Housing Urban and Rular Development Government Departments Closing in 5 days TDR #56174598

Tender For Construction Of School Education Excellence Education Hub / Samagra Office At Gandhi Nagar Jammu (Under The Central Sponsered Scheme Samagra Shiksha During The Current Financial Year 2025-26).

Issued by Government Departments · Kathua, Jammu and Kashmir
Tender Value
8.46 Crore
Estimated cost
Bid Submission
17 Jul 2026
5 days left
EMD
16.93 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kathua → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of School Education Excellence Education Hub / Samagra Office At Gandhi Nagar Jammu (Under The Central Sponsered Scheme Samagra Shiksha During The Current Financial Year 2025-26).

BOQ

Name of Work:- Construction of School Education Excellence Education Hub / Samagra Office at Gandhi Nagar Jammu (Under the Central Sponsered Scheme Samagra Shiksha during the current financial year 2025-26).
Sl. No. Item Description
1Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil.
2Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil.
3Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material. all kinds of soil.
4Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
5Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
6Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level.
7Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor V level.
8Providing & fixing at or near ground level precast cement concrete in kerbs,, edging etc as per approved patterns and setting in position with cement mortar 1:3(1 cement:3 coarsesand) including the cost of required centring, shuttering and curing complete 1:1½:3(1 cement :1½ coarse sand :3 graded stone aggregate 20 mmnominal size).
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
10Centering and shuttering including strutting, propping etc. and removal of form work for :-
11Foundations, footings, bases of columns etc. for mass concrete.
12Columns, pillars, piers, abutments, posts and struts.
13Lintel, beams, plinth beams, girders, bressumers and cantilevers.
14Suspended floors, roofs, landings, balconies and access platforms.
15Weather shades, chajjas, corbels etc. including edges.
16Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc.
17Stairs (excluding landings) except spiral staircases.
18Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 25mm thick with 12.5 mm nominal size stone aggregate.
19Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete.
20Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7 kg per square meter on damp proof courses after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
21Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in 1.4 Cement mortar 1:4 ( 1 cement : 4 coarse sand).
22Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 (1 cement : 6 coarse sand).
23Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level.
24Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand).
25Extra for half Brick masonry in superstructure above plinth level upto floor V level.
26Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry.
27Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 fine sand) including curing.
286 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand).
2912mm Cement plaster of mix 1 : 6 (1 cement : 6 coarse sand).
3015mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 (1 cement : 6 fine sand).
31Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
32Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
33Making of grove 12mm x 10mm between brick and RCC.
34Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete.
35Brick edging 7cm wide 11.4cm deep to plinth protection with common burnt clay (nonmodular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 Cement : 4 fine sand) and curing complete.
36Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm.
37Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
38Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)..
39Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size).
40Providing and laying vitrified floor tiles in Size of tile 600x1200 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.Make Hindware Queo/Kajaria/Simpolo/Nitco/Agl
41Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
42Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour or shade (Area of slab over 0.5 sqm) Rate per sqm 16mm.
43Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work.
44Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
45Providing and laying Ceramic glazed floor tiles 600x600 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown.Make Hindware Queo/Kajaria/Simpolo/Nitco/Agl
46Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.Make Hindware Queo/Kajaria/Simpolo/Nitco/Agl
47Providing and fixing of charcoal wall panelsrectangular in shape made of charcoal and polystyrene proportionately 12mm thick and fire-resistant, waterproof, termite proof, weather resistance, durable material, anti static, and premium quality with an option of colors as per the choice of the Architect/ Engineering- in charge of size 300x2850 or 270x600 mm providing a minimum sound absorption level of 0.90 NRC. Then 8 mm HDMR perforated Board of Gyptech Make should be Screwed to the GI frame with the help of 25 X 6 mm metal screw 25mm thick fabric acoustical panel should be pasted on the 8 mm HDMR perforated Board with the help of rubber base Adhesive of Pidilite or equivalent make as per drawing and design of Engineer-in-Charge.
48Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately) For fixed portion Powder coated aluminum (minimum thickness of powder coated 50 microns).
49Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately). For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminum (minimum thickness of powder coated 50 microns).
50Providing and fixing Aluminium Composite Panel (ACP) 3mm thick + 0.5% ACP aluminium sheet on Door/ Window shutter in white/ Ivory colour with water resistant and termite proof along with all necessary fitting complete job as per the Direction/ Engineer-in- charge.
51Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item). With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm).
52Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S Flat 15x3 mm and nuts and bolts complete. Stainless steel (grade 304) wire gauze of 0.5mm dia wire and 1.4 mm aperture on both sides.
53Providing and fixing of aluminium beading.
54Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S.sheet outer box with slide plate etc. complete as per the direction of Engineerin-plate etc. complete as per the direction of Engineer-in-charge.With Stainless Steel cover plate minimum 1.25 mm thickness.
55Filling the gap in between aluminum frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5mm width.
56Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc.complete..
57Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screw etc. complete as per direction of Engineer-in-charge. Powder coated minimum thickness 50 micron aluminum tabular handle bar.
58Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper.
59Providing and fixing Stainless Steel tower bolts 304 grade. with nuts and screws etc. complete.
60200X10mm.
61150X10mm.
62100X10mm
63Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete. 300x16 mm.
64Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm.
65Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.100 mm.
66Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete
67Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre.
68Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler 110 mm.
69Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm.
70Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 110mm bend.
71Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 75mm bend.
72Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. BEND 87.5X160mm.
73Providing and fixing un-plasticised -PVC pipe clips of approved design to un-plasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm.
74Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
75Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube.
76Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
77Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
78Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.1 mm thick.
79Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm).
80Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm.
81Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
82Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge.
83Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%,humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items. (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.
84Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.
85Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately) with grass turf.
86Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment).
87Supplying and stacking at site dump manure from approved source including carriage complete (manure measured in stacks will be reduced by 8% for payment). Screened through sieve of I.S. designation 4.75 mm.
88Fine dressing of the ground.
89Mixing earth and sludge or manure in proportion specified or directed by officer in charge.
90Provision for trees at height of 6ft of Green Bottle Palm Tree,
91Providing, making, and installing 3D fabricated stainless-steel letters made from SS 304 grade, minimum 1.2–1.5 mm thickness, with mirror-polished finish. Letters shall include integrated LED backlit illumination (cool white or as approved), complete with acrylic backing, LED modules, wiring, power supply/driver, and necessary heat dissipation arrangements.
92Providing & Fixing of p.v.c sheet signages & bond in front of every Accomodation / Room fix with S.S. screw.
93Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes.
94Providing and fixing 5mm thick transparent acrylic sheet of approved brand, colour and shade, including cutting to required size, edge polishing, drilling bending whereever required, complete with all acessories and fittings such as aluminium/ SS brackets, screws, nuts and bolts, washers, rubber beading, spacers, silicon sealent cleats support system complete in all respects as per approved design and direction of Engineer- in-charge
95Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete.
96Stone agg. above 40mm size for an avg. lead of 10 Kms.
97Stone agg. / Sand for an avg. lead of 10 Kms.
98Bricks for an avg. lead of 20 Kms.
99Plumbing (Part-B).
100Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.Make Hindware Queo/Jaguar Artize/Kerovit
101Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. W.C. pan with ISI marked white solid plastic seat and lid.Make Hindware Queo/Jaguar Artize/Kerovit
102Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 liter/6 liter (adjustable to 4 liter/8 liters), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.Make Hindware Queo/Jaguar Artize/Kerovit
103Providing and fixing complete set of sanitary fixtures for handicapped toilets, CERA CRUSE SET ) comprising of EWC 710X370X770MM, , Cistern, Seat Cover, Twin Flush Fittings, Wash Basin 665X545X190MM, l, 1 faucet with spatula lever, 1 hinged rail and 1 grab bars, including cutting and making good the walls and floors wherever required complete as per directions of Engineer in charge. Make Hindware Queo/Jaguar Artize/Kerovit
104Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:Range of two urinal basins with 5 literwhite P.V.C automatic flushing cistern.Make Hindware Queo/Jaguar Artize/Kerovit
105Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively.Make Hindware Queo/Jaguar Artize/Kerovit
106Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer.Make Hindware Queo/Jaguar Artize/Kerovit
107Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.Make Hindware Queo/Jaguar Artize/Kerovit
108Providing & fixing of white vitreous china table top counter oval wash basin/Circular basin/ Square basin (ESSEL CAT NO- 72031100 / KEROVIT CAT NO- KS249 / CERA CAT NO- S2020174) with CP brass waste assembly, CP cast brass bottle trap with extension piece wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required as per direction of Engineer-Incharge. Make Hindware Queo/Jaguar Artize/Kerovit
109Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board. 510x1040mm bowl depth 250mm.Make Hindware Queo/Jaguar Artize/Kerovit
110Providing and fixing of C.P. brass Central Hole Basin Mixer/ Table top Mixer without Popup Waste System (Essel Cat No 113001 / Kerovit Cat No.KB2111010 & CERA CAT NO- F1020451 ). including with 450mm Long Copper Pipes & Brass Nuts with all fittings and accessories as per direction of Engineer-Incharge. Make Hindware Queo/Jaguar Artize/Kerovit
111Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931.Make Hindware Queo/Jaguar Artize/Kerovit
112Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.Make Hindware Queo/Jaguar Artize/Kerovit
113Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931.Make Hindware Queo/Jaguar Artize/Kerovit
114Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931.Make Hindware Queo/Jaguar Artize/Kerovit
115Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge.
116Providing and fixing C.P hand spray with lever control (Health faucet) Jaquar Cat No. ALDCHR-565 / Kerovit Make KA580001) and flexible hose 1 m long connection with C.P holder for hand spray complete in all respects as per direction of Engineer-in-charge.Make Hindware Queo/Jaguar Artize/Kerovit
117Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete. Semi rigid pipe 32 mm dia.Make Hindware Queo/Jaguar Artize/Kerovit
118Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete. Semi rigid pipe 40mm dia.Make Hindware Queo/Jaguar Artize/Kerovit
119Providing and fixing toilet paper holder C.P. brass.Make Hindware Queo/Jaguar Artize/Kerovit
120Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms.
121Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Make Hindware Queo/Jaguar Artize/Kerovit
122Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
123Providing & fixing C.P. brass robe hook (ESSEL Cat No. 114026 ,Kerovit Cat No. KA980003 & CERA CAT NO- F5003108) or approved equivalent) fixed to wall/door with plastic rawl plugs and C.P brass screws including cutting and making good the walls wherever required as per direction of Engineer-Incharge. Make Hindware Queo/Jaguar Artize/Kerovit
124Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms.
125Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth. Granite Stone of approved shade. 18mm.
126Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
127Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms.
128Providing and fixing Plane floor trap with heavy class SS grating and setting in floor with cement mortar to match the floor finish as per direction of Engineer-in-charge (size 100 X 75mm mm dia) ISI marked. (MAKE:- Kerovit, Essel, CERA, Hindware)
129Providing & fixing storage type water cooler with plain & cold water facility of the following capacity, I.S.I marked, stainless steel front panel, C.P brass push cock, inlet float valve with all plumbing and electrical accessories, inlet, outlet, overflow and PVC drain out connection to F.D complete as required (Blue Star or equivalent).Cooling capacity 20 Ltrs./hr (Model No. Bluestar PC240) Storage capacity 40 Ltrs.
130Providing & fixing commercial 20 LPH water purifier of required capacity 8 LTR. Including all components as per manufacture specifications, including connection from water supply line, and final connection to water cooler electric wiring & plug top etc. with all accessories.(MAKE:- KENT GRAND, AQUAGUARD, OR EQUIVALENT)
131roviding, storing, handling, shifting, installation, testing & commissioning of vertical / horizontal storage type hot water heater fixed to wall with anchor bolts & nuts, 20mm CP brass cock and 20mm non return valve complete including making connection with 15 mm dia CP connecting pipe on Inlet and Outlet, suitable length of power cable and 15A plough (for pantry & Toilets). (Make : Hindware, Bajaj or equivalent).Capacity 10 liters.
132Sub Head-II Water supply :-
133Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
134Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge. Internal work concealed with clamps at 1.00 meter spacing including cutting the chases and making good the wall etc. 1216 (16mm OD) pipe
135Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge. Internal work concealed with clamps at 1.00 meter spacing including cutting the chases and making good the wall etc. 1620 (20mm OD) pipe.
136INTERNAL WORKS - EXPOSED ON WALL
137Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work-Exposed on wall. 15 mm dia. nominal bore (Medium).
138Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work-Exposed on wall 20 mm dia. nominal bore (Medium).
139EXTERNAL WORK
140Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work).25 mm dia. nominal bore (Medium).
141Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work). 32 mm dia. nominal bore (Medium).
142Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work). 40 mm dia. nominal bore (Medium).
143Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work). 80 mm dia. nominal bore (Medium).
144Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 15 mm nominal bore.
145Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 20 mm nominal bore.
146Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). 25 mm nominal bore.
147Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). 32 mm nominal bore.
148Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). 40 mm nominal bore.
149Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work..15 mm diameter pipe.
150Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work..20 mm diameter pipe.
151Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work..25 mm diameter pipe.
152Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work..32 mm diameter pipe.
153Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work..40 mm diameter pipe.
154Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete. 25 to 40 mm nominal bore.
155Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work). 15 mm nominal bore.
156Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work). 20 mm nominal bore.
157Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work). 25 mm nominal bore.
158Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work). 32 mm nominal bore.
159Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work). 40 mm nominal bore.
160SUB HEAD - III DRAINAGE SYSTEM
161Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed in all kind of soils. Rate for a lead upto 1 meter from cutting edge.
162Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diametre.
163Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre.
164Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 150 mm diametre.
165Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix (1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line.
166Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 600x850 mm and 45 cm deep for single pipe line with three or more inlets.
167Providing and fixing 100 mm sand cast iron grating for gully trap.
168Providing and fixing heavy class SS grating plane including setting in floor with cement motor to match with floor finish as per direction of Engineer-Incharge (Size 100 mm dia) (ISI Marked).
169Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
170SUB HEAD - WATER SUPPLY, DRAINAGE, PUMPS & EQUIPMENT :- Supply, assembly, erection, testing and commissioning of pumping system comprising the following: Vertical/Horizontal centrifugal pumps with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, Single phase, 50 cycles A.C. supply with 65/ 65mm dia. pressure gauges including MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump) (Make:- Crompton,Wilo, Ebara and Matherplatt etc.) Model MBQ32(1PH)-15, Capacity 3 H.P, Suction -65mm x Delivery 65mm (Domestic water relift pump).
171ELECTRICAL WORKS
172Sub Head-I (Wiring) :-
173Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group-A).Make GRANDLAY, POLYCAB, HAVELLS, RR
174Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.Make GRANDLAY, POLYCAB, HAVELLS, RR
175Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface / Recessed medium class PVC conduit as required.Make GRANDLAY, POLYCAB, HAVELLS, RR
1762 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1772 X6 sq. mm + 1 X 6 sq. mm earth wire
1782 X16 sq. mm + 1 X 6 sq. mm earth wire
1794 X 6 sq. mm + 2 X 6 sq. mm earth wire
1804 X 16 sq. mm + 2 X 6 sq. mm earth wire
181Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required. Make ABB, SCHNEIDER(UNICA PURE), LEGRAND(ARTEOR)
182Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.Make ABB, SCHNEIDER(UNICA PURE), LEGRAND(ARTEOR)
183Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.Make ABB, SCHNEIDER(UNICA PURE), LEGRAND(ARTEOR)
184Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.Make ABB, SCHNEIDER(UNICA PURE), LEGRAND(ARTEOR)
185Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.(For AC And Geyser).Make ABB, SCHNEIDER(UNICA PURE), LEGRAND(ARTEOR)
186Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Make ABB, SCHNEIDER(UNICA PURE), LEGRAND(ARTEOR)
187Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Make AKG, ASTRAL, STEELKRAFT, RMCON
18825 mm.
18940 mm.
190Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.12 way , Double door.Make ABB, SCHNEIDER(ACTI-9), LEGRAND(EKINOX 3)
191Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)Make ABB, SCHNEIDER(ACTI-9), LEGRAND(EKINOX 3)
1926 way (4 + 18), Double door
1938 way (4 + 24), Double door
19412 way (4 + 36), Double door
195Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make ABB, SCHNEIDER(ACTI-9), LEGRAND(DX 3)
196Single Pole
197Single pole and neutral
198Supplying and fixing 40 A to 63 Arating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and neutral.Make ABB, SCHNEIDER(ACTI-9), LEGRAND(DX 3)
199Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make ABB, SCHNEIDER(ACTI-9), LEGRAND(DX 3)
20032A F.P MCB 10 Ka \\"C\\" Curve
20163 A F.P MCB 10 Ka \\"C\\" Curve
202Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required.Make ABB, SCHNEIDER(ACTI-9), LEGRAND(DX 3)
203LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ mbossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim.Make PANASONIC PROF LIGHTING, TRILUX, WIPRO, PHILLIPS
20412 -15 watt
20518 watt
206Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.1200 mm.Make KUHL, CROMPTON, CG, HAVELLS
207Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan made out of Metal Body with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required. 300 mm.Make KUHL, CROMPTON, CG, HAVELLS
208Supply installation testing and commissioning of IP:20 Decorative Light 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab.Make PANASONIC PROF LIGHTING, TRILUX, WIPRO, PHILLIPS
209LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).120 watt.Make PANASONIC PROF LIGHTING, TRILUX, WIPRO, PHILLIPS
210Supply installation testing and commissioning of IP65 led Bulk head 10 W +/- 1 W LED Surface Pressure Die Cast Aluminum system lumen efficacy of 100 lm/W with Polycarbonate Opal Diffuer and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80, IK rating IK08. The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 265V. The Fixture should have In-built Surge Protection of 2.5kV Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab .Make PANASONIC PROF LIGHTING, TRILUX, WIPRO, PHILLIPS
211LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 40 Watt.Make PANASONIC PROF LIGHTING, TRILUX, WIPRO, PHILLIPS
212LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) :-Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material andconstruction as per IS : 10322 with driver as per therequirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internalsurge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) <19, Flicker free,(flicker should be below 5 %), life time (LED, Driver& electrical circuitry), of minimum 50000 BurningHours with , 70% of initial Lumen maintained tilllife ends, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(StandardDeviation Color Matching) <3, Maximum powerconsumption should not more than the specifiedrating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testingrequired for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink of aluminium housing such that LED junctiontemperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36 watt.Make PANASONIC PROF LIGHTING, TRILUX, WIPRO, PHILLIPS
213Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
214Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
215Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
216Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
217Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55)( AMF Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .Make D-TECH INDUSTRIES, JAIMA ELECTRIC, ELECTRICFIELD
218INCOMER
219Adj. TMR Based MCCB 400 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH .Make ABB, SIEMENS(3VA)SCHNEIDER(NSX)
220500 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
221Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.Make ABB, SIEMENS, SCHNEIDER
222OUTGOINGS
223Control Board along with Relays and other Electronic Material Required for Making the AMF Operation
224Power Contactor 560 A F.P 415 Volts AC-1 Duty.Make ABB, SIEMENS, SCHNEIDER
225Adj. TMR Based MCCB 320 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH.Make ABB, SIEMENS(3VA)SCHNEIDER(NSX)
226Adj. TMR Based MCCB 250 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH.Make ABB, SIEMENS(3VA)SCHNEIDER(NSX)
227Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH. Load Bearing Members to be made out of 2.0 mm CRCA Sheet, Partitions to be made out of 1.6 mm CRCA Sheet, Gland Plates to be 3.0 mm Thick.Make ABB, SIEMENS(3VA)SCHNEIDER(NSX)
228Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .Make D-TECH INDUSTRIES, JAIMA ELECTRIC, ELECTRICFIELD
229INCOMER
230Adj. TMR Based MCCB 320 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH.Make ABB, SIEMENS(3VA)SCHNEIDER(NSX)
231400 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
232Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.Make ABB, SIEMENS, SCHNEIDER
233OUTGOINGS
234D.P 63 A 10 Ka \\"C\\" Curve MCB
235F.P 32 A 10 Ka \\"C\\" Curve MCB
236F.P 63A 10 Ka \\"C\\" Curve MCB. Load Bearing Members to be made out of 2.0 mm CRCA Sheet, Partitions to be made out of 1.6 mm CRCA Sheet, Gland Plates to be 3.0 mm Thick.
237Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( UPS Distribution Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .
238INCOMER
239D.P 63 A 10 Ka \\"C\\" Curve MCB.ABB, SIEMENS(3VA)SCHNEIDER(NSX)
240100 A,240 Volts 50Hz Aluminium Busbar set of 2 strips
241Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.Make ABB, SIEMENS, SCHNEIDER
242OUTGOINGS
243MCB Changeover 63 A D.P 10 Ka.Make ABB, SIEMENS(3VA)SCHNEIDER(NSX)
244D.P 25 A 10 Ka \\"C\\" Curve MCB.Load Bearing Members to be made out of 2.0 mm CRCA Sheet., Partitions to be made out of 1.6 mm CRCA Sheet, Gland Plates to be 3.0 mm Thick.Make ABB, SIEMENS(3VA)SCHNEIDER(NSX)
245Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads.
246UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc
247Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.Make REX ,ASTRAL, VECTUS
248160 mm dia (OD-160 mm & ID-135 mm nominal)
24963 mm dia (OD-63 mm & ID-51 mm nominal)
250Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.Make GRANDLAY, POLYCAB, HAVELLS, RR
2513.5 C X 300 Sq.mm A2XFY (From AMF To Building Dist. Panel)
2523.5 C X 25 Sq.mm A2XFY (From Building Dist. Panel To Lift)
2534.0 C X 16 Sq.mm A2XFY (From SLFP To Street Light)
2543.0 C X 10 Sq.mm A2XFY (From SLFP To Security DB)
255Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.Make GRANDLAY, POLYCAB, HAVELLS, RR
2563½ X 300 sq. mm (70 mm)
2573½ X 25 sq. mm (28mm)
2584 X 16 sq. mm (28mm)
2593 X 10 sq. mm (22mm)
260Supply installation testing and commissioning of 45 W Post Lantern Lamp Pressure die-cast aluminium housing with specially designed optics, provide uniform light distribution to redefine outdoors and enhance architectural design with System efficacy of 100 lm/W.L70 life of 50000 Hrs. P.F.>0.95 with THD<10% ,CCT 5700 K,CRI 70,Surge Protection 4 Kv. Input voltage range of 120V to 300V.Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab.
261Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation and re-filling as required.Make TRUEPOWER, OBO BETTERMANN, INGESCO, VNT
262Supply,Installation of 3 Mtr 80 mm G.I Pole made of Galvanised Mild Steel Pipe Duly Painted with Two Coats of Primer and Aluminium Paint Including the Cost of Foundation
263SITC of IP: 66/IP:67 PVC Junction Box having the Facility to house 4 way Bakellite strip for connection to the spike light (i).Make AKG, ASTRAL, STEELKRAFT, RMCON
264Supplying and Laying of Sheathed 3 C x 2.5 Sq.mm Copper Conductor Multistrand Wire IS:694.Make GRANDLAY, POLYCAB, HAVELLS, RR
265(II) 12 C x 1.5 Sqm copper cable.Make GRANDLAY, POLYCAB, HAVELLS, RR
266Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55)( Street Light Panel Board ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD .Make D-TECH INDUSTRIES, JAIMA ELECTRIC, ELECTRICFIELD
267INCOMER
268Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH .Make ABB, SIEMENS(3VA)SCHNEIDER(NSX)
269100 A,415 Volts 50Hz Aluminium Busbar set of 4 strips
270Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.Make ABB, SIEMENS, SCHNEIDER
271OUTGOINGS
272MCB 25 A F.P 10 Ka 415 Volts \\"C\\" Curve. Load Bearing Members to be made out of 2.0 mm CRCA Sheet., Partitions to be made out of 1.6 mm CRCA Sheet, Gland Plates to be 3.0 mm Thick.Make ABB, SIEMENS(3VA)SCHNEIDER(NSX)
273Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm).Make ABB, SCHNEIDER(UNICA PURE), LEGRAND(ARTEOR)
274Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Make ABB, SCHNEIDER(UNICA PURE), LEGRAND(ARTEOR)
275Telephone socket outlet
276Computer Socket
277Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in theexisting surface/ recessed Steel/ PVC conduit as required.1 run of cable.Make MICROTEK; D-LINK, MOLEX, POLYCAB
278Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair .Make MICROTEK; D-LINK, MOLEX, POLYCAB
279Supply & Erection of lockable 12 U rack with 5A strip and two fan for distribution, mounting of patch panels, hubs, switches etc,, complete as per specification and as desired by EIC.
280SITC of Patch Cord Category 6 4-Pair, F/UTP, Horizontal cable, 23 AWG solid bare copper conductors WITH RJ45 CONNECTOR AT BOTH END 1 MTR LENGTH.
281SITC of Patch Cord Category 6 4-Pair, F/UTP, Horizontal cable, 23 AWG solid bare copper conductors WITH RJ45 CONNECTOR AT BOTH END 2 MTR LENGTH.Make MICROTEK; D-LINK, MOLEX, POLYCAB
282Supplying,Installation,Testing and Commissioning of 55 Inches Full H.D LED Display Monitor as per the Specifications attached.
283Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome Camera, 1/2.7\\" CMOS or better, 5MP (2880 x 1620) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 30m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/2-1/100000S,Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 2.8mm, Field of View FoV H:90°, V:50°, BLC, HLC, WDR, 3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence Video Analytics, 4 Privacy Mask, 8 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2-Way Audio Full Duplex Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE (802.3 af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T Compliant, CE, FCC, EN, RoHS & NDAA Section 889 compliant.ISTOC competent item No. 40.5.1 (As per DSR 2025).
284Supply , Installation , Testing and commissioning of 24 Channel NVR (Network Video Recorder) Embedded Linux based for recording upto 24CH at D1 960fps with 04 nos. SATA HDDs minimum 40TB storage or more (recording requirement all cameras recording at D1, 25fps for 30 days), H.265 HEVC/H.264/MJPEG codec decoding, Front Panel with LEDs Indication for Power & HDDs Status, 3 nos. USB, ONVIF S, Time Sync with NTP, Encrypted Streaming & Control, 2-Way Audio Line & Out, PTZ Operation Pan, Tilt, Zoom, Support, Pre & Post Alarm Recording Support, Recording/Evidence Clip Export to USB, 16 Channel Synchronous Playback, Playback control i.e Play, Pause, Stop, Fast Forward, Backward, Speed Control, Timeline & Zoom; Snapshot, Web Client, Central Monitoring Software, iPhone; iPad; Android based Mobile clients, 02HDMI & 01VGA Output, 04 On Board HDDS each up to 10TB, Alarm Input (06 nos.), Alarm Output (02 nos.), 196 Mbps throughput, NDAA Section 889 Compliant, Operating Temperature –10°C to 55°C, Certification : Certifications: ONVIF compliant, UL/CSA 62368-1, CE (EN 50130-4), FCC Part 15, EN 55032, NDAA & RoHS (EN63000) compliant. Including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge.
285SITC of 10TB 7200 rpm SATA 6 Gb/s 3.5\\" Internal Enterprise Hard Drive item No. 40.12.4 (As per DSR 2025).
286Supplying and Laying of 20 Mtr HDMI Optical Fiber Cable AOC 2.0, 4K with Bandwidth 18Gbps
287Supplying and Fixing of S.D Card 256 G.B in the Existing Camera
288SITC of CAT 6 F/UTP 16 Port Modular fully loaded patch Panel TIA/EIA-568-C.2:2009 EN 50173- 1:2011 Class E, ISO/IEC11801:2010 (Ed 2.2) Class E, FCC Subpart F68.5 UL Listed.
289SITC of CAT 6 F/UTP 24 Port Modular fully loaded patch Panel TIA/EIA-568-C.2:2009 EN 50173- 1:2011 Class E, ISO/IEC11801:2010 (Ed 2.2) Class E, FCC Subpart F68.5 UL Listed. Item No. 39.11.
290Supply, Installation, Testing and Commissioning of Layer 2, PoE enabled, with PD: minimum 370 Watt (should have minimum 15.4 Watt per Port), fully managed, 1RU, GE Switch to be operated on 200-240VAC, 50 Hz Supply, with perpetual license of OEM,having minimum technical specification:a) 16 x 10/100/1000Base-T Mbps PoE+ enabled host ports (Minimum); b) 4 x 10GE SFP+ port; c) Forwarding performance/stacking bandwidth/backplane speed (Minimum) of 95.2Mpps; d) Fanless operation with operating temperature up to 50°C; e) DRAM and Flash RAM as per OEM; f) Software support with IPv4 routing (542 routes), multicast routing (IGMP) including necessary software license; g) Minimum switching capacity of 216Gbps; h) Number of VLAN Supported: 64 (Minimum).; i) Total number of MAC Address: 8,000 (Minimum); j) Minimum Security: User privilege management and password protection, DoS attack defense, ARP attack defense, and ICMP attack defense, Binding of the IP address, MAC address, interface, and VLAN, Port isolation, port security, and sticky MAC, MFF, Blackhole MAC address entries, Limit on the number of learned MAC addresses, 802.1x authentication and limit on the number of users on an interface, AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC, SSH v2.0, Hypertext Transfer Protocol Secure (HTTPS), CPU defense, l; l) REGULATORY: RoHS, WEEE, IEC 61000-4-2:2008, CISPR Class, ICES-003 Class A,UL,CSA 22.2,FCC,EN 300 386, CCC, ICES -003, CB.The OEM should have 24x7 TAC support center with India toll free number reflected in official website.Make: Cisco, Juniper,Extreme/Netgear/Allied Telesis.
291Supply, Installation, Testing and Commissioning of Layer 2, PoE enabled, with PD: minimum 370 Watt (should have minimum 15.4 Watt per Port), fully managed, 1RU, GE Switch to be operated on 200-240VAC, 50 Hz Supply, with perpetual license of OEM,having minimum technical specification:a) 24 x 10/100/1000Base-T Mbps PoE+ enabled host ports (Minimum); b) 4 x 10GE SFP+ port; c) Forwarding performance/stacking bandwidth/ backplane speed (Minimum) of 95.2Mpps; d) Fanless operation with operating temperature up to 50°C; e) DRAM and Flash RAM as per OEM; f) Software support with IPv4 routing (542 routes), multicast routing (IGMP) including necessary software license; g) Minimum switching capacity of 216Gbps; h) Number of VLAN Supported: 64 (Minimum).; i) Total number of MAC Address: 8,000 (Minimum); j) Minimum Security User privilege management and password protection, DoS attack defense, ARP attack defense, and ICMP attack defense, Binding of the IP address, MAC address, interface, and VLAN, Port isolation, port security, and sticky MAC, MFF, Blackhole MAC address entries, Limit on the number of learned MAC addresses, 802.1x authentication and limit on the number of users on an interface, AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC, SSH v2.0, Hypertext Transfer Protocol Secure (HTTPS), CPU defense, l; l) REGULATORY: RoHS, WEEE, IEC 61000-4-2:2008, CISPR Class, ICES-003 Class A,UL,CSA 22.2,FCC,EN 300 386, CCC, ICES -003, CB. The OEM should have 24x7 TAC support center with India toll free number reflected in official website.Make: Cisco, Juniper, Extreme/Netgear/Allied Telesis. item No. 39.3 (As per DSR 2025).
292Supply,Installation,Testing and Commissioning of Media Converter.
293Supply & Erection of Termination Box complete as per specification and as desired by EIC.
294Supplying,Installation,Testing of 12 Core Optical Fibre Cable Single Mode.
295Supplying,Installation,Testing of 10 Pair Main Distribution Frame Box for telephone Connections
296Supplying,Installation,Testing of 20 Pair Main Distribution Frame Box for telephone Connections
297FIRE DETECTION
298Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication ard,minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
299Two Loop Panel.
300Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
301Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
302Supplying, installation, testing & commissioning of fault isolator complete with base as required.
303Supplying, installation, testing & commissioning of addressable manual call point complete as required.
304Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.Make RALLISON, KEI, POLYCAB, HAVELLS
305Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires
306Supplying,Installation,Testing and Commissioning of MAP 90 ABC Type Fire Extinguisher 4.0 Kg. Capacity ISI Mark(IS:15683)suitable for Class A/B/C Type Fires .
307D.G SET
308Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD pecifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of anufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Tourbo charged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level. (C) Alternator Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.Make MAHINDRA, CATERPILLAR, CUMMINS, KIRLOSKAR
309(D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/ connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency,
310power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: JKAMP paid shall be complete with bye-pass system.1/ Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2/ Auto/Manual/Test/Off selector switch. 3/ Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4/ 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering. 5/ Energy analyser unit to indicate current, Voltage (LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6/ LED Indicating lamps for load on mains and load on set. 7/ Fuse/ MCB for instruments. 8/ Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9/ Main supply failure monitor 10/ Supply failure timer 11/ Restoration timer. 12/ Control unit with three impulse automatic engine start/stop and failure to start lockout. 13/ Impulse counter with locking and reset facility. 14/ ON/OFF/Control circuit switch with indicator. 15/ Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning 16/ Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories. 17/ Maintenance notification based on Engine Run Hour & due date. 18/ Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. 180KVA (M ake approved by E.I.C).
311Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
312Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
313Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
314Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
315SUB STATION.
316Supplying,Installation of 9 Mtr. Long Pole(PCC WL-300Kg , ST-410 SP33)
317Supply,installation of Structural Steel as per Standard Approved Drawing
318Supply,Installation and Commissioning of 11 KV Air Break Switch(200 Amps).
319Supply,Installation of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
320Supply,Installation of 11 KV HG Fuse Unit .
321Supply,Installation of Disc Insulator(B&S)70 KN suitable for 100 sq.mm Triple AAAC.
322Supply and Installation of 100 Sq.mm AAAC Triple AAAC.
323Supply,Installation of 11 KV Pin Insulator suitable for 100 sq.mm Triple AAAC.
324Supply and Erection of 150 mm Dia. Heavy Class G.I Pipe for the Cable Protection.
325Supply and Installation of Anti Climbing Device
326Supplying, installation, testing and commissioning of following capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, KNAN [K(K-Class insulating liquid) Natural Air Natural] copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better),Dielectric material shall be type -A, suitable for out door/indoor applications with Offload Tap Changer/ On Load Tap Changer (OLTC) ( below 500 KVA offload and above 500 KVA On Load Tap Changer) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sq.mm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from ransformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS 1180 (Part-3) including first filling of filtered dehydrated Synthetic organic Ester oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with +12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. Make JAIMA ELECTRIC, VOLT AMP, SCHNIDER, SIMENS
327The permissible temperature-rise shall not exceed 40 0C for oil and 45 0C for winding up to 200 KVA and 45 0C for oil and 50 0C dg. C for winding for above 200 KVA. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 0C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminium/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers;
328g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. 250 Kva.
329Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
330Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
331Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
332Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
333Design, Supply, installation, testing and commissioning of Following Ratings of Servo Controlled Automatic Voltage Stabilizer, 3 phase, oil cooled (transformer oil to be the cooling medium conforming to IS-335 with latest amendments) conforming to IS-8447-1989, IS-9815 I & II of 1994 amended up to date. The voltage stabilizer should be suitable to operate on unbalanced input voltage of 160-450 volts and delivering output voltage of 415 + 1% volts, 3 phase, 50 + 3% cycles/second frequency of A.C power supply. The stabilizer shall be copper wound Out door Type with By Pass Panel.250 Kva I) The voltage stabilizer shall be suitable for the following configurations:- a) Input Voltage: 250-460 Volts b) Output Voltage: 415 + 1% c) Frequency: 50 Hz + 3% A.C supply d) Duty: continuous 24x7 f) Temp. Rise in Oil:-50 degree C g) Temp. Rise in Winding:-55 degree C h) Overload Capacity:100% for 1 minute i) Regulator: Rolling Contact Type j) Type: Unbalanced Type –Suitable for unbalanced input voltage and unbalanced load, Outdoor g) Design and Testing Standards:IS:9815/IS 2026.Make JAIMA ELECTRIC, D-TECH INDUSTRIES, SERVOKON,
334k).The no-load current shall not be more than 5% of the rated output current. II) Instrument Accessories: The voltage stabilizer shall be provided with as under:- a) Mains ON indicating lamps for each phase. b) Indicating lamps in each phase with lights up/ audio alarm when the input voltage exceeds beyond limit or overload or phase failure/phase reversal. c) Voltmeter at input & output with voltage selector switch to read input/output voltage in each phase. d) Switch to change over from automatic to manual operation. e) Auto/manual switch raise/lower push button in each phase. f) Ampere meter with selector switch g) Control circuit separate in each phase. h) Protection against high & low voltage, single phasing, cut off alarm, its cancellation, short circuiting, overload protection and earth fault relay. i) By Pass Arrangements:- By pass switch shall be provided to by pass the stabilizer in case of any fault. j) Heavy terminal blocks and solid state controlled circuit for input, output and earth connections, which should be clearly marked.k) Protections: Suitable capacity MCCB for tripping the stabilizer in case of under voltage, over voltage, short circuit, overload, single phasing conditions. Make JAIMA ELECTRIC, D-TECH INDUSTRIES, SCHNIDER, SIEMENS CHANGE IN SCHEDULE A - ABB, SIMENS, SCHNIDER REMOVE HAVELLLS AND L&T
335l) Efficiency at full load more than 95%. The stabilizer should be conforming to IS 9815/1981. m) Purity of copper shall be minimum 99.97% (Certificate from manufacturer shall be attached along with the Invoice). n) The stabilizer should have aesthetic outlook with screen printed panel. Make of Instrument Accessories: G.E./ L&T / Siemens / Schneider / Havells/other reputed make conforming to relevant ISI code). III) Characteristic features:- The three phase Servo Controlled Automatic Voltage Stabilizer shall have the following characteristic features:- a) Continuous duty performance at ambient temperature 2 °C to 55° C. b) Stable and effective system power factor and frequency fluctuation as well as overload up to 15% and under load up to 50% of the connected load.. c) Low internal impedance. d) Negligible wave form distortion during starting, under operation and stopping conditions. e) Accommodate the effect of higher starting current and should be able to recover from the shock. f) No overshooting or hunting.g) Negligible phase shift ensuring no change in system power factor. h) Should ensure fast correction of voltage according to voltage variation specified. i) The stabilizer shall have a suitable breather with leak-proof desludging and drain cock for transformer oil, lifting hook for mechanical handling, guage for oil level etc. j) The three phase unbalanced automatic servo controlled voltage stabilizer should take care of the unbalanced supply with A.C step synchronous motor.IV) Markings:- The stabilizer shall be marked with manufacture’s name and trade mark on the plate fitted on the stabilizer and indicate KVA rating, range of input and output voltage, rated output current, frequency, number of phases, type of load viz unbalanced input and balanced load, quantity of transformer oil and also reference to I.S. standard. In addition, the information relevant to Servo-Motor viz Rated KW, Rated Voltage, Type of Supply and No. of Phases etc. shall also be given on the rating plate. V) Testing & Inspection:- Make JAIMA ELECTRIC, D-TECH INDUSTRIES, SCHNIDER, SIEMENS CHANGE IN SCHEDULE A - ABB, SIMENS, SCHNIDER REMOVE HAVELLLS AND L&T
336The equipment shall be inspected and tested before dispatch to the consignee by the third party. The firm shall have adequate testing facilities available at their work site. The scope of inspection shall include testing of stabilizer as per type of test prescribed in IS-9815 of 1994 and 8447 of 1989 as relevant to Servo Controlled Voltage Stabilizers. It shall also include testing of voltage stabilizer for all protections. The testing of the stabilizer shall comprise of the following tests:- a) Insulation resistance test. b) High Voltage test. c) Under voltage test. d) Provision of earthling. e) Leakage current test. f) No load current test. g) Measurement of no load losses. h) Load loss test and efficiency. i) Induced voltage test. j) Test for continuous operation. k) Temperature rise test at lowest voltage of 260 volts. l) Test for rate of correction. m) Locked rotor test for servo motor. n) Full load test. VI) Layout of Components/Drawings:- Layout of Components and control wiring shall conform to established engineering practice from the consideration of case for maintenance. VII) The job involves shifting of stabilizer to site by way of lifting, carriage and unloading manually or with mechanical crane and installation of the stabilizer, providing and laying of insulation mats etc. Complete job in all respects. (The servo shall be certified by CEIL/RITES) Certificate to be provided.Make JAIMA ELECTRIC, D-TECH INDUSTRIES, SCHNIDER, SIEMENS CHANGE IN SCHEDULE A - ABB, SIMENS, SCHNIDER REMOVE HAVELLLS AND L&T Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56174598
AUTHORITY Government Departments
TENDER VALUE 8.46 Crore
LAST DATE 17-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of School Education Excellence Education Hub / Samagra Office At Gandhi Nagar Jammu (Under The Central Sponsered Scheme Samagra Shiksha During The Current Financial Year 2025-26).
Basic Detail
Tender No e-NIT No.08 of 2026-27 Dated 25.06.2026
Bidding Type Tender
Location
City Kathua
State Jammu and Kashmir
Key Dates
Publish Date 25 Jun 2026
Submission Date 17 Jul 2026
Open Date 18 Jul 2026
Finance
Tender Value 8.46 Crore
Tender Fee 6000
EMD 16.93 Lakhs
Exemption Not Available
Document List
BOQ_1015435.xls
dbe1e7e2-fccb-483c-991d-5cb3b402524f.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1015435.xls

html

dbe1e7e2-fccb-483c-991d-5cb3b402524f.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender