Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | 1. SH: Operation and Maintenance of E.I, Pumps, Fire Alarm System, Fire Fighting System, CCTV, EPABX, STP, RO Plant and RO System, Mixed Oxidant Plant and various other services installeld at Lal Bahadur Shastri Hospital.(Maintenance of EI & Fans): a.Operation, Routine and preventive Maintenance and Upkeepment of all internal electrical and external installations such as light point, power point, circuit, sub & main distribution boards, switch boards, various electrical fittings, All type fans, Light, Gysers, cables/ Wires, thimbles, glands, compound/street lights internal & external cabling etc including recording and monitoring of the complaints on all days including sundays and holidays by providing following minimum staff as per details of staff (round the clock or in general shift as and when required as per direction of Engineer-in-Charge), terms and conditions and inventory attached including consumables materials such as PVC tape, screw etc but excluding E&M installations. Services of khallasi shall be used as per direction of Engineer-In-Charge.Location:- LBS Hospital(a) Wireman - 1 No. (In General Shift)(b) Khallasi - 1 No. (In General Shift) |
| 2 | Operation, Routine and preventive Maintenance and Upkeepment of all internal electrical and external installations such as light point, power point, circuit, sub & main distribution boards, switch boards, various electrical fittings, All type fans, Light, Gysers, cables/ Wires, thimbles, glands, compound/street lights internal & external cabling etc including recording and monitoring of the complaints on all days including sundays and holidays by providing following minimum staff as per details of staff (round the clock or in general shift as and when required as per direction of Engineer-in-Charge), terms and conditions and inventory attached including consumables materials such as PVC tape, screw etc but excluding E&M installations. Services of khallasi shall be used as per direction of Engineer-In-Charge.Location:- LBS Hospital(a) Wireman - 3 Nos. (1 No. in Each Shift)(b) Khallasi - 3 Nos. (1 No. in Each Shift) |
| 3 | (Operation of DG Set and Sub-Stations)Round the clock Operation, Routine and preventive Maintenance and Upkeepment of 1 No. 750 KVA, DG sets of Cummins make, Transformer- 2 Nos. 1250 KVA TMC Make including AMF panel, LT panel, capacitor panel etc installed at LBS Hospital, New Delhi round the clock on all days of the week i/c Sundays and Holidays complete as per terms and conditions and details of minimum staff (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and inventory attached.Minimum requirement of manpower LBS Hospital(a) Wireman cum operator - 3 Nos. |
| 4 | (Operation of Passenger Lifts)Round the clock Operation, Routine and preventive Maintenance and Upkeepment of the 1 No. Hospital Bed lift OTIS Make and register the complaint regarding any fault in lift, to concern agency and to department without delay so that lift remains in working condition all the time. by providing following mimimum staff as per details of staff (round the clock or in general shift as and when required as per direction of Engineer-in-Charge), terms and conditions and inventory attached. on all days i/c Sundays and holidays. Services of khallasi shall be used as per direction of Engineer-In-Charge.Location :- LBS Hospital(a) Lift Operator - 3 Nos. (b) Khallasi - 1 No. |
| 5 | (Operation of Fire Fighting, Wet Riser System, sprinkler, hydrant, portable fire extinguishers and Water Supply Pumps)Round the clock Operation, Routine and preventive Maintenance and Upkeepment of fire fighting system at LBS Hospital by deloying following staff for fire pump and all equipments, on all days i/c Sunday & holidays (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and as per terms & conditions and inventory attached etc complete as reqd. Services of khallasi shall be used as per direction of Engineer-In-Charge.Location:- LBS Hospital(a) Skilled (Fireman)-3 Nos.(b) Unskilled (Khallasi)-1 No. |
| 6 | (Operation of Fire Alarm System and PA System)Round the clock Operation, Routine and preventive Maintenance and Upkeepment of fire alarm system including panel and other accessories etc. installed at OPD Block, Wards, ICUs, OTs, Admin Branch at LBS Hospital, round the clock on all days of the week including Sundays and Holidays complete as per terms and conditions and details of minimum staff (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and inventory attached.Location:- LBS Hospital (a) Skilled(Operator)- 3 Nos. |
| 7 | (Operation of HVAC)Operation of (140 TR - 3 Nos.) central AC plant & Hot water Generator system on all days i/c Sunday & holidays (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and as per terms & conditions and inventory attached etc complete as required. (As per enclosed terms & conditions) Services of khallasi shall be used as per direction of Engineer-In-Charge.Location:- LBS Hospital (a) AC Mechanic cum technician - 3 Nos. (b) Unskilled (Khallasi)- 2 Nos. |
| 8 | (Operation of RO system, RO Plant & water softening plant & operation of 125 KLD STP/ETP Plant)a). Operation of 1000 LPH 2 Nos. RO Plant, Equa pro make mixed oxidant based plant 2 Nos. and pump sets on all days i/c Sunday & holidays (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and as per terms & conditions and inventory attached etc complete as required.b). Operation of 125 KLD MBBR Technology base STP plant on all days i/c Sunday & holidays (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and as per terms & conditions and inventory attached etc complete as required with providing following minimum staff.Location:- LBS Hospital & Residential Quarters(a) Skilled (Operator )- 3 Nos.(b) Unskilled (Khallasi)- 1 No. |
| 9 | Operation of Various Delhi Govt. Dispensary/ Ayushman Arogya Mandir/Veterinary Hospital:-Providing services of following staff for Govt. Dispensary/ Ayushman Arogya Mandi day to day maintenance of electrical installation, street light, Panel and other electrical accessories at each of following buildings excluding Sundays & holidays (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) as per terms & conditions and inventory attched etc complete as reqd.Staff to be deployed.Location:- Mayur Vihar Phase-I, Shashi Garden, Kondli, Vashundra, I.P. Extension, Kalyanvas, Ghazipur.a) 1 No. Wireman b) 1 No. Khallasi |
| 10 | EPBAX SystemComprehensive maintenance & services of Electronic Private Automatic Exchange having 8 lines with all the standard features and maintenance of push button telephone intercom instruments upto 8 nos. i/c replacement of all spare parts/components as and when required ( At sub division office) - 1 Job. |
| 11 | Comprehensive maintenance & services of Electronic Private Automatic Exchange having 16 lines with all the standard features and maintenance of 10 no. push button telephone instruments i/c replacement of minor spare parts/components as and when required ( At Sub division office and Mayur Vihar Phase 1 ) - 2 Jobs. |
| 12 | Comprehensive Maintenance of Mixed Oxidant PlantSupplying, cleaning of Regenerating chemical for Aquapro make water softening plant & its allied accessories at LBSH, which includes charging of water softening Plant with brine (Solution of common grade industrial salt) Qty: 60 Kg/Charging at periodic intervals i.e. 26 times a month to keep the output hardness of water within acceptable limits. The averaged requirement of charging shall be app. 26 per Month. It shall be within the scope of work to replace any component/ part/ chemical that may be the part of water softening system but not mentioned above. The Chemical to test the Raw water soft water before & after charging are including in the scope of work. (1560 Kg per Month) |
| 13 | Supply and replacement of strongly Acidic Cationic Resin to the pressure vessel of softner for processing of water. AQUAPRO MakeCapacity :20 Cu.m/Reg Quantity :400 Ltrs. |
| 14 | Comprehensive Maintenance of LANComprehensive Maintenance of Juniper make Networking System & LAN System i/c all services, cleaning for checking repair & replacement of minor/major defective parts of with following scope of work:1) Juniper Network Layer 3 10/100/1000-24 ports Giga Edge Switches 2 nos., 2) Juniper 10/100/1000-24 ports Giga Edge Switches 15 nos., 3) Fortigate Firewall system : 01 Nos4) Cisco Network Router : 01 Nos 5) Poweride Network 9 U Racks,: 08 Nos6) Poweride Network 32 U Rack: 01 Nos7) D-link SFP Modules 25 Nos, 8)D-link Jack Panel 10 Nos, 9) D-link SM 6 port LIU : 06 Nos10) D-link SM 12 port LIU : 04 Nos 11 D-link SM 24 Port LIU : 02 Nos 12) CAT-6 Low Smoke UTP cable: 8000 Mtrs 13) Schneider 6 core OFC cable : 650 Mtrs 14) D-link 1mtrs &2 Mtrs UTP Low Smoke Patch Cords : 345 Nosalong with all accessories Excluded Plastic Trunking & Earthing Except Force Damage. -01 Job |
