Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #56158266

Tender For Repair/Maint Of Lt Panels, Lt Switchgear With Connected Items At Various Places At Nda Khadakwasla

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
25 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
2 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Lt Panels, Lt Switchgear With Connected Items At Various Places At Nda Khadakwasla

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Jul-2026 CORRIGENDUM Date 20-Jul-2026
2 14-Jul-2026 CORRIGENDUM2 Date 05-Aug-2026
3 05-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-Aug-2026

BOQ

Name of Work:- REPAIR/MAINT OF LT PANELS, LT SWITCHGEAR WITH CONNECTED ITEMS AT VARIOUS PLACES AT NDA KHADAKWASLA
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in Hard/dense soil complete all as specified and as directed.
2Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed.
3Returning filling in incl spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and as directed.
4Material & labour cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and as directed.
5M&L for PCC (1:3:6) type C-1 (Using 20 mm graded mechanically crushed stone aggregate) as in stays and coping of poles including necessary form work complete all as specified and directed.
6S&F in repairs GI Strip 32mm x 6mm in any position , bending in shape and fixing in position with suitable size GI nuts, bolts & washers or by welding complete all as specified and as directed.
7S&F in repairs of aluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and as directed.
8S&F 1100 volts grade heavy duty flat cable of size 4sqmm 2 core , pvc insulated aluminum stranded conductor , served with inner sheathing of pvc tape and overall PVC sheathed in service connections suspended by insulating hangers not more then 1 mtr apart including replacing 4 mm suspension wire , complete all as specified and as directed.
9Ditto all as per item No.8 above but size 6 Sqmm 2 core
10Ditto all as per item No.8 above but size10 Sqmm 2 core
11Ditto all as per item No.8 above but size16 Sqmm 2 core
12M&L for painting of steel tubular LT poles 9 mtr including cross arms, clamps, back plates etc in situ on with one under coat and one finishing coat with aluminum paint after cleaning /preparation of surfaces including making white and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint and marking of pole No , Subsation No also complete all as specified and as directed.
13M&L for painting of steel tubular LT poles 11 mtr including cross arms, clamps, back plates etc in situ on with one under coat and one finishing coat with aluminum paint after cleaning /preparation of surfaces including making white and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint and marking of pole No , Subsation No also complete all as specified and as directed.
14M&L for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. RCC cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed.
15Ditto all as item No '14' above but using galvanized iron strip 32 x6 mm as earthing lead and GI protection pipe light grade 50 mm dia.NOTE for item no 32 & 33 :- The unit rate includes for protection pipe and GI earth wire 4.00mm /GI strip from top of earth plate up to 7.5 meter above ground level.NOTE for item no 31 & 32 :- The unit rate includes for protection pipe and GI earth wire 4.00mm /GI strip from top of earth plate up to 7.5 meter above ground level.
16Taking up UG cable of size 10 sqmm 2/4 core to 35sqmm 3.5core from trenches including bricks as required complete all specified and as directed.
17Taking up UG cable of size 50 sqmm 3.5 core to 95 sqmm 3.5core from trenches including bricks as required complete all specified and as directed.
18Taking up UG cable of size 120 sqmm 3.5 core to 185 sqmm 3.5core from trenches including bricks as required complete all specified and as directed.
19Supply and laying XLPE Insulated armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core complete all as specified and as directed.
20Ditto all as per Sch 'A' item No. 19 above but size 16 sqmm 2 Core
21Ditto all as per Sch 'A' item No. 19 above but size 16 sqmm 4 Core
22Ditto all as per Sch 'A' item No. 19 above but size 25 sqmm 4Core
23Ditto all as per Sch 'A' item No. 19 above but size 35 sqmm 3.5 Core
24Ditto all as per Sch 'A' item No. 19 above but size 50 sqmm 3.5 Core
25Ditto all as per Sch 'A' item No. 19 above but size 70 sqmm 3.5 Core
26Ditto all as per Sch 'A' item No. 19 above but size 95 sqmm 3.5 Core
27Ditto all as per Sch 'A' item No. 19 above but size 120 sqmm 3.5 Core
28Ditto all as per Sch 'A' item No. 19 above but size 150 sqmm 3.5 Core
29Ditto all as per Sch 'A' item No. 19 above but size 185 sqmm 3.5 Core
30Supply and laying 40 x 32 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 06 to 16 Sqmm 3.5 core complete all as specified and directed
31Supply and laying 50 x 38 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 25 to 35 sqmm 3.5 core complete all as specified and directed
32Supply and laying 63 x 50 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 50 Sqmm 3.5 core complete all as specified and directed
33Supply and laying 77 x 63 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 70 Sqmm 3.5 core complete all as specified and directed
34Supply and laying 90 x 75 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 95 Sqmm 3.5 core complete all as specified and directed
35Supply and laying 110 x 95 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 120 to 150 Sqmm 3.5 core complete all as specified and directed
36Supply and laying 120 x 103 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 185 to 240 Sqmm 3.5 core complete all as specified and directed
37S&F in replacement of GI Pipe , light grade 40 mm bore , confirming to IS-1239, for cable protection on poles/ walls/ Road crossing/ floor crossing complete all as specified and as directed.
38Ditto all as per item No.37 above but 50mm bore
39Ditto all as per item No. 37 above but size 80mm bore
40Ditto all as per item No. 37 above but size 100mm bore
41S&F Elect Shock Treatment Chart in Hindi , English and regional language laminated type of size 60 x 32 Cm (Approx) to be displayed in installations complete all as specified and as directed.
42M&L for MCCB TP, 50-63 Amps,16 KA, 415 volts Ics= 100% Icu,Adjustable over load setting 0.8-1.0 x In and Adjustable short circuit setting 6-10x In with spreader links and separators Confirming to IS/IEC 60947-2 complete all as specified and as directed..(make: Legrand/L&T/schenieder/siemens)
43Ditto all as per sl item No-42 above but, rating MCCB TP, 63-80 Amps,16 KA, 415 volts
44Ditto all as per sl item No-42 above but, rating MCCB TP, 80-100Amps, 16 KA, 415 volts
45Ditto all as per sl item No-42 above but, rating MCCB TP, 100-125 Amps, 16 KA, 415 volts
46Ditto all as per sl item No-42 above but, rating MCCB TP,125-160Amps ,16 KA, 415 volts
47Ditto all as per sl item No-42 above but, rating MCCB TP,160-200 Amps ,36 KA, 415 volts
48Ditto all as per sl item No-42 above but, rating MCCBTP,200-250 Amps ,36 KA, 415 volts
49Ditto all as per sl item No-42 above but, rating MCCB TP,320-400 Amps ,36 KA, 415 volts
50M&L for straight through (Heat shrinkable) suitable for LT UG cable 1.1 KV including cable connection on pole complete of size 16 to 35 Sqmm 3 1/2 Core complete all as specified and as directed.
51Ditto all as per sl item No-50 above but 50 to 95 Sqmm 3 1/2 Core
52Ditto all as per sl item No-50 above but 120 to 185 Sqmm 3 1/2 Core
53M&L for laying of Reinforced concrete pipes,class NP2 with one collar per lengh of pipe of dia 150 mm ,levelling with soft soil complete all as specified and as directed.
54Taking down LT panel/feeder pillar boxes from foundation complete all as specified and directed
55Repair/maintenance of APFC Panel board upto 150 KVAR capacity with replacement of unserviceable spare part/components modification of control wiring as required including flexible copper wire lugs complete all as specified and as directed. (Note: New spares required shall be measured and paid separately under respective items as supply only.)
