| 1 | Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light/fan point controlled by one switch including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 2 | Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one bell/buzzer point controlled by one push button including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 3 | Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light point controlled by two 2-way switchs including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 4 | Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 5 Amps socket outlet independent including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 5 | All as per Serial Item No. 4 here in before but for one 3 Pin 5 Amps socket outlet on same board with other switches, complete all as specified and directed. |
| 6 | Materials and Labour for point wiring with 2.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 2.50 Sqmm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket outlet independent including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 7 | Materials and Labour for point wiring with 1.50 Sqmm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid into and including stove enamelled steel conduit complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light/fan point controlled by one switch including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 8 | All as per Serial Item No.7 Here in Before but for one 3 Pin 5 Amps socket outlet on same board with other switch, complete all as specified and directed. |
| 9 | Materials and Labour for point wiring with 2.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid into and including stove enamelled steel conduit complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 2.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket outlet independent including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 10 | Materials and Labour for point wiring with 1.50 Sqmm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid into the existing concealed PVC conduit/stove enamelled steel conduit fixed to walls/ceiling including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light/fan point controlled by one switch including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 11 | Supply and fix switch piano, flush button, single pole, one way, 6 Amps, complete all as specified and directed. |
| 12 | Supply and fix in repair switch piano, flush button, single pole, one way, 6 Amps, complete all as specified and directed. |
| 13 | Supply and fix switch piano, flush button, single pole, two way, 6 Amps, complete all as specified and directed. |
| 14 | Supply and fix in repair bell push, flush type, 5 Amps, complete all as specified and directed. |
| 15 | Supply and fix in repair Modular Switch, one way, 6 Amps, 1 Module, complete all as specified and directed. |
| 16 | Supply and fix in repair Modular Switch, 2 way, 6 Amps, 1 Module, complete all as specified and directed. |
| 17 | Supply and fix in repair Modular Switch, one way, 16 Amps, 1 Module, complete all as specified and directed. |
| 18 | Supply and fix ceiling rose, three terminal, PVC/polycarbonate insulated body, complete all as specified and directed. |
| 19 | Supply and fix socket outlet 5 pin, 6A, flush type, complete all as specified and directed. |
| 20 | Supply and fix switch socket combination 2 in 1, 5 pin, 6A flush type, complete all as specified and directed. |
| 21 | Supply and fix in repair switch socket combination 2 in 1, 5 pin, 6A flush type, complete all as specified and directed. |
| 22 | Supply and fix switch socket combination 2 in 1, 6 pin, 6 and 16 Amp flush type universal, complete all as specified and directed. |
| 23 | Supply and fix in repair switch socket combination 2 in 1, 6 pin, 6 and 16 Amp flush type universal, complete all as specified and directed. |
| 24 | Supply and fix in repair Modular Socket, 6 Amps, 5 Pin, 2 Module, complete all as specified and directed. |
| 25 | Supply and fix in repair Modular Socket, 6A/16A, 6 pin, combined 2 module, complete all as specified and directed. |
| 26 | Supply and fixing for modular cover plate with frame 02/01 module, complete all as specified and as directed. |
| 27 | Supply and fixing for modular cover plate with frame 03 module, complete all as specified and as directed. |
| 28 | Supply and fixing for modular cover plate with frame, 04 module, complete all as specified and as directed |
| 29 | Supply and fixing for modular cover plate with frame, 08 module, complete all as specified and as directed |
| 30 | Supply and fix stepped type electronic fan regulator, flush type, on existing phenolic laminated sheet etc. as required, complete all as specified and directed. |
| 31 | Supply and fix in repair stepped type electronic fan regulator, flush type, on existing phenolic laminated sheet etc. as required, complete all as specified and directed. |
| 32 | Supply and fix in repair Modular Fan step regulator, 120W - 2 module, BLDC compatible, complete all as specified and directed. |
| 33 | Supply and fix in repair lamp holder, PVC/Polycarbonate type, with back plate suitable for batten fittings, complete all as specified and directed. |
| 34 | Supply and fix in repair bell multi music type, complete all as specified and directed. |
| 35 | Supply and fix LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 36 | Supply and fix in repair LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 37 | Supply and fix LED light fitting 1x 20W, 220V AC, decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 38 | Supply and fix in repairs LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 39 | Supply and fix decorative wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LED lamp B22 base complete all as specified and directed. |
| 40 | Supply and fix in repair decorative wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LED lamp B22 base complete all as specified and directed. |
| 41 | Supply and fix in repair round shape 5/6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 42 | Supply and fix in repair round/ shape 12/15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 43 | Supply and fix in repair Square shape 12/15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 44 | Supply and fix in repair round shape 12/15 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 45 | Supply and fix in repair square shape 12/15 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 46 | Supply and fix in repairs 36 Watts LED surface type luminaire, size 600 mm x 600 mm with glare free uniform illumination, lumen efficacy >100 Lumen/Watt, complete all as specified and directed. |
| 47 | Supply and fix as in repair square type 190mm x 190mm (outer dia) LED recessed fitting 15 W, 6000k made from extruded aluminium housing frame complete all as specified and directed. |
| 48 | Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sqmm (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 49 | Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing & capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 50 | Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn into and including stove enamelled steel conduit and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/aluminium circuit/ submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed. |
| 51 | Dressing/aligning of existing circuit/sub main wiring by taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including steel conduit with fittings etc., making good disturbed surfaces of walls, floors etc.and refixing the same in original position, complete all as specified and directed.Note:- Damaged steel conduit/PVC Casing Capping for replacement if any will be measured and paid seperately under respective item of this BOQ. |
| 52 | Supply only 25 mm size PVC Casing Capping, ISI Marked (IS:14927), complete all as specified and directed. |
| 53 | Supply only 20 mm external diameter stove enamelled black rigid steel conduit, welded, complete all as specified and directed. |
| 54 | Supply and fix in repairs 3 mm thick plastic laminated sheet cover (ISI Marked) of size 125 mm x 175 mm for mounting switches/ regulator /bell push etc, complete all as specified and directed. |
| 55 | Supply and fix in repairs 3 mm thick plastic laminated sheet cover (ISI Marked) of size 175 mm x 225 mm, for mounting switches/ regulator /bell push etc, complete all as specified and directed. |
| 56 | Supply and fix Double Door Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 4 way, with 200 Amps rated bus bar, Single Pole & Neutral, complete all as specified and directed. |
| 57 | Supply and fix Double Door Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 200 Amps rated bus bar, Single Pole & Neutral, complete all as specified and directed. |
| 58 | Supply and fix, Double Door Sheet Metal Enclosure for DBs, 415 Volts, 4 Way, Triple Pole & Neutral, complete all as specified and directed. |
| 59 | Supply and fix miniature circuit breaker (MCBs), single pole, 240 Volts, 10KA, C curve, 6 to 32 Amps, complete all as specified and directed. |
| 60 | Supply and fix in repair, miniature circuit breaker (MCBs), single pole, 240 Volts, 10KA, C curve, 6 to 32 Amps complete all as specified and directed. |
| 61 | Supply and fix miniature circuit breaker (MCBs), single pole and neutral, 240 Volts, 10KA, 6 to 32 Amps, complete all as specified and directed. |
| 62 | Supply and fix in repair miniature circuit breaker (MCBs), single pole and neutral, 240 Volts, 10KA, 6 to 32 Amps, complete all as specified and directed. |
| 63 | Supply and fix miniature circuit breaker (MCBs), single pole and neutral, 240 Volts, 10KA, 40 Amps, complete all as specified and directed. |
| 64 | Supply and fix in repairs miniature circuit breaker (MCBs), single pole and neutral, 240 Volts, 10KA, 40 Amps complete all as specified and directed. |
| 65 | Supply and fix miniature circuit breaker (MCBs), triple pole & neutral, 415 Volts, 10KA, 63 Amps complete all as specified and directed. |
| 66 | Supply and fix in repair miniature circuit breaker (MCBs), triple pole & neutral, 415 Volts, 10KA, 63 Amps complete all as specified and directed. |
| 67 | Supply and fix PVC blanking plates, single way suitable for blank ways of MCB DBs, complete all as specified and directed. |
| 68 | Taking down carefully existing ceiling fan 1200 mm/1400 mm sweep, dismantaling parts, cleaning throughly internally and externally, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts, re-assembling, hanging in original position and connecting up including provision of cable from ceiling rose or connector to fan and including testing and commissioning, complete all as specified and directed. |
| 69 | Taking down carefully existing exhaust fan 300 mm/450 mm sweep, dismantaling parts, cleaning throughly internally and externally, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts, re-assembling, fixing in original position and connecting up including provision of cable from ceiling rose or connector to fan and including testing and commissioning, complete all as specified and directed. |
| 70 | Disconnecting power supply from existing wall mounted/table fan any size/sweep, taking down carefully, dismantaling parts, cleaning throughly internally and externally, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts, re-assembling, fixing in original position and connecting including testing and commissioning, complete all as specified and directed. |
| 71 | Disconnecting power supply from existing pedestal fan of any size/sweep, dismantaling parts, cleaning throughly internally and externally, lubrication of bearing / bushes using fresh lubricant all as per OEMs recommendations, replacement of defective parts, re-assembling, placing in original position and connecting up including testing and commissioning, complete all as specified and directed.NOTES:- (Applicable for BOQ Serial Item No.69 to 72)(i) Repair woks shall be carried out through authorised technicians of the OEMs as approved by GE.(ii) Spares for replacement will be measured and paid separately. |
| 72 | Taking down carefully existing ceiling fan 1200 mm/1400 mm sweep, dismantaling of parts, removing burnt out windings with insulating materials, cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts, re-assembling, hanging in original position including testing and commissioning, complete all as specified and as directed. |
| 73 | Taking down carefully exhaust fan 300/380/450 mm size, dismantaling of parts, removing burnt out windings with insulating materials, cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts, re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed. |
| 74 | Disconnecting power supply, taking down carefully existing wall mounted fan any size/sweep, dismantaling of parts, removing burnt out windings with insulating materials, cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts, re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed. |
| 75 | Disconnecting power supply from existing pedestal fan of any size/sweep, dismantaling of parts, removing burnt out windings with insulating materials, cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts, re-assembling, placing in original position including testing and commissioning, complete all as specified and directed. NOTES:- (Applicable for BOQ Serial Item No.73 to 76)(i) Repair woks shall be carried out through authorised technicians of the OEMs as approved by GE.(ii) Spares for replacement will be measured and paid separately. |
| 76 | Materials and Labour for painting of exhaust fans 300mm/400mm/450mm size complete with synthetic enamel paint by spray machine including filling cavities with filler, one coat after cleaning all dust etc. including writing MES No., complete all as specified and as directed. |
| 77 | Materials and Labour for painting of pedestal fans of any size/sweep complete with synthetic enamel paint by spray machine including filling cavities with filler, one coat after cleaning all dust etc. including writing MES No., complete all as specified and as directed. |
| 78 | Supply only Gun Metal Bushing/Sleeve Bearing of suitable bore for any shaft size of fans, complete all as specified and directed. |
| 79 | Supply and fixing as in replacement of Capacitors for electric fan motors, 2.5 mfd, 440 V conforming to IS:1709, complete all as specified and directed. |
| 80 | Supply and fixing as in replacement of Capacitors for electric fan motors, 4 mfd, 440 V conforming to IS: 1709, complete all as spcified and directed. |
| 81 | Supply only Chrome Steel Ball Bearing of size 6201 for fan as per OEMs specifications, complete all as specified and directed. (Make: TATA/NBC/SKF) |
| 82 | Supply only Chrome Steel Ball Bearing of size 6003 for fan as per OEMs specifications, complete all as specified and directed. (Make: TATA/NBC/SKF) |
| 83 | Supply only Chrome Steel Ball Bearing of size 6202 for fan as per OEMs specifications, complete all as specified and directed. (Make: TATA/NBC/SKF) |
| 84 | Supply only Chrome Steel Ball Bearing of size 6204 for fan as per OEMs specifications, complete all as specified and directed. (Make: TATA/NBC/SKF) |
| 85 | Taking down carefully existing defective storage type water heater (geyser) of Capacity 25/50 Litres of any Make for repairing, including replacement of defective spares as required including descaling of storage tanks internally, brazing of leakage if any in tanks and including replacement of terminals with defective connection wires and reinstallation of the geyser in original position including testing and commissioning, complete all as specified and directed.NOTES:- (i) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE.(ii) Spares for replacement will be measured and paid separately. |
| 86 | Supply only Thermostat, stem type, adjustable upto 75 Degree Celcius, ISI Marked (IS 3017), complete all as specified and directed. |
| 87 | Supply only Heating Element, 2000 Watts for geyser as per OEM's specifications, complete all as specified and directed. |
| 88 | Supply only brass pressure reliese valve suitable for geyser as per OEMs specifications, complete all as specified and directed. |
| 89 | Supply only Glass Incandescent Electric Water Heater Indicator Lamp, in multi-color caps as per OEMs specifications, complete all as specified and directed. |
| 90 | Supply only brass non return valve,15 mm size suitable for geyser as per OEMs specifications, complete all as specified and directed. |
| 91 | Supply only 600 mm long PVC Hot/Cold water connections,15mm size, with brass nuts, complete all as specified and directed. |
| 92 | Supply and fix in repair, 3-Pin plug top 16 Amps, complete all as specified and directed. (Code No. 39582 of Make Anchor or equivalent of Make Polycab/Havells) |
| 93 | Supply and fix in repair PVC insulated and FR PVC round sheathed cable with copper conductor (flexible), nominal area of conductor 4.0 sq mm, 3 core, 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable, complete all as specified and directed. |
| 94 | Supply and fix in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240V, complete all as specified and directed. |
| 95 | Supply and fix in repairs metal frame and louvers suitable for exhaust fan, steel body, AC single phase, 230V of size 300 mm sweep, complete all as specified and directed. |
| 96 | Supply and fix exhaust fan made of sturdy Engineering body plastic complete AC single Phase 230V, 50Hz, RPM 1200 copper winding of 200mm sweep, louvers shutters with all grouting & fasterners including cutting of walls for fixing of exhaust fan and making good the disturbed surface with plaster with CM 1:4, complete all as specified and directed by Engr-in-Charge. |
| 97 | Supply and fix exhaust fan made of sturdy Engineering body plastic complete AC single Phase 230V, 50Hz, RPM 1200 copper winding of 250mm sweep, louvers shutters with all grouting & fasterners including cutting of walls for fixing of exhaust fan and making good the disturbed surface with plaster with CM 1:4, complete all as specified and directed by Engr-in-Charge. |
| 98 | Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep Min air delivery 210 CFM with five star rated with squirrel cage induction motor and including provision of PVC insulated sheathed round flexible wire with multistranded copper condictor of size 1.50 Sqmm 3 core 1100 volts, complete all as specified and directed. |
| 99 | Supply and fix exhaust fan, steel body AC single Phase 230V of size 300mm sweep, heavy duty with blades, frame and louvers, complete all as specified and directed. |
| 100 | Supply and fix exhaust fan, steel body AC single Phase 230V of size 380mm sweep, heavy duty with blades, frame and louvers, complete all as specified and directed. |
| 101 | Supply and fix exhaust fan, steel body AC single Phase 230V of size 450mm sweep, heavy duty with blades, frame and louvers, complete all as specified and directed by Engr-in-Charge. |
| 102 | Supply and fix wiremesh gauge 0.1mm to 2mm stainless steel surface finish polished and tensile strenth 200-400 Mpa tolerance 1.5 to 3.5mm all as specified and directed |
| 103 | Materials and Labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire, complete all as specified and directed. |
| 104 | Materials and Labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanised steel earth lead wire 4 mm dia. by means of bolts, nuts check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil, complete all as specified and indicated on electrical plate No 3 of SSR Part –I (2009) including testing on completion. Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - (Water proofing compound will be measured and paid separately) Please Enable Macros to View BoQ information |