| 15 | AMC & Routine and Repair Maintenance of 2X1000 LPH RO Plant and RO with Inbuilt water cooler/dispenser systemAnnual comprehensive maintenance contract of ICON Make RO plant 2x1000 LPH capacity installed at LBSH including all electrical and electronics spares i.e. starter, rotameter, MCB, pH meter, TDS meter, washing, rinsing of sand filter, rinsing of activated carbon filter, one time replacement of appropriate quantity of gravels & pebbles of all sizes, multiport valve, all pipe fittings, dosing pumps, electronic panels i/c overhauling of pump sets, replacement of bearing, replacement of water seals, gasket, replacement of damaged pipe lines and its accessories etc. as required to make RO plant to work smoothly and satisfactorily every month. (Consumable to be replace as and when required after expiry of the working life will be extra) |
| 16 | Annual Comprehensive Maintenanace of Water Cooler with inbuilt RO +UV of with capacity 150 Ltr Storage Capacity and 150 ltr cooling capacity with 100 LPH RO System connected with water tank consisting of three mandatory Services, Repair/Replacement of all electrical and electronic spare parts like Speed Pump , Solenoid Valve, high pressure Switch, SMPS, adoptor and Attending complaints within 24 working hours with complete overhauling and servicing etc as reqd. (15 Nos. For 24 Months) |
| 17 | Annual Maintenance Contract of Hot , Cold & Normal Water Dispenser with inbuilt RO+UV with system Connected with storage tank consisting of three Mandatory Services, Repair/Replacement of all Electrical and Electronic Spare parts like Pump , SMPS, Adaptor , Solenoid Valve and High Pressure Switch and attending complaints within 24 working hours with complete overhauling and servicing etc as reqd (26 Nos. For 24 Months) |
| 18 | Sub Head-III Miscellaneous worksEI WorkWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.a) Group A |
| 19 | b) Group C |
| 20 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. A) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 21 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 22 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 23 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 24 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.A) Group A |
| 25 | b) Group C |
| 26 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required |
| 27 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 28 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 8 way, Double door |
| 29 | 12 way, Double door |
| 30 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)A) 4 way (4 + 12), Double door |
| 31 | 8 way (4 + 24), Double door |
| 32 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phaseoutlets are required.)A) 12 way (4 + 36), Double door |
| 33 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.A) 63 mm dia (OD-63 mm & ID-51 mm nominal |
| 34 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL/ DWC pipe as required. A) Upto 35 sq. mm |
| 35 | Above 35 sq. mm and upto 95 sq. mm |
| 36 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required.A) Upto 35 sq. mm |
| 37 | Above 35 sq. mm and upto 95 sq. Mm |
| 38 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. A) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 39 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 40 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.A) 150 mm width X 50 mm depth X 1.6 mm thickness |
| 41 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 42 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.A) 1 run of cable |
| 43 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 44 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 45 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 46 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.A) 2 X 2.5 Sq. Mm |
| 47 | 3 X 2.5 Sq. mm |
| 48 | 3 X 6 Sq. mm |
| 49 | 2 X 6 sq. mm (19mm) |
| 50 | 2 X 10 sq. mm (19mm) |
| 51 | 3 X 10 sq. mm (22mm) |
| 52 | 3 X 16 sq. mm (25mm) |
| 53 | 3½ X 25 sq. mm (28mm) |
| 54 | 3½ X 35 sq. mm (32mm) |
| 55 | 3½ X 50 sq. mm (35mm) |
| 56 | 3½ X 70 sq. mm (38mm) |
| 57 | 3½ X 95 sq. mm (45mm) |
| 58 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.A) 3 X 16 sq. Mm |
| 59 | 3½ X 25 sq. mm |
| 60 | 3½ X 35 sq. mm |
| 61 | 3½ X 50 sq. mm |
| 62 | 3½ X 70 sq. mm |
| 63 | 3½ X 95 sq. mm |
| 64 | 3½ X 120 sq. mm |
| 65 | 3½ X 185 sq. mm |
| 66 | 3½ X 240 sq. mm |
| 67 | 3½ X 300 sq. mm |
| 68 | 3½ X 400 sq. mm |
| 69 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :A) 240 sq. Mm |
| 70 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :A) 240 sq. Mm |
| 71 | B) PUMP WORKSDisconnecion & Lifting of following capacity Submersible pump set from the borewell along with GI pipe, Cable with the help of Chain pulley and tripod stand i/c disconnection of pipe , cable etc. complete as reqd (Upto 160 Ft).A) Upto 7.5 HP |
| 72 | Disconnecion & Lifting of following capacity burntout / defective Openwell Submersible pump set from the UG Tank along with GI pipe, Cable with the help of Chain pulley and tripod stand i/c disconnection of pipe , cable etc. complete as reqd.A) Upto 25HP |
| 73 | Connecion & Lowering of following capacity Repaired/ rewinding Openwell Submersible pump set from the UG Tank along with GI pipe, Cable with the help of Chain pulley and tripod stand i/c disconnection of pipe , cable etc. complete as reqd.A) Upto 25HP |
| 74 | Lowering of various Capacity Submersible pump set in the existing borewell along with GI pipe, Holding Wire, Cable with the help of Chain pulley and tripod stand i/c clipping the Holding wire & Cable etc. complete as reqd. (Upto 160 ft)A) Upto 7.5 HP |
| 75 | Repairing & Rewinding of following capacity submersible borewell pump motor with replacement of all defective accessories i/c dismantalling, reassembling complete as reqd.A) Upto 5HP |
| 76 | Repairing & Rewinding of following capacity openwell submersible/monoblock pump motor with replacement of all defective accessories i/c dismentaling, reassembling complete as reqd.A) Upto 5 HP |
| 77 | Above 5 HP and Upto 7.5 HP |
| 78 | Above 7.5 HP and Upto 25 HP |
| 79 | Fabricating, Supplying and Fixing of following sizes, C-class G.I pipe with heavy duty GI flanged both side i/c rubber packing Nuts and bolts complete including anticorrosive paint on thread portion and cutting drilling hole in flange welding to avoide rusting etc. as reqd.A) 50 mm dia GI Pipe |
| 80 | Supplying & fixing of following sizes flate type submersible cable with clamps along with delivery line i/c dismantling the existing defective submersible cable & buy back of defective submersible cable etc. as required.A) 3 X 2.5 Sq. mm Submersible Cable (Copper conductor) |
| 81 | 3 X 10 Sq. mm Submersible Cable (Copper conductor) |
| 82 | Supplying, installation, testing and commissioning of following capacity fully automatic star delta starter suitable for Monoblock/Submersible Pump with Ameter & Single Phasing , Low Voltage, High Voltage Protectioni/c proper connectioning with tsuitable size copper thimbles including dismantling the existing burnt out stater etc. as required.A) 5 HP Fully Automatic Star Delta Starter |
| 83 | 7.5 HP/10 HP Fully Automatic Star Delta Starter |
| 84 | 20/25 HP Fully Automatic Star Delta Starter |
| 85 | C) Supply of Materials Supply & testing of following material / accessories for using existing man power for replacement on day to day maintenance work:A) 5 Amp Modular Switch |
| 86 | 5 Amp Modular Socket |
| 87 | 15/16 Amp Modular Switch |
| 88 | 15/16 Amp Modular Socket |
| 89 | 16 Amp SP MCB |
| 90 | 25 Amp SP MCB |
| 91 | 32 Amp SP MCB |
| 92 | 16 Amp DP MCB |
| 93 | 32 Amp DP MCB |
| 94 | 32 Amp TP MCB, 10kA breaking capacity |
| 95 | 32 Amp TPN MCB, 10kA breaking capacity |
| 96 | 63 amp 4 pole Isolator |
| 97 | 100 amp 4 pole Isolator |
| 98 | Modular switch type regulator stepped |
| 99 | 100 A, 16 kA, TPMCCB |
| 100 | Modular bell push, ISI marked |
| 101 | Modular base and cover plate for 2 module |
| 102 | Modular base and cover plate for 3 module |
| 103 | Modular base and cover plate for 4 module |
| 104 | Modular base and cover plate for 6 module |
| 105 | Modular base and cover plate for 8 module |
| 106 | Modular base and cover plate for 12 module |
| 107 | 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper condutor cable |
| 108 | 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper condutor cable |
| 109 | 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper condutor cable |
| 110 | Modular GI Box for 3 Module |
| 111 | Modular GI Box for 6 Module |
| 112 | Modular GI Box for 8 Module |
| 113 | Modular GI Box for 12 Module |
| 114 | Heat Detector of electronic rate of rise cum fixed temprature (Dual Thermistor) type with mounting base complete with all connection etc. |
| 115 | Smoke Detector with build in LED mounting base complete with all connection etc. |
| 116 | Supplying and testing of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect with Minimum 5 years OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)A) 18- 22 watt |
| 117 | 40 watt |
| 118 | Supplying & testing of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim .a) 12 -15 watt |
| 119 | Supplying & Testing of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).A) 50 Watt |
| 120 | Supplying & Testing of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).A) 100 watt |
| 121 | 200 watt |
| 122 | Supplying & testing of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)A) 36 watt |
| 123 | Supply & testing of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.A) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min(Minimum) |
| 124 | Supplying of 300/400 mm Sweep wall mounted oscillating Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc.as reqd. |
| 125 | Supply of 300 mm (Heavy duty) sweep exhaust fan 900 RPM in the existing opening including making good the damages, connection testing and commissioning etc. complete and dismantling etc. as required. |
| 126 | Supply of 250 mm sweep exhaust fan plastic body with Dust Proof Body and Dust Protection Shutters in the existing opening including making good the damages, connection testing and commissioning etc. complete and dismantling etc. as required. |
| 127 | (D) HVAC WorkComplete servicing of WTAC/STAC unit of 1.5 / 2.0 Tr capacity including dismantling the AC from its existing position i.e. various OPD's, Wards, ICU, OTs and various DA Dispensaries/Polyclinics etc, cleaning of evaporative and condensing coil with suitable chemical like coil cleaner, greasing of motor, cleaning of drain pipe and refixing the same on its existing position complete etc. as required. (For Two Years) |
| 128 | Supplying & Charging of R-410a/R-22/R-32 refrigerant gas in existing following capacity WTAC / STAC unit i/c replacement of capillary tube & strainer, pressure testing, vaccumising, testing etc. complete as reqd. (For Two years) (A) 1.5 TR capacity |
| 129 | 2 TR capacity |
| 130 | Supplying & replacement of following capacity reciprocating/rotary type hermetically sealed compressor complete in the existing WTAC & STAC unit i/c repairing / rejoining of copper pipes, testing etc. as reqd.A) 1.5 TR capacity |
| 131 | 2 TR capacity |
| 132 | Supplying, Installation, testing and commissioning of following capacity condenser coil in the existing WT /Split type AC i/c breezing the copper piping and fitting with screws, pressure testing & gas charging etc. as required at site.A) a) 1.0/1.5 TR Condenser coil |
| 133 | b) 2.0 TR Condenser coil |
| 134 | Supplying, Installation, testing and commissioning of following capacity cooling coil in the existing WT /Split AC unit complete with brazing the copper piping, pressure testing & gas charging etc. as required at site.a) 1.0/1.5 TR Cooling coil |
| 135 | b) 2.0 TR Cooling coil |
| 136 | Supplying and fixing 25 mm flexible drain pipe suitable for split and window AC units complete with necessary clamping on wall/floor for support etc. as per site requirement. |
| 137 | Supplying and laying of one number XLPE insulated and FR PVC round sheathed, un-armoured, Copper conductor power cable of 1.1 KV grade conforming to IS: 694 of following sizes for electrical connection of indoor and outdoor units for extend Main Supply of 1.5/2.0 TR Split Type AC as required.a) 4 X 2.5 Sq. mm |
| 138 | Repairing of PCB of remote control unit in the existing 2 TR/1.5TR Cap. STAC (Invertor Type)/WTAC of various makes i/c dismantling existing worn out PCB, connection, testing & buy back the old etc. as reqd. (as per sample)a) 1.0/1.5/2.0 TR Invertor Type |
| 139 | Replacement ( New PCB ) of PCB of remote control unit in the existing of 2 TR/1.5TR Cap. STAC (Invertor Type)/WTAC of various makes i/c dismantling existing worn out PCB, connection, testing etc. as reqd. (as per sample)a) 1.0/1.5/2.0 TR Invertor Type |
| 140 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as requiredA) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 141 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 142 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 143 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).a) 2.0 TR with 5 Star BEE Rating |
| 144 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).a) 1.5 TR with 5 Star BEE Rating |
| 145 | Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate up to 50 0C (out door ambient temperature).a) 1.5 TR with Inverter 5 Star BEE rating |
| 146 | SITC of following KVA capacity single phase, 230 volts, automatic voltage stabilizer complete with high-low cut off and time delay relay etc as required.a)2.0 TR AC Stablizer range 130-280V |
| 147 | b)1.5 TR AC Stablizer range 170-270V |
| 148 | (E) Fire Fighting SystemProviding laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.A) 150 mm. Dia |
| 149 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required.A) 150 mm dia |
| 150 | 100 mm dia |
| 151 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :a) Single headed Stainless steel |
| 152 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required.a) Single headed Stainless steel |
| 153 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve & nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.a) 30 m |
| 154 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :a) Stainless Steel (Grade 304) |
| 155 | (F) Fire Alarm SystemSupplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.A) 6 zone panel. |
| 156 | 4 zone panel. |
| 157 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 158 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 159 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 160 | Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 161 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 162 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 163 | (G) 2X1000 LPH RO Plant, RO with Inbuilt water cooler/dispenser systemRepair/ Replacement & Major Maintenance Work 2X1000 LPH RO Plant, RO with Inbuilt water cooler/dispenser systemReplacement of 4\\" X 40\\" RO Membrane |
| 164 | Replacement of Big Blue Micro Filters of dia 20\\" X 4\\" up to filtration of 5 Micron. |
| 165 | Replacement of Micro Filters Bag of dia 20\\" X 4\\" up to filtration of 5 Micron |
| 166 | Antiscalent Chemical |
| 167 | Supplying and Replacement of Following Spare/Components in the exisiting water Dispenser & Water Cooler with inbuilt RO+UV etc as reqd. TFC Cartridge 1812 (For 26 Nos. dispenser X 2 Each in 4 Months) |
| 168 | TFC Cartridge 4021 (For 15 Nos. RO+Water Cooler X 2 Each in 4 Months) |
| 169 | Particulate Filter 20\\" (For 26 Nos. RO+Water Cooler X 2 Each in 4 Months) |
| 170 | Activated Carbon 20\\" (For 26 Nos. RO+Water Cooler X 2 Each in 4 Months) |
| 171 | Particulate Filter 10\\" (For 26 Nos. dispenser 1 each in 4 Months) |
| 172 | Activated Carbon 10\\" (For 26 Nos. dispenser 1 each in 4 Months) |
| 173 | Alkaline Filter (For 15 Nos. RO+Water Cooler X 1 Each in 4 Months) |
| 174 | Alkaline Filter for dispenser (For 26 Nos. dispenser 1 each in 4 Months) |
| 175 | Supplying and Charging of R 134 Gas charging in the water Dispenser with inbuilt water purifier after pressure testing leak detection and rectified the breakage (if any) testing and commissioning etc as reqd. |
| 176 | Supplying and Charging of R 134 Gas charging in the water Cooler for 150/150 with inbuilt water purifier after pressure testing leak detection and rectified the breakage(if any ) testing and commissioning etc as reqd. |
| 177 | (H) Routine and Repair Maintenance WorkProviding and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 16 KA, TPMCCB |
| 178 | 200 A, 25 KA, TPMCCB, |
| 179 | 250 Amp, 35 KA, TPMCCB |
| 180 | 400 Amp, 35 KA, TPMCCB |
| 181 | (I) STP/ETPSupply and Doosing of Bio-Enzymatic culture for Biological treatment available in powder from a special waste treating microbes along with enzymes. Bio-Enzymatic solution of aerobic and anaerobic bacteria count of each not less than 8x10^9 CFU/mg (Brands : DIGESTOR, EnSafe , EcoSanG) |
| 182 | (J) Water CoolerSITC of 150 Liters/Hr cooling capacity with inbuilt 150 Liters Per Hour RO Purification System with auto sanitization with min.7 stage purifications & storage capacity of 150 LTR :Cooling Water Storage Capacity. : 150 LtrWater Cooling Rate 150 LPHWater Inlet Cooling Adjustment Temperature: 13.5 °C AdjustableNo. Of Faucets : 2 COLDWater Recovery: More than 70%Outer Body Material- Tank/Cooler: SS204 cuStorage Tank/Cooler Material : SS304 food grade or betterRefrigerant : R-134 A or equivalentOperating Voltage :230+-10% V AC,50 HzPower Consumption: Max. 1.7 KWRO Purification SystemType of water purification technology: RO + EPS/ESSPurification Capacity. : Min.150 Liters/HourPurification Stages : Min Seven stage filtration processSediment Filter: Dedicated 10 micron 20\\" filterCarbon Filter: Activated Carbon Block- 10 micron 20\\" filterWater Saver Cartridge: 20” Nova CartridgeTaste Enhancer Cartridges: PH Correction CartridgeRO Membrane: 300X 3 + 100X 1 GPDTaste Enhancer cartridge: PH correction cartridgesAuto Sanitzer – Storage tank : ESS – protect tank water from bacterial growthPurification Stages : Min 7 stage filtration process with required Technology. |
| 183 | Water testing after collection of water samples from the site directly by the NABL accredited lab or any Govt. authorized lab complete with the following tests conforming to IS : 10500 2012 for drinking water complete as reqd:-(A) Chemical Test1). Colour, Hazen Unit2). Output3). Taste4). Turbidity, NTU5). pH Value6). Total Hardness (as CaCO3) mg/l7). Iron (as Fe), mg/l8). Chlorides (as Cl), mg/l9). Total Dissolved Solid, mg/l10. Fluoride (as F), mg/l(B). Bacteriological Test1). E.Coli or thermotolerant Coliform bacteria2). Total Coliform bacteria |
| 184 | Dismantle MaterialsDismantling of following wornout materials from existing position and credit under buy back :Assorted size of SPN DB |
| 185 | Assorted size of TPN DB |
| 186 | Assorted size 16/32/40/63 amp DP MCB/RCCB |
| 187 | Assorted size 6/10/16/32 amp SP MCB |
| 188 | Assorted 5 Amp/16 amp Modular Switch/Piano Switch/Modular bell push |
| 189 | Assorted 5 Amp/16 amp Modular Socket/Piano Socket |
| 190 | Assorted modular/piano type regulator |
| 191 | Assorted 1200/1400 mm ceiling fan |
| 192 | Assorted 100 amp TPN MCB |
| 193 | Assorted 125 amp/200 TPMCCB |
| 194 | Assorted 250 amp/400 TPMCCB |
| 195 | NRV of 150 mm/100 mm |
| 196 | Sector Panel of 10/6/4 Zone |
| 197 | Assorted RI/Smoke/Heat Detector |
| 198 | Assorted Fire Alarm Sounder/MCP |
| 199 | Internal/External Hydrant Valve |
| 200 | 2. SH: Operation and Maintenance of E.I, Pumps, Fire Alarm System & PA System, Fire Fighting System, CCTV, EPABX, PA System, NCS, STP/ETP, Solar Hot Water Generator various other services installed at 460 bedded MCH Block at Lal Bahadur Shastri Hospital. (Maintenance of EI & Fans):Operation, Routine and preventive Maintenance and Upkeepment of all internal electrical and external installations such as light point, power point, circuit, sub & main distribution boards, switch boards, various electrical fittings, All type fans, Light, Gysers, cables/ Wires, thimbles, glands, compound/street lights internal & external cabling etc including recording and monitoring of the complaints on all days including sundays and holidays by providing following minimum staff as per details of staff (round the clock or in general shift as and when required as per direction of Engineer-in-Charge), terms and conditions and inventory attached including consumables materials such as PVC tape, screw etc but excluding E&M installations. Services of khallasi shall be used as per direction of Engineer-In-Charge.Location:- MCH Block LBS Hospital(a) Wireman - 3 Nos. (1 No. in Each Shift)(b) Khallasi - 3 Nos. (1 No. in Each Shift) |
| 201 | (Operation of DG Set and Sub-Stations)Round the clock Operation, Routine and preventive Maintenance and Upkeepment of 2 Nos. 750 KVA DG sets of Perkins make, 3 Nos. 1000 KVA Transformer of Kirloskar make including AMF panel, LT panel, capacitor panel etc installed at MCH Block LBS Hospital, New Delhi round the clock on all days of the week i/c Sundays and Holidays complete as per terms and conditions and details of minimum staff (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and inventory attached. Minimum requirement of manpower at MCH Block LBS Hospital(a) Wireman cum operator - 3 Nos. |
| 202 | (Operation of Passenger Lifts)Round the clock Operation, Routine and preventive Maintenance and Upkeepment of the 8 Nos. lifts Johnson Make and register the complaint regarding any fault in lift, to concern agency and to department without delay so that lift remains in working condition all the time. by providing following mimimum staff as per details of staff (round the clock or in general shift as and when required as per direction of Engineer-in-Charge), terms and conditions and inventory attached. on all days i/c Sundays and holidays. Services of khallasi shall be used as per direction of Engineer-In-Charge.Location :- MCH Block LBS Hospital(a) Lift Operator - 6 Nos. (b) Khallasi - 1 No. |
| 203 | (Operation of Fire Fighting, Wet Riser System, sprinkler, hydrant, portable fire extinguishers and Water Supply Pumps)Round the clock Operation, Routine and preventive Maintenance and Upkeepment of fire fighting system at LBS Hospital by deloying following staff for fire pump and all equipments, on all days i/c Sunday & holidays (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and as per terms & conditions and inventory attached etc complete as reqd.Location:- MCH Block LBS Hospital(a) Skilled (Fireman)-3 Nos. |
| 204 | (Operation of Fire Alarm System, PA System & Audio Video System)Round the clock Operation, Routine and preventive Maintenance and Upkeepment of fire alarm system, PA System & Audio Video System including panel and other accessories etc. installed at MCH Blocks at LBS Hospital, round the clock on all days of the week including Sundays and Holidays complete as per terms and conditions and details of minimum staff (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and inventory attached.Location:- MCH Block LBS Hospital (a) Skilled(Operator)- 3 Nos. |
| 205 | (Operation of HVAC)Operation of (300 TR - 3 Nos.) central AC plant & 225 KW 2 Set Solar Hot Water Generator system on all days i/c Sunday & holidays (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and as per terms & conditions and inventory attached etc complete as required. (As per enclosed terms & conditions) Services of khallasi shall be used as per direction of Engineer-In-Charge.Location:- MCH Block LBS Hospital(a) AC Mechanic cum technician - 3 Nos. (b) Unskilled (Khallasi)- 1 No. |
| 206 | (Operation of 300 KLD STP/ETP Plant)Operation of 300 KLD MBBR Technology base STP & 65 KLD ETP plant on all days i/c Sunday & holidays (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and as per terms & conditions and inventory attached etc complete as required with providing following minimum staff. Services of khallasi shall be used as per direction of Engineer-In-Charge.Location:- MCH Block, LBS Hospital(a) Skilled (Operator )- 3 Nos.(b) Unskilled (Khallasi)-1 No. |
| 207 | (Operation of LAN System, data telephone, Access Control System and Nurse Call System)Maintenance of LAN, data telephone, Access Control System and Nurse Call System on all days i/c Sunday & holidays (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and as per terms & conditions and inventory attached etc complete as required with providing following minimum staff.Location:- MCH Block, LBS Hospital (a) Skilled (Operator )- 3 Nos. |
| 208 | (Operation of CCTV)Operation of CCTV system complete with cameras NVR, SMPS, LED Monitor, Network switches and associated cable on all days i/c Sunday & holidays (round the clock or in general shift as and when required as per direction of Engineer-in-Charge) and as per terms & conditions and inventory attached etc complete as required with providing following minimum staff.Location:- MCH Block, LBS Hospital (a) Skilled (Operator)-3 Nos. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail