductor wires complete.. (use shall be restricted to H.T.) |
| 10 | Supplying and erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394.00 kg/km) as per specification No. OH-CON/ACSR |
| 11 | Supplying and erecting polymer disc type insulator 70KN with necessary hardware suitable for 33kV line complete as per specification no. OH-INS/DI |
| 12 | Supplying and erecting polymer pin type insulator with GI pin suitable for 33kV line, complete as per specification no. OH-INS/PN |
| 13 | Supplying and erecting iron work, sheet metal work consisting of MS sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer. |
| 14 | Supplying, erecting, testing & commisioning GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in marathi and hindi erected at position for HV/EHV (11000 Volts) erecting with compliance to IS 2551-1982. as per specification no. CP/SH/CR |
| 15 | Supplying erecting 33 KV Isolators for HT Line without EB (800 Amp.) with required accessories etc. |
| 16 | Supplying & laying (including excavation) reinforced cement concrete pipe of NP-2 class of 150 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 17 | Supplying & laying (including excavation) half round reinforced cement concrete pipe of NP-2 class of 150 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 18 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 19 | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. |
| 20 | Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. |
| 21 | Dismantling the existing lightening arrestor set, insulator from DP structure complete. |
| 22 | PVC armoured/unarmoured cables and wires (Aluminium) |
| 23 | H.G. / M.S. / G.I. Materials / Poles etc. |
| 24 | Providing and erecting Heat shrinkable outdoor termination kit for 33 kV ( E )/33 kV (UE) XLPE HT cable 3x300 sq. mm. to 400 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 25 | Providing and erecting Heat shrinkable straight through joint kit for 33 kV ( E )/33 kV (UE) XLPE HT cable 3x300 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 26 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire round armoured cable 33 kV(UE), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT Please Enable Macros to View BoQ information |