Tender For Repair/Replacement Of Roof Treatment, Chajjas, Parapet Wall, Tank Cleaning And Repairs Of Roof Sheets, Periodical Services Etc To Certain Bidgs In Domestic/Technical Area At Af Stn Narela Under Ge (Af) Gurgaon

Issued by Statutory Bodies & Commissions/Committees · Gurgaon, Haryana
Tender Value
46 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
10 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Roof Treatment, Chajjas, Parapet Wall, Tank Cleaning And Repairs Of Roof Sheets, Periodical Services Etc To Certain Bidgs In Domestic/Technical Area At Af Stn Narela Under Ge (Af) Gurgaon

BOQ

Name of Work:- Repair/Replacement of roof treatment, chajjas, Parapet wall, tank cleaning and repairs of roof sheets, Periodical services etc to certain bidgs in Domestic/Technical area at AF Stn Narela under GE (AF) Gurgaon
Sl. No. Item Description
1Demolition of roof treatment, any thickness including APP, roof tiles, screed bed or plastring and remove the rubish materials outside MOD land at a dumping place marked by any state govt/municipalities etc any distance complete all as specified and directed.
2M&L providing, cement concrete (1:2:4) type B-0 (Using 12.50mm graded stone aggregate) as in roof padding, sub base of floor coping or roof kerbs on roof chamfered on edge rounded or chamfered on edges including trowelling slightly complete all as specified & as directed.
3M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth (without using extra cement) after cleaning of roof surfaces with wire brushes complete all as specified.Notes : WPC shall be measured and paid seperately.
4Supply only intergral water proofing compound ISI Marked complete all as specified.
5Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces
6M&L for water proofing treatment with minimum 3mm thick APP (Atactic Polypropylene) modified polymeric prefabricated five layer membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer laid using buten torch and sealing all joints of APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm and 150 mm respectively as per manufacturer's instructions including aluminium paint on top surface complete all as specified.
7M&L for Cement concrete tiles 25cm x 25cm x 22 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments over 15mm thick cement screed bed in cement mortar 1:4 complete all as specified and directed.
8Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition ) of any description in any position not specifically provided complete complete all as specified.
9M&L for providing reinforced cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in slab/chajjas and the like complete all as specified.
10M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified.
11Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified.
12Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 5 cm but n exc 10 cm wide rough finished complete all as specified.
13M&L for guniting work to RCC work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and S&F welded wire mesh fabric or wire net less than 95 X 95X 3 mm adhesive, plaster grade for concrete admixture 1 part of cement and 3.5 part of sand and average thickness 40 mm and making the surface even including 15mm thick plastering in cement mortar (1:4) on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement plumb and making surface true to geometry in line and including necessary form work to be carried at upto double storey building Note.- Where ever reinforcement required will be measured and paid seperatly etc complete all as specified.
14Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified.
15M&L for brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified.
16M&L for half brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:4 etc complete all as specified.
17M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
18Dismantling wrought iron or mild steel work of any description not otherwise provided.
19S&F rolled mild steel in framed work as in doors or steel gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified.
20S&F 1.60 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required.
21S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified.
22M&L for cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified.
23M&L for prepration of new Steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified
24Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & directed.
25S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws as specified & directed.
26Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified.
27M&L for rendering 15 mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified.
28M&L rendering 10mm thick in cement mortar (1:3) as in ceilings finished even and smooth (without using extra cement) complete all as specified.
29M&L for 15 mm thick plastering in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement) complete all as specified.
30M&L for preparation of newly plastered or unplastered/ undecorated surface of wall and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre over a coat of primer, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified.
31M&L for preparation of newly plastered or unplastered/ undecorated surface of ceiling and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified.
32M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified
33M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over a coat of primer premium quality complete all as specified
34M&L for preparation of plastered or unplastered old decorated surface of wall by complete removal of existing treatment by mechanised sander of berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre over a coat of primer, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator.
35All as per item No.34 here-in-before but on surfaces of ceiling.
36M&L for preparation of plastered or unplastered/ undecorated old decorated surface of wall/ceiling and applying two or more coat premium acrylic emulsion paint of interior grade having VOC content less than 50 gms/litre over a coat of primer, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and directed.
37M&L for preparation of old surfaces of walls including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc.; rubbing down and stopping of surfaces using sand paper and applying one coat of oil bound distemper, complete all as specified and directed.
38All as per item No.37 here-in-before but on surfaces of ceiling.
39M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality on wall/ceiling surface including applying wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed.Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer.
40M&L for preparation of old treated plastered or unplastered surfaces of walls/ceiling including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of wheather proofing exterior acrylic emulsion paint on walls complete all as specified and as directed.
41M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling/roof sheet surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over priming coat premium quality on wall/ceiling surface including applying wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer.
42M&L for providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete all as specified.
43M&L for providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, on ceiling to prepare the surface even and smooth complete all as specified.
44M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth by cleaning, sand papering,brushing etc , filling in cavities and cracks etc with approved filler and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified .
45M&L for preparing old painted surfaces of steel and iron surfaces over 10 cm in width or girth by cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified .
46Site Clearance in soft and loose soil including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish outside the periphery of the area cleared.
47Disconnecting existing PVC water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified.
48Disconnecting existing PVC water tank of capacity exc.500 ltr but not exc. 1000 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified.
49Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified.
50Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 500 liters but not exceeding 1000 litres complete all as specified.
51S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
52S&F for rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
53Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
54Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
55Cutting chases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall etc complete all as specified.
56S&F medium grade galvanized steel tubing with all fittings & fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified.
57S&F tubes medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified.
58Refixing old steel tubing and connections 15mm dia in new or old position (walls, ceiling, floors etc) complete all as specified and directed.
59Refixing old steel tubing and connections 20mm dia in new or old position (walls, ceiling, floors etc) complete all as specified and directed.
60S&F in repair 20 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified.
61S&F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified.
62Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed.
63Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm and not exc 4 Sqm each complete all as specified.
64S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 \\"D\\" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed. Make : NCL type-4000 Series (Note : Glass and wiremesh shall be measured and paid separately under respective items)
65S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified.
66S&F sheet glass 4 mm thick ordinary quality and glazing with oil putty, wooden beads or fixed with neoprene rubber gasket in aluminium frame work complete all as specified.
67Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided complete including dismantling of floor tiles etc complete all as specified.
68M&L for 75 mm thick cement concrete type D-2 1:4:8 with )using 40 mm graded stone aggregates) as in sub base of flooring etc complete all as specified.
69M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified.
70M&L for 22-25 mm thick chequered designer coloured tiles (matt/glass finish), size, colour and shape as approved by GE, set and jointed in neat cement slurry and pointed with coloured cement to match etc complete all as specified as directed.
71M&L for cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in coping benching, gola, slightly rounded and similar items complete all as specified and as directed.
72Removing demolished materials / debries exc. 250 m but n exc. 500 m and depositing where directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56158316
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46 Lakhs
LAST DATE 15-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Roof Treatment, Chajjas, Parapet Wall, Tank Cleaning And Repairs Of Roof Sheets, Periodical Services Etc To Certain Bidgs In Domestic/Technical Area At Af Stn Narela Under Ge (Af) Gurgaon
Basic Detail
Tender No GE/GUR-/NIT-18/2026-27
Bidding Type Tender
Location
City Gurgaon
State Haryana
Key Dates
Publish Date 24 Jun 2026
Submission Date 15 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 46 Lakhs
Tender Fee 500
EMD 92000
Exemption Not Available
Document List
197e069d-efcf-4991-b66a-8131cb594a70.html
BOQ_867334.xls
TenderDocuments18.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

197e069d-efcf-4991-b66a-8131cb594a70.html

xls

BOQ_867334.xls

pdf

TenderDocuments18.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders