| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but including backing), removing rubbish off the premises, complete all as specified and/or as directed by Engr-in-Charge. |
| 2 | M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exc. 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and/or as directed by Engr-in-Charge. |
| 3 | M&L light shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles including 15 mm thick screed in cement mortar (1:4) as in floors etc., complete all as specified and/or as directed by Engr-in-Charge.Make : Johnson (Daisy SF/Gloria SF) or equivalent from Kajaria/Somany as approved by GE. |
| 4 | M&L for glazed ceramic coloured tiles in vertical surfaces of size 450x350x7mm/ 350x250x7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including rendering 10 mm thick in cement mortar (1:4) as in backing coat, complete all as specified and/or as directed by Engr-in-Charge. |
| 5 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc. laid bedded and pointed in any mortar, complete all as specified and/or as directed by Engr-in-Charge. |
| 6 | M&L for Machine cut Kota stone slab flooring 20-25mm thick over cement screed bed 20mm thick in CM 1:6, set and jointed in neat cement slurry laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, complete all as specified and/or as directed by Engr-in-Charge. |
| 7 | M&L for 20 mm thick granite stone (any type) (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite including cutting etc. and screed bed with CM (1:4) 20 mm thick for laying floor tiles, complete all as specified and/or as directed by Engr-in-Charge. |
| 8 | Demolition of cement concrete (un reinforced) in ground floors and pavings not exc. 15 cm thick (below or above ground level) and removing debris off the premises, complete all as specified and/or as directed by Engr-in-Charge. |
| 9 | M&L for Cement concrete type 1:4:8, D-2, (using 40mm graded stone aggreate) 75 mm thick as in sub -floors, sub- bases, floors and pavings etc., complete all as specified and as directed. |
| 10 | M&L sand filling under floors in foundation and for laying Interlocking paver blocks including watering and consolidation, complete all as specified and as directed by Engr-in-Charge. |
| 11 | M&L machine pressed precast concrete interlocking paver block any shape and size polished with grey cement and pigment conforming to IS 15658-2006 of 60 mm thickiness M-35 grade, complete all as specified and/or as directed by Engr-in-Charge. |
| 12 | M&L for chequred cement concrete tiles (glazed) 30cm X 30cm X 25mm thick, set, pointed & jointed in neat cement slurry in floors polished with grey cement & pigments, laid over 15mm thick cement screed base (1:6), complete all as specified and/or as directed by Engr-in-Charge. |
| 13 | M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in mass concrete and filling of foundation, complete all as specified and/or as directed by Engr-in-Charge. |
| 14 | M&L for 75 mm thick PCC 1:3:6 type C-2 (using 20mm graded stone aggregate) as plinth protection finished even and smooth with out using extra cement, complete all as specified and/or as directed by Engr-in-Charge. |
| 15 | M&L Forming Contraction (Dummy) joints 50 mm deep x 10mm wide, filled with sealing compound Grade 'A' in plinth protection, complete all as specified and/or as directed by Engr-in-Charge. |
| 16 | M&L Forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade 'A' in plinth protection, complete all as specified and/or as directed by Engr-in-Charge. |
| 17 | S&L at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not be more than 5 mm), including making drainage opening wherever required, complete all as specified and/or as directed by Engr-in-Charge. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and/or directed by Engr-in-Charge. |
| 19 | Dismantling wall/floor and ceiling boards (fiber, pulp, insulation, blankets) etc. any thickness including covered fillets and supporting members, complete all as specified and/or directed by Engr-in-Charge. |
| 20 | M&L for 9mm thick prelaminated particle board medium interior grade, prelaminated one side with decorated choice lamination & other side balancing white lamination fixed with nails to timber frame work as in wall panelling, shelves/boarding, complete all as specified and/or as directed by Engr-in-Charge. |
| 21 | All as per Srl item No 20 above, but in ceiling. |
| 22 | Dismantling framed wooden fillets, rails, posts, rafters, purlins, grids for ceiling & wall panelling etc. under 40 sqcm in section, complete all as specified and/or directed by Engr-in-Charge. |
| 23 | M&L for 2nd class soft wood clean sawn as in battens for grids of ceiling & lining fixed with nails exc 13 sqcm and not exc 25 sqcm in section, complete all as specified and directed by Engr-in-Charge |
| 24 | M&L for 2nd class soft wood clean sawn as in battens for grids of ceiling, lining or wooden flooring work fixed with nails exc 6 sqcm and not exc 13 sqcm in section, complete all as specified and/or as directed by Engr-in-Charge. |
| 25 | M&L for covered fillets of standard hard board not less than 6mm thick and up to 40mm wide and fixing with screws complete all as specified and/or as directed by Engr-in-Charge. |
| 26 | Dismantling boarding / wooden floor of any description, fixed in any position with nails, complete all as specified and/or directed by Engr-in-Charge. |
| 27 | M&L for hard wood 2nd class factory made wooden boarded floors 10mm thick and skirtings planed one side & edges tonged and grooved or rebated, including backing with thermocol sheets, over 6 micron polythylene sheeting over the concrete to minimize moisture migration from the concrete, complete all as specified and/or as directed by Engr-in-Charge. |
| 28 | Taking down cement plaster on brick/PCC block or concrete surfaces including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and/or as directed by Engr-in-Charge. |
| 29 | M&L for 15mm thick rendering on other than fair faces of block / brick work finished even and smooth without using extra cement in cement mortar 1:6, complete all as specified and as directed by Engineer-in-Charge. |
| 30 | M&L for 10mm thick rendering on fair faces of block / brick wall work finished even and smooth without using extra cement in cement mortar 1:4, complete all as specified and/or directed by Engr-in-Charge. |
| 31 | M&L for 5 mm thick rendering on ceiling finished even and smooth without using extra cement in cement mortar 1: 3 complete all as specified and/or directed by Engr-in-Charge. |
| 32 | Preparation of new plastered surfaces of ceiling of any description and applying three coats of white wash complete all as specified and as directed. |
| 33 | Preparation of new plastered wall surface of any description and applying two coats of cement base paint over a coat of chalk whiting complete all as specified and/or as directed by Engr-in-Charge. |
| 34 | Preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion including priming plastered and other surfaces with alkali resistant priming paint, complete all as specified and/or as directed by Engr-in-Charge. |
| 35 | Preparation of new / untreated wood or wooden based surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and/or as directed by Engr-in-Charge. |
| 36 | Preperation of old wooden joinery, wall & ceiling surface of any description over 10 cm in width or girth and applying one coat of synthetic enamal paint, complete all as specified and/or as directed by Engr-in-Charge. |
| 37 | M&L for preparation of old plastered wall surfaces of any description and applying one coat of oil bound distemper, complete all as specified and/or as directed by Engr-in-Charge. |
| 38 | Preparation of old plastered wall surfaces of any description and applying two coats of white wash, complete all as specified and/or as directed by Engr-in-Charge. |
| 39 | Preparation of old plastered wall surfaces of any description and applying one coat of cement based paint, complete all as specified and/or as directed by Engr-in-Charge. |
| 40 | Excavation in post holes in hard/dense soil (of similar holes) each not exc. 0.50 cum getting out and removing surplus soil to a distance not exc. 50m and making good surface, complete all as specified and/or as directed by Engr-in-Charge. |
| 41 | S&F angle iron with swan neck as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed by Engr-in-charge. |
| 42 | M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in lean concrete, mass concrete and filling of foundation, complete all as specified and/or as directed by Engr-in-Charge. |
| 43 | Fixing only chain link fencing including line wires, any mesh size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, |
| 44 | Supply only chain link MS galvanised fencing of size as directed by Engr-in-Charge. |
| 45 | S&F in repairs galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbed at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and/or as directed by Engr-in-Charge. (each line of wire to be measured). |
| 46 | S&F mild steel screw bolt 5 to 10 mm dia (machine made) with hexagonal head at one end and screwed the other, screwed end to be fitted with one washer and hexagonal nut length exc. 5cm but not exc. 10 cm long, complete all as specified and/or as directed by Engr-in-Charge. |
| 47 | Preparation of new/ previous untreated steel surface of any description over 10cm grith or width, not otherwise described with one coat of red oxide zinc chrome primer followed by two coats of synthetic enamel paint, complete all as specified and/or as directed by Engr-in-Charge. |
| 48 | Demolition of reinforced cement concrete of any description and position not otherwise specifically provided for. |
