| 1 | Design, engineering and Supply of material |
| 2 | 220KV Control and Relay Panel for Line/Feeder,simplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GEMICOM/ALSTOM/SCHNEIDER with IEC 61850compatibility, with two Distance Protection Main 1 & main 2 shall be of two different make or of same make with two different platforms with same specifications] |
| 3 | 220KV Control and Relay Panel for Bus coupler cum BusBar, simplex/duplex as per requirement, completely wiredincluding Substation automation supportingIEDs/numerical relays of make ABB/SIEMENS/GEMICOM/ALSTOM/SCHNEIDER with IEC 61850compatibility, with Bus-Bar Protection suitable for min 20bays. Non Directional O/C & E/F Protection and LocalBreaker Backup (LBB) Protection. |
| 4 | 220KV Control and Relay Panel for Transformer Bay simplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GEMICOM/ALSTOM/SCHNEIDER with IEC 61850compatibility, including Differential Protection , Restricted Earth Fault Protection Directional O/C & E/F Protection , Over Fluxing Protection and Local Breaker Backup (LBB) Protection separate relays for primary and backup protection |
| 5 | 132KV Control and Relay Panel for Line/Feeder simplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GEMICOM/ALSTOM/SCHNEIDER with IEC 61850compatibility, including Distance Recorder and under Frequency Relay. (Ist Line Protection) Distance Protection Directional O/C & E/F Protection (Back Up Protection), Local Breaker Backup (LBB) Protection |
| 6 | 132KV Control and Relay Panel for Bus couplersimplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDER with IEC 61850compatibility,including Bus bar Protection suitable formin 15 No bays |
| 7 | 132KV Control and Relay Panel for Transformer bay simplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDER with IEC 61850compatibility, including Differential Protection, Directional O/C & E/F Protection (on HV & LV side), numerical communicable REF protection relay, Over Fluxing Protection Local Breaker Backup (LBB) Protection separate relays for primary and backupprotection |
| 8 | 132KV Control and Relay Panel for Incomer bay simplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDER with IEC 61850compatibility, including Differential Protection, Directional O/C & E/F Protection (on HV & LV side), numerical communicable REF protection relay, Over Fluxing Protection Local Breaker Backup (LBB) Protection separate relays for primary and backupprotection |
| 9 | supply of 2 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/strip armoured stranded copper conductor control cable complete |
| 10 | supply of 5 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/strip armoured stranded copper conductor control cable complete |
| 11 | supply of 8 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/strip armoured stranded copper conductor control cable complete |
| 12 | supply of 16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS,Galvanised steel wire/strip armoured stranded copper conductor control cable complete |
| 13 | supply of 2Core, 6sqmm, 1100V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/strip armoured stranded copper conductor control cable complete |
| 14 | 4Core, 6sqmm, 1100V, PVC insulated ,PVC sheathed, FRLS, galvanised steel wire/strip armoured stranded copper conductor control cable complete |
| 15 | 33KV Control and Relay Panel for Line/Feeder simplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDER with IEC 61850compatibility, with under frequency relay E/FProtection (Main Protection) and O/C (Backup Protection). |
| 16 | 33KV Control and Relay Panel for Transformer Bay simplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDER with IEC 61850compatibility, |
| 17 | 33KV Control and Relay Panel for Bus Coupler bay with backup protectionsimplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDERwith IEC 61850 compatibility, |
| 18 | 33KV Control and Relay Panel for Capacitor Bank bay with backup protectionsimplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDERwith IEC 61850 compatibility, |
| 19 | 33KV Control and Relay Auxillary Panel simplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDER withIEC 61850 compatibility, |
| 20 | 245kV, 50c/s ,2500 A, SCADA Compatible, 50kAfor one second, Ac motor operated horizontaldouble break, outdoor type 3 pole Isolators withTwo Earthing switches COPPER FIXED ANDMOVING CONTACTS/ COPPER CURRENTCARRYING PARTS, GALVANISED IRONMECHANISM BOX |
| 21 | Galvanised Structure for 220 KV Beam for sectionalising the Main Bus |
| 22 | Spares for the above panels 5 no Tand C Swithces, 5 no Ammeters, 2 no Frequency meters, 5 no Voltmeters, 10 no Indicator bulbs, 5 no. Master tripping relays, 2 no O/C/E fault relays SCADA compatible, 2 no tool kits complete with spaners from 08 mm to 42 mm size, 2 no clamp meters to measure curremnt in milli Amps. |
| 23 | supply in Contigency and T&P items |
| 24 | Meeger 15 KV |
| 25 | BDV Kit 100 Amps Capaicty |
| 26 | Primary injection set with 400 Amps capacity |
| 27 | Earth Tester (Clamp type) |
| 28 | Hydralic compresser to compress fittings with dies for panther, zebra and Moose conductor |
| 29 | Hydraulic cutter for cutting conductor |
| 30 | Power Chian Saw for cutting trees |
| 31 | Bush Cutting machine |
| 32 | Crimping tool from 2.5 mm to 200 mm |
| 33 | Desktop with I 9 generation 14, and 32 GB RAM/ 1 TB SSD with Laser coulor Printer and UPS with double battery |
| 34 | Thermo vision camera with Range of 70 mtrs atleast |
| 35 | standing heavy Drill Machine with sorts of bits for drilling holes in clamps |
| 36 | Erection, testing and commissioning |
| 37 | item no 1.01 |
| 38 | item no 1.02 |
| 39 | item no 1.03 |
| 40 | item no 1.04 |
| 41 | item no 1.05 |
| 42 | item no 1.06 |
| 43 | item no 1.07 |
| 44 | item no 1.08 |
| 45 | item no 1.09 |
| 46 | item no 1.10 |
| 47 | item no 1.11 |
| 48 | item no 1.12 |
| 49 | item no 1.13 |
| 50 | item no 1.14 |
| 51 | item no 1.15 |
| 52 | item no 1.16 |
| 53 | item no 1.17 |
| 54 | item no 1.18 |
| 55 | item no 1.19 |
| 56 | item no 1.20 |
| 57 | Dismantling of Existing material mentione from S no. 1.01 to 1.18 and writeback of the material to the Divisional Store Narwal. |
| 58 | Civil Works |
| 59 | foundation of 245 KV Isolator with Two Earthing Switches. Please Enable Macros to View BoQ information |