| 1 | Demolition of cement concrete in ground floor and paving not exceeding 15cm thick ( below or above ground level) complete including removal of debries out side MD land all as specified and as directed. |
| 2 | M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling , mass concrete, sub base, levelling course, etc complete all as specified and as directed. |
| 3 | M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling , mass concrete, sub base, levelling course, etc complete all as specified and as directed. |
| 4 | M&L for 75mm thick cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in floor/ plinth protection finish the surface even and smooth with using extra cement including filling the expansion joints with bitumen filler / filler boards and necessary form work etc complete all as specified and as directed. |
| 5 | Demolition of Stone slabs and tiles of any description or thickness in floors complete all as specified and as directed. |
| 6 | M&L for chequered cement concrete tiles with grey cement and pigment of size 25cmX25cmX25mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 7 | M&L for chequered cement concrete tiles with grey cement and pigment of size 40cmX40cmX40mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 8 | M&L for machine cut kota stone slab in flooring 20 to 25mm thick laid over and including 15mm thick screed bed in CM 1:6 & cement mixed with pigment to match the shade of slab including rubbing and laid over and including and polishing complete all as specified and as directed. |
| 9 | M&L for 60mm thick machine pressed precast concrete interlocking paver block of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and including joints filled with sand over and including 25mm thick stone dust as in levelling course of interlocking complete all as specified and as directed. |
| 10 | M&L for 80mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-40 Gde of approved shape, size and colour conferming to IS 15658-2006 and including joints filled over and including 25mm thick stone dust as in levelling course of interlocking complete all as specified and as directed. |
| 11 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 12 | Dismantling posts or struts (wood, steel or RCC) embedded in concreteany section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed. |
| 13 | Dismantling of wrought iron or mild steel work of any description not other wise provided for complete all as specified and as directed. |
| 14 | S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts,including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed (each line wire to be measured) |
| 15 | S&F in repairs mild steel galvanised punched-type concertina coil, 1050 mm diameter (diameter of coil when unstretched), fixed to angle iron supports with 3.15 mm diameter GI wire complete all as specified and directed. |
| 16 | Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and directed by Engr in Charge. |
| 17 | M&L for PCC 1:2:4 type B2 (using 40 mm graded crushed stone aggregate) as in foundation ,post, etc complete all as specified and directed by Engr in Charge. |
| 18 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire. complete all as specified and directed by Engr in Charge. |
| 19 | Supply only Chain link mild steel galvanised fencing, any size or type complete all as specified and directed. |
| 20 | S&F 10 mm dia mild steel TMT bar for fixing of chain link fencing with post complete all as specified and directed. |
| 21 | S&F 11 to 15mm dia of neck mild steel Screw bolts(Machine made ) with hexagonal or square heads at one end and screwed at other end or both end, and screwed end to be fitted with washer and one hexagonal or square n.exc 20 cm long etc complete all as specified and directed. |
| 22 | S&F mild steel framed work as in doors or gates of angle iron, door frame or other section with gusset plate, rails, braces etc complete, drilled for fixing of steel sheeting or other covering etc, to prepared for hanging or sliding with including either hooks and hinges also fastening grills, grating, hold fast of doors and windows chowkat etc, with ends of bars shouldered and or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanksand fixing and similar work confirming to fe 290 Gde E-165 including of dismantlinf of Timber structure if any complete all as specified and as directed. |
| 23 | M&L for Green/Blue/Red powder coated 4mm dia wire mesh fence system perimeter coated welded wire mesh fence steel panel of area n.exc 10 Sqm and mesh size as directed by Engr-in-Charge complete all as specified and as directed. |
| 24 | S&F powder coated mild steel post for 3D fence including all clamps,bolts, fittings,fixtures and size of post as decided by Engr-in-Charge complete all as specified and directed. |
| 25 | Desilting and cleaning of open drains of any section by mechanical means, including removal of solid and semi-solid materials of any type, vegetation growth, and sludge. The desilted materials shall be disposed of beyond a distance exceeding 5.00 KM from the edges of the drains. The work shall be carried out complete in all respects as specified and as directed by the Engineer-in-Charge. |
| 26 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removing debris outside MD land complete all as specified and as directed. |
| 27 | M&L for brick work with using flyash bricks modular size straight or curved on plan exc 6 m mean radius built in CM (1:6) complete all as specified and as directed. |
| 28 | M&L for brick work with using flyash bricks modular size straight or curved on plan any radius in half bricks thick wall built in cm (1:4) complete all as specified and as directed. |
| 29 | M&L for stone walling of squared rubble,regular coursed, well bonded, bedded and solidly hearted, built in CM 1:4 complete all as specified and as directed. |
| 30 | M&L for raised pointing in cement mortar 1:3 to random or polygonal rubble, uncoursed or brought upto courses complete all as specified and as directed. |
| 31 | M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping, cills ,string courses, apex stone, bed plates, kerbs, bands, lintels n.exc 1.5m length etc including necessary form work, weathering, slightly rounded or chamfered angles and throating all as specified and directed. |
| 32 | M&L for 15 mm thick rendering with CM 1:4 on concrete surface finished with even and smooth without using extra cement complete all as specified and directed. |
| 33 | M&L for applying two coats of white wash on walls including preparation of newly plastered surfaces of any description complete all as specified and as directed. |
| 34 | M&L for cement concrete in surface channels and drains, type B2 1:2:4 (using 40mm graded crushed stone aggregate) complete all as specified and as direced. |
| 35 | Extra for forming fair finished drain or channel of 30cm inner girth in cement concrete using extra cement including forms moulds etc all as specified. |
| 36 | S&F factory made steel fibre reinforced (SFRC) man holes cover with frame including necessary hold fast/hooks (medium duty) of 560 mm dia or rectangular of equivalent area including fixing with CM 1:4 and not less than 50mm thickness complete all as specified and directed. |
| 37 | S&F factory made steel fibre reinforced (SFRC) man holes cover without frame including necessary hold fast/hooks (medium duty) of 560 mm dia or rectangular of equivalent area including fixing with CM 1:4 and not less than 50mm thickness complete all as specified and directed. |
| 38 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings etc complete all as specified and as directed. |
| 39 | S&F 0.50mm thick (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed. |
| 40 | S&F 0.50mm thick (including coated thickness) pre-painted pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa Plain steel sheet as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed. |
| 41 | Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in un-framed work complete all as specified and directed. |
| 42 | S&F mild steel Hollow Section work in tubular trussles, purlins, rafter, tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc, complete using ERW or induction butt welded tubes conforming IS-4963,1993 and IS-1161-1979 grade ST-240 complete all as specified and as directed. |
| 43 | S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming IS-1161-1979 grade ST-240 complete all as specified and as directed. |
| 44 | S&F Mild steel plates (Plain or chequered) as in shoe plate, base plate and gusset plates forming holes for roof frame work, trusses, rafters etc of grade Fe 410 WA complete all as specified and as directed. |
| 45 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 46 | M&L for preparation of newly steel surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide complete complete all as specified and as directed. |
| 47 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed. |
| 48 | M&L for rendering 15 mm thick plaster on concrete /wall surfaces in CM 1:3 mixed with water proofing compound complete all as specified and directed.Note: WPC shall be measured and paid separately. |
| 49 | Supply only Integral water proofing compound complete all as specified and directed. |
| 50 | M&L for applying two coats of Dr Fixit pidecrete URP in sunken floor portion of toilets & bathroom, chajja, staircase. etc by using URP + cement in the proportion of (1:1.5) and making pedicrete solution and applying by brush. Etc complete all as specified and as directed by Engineer-in-Charge. |
| 51 | M&L for coloured glazed ceramic joint free tiles area exc 0.06 sqm but n.exc 0.11 sqm and 7 to 8mm thick in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over & including 15mm thick screed bed in CM 1:6 complete all as approved and directed |
| 52 | Dismantaling of floor hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish of the premisescomplete all as specified and directed. |
| 53 | M&L for Non - skid Ceramic joint free coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in CM 1:6 complete all as approved and directed |
| 54 | M&L for glazed coloured joint free ceramic tiles 350x 250x 7 mm / 450X 350X 7mm thick, on vertical surfaces of wall such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick rendering on stone masonry surfaces or surfaces other than fair faces of brick work in CM 1:4 complete all as specified and directed. |
| 55 | Taking down cement plaster on brick or stone or concrete surfaces of wall/ceiling etc , icluding raking out joints , hacking for key, scrubbing down with water etc.complete all as specified and directed. |
| 56 | M&L for stone grit plaster to exterior wall surfaces in two layers, comprising 12 mm thick under layer cement plaster in CM 1:4 (1 cement : 4 coarse sand), furrowed with scratching tool, applying cement slurry @ 3 kg cement per sqm, and 15 mm thick top layer cement plaster in CM 1:½:2 (1 cement : ½ coarse sand : 2 marble stone chippings of 10 mm nominal size), finished in approved panels, excluding grooves, including scrubbing and washing with brushes and water to expose marble stone aggregate, complete in all respects as specified. Note: (a) Measurement and payment for grooves shall be made separately.(b) Rate includes marble stone chippings and cement of any approved colour. |
| 57 | Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 58 | Demolition of precast RCC jallies including raming of any description any in any position set in cement mortar complete all as specified. |
| 59 | S&F precast cement concrete (1:2:4) louvers and jallies 50 mm thick (measured solid) including all mouldings but excluding frame & set in CM 1:4 complete all as specified and directed. |
| 60 | M&L for precast reinforced cement concrete slab type B1, 1:2:4 ( 20mm graded aggregate ) as in landing, drain cover slab ( for manholes etc ) , chajjas , drain cover and shelves and similar articles with plain faces & set in CM 1:4 complete all as specified and directed.Note: Reinforcement shall be measured & paid separatly. Please Enable Macros to View BoQ information |
| 61 | M&L for precast reinforced cement concrete slab type B1, 1:2:4 ( 20mm graded aggregate ) as in landing, drain cover slab ( for manholes etc ) , chajjas , drain cover and shelves and similar articles with plain faces & set in CM 1:4 complete all as specified and directed.Note: Reinforcement shall be measured & paid separatly. Please Enable Macros to View BoQ information |