Tender For Special Repair To 04 Md Jcos Accn In Bldg No P-165 In Udham Vihar Of Jak Rif In Zone-Iii Area Under Ge(S) Jaipur At Mil Stn Jaipur
Tender Value
31.10 Lakhs
Estimated cost
Bid Submission
16 Jul 2026
11 days left
EMD
62200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To 04 Md Jcos Accn In Bldg No P-165 In Udham Vihar Of Jak Rif In Zone-Iii Area Under Ge(S) Jaipur At Mil Stn Jaipur
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed. |
| 3 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed |
| 4 | Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. |
| 5 | M&L for sand filling under floor or in foundations including gently punned as in cushioning to cable and for foundation in floor complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid. |
| 6 | M&L for drilling suitable holes in reinforced cement concrete with power driven drill machine to a minimum depth of 10D (D-dia of bar in mm) in RCC beams, lintels, columns and slabs to introduce new steel bars including cleaning the holes by air blowers prior to fixing the new steel bars in position using Lokfix E77, a two-component epoxy anchoring material, supplied in 3:1 ratio having compressive strength (EN196) not less than 122 N/sqmm, Flexural Strength (EN196) not less than 66 N/sqmm, E Modulus (EN ISO 527-2) 6300 N/sqmm or of equivalent make but excluding the cost of reinforcement, complete all as per direction of Engineer-in- Charge for 10mm dia shear connectors. Note : 1. Anchoring chemical shall comply with ETA 21/0354, ETA 21/0518 for anchoring bars for 10mm dia complete all as specified and directed.2. Reinforcement shall be measured and paid separately. |
| 7 | M&L for chipping of plaster / unsound weak and cracked concrete / cover of reinforcement of RCC member like slab, beam, column, chhaja etc or as per site requirement by standard power driven percussion type or pneumatic chisel including tapering all edges, making square shoulder of cavities etc and disposal of debris / malwa from site complete all as specified and directed. |
| 8 | M&L for cleaning of existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete and applying two coats of alkline rust converting primer on the existing rebar and allowing it to react with rust for 6 hours and form corrosion resistant, insoluable and adherant protective layer, including cleaning the reinforcement wire brushing to remove the rust spalls, with time interval of 1 hour between the coats complete all as specified and directed. |
| 9 | M&L for corrosion inhibiting impregnation coating, designed for use as an imregnation for protection of steel reinforcement within unexposed concrete with in consumption of 0.5 Kg/Sqm. The product should be amino alcohol and inorganic combination based migratroy corrosion inhibitor for both cathodic and anodic protection complete all as specified and directed.Make : Fosroc / Thermax / Sika or equivalent as approved by GE. |
| 10 | M&L for zinc rich epoxy anti-corrosive protective coating for rebar corrosion protection system complete all as specified and directed.Make : Fosroc / Thermax / Sika or equivalent as approved by GE. |
| 11 | M&L for providing, mixing & applying two component of epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacturer specification including prepartion of surface by chipping and throughly cleaning of surface complete wherever required complete all as specified and directed. Make : Fosroc / Thermax / Sika or equivalent as approved by GE. |
| 12 | M&L for re-building the section of damaged RCC elements to its original size on an average 15 mm thickness in two layers each by providing and applying with pre- batched, polymer modified mortar of approved make having compressive strength not less than 50 N/sqmm (28 days) as per ASTM C-109 and flexural strength not less than 05 N/sqmm (7 days) as per ASTM C-293-79 standards including water fog curing to keep surface moist for seven days complete all as specified and directed. Make : Fosroc / Thermax / Sika / Dr. fixed or equivalent make as approved by GE.Note : (i) To achieve the required thickness, the above process should be repeated after 24 hours.(ii) Surface area with 15mm thick layer will be measured as one unit for payment purpose.(iii) Rate shall be including all necessary scaffolding upto height of four storey building. |
| 13 | M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed. |
| 14 | M&L brick work using old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 15 | M&L for cutting holes in brick walls exc half brick but not exc one brick built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed.Note:- The depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall. |
| 16 | M&L providing edge moulding to Granite stone any description 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc complete all as specified & directed. |
| 17 | M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms or any horizontal portion and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed. |
| 18 | Taking down chowkats or frames n.exc 1.5 Sqm each with shutters (without taking off shutters from the frames) including making good of disturbed portion except space for holdfast complete all as specified and directed. |
| 19 | Taking down chowkats or frames exc. 1.5 sqm but n.exc 4.0 Sqm each with shutters (without taking off shutters from the frames) including making good of disturbed portion except space for holdfast complete all as specified and directed. |
| 20 | S&F second class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass , gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed. |
| 21 | S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 22 | Taking down shutters of any description exc. 1.00 Sqm but n.exc. 2.00 Sqm each complete all as specified and directed. |
| 23 | S&F Factory made Solid PVC Moulded door shutter with particle board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 24 | S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing. |
| 25 | M&L in repair for 18 mm thick WPC (Wood Polymer Composite) panel with suitable pins, screws and adhessive in cabinets body, shutters and shelves etc. complete all as specified and directed. |
| 26 | S&F 20 mm dia stainless steel, silver & chrome finish, fancy type, anti-rust curtain rod with curtain bracket , finials fixed by screw in wall complete as all specified and directed. |
| 27 | S&F aluminium, anodised, barrel tower bolts of extruded section 150 mm long complete all as specified and directed. |
| 28 | S&F butt hinges, medium weight, cold rolled mild steel 100 mm long complete all as specified and directed. |
| 29 | S&F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 30 | S&F aluminium handles cast type anodised of 125 mm size complete all as specified and directed. |
| 31 | M&L in repair for auto close hinges, stainless steel, bright finish or electrogalvanised fixed complete all as specified and as directed. |
| 32 | S&F mild steel framed work for windows grills such as grills, ladders, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors / window and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 33 | S&F mild steel flat iron as in bands straps, supports or stays for rainwater, ventilating pipes including bolt if required, hooks (stay) heavy for large gates,hook and pintle hinges,large hasps and staples, hold fasts, wall ties, hooks for hanging fans ,cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 34 | M&L for mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 35 | S&F pressed steel frames of size 105 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including one shop coat of priming complete all as specified and directed. |
| 36 | S&F pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including one shop coat of priming complete all as specified and directed. |
| 37 | M&L for powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 38 | S&F powder coated (thickness of powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, side hung / sliding type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21, 100 mm long (2 No) , suitable handle (1 No) complete all as specified and directed. |
| 39 | S&F aluminium expanded metal for securing wire mesh over gauzed shutter complete all as specified and directed. |
| 40 | M&L for preparation of roof surface by sweeping and removing all dust /dirt and cleaning with water etc and water proofing treatment to roof slab with APP modified polymeric membrane centre core 100 micron HMHDPE outer film 20 micron each having weight not less than 3 Kg/Sqm with 100 mm side over lap and 150 mm end lap laid as per manufacturer’s instructions with including following :- (a) Applying evenly a coat of bituminous primer conforming to IS-3384-1965 @ 0.30 Kg/Sqm on prepared surface till the surface is properly impregnated. (b) Second coat of bonding material using blown grade bitumen 85/25 confirming to IS-702 @ 1.20 Kg per Sqm. (c) Third course i.e. Laying of APP modified membrane described here-in-before with 100mm over lap in longitudinal direction and 100mm in transverse direction, all joints and changes in all directions should be curved with cement mortar (1:3) mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane. (d) Forth coat of bonding material using blown grade bitumen 85/25 confirming to IS-702 @ 1.20 Kg per Sqm. (e) Sprinkling of course sand dusting @ 1 Kg per sqm as directed. Note:- (i) The Membrane shall be extended and inserted into the groove of size 50 mm wide and 75 mm deep cut into the parapet wall and sealed with cement plaster in CM 1:3 mixed with WPC @ 3% by weight of cement. (ii) The cost of cutting groove and filling materials shall deemed to be included against quoted unit rate. |
| 41 | M&L for machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing on treads of step and landing of stair including screed bed 15 mm thick in CM 1:6 complete all as specified and directed. |
| 42 | M&L for 75 mm thick PCC 1:3:6 type C2 using 40 mm graded stone aggregate, in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. |
| 43 | M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub-floors, sub-bases, floors and paving, etc. complete all as specified and directed. |
| 44 | M&L for 40 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in flooring treatment surface finished even and smooth without using extra cement complete all as specified and directed. |
| 45 | M&L for glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm / 450X 300X 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including backing coat / rendering 15 mm thick in CM 1:4 complete all as specified and directed. |
| 46 | M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed 15 mm thick in CM 1:4 complete all as specified and directed. |
| 47 | M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 48 | M&L for non skid joint free ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and including rendering 10 mm thick in CM 1:4 complete all as specified and directed. |
| 49 | M&L for chequered cement concrete tiles 30 cm x 30 cm x 22 to 25 mm thick set, jointed and pointed in neat cement slurry as in floors with grey cement and pigments over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 50 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 51 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 52 | M&L for providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 53 | Dismantling of existing sunken treatment including plaster and M&L for water proofing treatment on existing sunken portion with the following specification :- (a) 40 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring. (b) 15 mm thick (average) plaster on sunken floor in CM (1:4) with and including water proofing compound as per manufacturer instruction complete all as specified & directed. (c) Apply bituminous primer @ 0.5 Kg / Sqm conforming to IS 3384 -1965 on prepared surface till the surface is properly impregnated. (d) Apply hot bitumen 85/25 grade @ 1.2 Kgs/Sqm confirming to IS 702-1988. (e) Laying polymeric water proofing membrane weight not less than 3.0 Kgs /Sqm as per manufacturer instructions confirming to relevant IS (Make:- STP Ltd / Pidilite / Tikitar). (f) Apply layer of blown grade bitumen 85/25 @ 1.2 Kgs/Sqm confirming to relevant IS. (g) One spout of 40 mm GI Pipe Shall be provided in Sunken floor and sunken portion shall be filled with lean concrete Type E-2 (1:5:10) using brick Coarse aggregate. |