| 49 | M&L for precast cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) in landings, cover slabs (for manholes etc.), chullah hoods, chhajja, water troughs, shelves and similar articles with plain faces, set in CM 1:6, complete all as specified and/or as directed by Engr-in-Charge. |
| 50 | M&L mild steel round bars 10mm dia and over, cut to length, bent to shape required for tie bar of chain link fencing, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and/or as directed by Engr-in-Charge. |
| 51 | S&F MS rolled sections in main and cross beams, hip and jack rafters; purlins where connected to common rafters running rails and guids for sliding doors, fixed with angle cleats or other connecting plates and similar work conforming to Fe-290, Gde-E-165, complete all as specified and/or as directed by Engr-in-Charge. |
| 52 | Dismantling plain or corrugated steel/fibre sheeting of any gauge or thickness including nanital or similar pattern complete all as specified and as directed by Engr-in-Charge. |
| 53 | S&F 0.63mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with coach screws and washers in roofs, walls etc. with grade of zinc coating 275. |
| 54 | All as per Srl item No 53 above, but except sheeting. |
| 55 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and/or directed by Engr-in-Charge. |
| 56 | All as per Srl item No 55 above, but except sheeting. |
| 57 | Taking down chowkat or frame with shutters (without taking of shutters from the frame) not exc. 1.5 sqm each any type of door (wooden, aluminium & steel etc.) complete all as specified and/or as directed by Engr-in-Charge. |
| 58 | Taking down chowkat or frame with shutters (without taking of shutters from the frame) exc. 1.5 sqm each but not exc 4 sqm each any type of door (wooden, aluminium & steel etc.) complete all as specified and/or as directed by Engr-in-Charge. |
| 59 | Taking down shutters area exc. 1 sqm not exc. 2 sqm each complete all as directed by Engr-in-Charge. |
| 60 | All as per Srl item No 59 above, but area not exc. 1 sqm. |
| 61 | Hacking out old broken glass (any thickness, size, quality or description) from wooden or steel frames fixed with putty or beads, complete all as specified and/or directed by Engr-in-Charge. |
| 62 | M&L sheet glass 4.8 mm thick ordinary quality and glazing with oil putty or wooden beads in square not exc. 0.50 sqm in each pane, complete all as specified and/or as directed by Engr-in-Charge. |
| 63 | M&L sheet glass 4.8 mm thick ordinary quality and glazing with aluminium beads in square not exc 0.50 sqm in each pane, complete all as specified and as directed |
| 64 | Taking down shutters of any description area not exceeding 1 sqm each, resecuring or easing & adjusting and refixing in the same opening complete all as directed by Engr-in-charge. |
| 65 | Taking down shutters of any description area exceeding 1 sqm and not exceeding 2 sqm each, resecuring or easing & adjusting and refixing in the same opening complete all as directed by Engr-in-charge. |
| 66 | S&F powder coated anodised aluminium frames for door, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and/or as directed by the Engr-in-Charge. |
| 67 | M&L for powder coated aluminium door shutters, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, hinge type B-21 100 mm long (3 Nos) suitable handle (2 Nos), complete all as specified and/or as directed by Engr-in-Charge.Note : Glass / Wiremesh be measured separately. |
| 68 | S&F anodised aluminium window and ventilator shutters, including aluminium jali fixed in one side, side hung type without sashbars, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinges type B-21 100mm long (2 Nos) suitable handle (1 No) etc. complete all as specified and/or as directed by Engr-in-Charge.Note : Glass / Wiremesh be measured separately. |
| 69 | S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and/or as directed by the Engr-in-Charge. |
| 70 | S&F mild steel work as in hold fasts and similar work conforming to Fe-290 or Gd -E 165 complete.all as specified and as directed by the Engr-in-Chage |
| 71 | M&L PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in hold fast, bed block and like complete all as specified and as directed by the Engr-in-Charge. |
| 72 | S&F 35 mm thick 2nd class hard wood plain framed panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and/or as directed by Engr-in-Charge. |
| 73 | S&F for 40 mm thick flush shutters, solid core construction, with block board core and plywood face panels commercial type on both sides, supply and fixed to chowkats, complete all as directed by Engr-in-charge. |
| 74 | S&F for 30 mm thick 2nd class hard wood plain framed factory made glazed and skeleton window/ ventilator shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beds for securing glass etc size of members of shutters as specified in SSR part I, Section 8, clause 8.24(a) supplied and fitted to chowkats, complete all as directed by Engr-in-Charge. |
| 75 | S&F 100 mm long mild steel butt hinges, medium weight cold rolled 100mm size complete all as specified and as directed. |
| 76 | S&F 100 mm long stainless steel butt hinges, medium weight cold rolled 100mm size complete all as specified and as directed. |
| 77 | S&F 150 mm long aluminium anodized, barrel tower bolt of extruded section, complete all as specified and/or as directed by Engr-in-Charge. |
| 78 | S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and/or as directed by Engr-in-Charge. |
| 79 | S&F 250 mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed, complete all as specified and/or as directed by Engr-in-Charge. |
| 80 | S&F in repairs steel rolling shutters 1.00 mm thick, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shope coat of primer; erected in position, complete all as specified and/or as directed by Engr-in-Charge. |
| 81 | S&F in repairs safety lever locks mild steel with 4 levers for rolling shutters. |
| 82 | S&F 25 mm dia 3 layer PP-R polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete all as per manufacturer's instructions and as directed by Engr-in-Charge including taking up or down 25 mm bore steel tubing / PPR pipe and connections and set aside for re-use or removal to store. |
| 83 | S&F 32 mm dia 3 layer PP-R polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete all as per manufacturer's instructions and as directed by Engr-in-Charge including taking up or down 32 mm bore steel tubing / PPR pipe and connections and set aside for re-use or removal to store. |
| 84 | S&F in repair 25 mm outer dia PPR gate valve (brass insert) conforming to ISO 2000 high pressure with epoxy coated aluminium rod and high density plastic ball screwed for PPR pipe or for union and fixed as per requirement of site complete all as specified and directed by the Engr-in-Charge. |
| 85 | S&F in repair 32 mm outer dia PPR gate valve (brass insert) conforming to ISO 2000 high pressure with epoxy coated aluminium rod and high density plastic ball screwed for PPR pipe or for union and fixed as per requirement of site complete all as specified and directed by the Engr-in-Charge. |
| 86 | S&F 250 litres capacity rotational moulded polyethylene water storage tank inner and out white, two layers ISI marked (cylindrical vertical, with closed top), hoisted with threaded cap and fixed in position all as specified in SSR Part I including all accessories (i.e. GI nipple etc.), including provn of 20/25 mm dia spout for connecting inlet, outlet, over flow and washout pipes and including dismantling existing water tank and removing to store, complete all as specified and/or as directed by Engr-in-Charge. |
| 87 | S&F 500 litres capacity rotational moulded polyethylene water storage tank inner and out white, two layers ISI marked (cylindrical vertical, with closed top), hoisted with threaded cap and fixed in position all as specified in SSR Part I including all accessories (i.e. GI nipple etc.), including provn of 20/25 mm dia spout for connecting inlet, outlet, over flow and washout pipes and including dismantling existing water tank and removing to store, complete all as specified and/or as directed by Engr-in-Charge. |
| 88 | S&F 1000 litres capacity rotational moulded polyethylene water storage tank inner and out white, two layers ISI marked (cylindrical vertical, with closed top), hoisted with threaded cap and fixed in position all as specified in SSR Part I including all accessories (i.e. GI nipple etc.), including provn of 20/25 mm dia spout for connecting inlet, outlet, over flow and washout pipes and including dismantling existing water tank and removing to store, complete all as specified and as directed by Engr-in-Charge. |
| 89 | S&F rotational moulded HDPE water storage tank 500 ltrs capacity, PUF insulated with 75 mm thick PUF insulation of density 48 kg/Cum inner and out white two layers ISI marked (cylindical vertical type/rectangular loft type closed top) hoisted with threaded cap and fixed in position all as specified in SSR Part I including all accessories (i.e. GI nipple etc.), including provn of 20/25 mm dia spout for connecting inlet, outlet, over flow and washout pipes and including dismantling existing water tank and removing to store, complete all as specified and as directed by Engr-in-Charge. |
| 90 | S&F rotational moulded HDPE water storage tank 1000 ltrs capacity, PUF insulated with 75 mm thick PUF insulation of density 48 kg/Cum inner and out white two layers ISI marked (cylindical vertical type/rectangular loft type closed top) hoisted with threaded cap and fixed in position all as specified in SSR Part I including all accessories (i.e. GI nipple etc.), including provn of 20/25 mm dia spout for connecting inlet, outlet, over flow and washout pipes and including dismantling existing water tank and removing to store, complete all as specified and as directed by Engr-in-Charge. |
| 91 | S&F in repair 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210gms), complete all as specified and as directed by Engr-in-Charge. |
| 92 | S&F in repair 25 mm outer dia PPR ball valve (brass insert) conforming to ISO 2000 high pressure with epoxy coated aluminium rod and high density plastic ball screwed for PPR pipe or for union and fixed as per requirement of site complete all as specified and directed by the Engr-in-Charge. |
| 93 | S&F in repairs fancy type 15 mm bore chromium plated bib taps, cast copper alloy, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed. |
| 94 | S&F 15 mm bore pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and as directed. |
| 95 | S&F in repairs 20mm dia stop valves, fancy type chromium plated with long shank and cast copper alloy (concealed type), screwed down high pressure screwed both ends for iron pipes complete all as specified and/or as directed by Engr-in-Charge. |
| 96 | S&F in repair fancy type, chromium plated 20 mm bore angle valves, cast copper alloy screwed down high pressure, screwed both ends for iron pipe or for unions, complete all as specified and/or as directed by Engr-in-Charge. |
| 97 | S&F in repair 15 mm bore dia bib tap of PTMT any color high pressure screwed for iron pipe and fixed complete all as specified and as directed (min weight - 90 gms), complete all as specified and/or as directed by Engr-in-Charge. |
| 98 | S&F in repair 15 mm bore stop valve standard of PTMT any color high pressure screwed for iron pipes and fixed at position, complete all as specified and as directed (min weight - 90 gms), complete all as specified and/or as directed by Engr-in-Charge. |
| 99 | S&F in repair 15 mm bore angle stop valve standard of PTMT any color high pressure screwed for iron pipes and fixed complete all as specified and as directed (min weight 15mm 90 gms). |
| 100 | S&F in repairs 750 mm long, 32/40 mm dia, PVC plain waste pipe for sinks / wash hand basins complete all as specified and directed. |
| 101 | S&F vitreous china wash basin fancy type pedestal pattern, white, flat back, size 550 x 400mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, complete all as specified and/or directed by Engr-in-Charge. |
| 102 | S&F in repairs vitreous china squatting pan or orissa pattern 580 x 440 mm white with integral foot rest (excluding cistern and flush pipe) but including connection to 100mm dia trap 'P' or 'S' anti syphonage pipe etc complete all as specified and as directed by Engr-in-Charge. Make : Cera / Jaquar or equivalent as approved by GE. |
| 103 | S&F 15 mm bore, PVC connection pipe 600 mm long with PTMT nuts at both ends, complete all as specified and as directed. |
| 104 | S&F 15 mm bore, PVC connection pipe 450 mm long with PTMT nuts at both ends, complete all as specified and as directed. |
| 105 | S&F in repairs, 10 litres capacity PVC valveless symphonic action type, flushing cistern (ISI marked), low level, white, with inlet, ball valve, float and handle including bracket & flush pipe of polyethylene of low or high density or high density or PVC, 32 mm dia, for low level cistern, complete all as specified & directed by Engr-in-charge. |
| 106 | S&F in repairs, PVC (SWR) 75 mm dia, floor trap, plain with grating including jointing to waste pipe with solvent cement complete all as specified & directed. |
| 107 | S&F in repair acrylic PVC bathroom cabinet of size 550 x 400 mm with openable shutter fixed with looking mirror of selected quality and with suitable shelves inside the cabinet of superior quality as specified and directed by Engr in Charge. |
| 108 | S&F in repair 600 x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and/or directed by Engr-in-Charge. |
| 109 | S&F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges, complete all as specified and/or directed by Engr-in-Charge. |
| 110 | S&F in repair CP floor gratings 150 mm dia all as specified and/or as directed by Engr-in-Charge |
| 111 | S&F vitreous china urinal half stall type, white complete including providing and fixing plugs, bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60 mm brass screws, pointing around urinal back in cement, fixing grating and union for discharge pipe excluding flushing cistern, flush pipe but including CP waste coupling, PTMT urinal spreader, etc. complete all as specified and as directed by the Engr-in-Charge. |
| 112 | S&F Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and/or as directed by Engr-in-Charge. |
| 113 | Demolition of precast concrete block walling built in cement mortar including all quoins, arches, pillars etc. complete all as specified and/or directed by Engr-in-Charge. |
| 114 | M&L precast solid blocks in cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in block masonry, exc.10 cm in width and set in cement mortar 1:6, complete all as specified and/or directed by Engr-in-Charge. |
| 115 | All as per Srl item No 114 above, but except blocks. Please Enable Macros to View BoQ information |