| 1 | Supplying and drawing of Following size of FRLS/HFFR PVC insulated copper conductor in the existing surface/recess Conduit as requred |
| 2 | 2.X2.5 Sqmm |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single Core.(Make: Polycab/ Finolex/ L&T /KEI) |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm |
| 5 | Providing and fixing following rating and breaking capacity TP&N Discannector release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(Make- L&T/ABB/LEGRAND /INDOASEAN) |
| 6 | 32 A TP&N |
| 7 | 63 A TP&N |
| 8 | 100 A TP&N |
| 9 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(Make- L & T/ABB/LEGRAND /INDOASEAN) |
| 10 | 125 A,36KA,FPMCCB |
| 11 | 200 A,36KA,FPMCCB |
| 12 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. |
| 13 | Single Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 14 | Double Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 15 | Triple Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 16 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 17 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 18 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 19 | 3.5 X 50 sq. mm (35mm) |
| 20 | 3.5 X 70 sq. mm (38mm) |
| 21 | 3.5 X 95 sq. mm (45mm) |
| 22 | 3.5 X 185 sq. mm (57mm) |
| 23 | Making of RCC foundation of dimesion size- 400 mm x 400 mm x 1200mm) with Gr M20 RCC and Fe 415 grade reinforcement for mounting of street line pole. |
| 24 | Supply and erection of 5 Meter Galvanised (as per BS EN ISO 1461) octogonal pole with base plate 200 x 200 x 12 mm, top 70 mm and bottom 130 mm made up of 3 mm thick sheet suitable for max. wind speed upto 160 km/hr. including foundation bolts and HDPE pipe for incoming and outgoung cables and Each pole shall be supplied with a junction/looping box complete with 10 amps, 10 kA DP MCB, DIN mounting Connectors suitable for 16/25 sq.mm terminations complete with DIN bar, shorting links, end locks GI base plate, GI anchor plate etc. as required and 3x1.5 sqmm FRLS PVC insulated and PVC sheathed multistrand copper conductor from junction box to the luminaire complete including terminations with copper lugs etc. as required. (Make-Philips/Valmount/Bajaj/G.E) |
| 25 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 26 | 1 output per phase and suitable for single phase supply |
| 27 | 2 output per phase and suitable for single phase supply |
| 28 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 29 | 120 Watt Make-Phillipse/Wipro/CG |
| 30 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 31 | 100 WattMake-Phillipse/Wipro/Polycab/CG |
| 32 | 200 WattMake-Phillipse/Wipro/Polycab/CG |
| 33 | Supplying and laying of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable of Following size, 1.1 KV grade, direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. etc. as required [conforming to I.S-1554/1/8]. |
| 34 | 4 X 10 sq. mm |
| 35 | 3½ X 35 sq. mm |
| 36 | 3.5CX50 Sqmm |
| 37 | 3.5CX185 Sqmm |
| 38 | Supply and fixing of following sizes of hot dipped galvanised bracket with FRP dome made out of 3.25 mm thick sheet suitable for octogonal pole including painting with superior quality of primer and synthetic enamel paint two or more coats etc. as required. |
| 39 | Single arm bracket of 1.0 Mtr long for mouning of street light with all accessries |
| 40 | Double arm bracket of 1.0 Mtr long for mouning of street light with all accessries |
| 41 | Supplying and fixing of thremoplate cable end box with terminals and sutable aluminium strip bus bar (loop end & loop out ) with protaction IP 66 degree on wall with 2 nos. steel faster having water tight dust proof etc. of size not less than 200mm x140mmx 55 mm in corporate with 6A /10A MCB & connectror etc complete as require (make-Hansel/syntex |
| 42 | Supply and installation of 63/125/250/400 A HRC/kit-kat/wired Fuse in the existing main switch /feeder pilar |
| 43 | Supply, Installation ,testing & Commisionioning (SITC) of outdoor CPRI certified cubical Feeder pilar with EC grade Al busbar capacity 630Amp.100% netural suitable >25ka for 3 sec for fault level ,compatiable for following incomming & outgoing . Custum built self fabricated out of 16SWG , CRCA sheet Foot mounted type Panel Furnished with siemen gray shade powder coated paint after necessary pre treatment fully dust & vermin proof, Copper wire ,Lugs and Netural & Insulating Material Engineering and Labor Charges ,Panle size (H-W-D)mm. Details as Incoming-SFU400 Amp. 2 nos. & 6 nos-HRC fuse, . Incomer All Busbar capacity 500 Amp. Phase indicating light shall be protected by 6 amps MCB‟s. - 3 Sets, AVF Meter - 01 No. Outgoing -Deatils TP MCCB-200 Amp.2 Nos, TP MCCB-125 6 nos. (Range 40A -630A , Protaction against overload, and short and 63Amp MCB-6 nos.circuit) , 0-24 hours Astronomical timer auto / manual by pass selector switches Cubicle Type 1 nos. Note-MCCB Make- Legrand/L& K/Simens/Schneider .Supplying and making end termination with brass compress Make -Allied Engineer/Electrocare/Electrocraft |
| 44 | Repairing of 70/100/120/200W LED Street Light and Flood Light along with replacement of defective/ burn/ not functional LED, Driver, wires and reflector and testing etc. complete as required at site. |
| 45 | Providing services for day to day maintenance, upkeep, Breakdown maintenace, Preventive maintenance and attending complaints of complete internal and external electrical installations including manpower and all work of street light pole upto 5-11 mtr.hight / electrical panel assigned by Engineer-Incharge of all residential and non residential buildings and road within Institute campus, pathway and parcel area lights, panels, feeder pillar etc, on all days including Sundays and holidays etc as required in daily one electrician & one helper in each shift . Duration of Each shift shall be of 8 hour). (Note : Material required for replacement of faulty fixture shall be measured and paid seprately.Cost of all tools, plants and consumables etc. required for above mentioned work is included in the scope of work.) |
| 46 | 200 A/250 A TP&N |
| 47 | 150 watt Please Enable Macros to View BoQ information |