| 54 | M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 55 | M&L for rendering 10 mm thick in CM 1:4 as in ceiling surface and finished even and smooth without using extra cement complete all as specified and directed. |
| 56 | M&L for rendering on stone masonry or other than fair faces of brick work of wall 15 mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed. |
| 57 | Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 58 | M&L for 20 mm thick screed bed or bedding layer in CM 1:4 surface finished fair and even for laying floor finishes complete all as specified and directed. |
| 59 | M&L for preparation of old surface of wall of any description and applying two coats of oil bound distemper (OBD) over and including 1 mm thick wall putty all as specified and directed. |
| 60 | M&L for preparation of new surface of wall of any description and applying two coats of oil bound distemper (OBD) over and including 1 mm thick wall putty all as specified and directed. |
| 61 | M&L for preparation of new surface of ceiling of any description and applying two coats of oil bound distemper (OBD) over and including 1 mm thick wall putty all as specified and directed. |
| 62 | M&L for preparation of old surface of ceiling of any description and applying two coats of oil bound distemper (OBD) including 1 mm thick wall putty all as specified and directed. |
| 63 | M&L for complete removal of existing treatment and preparation of old surface of wall of any description with a coat of 1 mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed.Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE.Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17 of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work. |
| 64 | M&L for preparation of new surface of walls of any description with a coat of 2mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed.Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE.Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17 of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work. |
| 65 | S&F figured glass 5 mm thick, pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed |
| 66 | M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 67 | M&L for preparation of old painted surfaces of steel of any description, over 10cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 68 | M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 69 | M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 70 | S&F in repair bib taps 2-in-1 cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fancy type of 15 mm bore dia of pipe complete all as specified and directed. |
| 71 | Dismantling of AC/PVC water tank and S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in position complete all as specified and directed |
| 72 | M&L for providing circular, raised platform of height 20 cm below the tank and base dia 25 cm more than the external dia of PVC tank of 500/1000 liters using PCC 1:3:6 type C1 using 20 mm graded stone aggregate with smooth finish including necessary form work etc. complete all as specified and directed. |
| 73 | M&L for Double Wall Corrugated (DWC) pipe of class SN-4, IS-16098 (part-II) of 150mm bore (internal), laid to slope in trenches, jointed complete with coupler, bends, Tee, reducers etc and tested complete all as specified and directed.Make : Ultra plus of Supreme / Corfit of Prince / D-Rex of Astral or equivalent as approved by GE. |
| 74 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed. |
| 75 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed. |
| 76 | M&L in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 75 mm bore of pipe etc complete all as specified and directed. |
| 77 | M&L in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 78 | S&F PVC (SWR) bends any radius of 75 mm bore without access door complete all as specified and directed. |
| 79 | S&F PVC (SWR) bends any radius of 110 mm bore without access door complete all as specified and directed. |
| 80 | S&F PVC (SWR) junction single,(Single T) equal or unequal of 75 mm bore of pipe complete all as specified and directed. |
| 81 | S&F PVC (SWR) junction single,(Single T) equal or unequal of 110 mm bore of pipe complete all as specified and directed. |
| 82 | M&L PVC (SWR) vent cowl 110 mm complete all as specified and directed. |
| 83 | M&L PVC (SWR) floor trap of diameter of outlet 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed |
| 84 | M&L PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed |
| 85 | M&L in repair for 100 mm dia PVC (SWR) Nahani trap with SS grating including jointing with solvent cement including fixing with cement concrete type B-1 (1:2:4, 20mm graded aggregate) complete all as specified and as directed. |
| 86 | Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed. |
| 87 | S&F 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors complete all as specified. |
| 88 | S&F bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15 mm bore dia of pipe complete all as specified and directed. |
| 89 | S&F in repair for 15mm bore dia of pipe pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 90 | S&F for 15mm bore dia of pipe brass CP, wash hand basin mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed. |
| 91 | S&F for 15mm bore dia of pipe brass CP kitchen mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed. |
| 92 | S&F for 15mm bore dia of pipe brass CP wall mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed. |
| 93 | S&F in repair stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe complete all as specified and directed. |
| 94 | S&F in repair stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions for 20 mm bore dia of pipe complete all as specified and directed. |
| 95 | S&F stop cock cast copper alloy, screwed down, high pressure with crutch or butterfly handle fancy type chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe complete all as specified and directed. |
| 96 | S&F ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 20 mm bore dia of pipe complete all as specified and directed. |
| 97 | S&F in repair waste fittings, brass, chromium plated 32mm dia for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 98 | S&F towel rail 600 mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 190 gms) complete all as specified and directed. |
| 99 | S&F PVC connection 15 mm size bore with PTMT nuts of length 450 mm complete all as specified and directed. |
| 100 | S&F in repair sink made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 101 | M&L in repair wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe also including plastic water closet seat, black/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, excluding flushing cistern and flush pipe complete all as specified and directed. |
| 102 | S&F in repair Water closet vitreous china squatting pan, orissa pattern 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) and including provision of lime concrete bedding ,'P' or 'S' trap 100 mm bore , flushing pipe ,anti-syphonage pipe and connection etc and making good to floor complete all as specified and directed. |
| 103 | S&F in repair PVC 10 litres capacity valveless ,syphonic action type low level flushing cistern ,white including flush pipe, inlet, ball valve, float and handle etc complete all as specified and directed. |
| 104 | S&F in repair brass chromium plated shower rose 125 mm size with or without swivel joint complete all as specified and directed. |
| 105 | M&L in repair for vitreous china wash basin, white,flat back, size 550 x 400 mm with brackets, including PVC connection of 450 mm long, PVC (HDPE) 32 mm bore waste pipe, brass couplings 32 mm CP etc. complete all as specified and directed. |
| 106 | S&F kitchen plate rack of size 900 mm x 900 mm x 250 mm made out of 1 mm thick stainless steel sheet with shelf and dividing steel bars shelf fixed on wall with rawl plug and screws etc complete all as sapecified and directed. |
| 107 | S&F in repair PTMT alloy bathroom cabinet with mirror of size 450 x 600 mm fixed with and including chromium plated brass screws and wooden / plastic cleats complete all as specified and directed. Make : Nilkamal / Pearl / Prayag etc. |
| 108 | S&F float corner glass shelve 8 mm thick 300 mm radius complete all as specified and directed. |
| 109 | S&F in repair for Bathroom Duct Pipelines for Waste Water Pipe, Domestic Water Pipes and Riser supply down take pipes fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt R/M System - 1. Waste Water Pipe 2 1/2\\" PVC, 2. Water Supply Down take lines 3/4\\" GI - 2 nos. and 3. Riser Supply Down take pipelines 3/4\\" GI - 1 nos. running from Terrace to Ground Floor Vertical Fixed line with wall distance 4\\": Pipe Support Clamping made of 1. Profile Bracket Type A2 (Wall Distance 4\\") made of Low Carbon Hot Roll gauge corrected Oil Pickled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanized + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted \\"C\\" Channel B3 Type to be used of size 20\\" (Continuous Slotted \\"C\\" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanized + Zn Al Flake coated of material 48 x 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hot dip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade :- IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.:- 1. Profile Bracket of A2 Type (Wall distance 4\\") - 2 Nos. 2. Continuous Slotted C Channel of B3 Type Size 20\\" - 1 No.; 3. U Bolt R/M for 2 1/2\\" PVC Pipe Dia. - 1 No.; 3/4\\" GI pipe Dia. - 3 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing. (Refer CE Jaipur Zone Technical Drawing no. TD/2022/01.) Make :- Shaivi or equivalent as approved by GE. |
| 110 | S&F repair of Toilet Duct Pipelines for Soil Water Down take pipe fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt System - 1. Soil Water Pipe 4\\" PVC - 2 pipe and running from Terrace to Ground Floor Vertical Fixed line with wall distance 3\\": Pipe Support Clamping made of 1. Profile Bracket Type A2 (Wall Distance 3\\") made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted \\"C\\" Channel B3 Type to be used of size 22\\" (Continuous Slotted \\"C\\" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. |
| 111 | S&F in repair CP Stainless Steel Wall Mounted Square Soap Dish / Soap Stand / Soap Holder, approximate size 160x 160mm fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 112 | S&F in repair chromium plated towel ring round (20cm dia) / square (20cm x20cm) shape (minimum weight 300gm) with round flange complete all as specified and directed. |
| 113 | Fixing only exhaust fan after minor repair like oiling, greasing etc and connecting up including provision of cable from ceiling rose / connector to fan and including painting with one coat of synthetic enamel paint complete all as specified and directed.Note:- Old exhaust fan obtain from taking down shall be refixed. |
| 114 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. Please Enable Macros to View BoQ information |
| 115 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender