| 1 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 2 | Demolition of brick work or stone/boulders masonary, built in cement mortor including all quoins, arches pillars, etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 3 | Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc including ridges complete all as specified and directed by Engineer-in-charge. |
| 4 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge. |
| 5 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 6 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge. |
| 7 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and directed. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed. |
| 9 | Taking down chowkhats with shutter (without taking off shutters from the frame) area not exc. 1.50 Sqm each complete all as specified and directed. |
| 10 | Taking down chowkhats with shutter (without taking off shutters from the frame) area exc. 1.50 Sqm but n.exc 4.00 sqm each complete all as specified and directed. |
| 11 | M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge. |
| 12 | All as per Srl item No 11.00 here-in-before but except brick.Note : Old serviceable brick retrieved from serial item No 2.00 of BOQ here-in-before shall be used under this item. |
| 13 | S&F in repairs 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 14 | S&F in repairs door closer hydraulically regulated designation No. 3 universal type cast iron body suitable for door shutters of 851 to 1000mm in width and fixed complete all as specified and directed by Engineer-in-charge. |
| 15 | S&F in repairs curtain rod, stainless steel of 25mm dia with fixing brackets stop rollers etc fix complete all as specified and directed. |
| 16 | S&F venetian blinds for window UV protection, waterproof, corded roll up and down blinds and blinds including roller shade contains metal bracket, screw etc complete all as specified and directed by Engineer-in-charge. |
| 17 | S&F rolled mild steel as in Joist, channel, angle or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length directed) and similar work conforming to Gde E-250 (Fe 410-W) quality `A’ all as specified and as directed. |
| 18 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 19 | S & F 605X605 mm size of grid GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended form soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section ( not exc 1.2 m length ) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including Hangers 6 mm dia. GI (up to 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40X 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia. 40 mm long etc complete all as spd and as directed. Incl providing and fixing non asbestos coloured designer board 4 mm thick in ceiling fixed with screw as per manufacturer's instructions complete all as specified and directed by Engineer-in-charge. |
| 20 | S&F GI lay in metal ceiling system of 600 x 600mm module which includes provides and fixing 'C' wall angle of size 20 x 30 x 20 mm of 0.5 mm thick prepainted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm c/c , suspending the main main C carrier os size 10 x 38 x 10 mm made of GI steel 0.7mm thick from the soffit with help of soffit cleat 37 x 27 x 25 x 1.6mm, rawl plugs of size 38 x 12 mm and C carrier suspension clip and main carrier bracket at 1000mm c/c. Inverted triangle shaped spring Tee having height of 24mm and width of 34 mm made of GI steel 0.45mm thick is then fixed to main C carrier and in direction to perpendicular to it at 600mm c/c with help of suspension brackets. Where ever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120gm/sqm(both side inclusive, fixing with clip in tiles into spring T with:- |
| 21 | GI metal ceiling lay in plain beveled edge global white colour tiles of size 600 x 600mm and 0.5mm thick with 25mm height, made of GI sheet having galvanizing of 100gm/sqm (Both side inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 22 | GI metal ceiling lay in plain beveled edge global white colour tiles of size 600 x 600mm and 0.5mm thick with 25mm height, made of GI sheet having galvanizing of 100gm/sqm (Both side inclusive) and 20% perforation area with 1.8mm dia holes and having NRC of 0.5 electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. |
| 23 | S&F hollow corrugated shape PVC wall lining consisting of 5mm thick decorative colour PVC sheet, heavy duty as per sample approved by GE, inclusive of solvent cement and fixing and incl beading at sides on PVC frame as per specifications all as specifed complete all as specified and directed. |
| 24 | S&F hollow corrugated shape WPC louvers heavy grade consisting of 23mm thick decorative colour as per sample approved by GE, inclusive of solvent cement and fixing at site as per specifications all as specifed complete all as specified and directed. |
| 25 | M&L for in repair to aluminium door/window of any size/any description , taking off from present position and refixing in the same position after tightening , easing/change the section as required , including fitting the rubber packing aluminium snap beading resetting floor/hydraulic door closer/spring etc complete all as specified and directed by Engineer-in-charge. |
| 26 | S&F Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 27 | S&F Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium door section, aluminium sections weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws Anodise aluminium fitting such as including hinges 100 mm long (2 no) and suitable handle(2 No) complete all as specified and directed. |
| 28 | S&F Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium window and ventilator shutters side hung type without sash, aluminium sections weighing 0.55 kg/ m including necessary joining cleats, glazing clips rubber packing, anodised aluminium snap beading screws Anodise aluminium fitting such as peg stays 150 mm long (1 No ), including pag stay and hinges type B-21 100 mm long (2 No) and suitable handle (1 No) complete all as specified and directed. |
| 29 | M&L for aluminium grill mesh made out of 6mm dia having girth not exc 25mm both ways fixed with aluminium cleat to window frame complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F in replacement powder coated aluminum partition using 95.6mmx 44.8mm x 1.00-1.2mm frame work with 12mm thick exterior grade veneered particle board with decorative veneers on both face/5.5mm thick frosted glass including aluminum beading for fixing board each panel n.exc 1.2 Sqm complete all as specified and directed by Engineer-in-charge. |
| 31 | S&F 5.5mm thick sheet glass ordianary quality glazing with with rubber for fixing glass complete all as specified and directed by Engineer-in-Charge. |
| 32 | S & F 5mm thick coloured ACP (Aluminium composit Pannel) sheet using aluminium partition including joining cleats for fixing etc. (colour of sheet approved by GE). |
| 33 | S&F Sheet glass 4 mm thick in glazing to aluminium door, window & partition including pad, gasket complete all as specified and directed. |
| 34 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge. |
| 35 | M&L for vitrified ceramic tiles light shade 8-9mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed bed in CM (1:4) complete all as specified and directed. |
| 36 | All as per item No 33.00 (here-in-before) above but as in skirting over 10mm thick backing coat in CM (1:3) complete all as specified and directed. |
| 37 | M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate) as in floor finishes and leveling course complete all as specified and directed. |
| 38 | M&L for rendering 15 mm thick in CM 1:4 including water proofing compound on fair face of brick or concrete surface, finished even and fair without using extra cement complete all as specified and directed.Note:- WPC shall be measured and paid saperately. |
| 39 | M&L for rendering 10mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished surface fair and smooth without using extra cement complete all as specified and as directed. |
| 40 | M&L for rendering 5mm thick in CM (1:4) as on ceiling complete all as specified and directed. |
| 41 | Supply only liquid water proofing compound ISI marked complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| 42 | Supply only liquid water proofing compound ISI marked complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |