| 1 | Cutting in earth work in all kinds of soil such as pick work, jumper work, blasting work and chiselling work etc. and disposal of excavated earth as directed within all leads and lifts. |
| 2 | Excavation in foundation, trenches,etc. in earth work in all kinds of soil such as pick work, jumper work,blasting work, hard blasting and chiselling etc. stacking the excavated soil not more than 3 mtrs.clear from the edge of excavation and then returning the stacked soil in 15cm.layers when required into plinths sides of foundations etc.then disposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within all leads and lifts.complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 3 | Excavation in drains and channels etc. in earth work for pipes upto all depth in all classification of earth work such as pick work, jumper work, saturated soil i/c balling or pumping out water , blasting soft /hard rock or chiseling soft/ hard rock where blasting is prohibited in all lifts including jungle clearance wherever required, trimming and dressing of sides, levelling of beds to correct grade including shoring /struting, planking, timbering and dewatering wherever required stacking the useable /unusable material/soil seperately and after laying,jointing and testing of pipes ,returning the useable soil in treches in 15 cm layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil/ unusable material as directed within all leads and lifts including restoration of un-metalled surfaces to its original condition and including cost of diversion for traffic, night signals, fixing caution boards,crossing over trenches for access to houses, fencing etc. complete in all respect whithin all leads and lifts as per direction of the Engineer-in-charge. |
| 4 | Providing and laying cement concrete 1:4:8 (1cement: 4sand: 8graded stone agg. 40mm nominal size) and curing complete excluding cost of form work i/c all leads and lifts in foundation and plinth. |
| 5 | Providing and laying cement concrete 1:6:12(1cement: 6sand: 12 graded stone agg.40mm nominal size) and curing complete excluding cost of form work in foundation and plinth. |
| 6 | Providing and laying cement concrete work 1:1:2(1cement:1 and:2 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement in reinforced concrete work i/c all leads and lifts complete in all respect. |
| 7 | Foundation and plinth. |
| 8 | Walls (any thickness) but not less than 0.1 m thickness) including attached pillasters,buttresses, plinth and string courses etc.from top of foundation level upto floor two level. |
| 9 | Providing and laying cement concrete work 1:11/2: 3(M20) (1cement:1 1/2sand:3 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 10 | Foundations footings, bases of columns and the like and mass concrete. |
| 11 | Walls (any thickness) but not less than 0.1 m thickness) attached pillasters, buttresses, plinth and string courses etc. from top of foundation level upto floor two level. |
| 12 | Suspended floors, roofs, landings,shelves and their supports balconies, beams, girders, bressumers and cantilevers upto floor two level. |
| 13 | Providing and laying cement concrete work 1:2:4(1cement:2sand:4 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-charge:- |
| 14 | Foundation and plinth. |
| 15 | Suspended floors, roofs, landings,shelves and their supports balconies, beams, girders, bressumers and cantilevers upto floor two level. |
| 16 | Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering, strutting , strutting and propping etc. with wooden, battens, and ballies, height of propping and centring below supporting floor to ceiling not exceeding 3 mtrs.and removal of the same for insitu reinforced concrete and plain concrete work in complete in all respect i/c all leads and lifts and to the entire satisfaction of the Engineer-in-charge. |
| 17 | Foundations footings, basis of columns and the like and mass concrete. |
| 18 | Vertical surfaces such as walls (any thickness) ,partitions and the like including attached pillasters,buttresses, plinth and string courses and the like. |
| 19 | Flat surfaces such as soffits of suspended floors,roofs, landings, and the like:-i)Floors etc. upto 200mm in thickness. |
| 20 | Edges of slabs and breaks in Floor and walls :- Under 20cm wide. |
| 21 | Providing Mild steel/Tor steel reinforced for RCC work including bending, binding and placing in position complete upto floor two level within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-charge. a) Tor steel. |
| 22 | Prov. in RCC work smooth finishing of the exposed surfaces with cement mortar 1:3(1cement:3sand). |
| 23 | Providing and fixing precast concrete manhole cover and frame conforming to IS-12593-Part-I 1988 and IS 12592 - Part-II 1991, 560mm diameter Heavy Duty complete in all respect i/c all leads and lifts and to the entire satisfaction of the Engineer-in-charge. |
| 24 | Providing, Laying and jointing in trenches,galvanised mild steel tubes (Light grade)confirming to IS-1239 (Part-I) 2004 i/c tube fittings such as Tee, elbow, union & nipple.(earth work in trenches to be measured and paid for separately)i/c all leads and lifts complete in all respect |
| 25 | 40 mm dia nominal bore. |
| 26 | 80 mm dia nominal bore. |
| 27 | Dismantling of old G.I.Pipe (light grade) of following diameter complete in all respect including all leads and lifts and to the entire satisfaction of the Engineer-in-charge (earth work in trenches to be measured and paid for separately). |
| 28 | 40mm dia. |
| 29 | 32mm dia. |
| 30 | 25mm dia. |
| 31 | 20mm dia. |
| 32 | 15mm dia. |
| 33 | Relaying and jointing in trenches,galvanised mild steel tubes(Light grade)(earth work in trenches to be measured and paid for separately)i/c all leads and lifts and as per direction of Engineer-in-charge complete in all respect.Labour rate only. |
| 34 | 40mm dia. |
| 35 | 32mm dia. |
| 36 | 25mm dia. |
| 37 | 20mm dia. |
| 38 | 15mm dia. |
| 39 | Providing and fixing brass full way valve with wheel of superior quality including all leads and lifts In :- |
| 40 | 15 mm dia nominal bore. |
| 41 | 20 mm dia nominal bore. |
| 42 | 25 mm dia nominal bore. |
| 43 | 32 mm dia nominal bore. |
| 44 | 40 mm dia nominal bore. |
| 45 | 50 mm dia nominal bore. |
| 46 | 65 mm dia nominal bore. |
| 47 | 80 mm dia nominal bore. |
| 48 | 100 mm dia nominal bore. |
| 49 | Providing and fixing of G.I.Union as per ISI specifications No.1879-1987(with latest ammendment) of various dia complete in all respect i/c all leads and lifts as per the direction of the Engineer-in-charge. |
| 50 | 15 mm dia nominal bore. |
| 51 | 20 mm dia nominal bore. |
| 52 | 25 mm dia nominal bore. |
| 53 | 32 mm dia nominal bore. |
| 54 | 40 mm dia nominal bore. |
| 55 | 50 mm dia nominal bore. |
| 56 | 65 mm dia nominal bore. |
| 57 | Providing and fixing G.I. Hexa Nipple of different diameter complete in all respect i/c all leads and lifts. |
| 58 | 15 mm dia nominal bore. |
| 59 | 20 mm dia nominal bore. |
| 60 | 25 mm dia nominal bore. |
| 61 | 32 mm dia nominal bore. |
| 62 | 40 mm dia nominal bore. |
| 63 | 50 mm dia nominal bore. |
| 64 | 65 mm dia nominal bore. |
| 65 | Providing circumferencial butt welding joints by electrical arc welding to following dia of G.I.Pipes medium/heavy class welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS:816-1969 specifications, by using welding electrodes of 2.5mm to 6.3mm of Advani Oerlikon (Adore)-CITOJET/ESAB make, confomring to IS:814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of the Engineer-in-charge. |
| 66 | 80 mm dia nominal bore. |
| 67 | 65 mm dia nominal bore. |
| 68 | Prov. wood work in frames of doors, windows clerestory windows and other frames wrought framed and fixed in position:- 2nd class deodar wood |
| 69 | P/F panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows including black enamelled iron butt hinges with necessary screws complete in all respect as per the direction of the Engineer-in-charge i/c all leads and lifts. 40 mm thick 2nd class deodar wood |
| 70 | 20mm cement plaster on rough side of bricks/stone walls for interior plastering upto floor two level including arrises internal rounded angles, chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth:-a)In cement mortar 1:3(1cement:3sand). |
| 71 | Applying two coat of wood preservative on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. |
| 72 | Applying priming coat over new wood and other wood based surfaces after and including preparing the surface by thoroughly cleaning oil grease dirt and other foreign matter as per the direction of the Engineer-in-charge including all leads and lifts. |
| 73 | Distempering two coats with oil bound washable distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and i/c a priming coat with distempering primer of approved brand and manufacturem after thoroughly brushing the surface free from mortor dropping and other foreign matter and also i/c preparing the surface even and sand papered smooth.Priming coat with distemper primer with in all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 74 | Prov. 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts nuts and wooden plugs and embeding in cement concrete block 30x10x15cm.1:3:6 (1cement: 3sand:6graded stone agg. 20mm nominal size).complete in all respect as per the direction of the Engineer-in-charge including all leads and lifts. |
| 75 | P/F aluminium Tower bolts (barrel type) anodized transparent or dyed to required shade and colour with screws etc. complete. (250mm x 10 mm) |
| 76 | Providing and fixing aluminium handles anodized transparent or dyed to required shade and colour and necessary screws etc. complete i/c all leads and lifts and as per direction of Engineer-in-charge. (125 mm) |
| 77 | Providing and fixing anodized aluminium sliding door bolt anodized transparent or dyed to required shade and colour with bolts and nuts screws complete in all respect i/c all leads and lifts and as per direction of Engineer-in-charge. (250 mm x 16 mm) |
| 78 | Steel work welded in built up sections, trusses and framed work including cutting hoisting, fixing in position and applying a priming coat of red lead paint i/c all leads and lifts complete in all respect. In trusses and trussed purlins in buildings.(ISMC).complete in all leads and lifts. |
| 79 | Providing corrugated G.I. Sheet roofing fixed with galvanised iron J. or L. hooks bolts and nuts 8 mm diameter with bitumen and G.I. Limpet washers filled with white lead complete exculuding the cost of purlins refters and trusses.complete in all respect within all leads and lifts as per direction & to the entire satisfaction of Engineer-in-charge:- 0.63 mm thick G.I. sheet |
| 80 | Prov. ridges or hips 60 cm overall in plain G.I.sheet fixed with galvanised iron J or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.0.63 mm thick sheet. |
| 81 | Supplying and fixing woven plains G.I.Wire (as per IS: 280-1978) IS: 4826-1979 wire dia 3.15mm with fencing of mesh 50mm to 150mm to any type of standard rails, straining bolts, etc.including provision of binding wire, staples etc. complete in all respect. |
| 82 | Painting two coats (excluding priming coat) on new steel and other metal surfaces with readymixed paint brushing to give an even shade including cleaning the surface all dirt, dust and other foreign matter i/c all leads and lifts and as per direction of Engineer-in-charge.:- With readymixed paint other than white. |
| 83 | Wiring for light point/exhaust fan point/call bell point wire 1.5 sqm. PVC Insulated heat resistant flame retardent (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5sq.mm.HRFRLS/PVC insulated single core copper conductor cable as required. Group C. |
| 84 | Wiring for power Plug with 2x4 Sq.mm PVC insulated heat resistant flame retardent (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.4 Sq.mm HRFRLS/PVC insulated single core copper conductor cablefor earthing as required. |
| 85 | Wiring for circuit/submain with following size. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable for same size earthing as required. |
| 86 | (i) 1x1.5 sq.m |
| 87 | (ii) 2x 2.5 sq.m |
| 88 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A. |
| 89 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, isolator in the existing MCB DB complete with connections testing and commissioning etc. As required 63 Amps. Cat-A. |
| 90 | Supplying and erection of 6 amps. To 32 amps. Rating, 10 KVA breaking capacity, 240 volts, 'C' curves miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required (a) Single pole & neutral Category-A. |
| 91 | Supplying and fixing Metal box of 180 mm X 100 mm x 60 mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps, piano type switch, connections, painting etc. as required. complete in all respect. |
| 92 | Providing and fixing LED light 20 watt of reputed make with holder and all necessary fitting including all leads and lifts complete in all respect as per directions by Engineer-in-Charge. |
| 93 | Supplying and fixing ceilling fan of reputed make and all necessary fitting including all leads and lifts complete in all respect as per directions by Engineer-in-Charge. Please Enable Macros to View BoQ information |