|
| 1 | Operation & maintenance of water supply pump sets, 20 KVA D.G. set, street lighting and IEI of pump houses at 112 LIG houses at Ashok Nagar along Faiz Road Karol Bagh, as per inventory and terms & conditions enclosed herewith . |
| 2 | Servicing and preventive maintenance of 20 KVA D.G. set i/c supply & replacement of mobile oil, coolant, air filter, diesel filter, oil filter i/c testing, commissioning etc. complete as required. |
| 3 | Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20 mm) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver& electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). etc complete as req along with dismantaling of existing including buyback.a) 18-22W (4feet long) |
| 4 | Supply of one number PVC insulated and PVC sheathed / XLPE copper Al armoured power cable of 1.1 KV grade of following size in the existing masonry open duct / GI Pipe / Cable tray etc as per site requirement. Complete as required as per specification and as per direction engineer-in-charge. |
| 5 | 2 C X 10 sq. mm Al Armoured |
| 6 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.a) upto 35sqmm. (clamped with 1mm thick saddle) |
| 7 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). A ) 25 watt |
| 8 | Rewinding & repairing of 12.5 HP motor pumps set with suitable size &guage of copper winding i/c replacement of defective ball bearing terminal plate copper thimble replacement of worn-out parts bearing and shaft twisting i/c cartageto& ro. Loading unloading to workshop i/c dismantling reassembling i/c cartage to and fro. testing on load etc. complete as reqd. at site. Please Enable Macros to View BoQ information |