| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: HQ CWE Jhansi Name of Work: REPAIR/MAINT OF POINT WIRING FOR OTM ACCN, MD ACCN AND MISC ITEMS UNDER AGE BR-I, II AND AGE (P) AREA OF GE GWALIOR Contract No: CA NO CWE/JHA/GWL/TOKEN/42 OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down old point wiring any size any type and removing old material from site all as directed. |
| 3 | Taking down old submain wiring of any size any type and removing old material from site. |
| 4 | M&L, concealed modular point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No) not less than 20 mm dia with all fitting and fixing accessories and 1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes/modular flush box factory made suitable size for modular mounting switch, regulators etc with and including plastic sheet for modular switch with cover of suitable size ISI marked, fixed with steel screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches. sockets etc complete for the following:- |
| 5 | One light point controlled by one modular switch with 1.5 sqmm wire. |
| 6 | One Ceiling fan point controlled by one modular switch and regulator with 1.5 sqmm wire. |
| 7 | One Exhaust fan point controlled by one modular switch with 1.5 sqmm wire. |
| 8 | One Rechargable / invertor tubelight point controlled by one modular switch with 1.5 sqmm wire. |
| 9 | One bldg light point controlled by one modular switch with 1.5 sqmm wire . |
| 10 | One ceiling light point controlled by one modular switch with 1.5 sqmm wire . |
| 11 | One 3 pin socket, 6 Amps on the same board controlled by one modular switch with 1.5 sqmm wire.. |
| 12 | One 3/5 pin socket, 6 Amps on independent board controlled by one modular switch with 1.5 sqmm wire. |
| 13 | One Bell/Buzzer point controlled by one modular bell push with 1.5 sqmm wire . |
| 14 | Description all as per item No 5 here in before but point wiring with 2.5 sqmm FRLSH confirming to IS multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire. |
| 15 | S&F in repair Modular Switch, 6 Amp,1 module complete all as specified and as directed. |
| 16 | S&F in repair Modular Socket, 6 amp 2 module, complete all as specified and as directed. |
| 17 | S&F in repair Modular Switch,16 Amp ,1 module complete all as specified and as directed. |
| 18 | S&F in repair Modular Socket 6/16 Amp, 2 module, 6 Pin complete all as specified and as directed. |
| 19 | S&F in repair ceiling rose surface bakelite 63.5 mm dia complete all as specified and as directed. |
| 20 | S&F in repair 2 module,120 Watt, Fan step regulator complete all as specified and as directed. |
| 21 | S&F in repair modular bell push flush type, 5 Amps complete all as specified and as directed. |
| 22 | S&F in repair Ding Dong bell, AC, 230 Volts, single pole complete all as specified and as directed. |
| 23 | S&F in repair Modular Lamp holder with metal ring, PVC/Polycarbonate type ISI Marked complete all as specified and as directed. |
| 24 | S&F in repair Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt,4000k to 6500k as per required fitting , incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and as directed. |
| 25 | S&F in repair 20 Watt Rechargable emergency Invertor type LED Tubelight fitting of LED with Backup Time up to 4 hours,powerful 2600mAh Lithium Ion battery, extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500K to 4000k as per direction of engr-in-charge ,luminous efficiency 100 lm/watt fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection with white insulation tape from ceiling rose to connector of LED fitting including taking down of old u/s light and testing on completion all as specified and as directed. |
| 26 | S&F in repair 20 Watt water proof decorative surface mounted hexagonal bulk head LED Light comprising of high brightness LEDs IP 66 protection including reqd length of 1.5 Sqmm PVC multistranded 03/02 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and as directed. |
| 27 | S&F in repair LED Recessed Mounted Ceiling light 600 mm x 600 mm 35/36 watt, 220 Volts 6500K White Colour ,luminous efficiency 130lm/watt, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling incluing connecting upto drive with reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection to connector of LED fitting including testing on completion & Taking down old unsv fittings complete all as specified and as directed. |
| 28 | S&F 6 sqmm pvc sub main wiring with two single core PVC insulated unsheathed FRLSH , multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and as directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 29 | S&F 4 sqmm pvc sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 4 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and as directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 30 | S&F in repair earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 sqmm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete 01 x 6 mm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and as directed as per MES Schedule Part I & II. |
| 31 | S&F in repair sheet metal enclosure double door for distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 100 Amp, 4 pole & Including MCCB 100 amps 4 pole complete. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down complete all as specified and as directed by GE. |
| 32 | S&F in repair MCB SP 63 Amps, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and as directed. |
| 33 | S&F in repair sheet metal box SPN enclosure with a two pin and earth plug socket (AC Box) complete with one single pole MCB 20 Amp complete all as specified and directed. |
| 34 | S&F in repair MCB DB, SPN 8 way sheet metal enclosures double door with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and as directed |
| 35 | S&F in repair MCB SPN 40-63 amp, 240 volts 'C' series with suitable size copper lugs complete all as specified and as directed.. |
| 36 | S&F in repair MCB SP 6 to 32 Amps, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and as directed. |
| 37 | S&F in repair Modular/non modular Switch, 6 Amp complete including taking down complete all as specified and as directed. |
| 38 | S&F in repair Modular/non modular Socket, 6 amp complete including taking down complete all as specified and as directed. |
| 39 | S&F in repair Modular/non modular Switch,16 Amp complete including taking down all as specified and directed. |
| 40 | S&F in repair Modular/non modular Socket 6/16 Amp, 6 Pin complete including taking down complete all as specified and as directed. |
| 41 | S&F in repair Switch Socket Combination 2 in 1 5 pin, 5 Amp including taking down complete all as specified and as directed. |
| 42 | S&F in repair Switch Socket Combination 2 in 1 6 Pin 5/15 amp including taking down complete all as specified and as directed. |
| 43 | S&F in repair ceiling rose surface bakelite 63.5 mm dia complete including taking down complete all as specified and as directed. |
| 44 | S&F in repair Modular/non modular Fan step regulator complete including taking down complete all as specified and as directed. |
| 45 | S&F in repair Lamp holder with metal ring, PVC/Polycarbonate type ISI Marked including taking down complete all as specified and as directed. |
| 46 | S&F in repair Ding Dong bell, AC, 230 Volts, single pole complete all as specified and as directed. |
| 47 | S&F in repair modular/Non modular metal flush box with suitable size hylum sheet including refixing the old/new switch,socket, regulator and ss combination of different size complete all as specified and as directed by engineer-in-charge |
| 48 | M&L for checking the serviceability of energy meter and connection and load testing for checking status of meter complete all as specified and as directed |
| 49 | S&F in repair Energy meter cover box ,Engineering Plastic,Transparent,Hinge Type locking,suitable for Single/Three Phase,Weatherproof, Easy Access, Durable Design, Secure Locking, Modern Design complete all as specified and as directed. |
| 50 | S&F in repair modular plate including fixing of modular switchs , modular socket ,modulare regulator complete all as specified and as directed following items |
| 51 | White cover plate with frame but 2/3/4 module |
| 52 | White cover plate with frame but 6/8/12 module |
| 53 | M&L for servicing of Air conditioning of any type and any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and as directed. Total in Figures 23 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |