| 1 | Demolition of existing treatment of roof any type and preparing the surface by cleaning the concrete surface with wire brush and high pressure water jet and ensure that it is free of dust, oil, grease, loose particles vegetation roots etc.complete all as specified and directed by Engr-In-Charge. |
| 2 | Material and labour for Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) mixed with liquid water proofing compound and 1:30 slope to be maintained complete all as specified and directed by Engr-In-Charge. Note:- WPC shall be measured and paid seperately. |
| 3 | Supply only integral water proofing compound.(ISI Marked) complete all as specified and directed by Engr-In-Charge. |
| 4 | Material and labour for 10mm thick rendering in CM 1:4 with mixed with liquid water proofing compound on fair faces of brick work or on concrete surfaces complete all as specified and directed Engr-In-Charge. Note:- WPC shall be measured and paid seperately. |
| 5 | M&L for preparation of newly plastered/RCC surface making surface completely dry and applying primer till the surface is properly impreganted.water proofing treatment shall be provided with APP modified water proofing membrane 3 mm thick ( weighting not less than 3.00 Kg/Sqm on prepared suface after the primer has dried the membrane will be laid by torching to the surface as per manufacturer instruction and under strict supervisition .APP polymeric water proofing membrane shall consist of center core of 160 GSM Non Woven polyester mat protected on both side with a high quality polymeric asphaltic mix will be procted both side with thermo fusible HMHDPE film having the technical specification, laying procedure , overlap fusing methology and treatment around rain water pipe spout and tank stagging and similar location as per zonal specfication .After laying membrane apply a layer of blown biumen (conforming to IS 702) 85/25 grade @1.2 Kg/Sqm with blinding material such as sand in dry condition @ .5 to 1.00 Kg/Sqm shall be dusted over the bitumen complete all as specified and as directed . |
| 6 | M&L for Cement concrete 1:2:4 type B-1 ( 20 mm graded crushed stone aggregate) as coping ,roof padding, in roof kerb or mud stops ,water through and like including weathering,silghtly rounded or chamfered angle and throating with necessary formwork all as specified and directed. |
| 7 | M&L for plain cement concrete tiles 25cm x 25cm x22 mm thick with grey cement and no pigment machine pressed, set jointed and pointed in neat cement slurry in roofs , including 15 mm thick screed bed or bedding layer for laying tiles in C:M 1:4 complete all as specified and directed |
| 8 | M & L for dismantling floor, hearth, or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L non skid coloured ceramic tiles 7 to 8mm thick and area of each tile exceeding 0.11 sqm but not exceeding 0.16 sqm, as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including bedding layer of 20mm thick in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 10 | Demolition of lime/cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for cement concrete 1:5:10 type E2 using 40mm graded stone coarse aggregate in sunken floor complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for roughening the surfaces of old cement concrete floor by picking, cleaning and washing down with water to remove dust etc. rendering 10 mm thick in CM 1:3 mixed with including water proofing compound and applying two coat of polymer modified cementious water proofing coating as per manufacturers instruction over floor & vertival sides of sunken floors. |
| 13 | M&L for 75 mm thick PCC 1:3:6 type C2 ( using 20mm graded stone aggregates) as in sub base to floors, pavements etc complete all as specified and directed by Engr-in-Charge. |
| 14 | S & F in repair PVC valveless, syphonic action type, flushing cristern, low level, white, 10 ltr capacity with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engr-in-Charge. |
| 15 | M & L in repair vitreous china squatting pan Orissa pattern of size 580 x 440 mm white with back inlet and integral footrest and anti syphonnage pipe including 'P' or 'S' trap and provn of lime concrete ccomplete all as specified and directed by Engr-in-Charge. |
| 16 | M & L in repair vitreous china wash down water closet semi padestal pattern (Anglo-Indian type) white (excluding fixing bolts, flushing cistren and flush pipe) with 'P' or 'S' trap ccomplete all as specified and directed by Engr-in-Charge. |
| 17 | S & F Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminisied hinges devices complete all as specified and directed by Engr-in-Charge. |
| 18 | Taking down eaves gutters CI soil pipe/PVC rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed by Engr-in-Charge. |
| 19 | S&F 110 mm bore PVC (SWR) Pipes single socket in any length with rubber ring joints fixed to walls complete all as specified and directed by Engr-in-Charge. |
| 20 | S&F 110mm bore PVC (SWR) bends (any radius) complete all as specified and directed by Engr-in-Charge. |
| 21 | S&F 110mm bore PVC (SWR) branch piece single (single Y/T) equal or unequal complete all as specified and directed by Engr-in-Charge. |
| 22 | S&F 75 mm bore PVC (SWR) Pipes single socket in any length with rubber ring joints fixed to walls complete all as specified and directed by Engr-in-Charge. |
| 23 | S&F PVC (SWR) 75 mm bore junction single ''T' or 'Y' (equal or unequal) complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F 75mm bore PVC (SWR) bends (any radius) complete all as specified and directed by Engr-in-Charge. |
| 25 | S & F PVC (SWR) pipes 160mm bore single socketed in any length with rubber ring joints fixed to walls. |
| 26 | S & F PVC (SWR) bends 160mm bore any radius |
| 27 | M&L Plain aluminium sheeting 0.71 mm thick fixed as in crumple section. |
| 28 | Taking down cement plaster of any discription including racking out joints hacking for key scrubbing down with water etc |
| 29 | M&L for 20 mm thick plastering in two coats 15 mm thick backing coat in CM 1:6 and 5 mm thick setting coat in CM 1:4 mixed with water proofing compound @ 2% by weight of cement on fair faces of brick work or concrete wall surfaces finished even and smooth without using extra cement and using welded mesh where required all as specified including scaffolding, Safety net etc all complete as directed by Engr-in-Charge. (Note :- WPC and welded mesh shall be measured and paid separately) |
| 30 | M & L for Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives of required shade : New work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including preparation of surfaces complete all as directed. |
| 31 | Chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure in parapet walls and other concrete surfaces & cleaning and disposal of debris out side the premises etc. complete as directed by Engr-in-Charge. Hard concrete shopuld not be removed by force. |
| 32 | M&L for applying the rust remover alkaline in natrue having specific gravity of 1.1 kg/ltr to the existing/additional rebars including wire brushing manually or by mechanical tools, after cleaning the disturbed surface etc. complete by draining water. Rust remover shall be procured from one of manufacturer given below. (Make : Fosroc/ Sika/ BASF/ Krisha conchem/ Dr Fixit Pidilite) Note :- Measurement on the basis of area of concrete exposed. |
| 33 | M&L for applying two coats of anti-rust protective coating in the form of Acrylic Polymer with a minimum solid content to 40% solids mixed with cement in 1:1.5 proportion (1 part polymer and 1.5 parts cement) on rebars after cleaning of rust scales as per manufacturer's instruction. Anti-rust protective shall be procured from one of manufacturer given below. (Make : Fosroc/Sika/BASF/Krisha conchem/Dr Fixit Pidilite) Note :- Measurement on the basis of area of concrete exposed. |
| 34 | M/L for TMT bars 8mm dia. and over, Cut to length, bent to shape required including cranking, spirally and binding with MS wire (annealed) not less than 0.9mm dia.by placing in position new reinforcement bars including tack welding to existing reinforcement bars all complete as specified and as directed. |
| 35 | Providing bonding coat of SBR polymer over the exposed steel/welded mesh/concrete in ratio 1:1 to 1:1.5 of polymer and cement complete as directed by the consultant. SBR polymer to be procured from one of the manufacturer's given below. (Make : Fosroc/Sika/BASF/Krisha conchem/Dr Fixit Pidilite) . |
| 36 | M&L for repairing the damaged concrete portion by SBR Polymer with a minimum solid content to 40% cement mortar in proportion 1:5:15 i.e. (1 part SBR polymer : 5 parts OPC cement and and 15 parts of graded quartz aggregate (sand) upto 25mm thickness as directed by the manufacturer's instruction including necessary curing etc. complete all as specified & as directed. SBR polymer shall be procured from one of manufacturer given below. (Make : Fosroc/ Sika/ BASF/ Krisha conchem/ Dr Fixit Pidilite). |
| 37 | M&L for casting and repairing of excessively damaged members with micro concrete at all levels with all leads and lift as directed including providing and fixing of watertight shuttering of minimun 12 mm th. with supporting framework,all lead lift, mixing, placing, deshuttering, levelling the surface complete. Grade of Micro-concrete to be M-40 at 28 days and same shall be procured from one of manufacturer given below. (Make : Fosroc/Sika/BASF/Krisha conchem/Dr Fixit Pidilite). |
| 38 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over Old surfaces including prepration of old surface |
| 39 | Removing demolished material outside MD land all as specified and directed. (Note:- For item No 1 to 39 Work to be carried out at G+14 bldg including top roof,parapet and shaft walls with scaffolding & safety measures in repairs and in patches). Please Enable Macros to View BoQ information |