56Supply only APFC Relays fourteen stage, 240 Volts complete all as specified and as directed.Make: L&T, Cat No-ETA or equivalent make of TATA Livert/Crompton Greaves/Siemens/Havells
57Supply only moulded CT 100/5 VA class-I rectangular shape complete all as specified and as directed.
58Supply only moulded CT 125/5 VA class-I rectangular shape complete all as specified and as directed.Make: Areva/Kappa/Pragati
59Supply only moulded CT 150/5 VA class-I rectangular shape complete all as specified and as directed.Make: Areva/Kappa/Pragati
60Supply only moulded CT 200/5 VA class-I rectangular shape complete all as specified and as directed.Make: Areva/Kappa/Pragati
61Supply only LED phase indicators red, yellow and blue 240 V AC complete all as specified and as directed.
62Supply only capacitor operation indicators LED type red and green 240 V AC complete all as specified and as directed.
63Supply only capacitor duty contactors-Type MO C 3 KVAR rating @ 440V,3Phase,50Hz complete all as specified and as directed.
64Supply only capacitor duty contactors-Type MO C 5 KVAR rating @ 440V,3Phase,50Hz complete all as specified and as directed.
65Supply only capacitor duty contactors-Type MO C 10 KVAR rating @ 440V,3Phase,50Hz complete all as specified and as directed.
66Supply only capacitor duty contactors-Type MO C 15 KVAR rating @ 440V,3Phase,50Hz complete all as specified and as directed.
67Supply only capacitor duty contactors-Type MO C 20 KVAR rating @ 440V,3Phase,50Hz complete all as specified and as directed.
68Supply only Fuse holders and fuse bases suitable for cylindrical / DIN fuse links of rated current 32A complete all as specified and as directed.
69Supply only cylinderical/DIN type HRC fuse 2A to 32 A all as specified and directed complete all as specified and as directed.
70Supply only Fuse holders and fuse bases suitable for cylindrical / DIN fuse links of rated current 63 A complete all as specified and as directed.
71Supply only cylindrical/DIN type HRC fuse 63 A all as specified and directed complete all as specified and as directed.
72Supplyonlycapacitor 2 KVAR,MPP heavy duty, cylindrical type 440 volts, 3 phase ,50Hz, gas filled complete all as specified and as directed.
73Supply only capacitor 3 KVAR,MPP heavy duty, cylindrical type 440 volts, 3 phase ,50Hz ,gas filled complete all as specified and as directed.
74Supply only capacitor 5 KVAR,MPP heavy duty, cylindrical type 440 volts, 3 phase ,50Hz, gas filled complete all as specified and as directed.
75Supply only capacitor 10 KVAR,MPP heavy duty, cylindrical type 440 volts, 3 phase ,50Hz ,gas filled complete all as specified and as directed.
76Supply only capacitor 15 KVAR,MPP heavy duty cylindrical type 440 volt ,3 phase ,50Hz, gas filled complete all as specified and as directed.
77Supply only capacitor 20 KVAR ,MPP heavy duty cylindrical type 440 volt ,3 phase,50Hz,gas filled complete all as specified and as directed.
78M&L for outdoor type street light timer box made out of CRCA sheet 3mm thick,ip65 ,double door with aprons,dust,vermin,weather proof with two coats of epoxy paint on one coat of red oxide primer comprising of phase indicator lamps=03 nos, Insulated aluminium busbar 100A =04 nos, cable entry provisions for one incoming and two outgoing cables , Incoming MCCB100A,four pole,415V=01 no complete with spreader terminals ,Astronomical timer,contactor 32A=02 nos,MCBDP40A =03 nos mounted on DIN channel, selector switch for Auto/mannual & OFF function incl internal wiring with 6sqmm multistranded copper conductor. The panel shall be self supported on angle iron frame made out of 4omm x 6mm angle iron 30cm on ground and 60 cm above surface complete all as specified and as directed.
79M&L for disconnecting, taking out under ground LT cable of length not more than 3 m and of size 10 sqmm to 25 sqmm including excavation, taking out bricks and relaying the old cable in loop and making connection with proper new thimbles in cut out boxes,Feeder pillar boxes, MCBs ,junction boxes etc including refilling of sand, relaying old bricks,DWC pipe and returning, filling in soil complete all as specified and as directed.
80Ditto all as per item No. 79 above but 35 sqmm to 50 Sqmm
81Ditto all as per item No. 79 above but 70 sqmm to95 Sqmm
82Ditto all as per item No. 79 above but 120 sqmm to185 Sqmm
83S&F Spreader terminals suitable for end connections of MCCB 3Pole upto 100A (set of 6)complete all as specified and as directed.
84S&F Spreader terminals suitable for MCCB 4 Pole upto 300A (set of 8 ) complete all as specified and as directed.
85S&F panel ventilating fan 100mmx100mm square type 220V AC 50 Hz 0.1A and with limit switch synchronised with panel door complete all as specified and as directed.
86S&F for replacement of analog street light timer switch for mannual switching ON/automatic/OFF daily with clock precision +/-5min complete all as specified and as directed.
87S&F power contactors 4 pole 40A,Model: MNX 40-2P ,complete with suitable NO/NC auxillary contact blocks complete all as specified and as directed.
88Repairs to existing LT air circuit breaker 3/4 Pole , 1200 to 2000A incl overhauling and replacement of spare parts complete all as specified and as directed. . Note : Spare parts will be paid and measured separately'
89Supply only Pole assembly complete all as specified and as directed.
90Supply onlypole connector complete all as specified and as directed.
91Supply onlyCT's for display Jaw Contact Assembly complete all as specified and as directed.
92Supply onlyVertical Terminals complete all as specified and as directed.
93Supply onlyArc Chutes complete all as specified and as directed.
94Supply onlyArc Chute fixing kit complete all as specified and as directed.
95Supply onlyShutter Assembly complete all as specified and as directed.
96Supply onlyCradle terminal assembly complete all as specified and as directed.
97Supply onlyCradle terminal support complete all as specified and as directed.
98Supply onlyMechanical operation counter complete all as specified and as directed.
99Supply onlyShunt release complete all as specified and as directed.
100Supply onlyUnder Voltage release 24 VDc/240VAC/415V complete all as specified and as directed.
101Supply onlyClosing Coil complete all as specified and as directed.
102Supply onlyResistor Kit complete all as specified and as directed.
103Supply onlyClosing preventor 240V/415V complete all as specified and as directed.
104Supply onlyMain Spring complete all as specified and as directed.
105Supply onlyMotor 110V/240V AC/DC complete all as specified and as directed.
106Supply onlyMotor limit switch complete all as specified and as directed.
107Supply onlyFront facia complete all as specified and as directed.
108Supply onlyCradle facia complete all as specified and as directed.
109Supply onlyLockable Trip push button type AA/BB/CC/DD complete all as specified and as directed.
110Supply only Locking in isolated posn Type A/B/C/D complete all as specified and as directed.
111Supply onlylocking in any position complete all as specified and as directed.
112Supply onlyRacking interlock complete all as specified and as directed.
113Supply onlyDoor interlock complete all as specified and as directed.
114Supply onlyRoller Assembly complete all as specified and as directed.
115Supply only Spring Kit complete all as specified and as directed.
116Supply only Hardware Kit complete all as specified and as directed.
117Supply only Push button Red/Green complete all as specified and as directed.
118Supply only Racking Handle complete all as specified and as directed.
119Supply only Operating Handle complete all as specified and as directed.
120Supply only Micro switch for common indication for spring charge action complete all as specified and as directed.
121Supply only Micro switch for common indication for service position complete all as specified and as directed.
122Supply only Micro switch for common indication for overload, Short circuit complete all as specified and as directed.
123Supply only Telescopic rail left /right complete all as specified and as directed.
124Supply only Trip rod assembly complete all as specified and as directed.
125Supply only Trip Latch complete all as specified and as directed.
126Supply only Main Shaft assembly complete all as specified and as directed.
127Supply only Hylam Partition complete all as specified and as directed.
128Supply only Jaw contact assembly complete all as specified and as directed.
129Supply, installing, testing and commissioning factory made and tested ) including CPRI type test certified) LT feeder pillar box (KIOSK) out door type mounted on angle iron frame of size 40mmx6mm, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bars of rating 300 amps rating installed on porcelain insulator. The panel shall be dust and vermin proofwith gable roof . IP-65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type, with apron for cable entry with double door setter and locking arrangement (including provn of 65mm Godrej lock with two keys) internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 Sqmm) complete all as specified and as directed and comprising of the following :-(a) Incoming :-(i) MCCB 4 pole 25 KA, 250 Amps capacity 415 V, 50 Hz, , AC supply, IS marked, complete with all standard accessories - 01 Nos.(ii) Insulated copper busbar 300A=04 nos mounted on epoxy insulators & housed in compattmentalised chamber.(b) Outgoing(i) MCCB 3 pole 25 KA, 100-125 Amps capacity- 01 Nos(ii) MCCB 3 pole 32-50 Amps 25 KA, 415V - 07 Nos (iii) Digital Amps meter 0 to 150 Amps with selector switch - 01 No(iv) Digital Volt meter 0 to 500 volt with selector switch - 01 No(v) Indicator lamp Red/Yellow/Blue - 03 Nos(vi) three CTs of ratio 400/5A class-1 burden 15VA- 01 Set(vii) MCBDP 40A,10KA=02 Nos mounted on DIN channel
130Supply, installing, testing and commissioning factory made and tested ) including CPRI type test certified) LT feeder pillar box (KIOSK) out door type mounted on angle iron frame of size 40mmx6mm, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bars of rating 100 amps rating installed on porcelain insulator. The panel shall be dust and vermin proofwith gable roof . IP-65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type, with apron for cable entry with double door setter and locking arrangement (including provn of 65mm Godrej lock with two keys) internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 Sqmm) complete all as specified and as directed and comprising of the following :-( (a) Incoming :-(i) MCCB 4 pole 25 KA, 100 Amps capacity 415 V, 50 Hz, , AC supply, IS marked, complete with all standard accessories - 01 Nos.(ii) Insulated copper busbar 100A=04 nos mounted on epoxy insulators & housed in compattmentalised chamber.(b) Outgoing(i) MCCB 3 pole 25 KA, 32-50 Amps capacity- 02 Nos(ii) Star delta starter suitable for 10 HP, 415V - 01 Nos (iv) Digital Amps meter 0 to 150 Amps with selector switch - 01 No.(v) Digital Volt meter 0 to 500 volt with selector switch - 01 No(vi) Indicator lamp Red/Yellow/Blue - 03 Nos(vii) three CTs of ratio 100/5A class-1 burden 15VA- 01 Set(viii) MCBDP 40A,10KA=02 Nos mounted on DIN channel
131M&L for replacement of panel hinges incl welding to panel door /angle iron support complete all as specified and as directed.
132Painting of LT Control panel.Feeder Pillar boxes and bus bar chamber with one coat of synthetic enamel paint after preparation complete all as specified and as directed. Note Colour of paint will be approved by Engineer in Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56158266
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 12-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Lt Panels, Lt Switchgear With Connected Items At Various Places At Nda Khadakwasla
Basic Detail
Tender No 8076/E8
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 05 Aug 2026
Submission Date 12 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
8076.pdf
BOQ_867351.xls
d3f98b25-1a3d-4ece-a143-f19201690bdf.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 05, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 12, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
pdf

8076.pdf

xls

BOQ_867351.xls

html

d3f98b25-1a3d-4ece-a143-f19201690bdf.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender