Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #56158234

Tender For Maintenance And Repairs Summer Appliances And Other Connected Items Under Age E/M-I Of Ge (North) Meerut Cantt

Issued by Statutory Bodies & Commissions/Committees · Meerut, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Jul 2026
10 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Meerut → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Maintenance And Repairs Summer Appliances And Other Connected Items Under Age E/M-I Of Ge (North) Meerut Cantt

BOQ

Name of Work:- MAINT AND REPAIRS SUMMER APPLIANCES AND OTHER CONNECTED ITEMS UNDER AGE E/M-I OF GE (NORTH) MEERUT CANTT
Sl. No. Item Description
1M&L for servicing, repair and replacement of unserviceable parts at E/M yard including opening of fan body of any type make & model cleaning, separating serviceable parts for reuse / refix same after repairing and replacing defecive parts witth new one of certain minor spares and consumables like MS screws, 2 way connector, rubber/ reel, insulator,condenser holder, ms nuts bolts, washers, grease is deemed to be included in the quoated rate ) reassembling, greasing complete all as specified and directed for the following:- Note:- Major spare parts required to make functional the equipments shall be measure & paid seprately under relevent items as S & F in repairs.
2Ceiling Fan 1200mm Sweep of any make or model
3Ceiling Fan 1400mm Sweep of any make or model
4Wall / Cabin Fan 400 / 450mm Sweep of any make or model
5Exhaust Fan 450mm Sweep of any make or model
6Pedestal Fan 400 / 450mm Sweep of any make or model
7Air Circulator Fan Heavy duty 450/600mm Sweep of any make or model
8M & L for rewinding the fans of any make, any model, from a reputed workshop, removing the burnt winding, cleaning slots, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc with replacement of ball bearing, GM bush, body screws, testing and commissioning on full load for 4 hrs continuous running all as directed for the following:-
9Ceiling Fan 1200mm Sweep of any make or model
10Ceiling Fan 1400mm Sweep of any make or model
11Wall / Cabin Fan 400 / 450mm Sweep of any make or model
12Exhaust Fan 450mm Sweep of any make or model
13Pedestal Fan 400 / 450mm Sweep of any make or model
14Air Circulator Fan Heavy duty 600mm Sweep of any make or model
15M & L for Preparing the surface, remove the existing painting by scraping, cleaning, filling the cavities and applying 2 coats of spray paint of synthetic enamel white / Brown paint , including writing the MES Nos. all as directed for the following:-
16Ceiling Fan 1200mm Sweep of any make or model
17Ceiling Fan 1400mm Sweep of any make or model
18Exhaust Fan 450mm Sweep of any make or model
19Air Circulator Fan 600mm Sweep of any make or model
20S & F, Condensor / Capacitor, 240V, AC, suitable for fans all as directed in make TiBCON, HAVELLS, EPCOS for the following:-
212.5 mfd complete all as specified and directed
223.15 mfd complete all as specified and directed
234.0 mfd complete all as specified and directed
24S & F, Down rod, suitably threaded and holed, made out of 15mmdia GI tubes, duly painted, 300mm long, suitable for ceiling fans any type, any make, any size complete all as specified and directed
25All as described Ser item No. 24 here-in-before but 600mm long
26All as described Ser item No. 24 here-in-before but 900mm long
27S & F in repairs 1100V grade PVC sheathed PVC insulated flexible 2 core cable with multistranded copper conductor of size 1.5Sqmm, complete all as specified and directed
28S & F in repairs, Wall fan, 450mm sweep, AC,230V incl T/D Unserviveable one and depositing to MES store complete all as specified and directed.
29S & F in reapirs, PVC fresh air fan, 250mm sweep with louvers, AC, 230V incl T/D Unserviveable one and depositing to MES complete all as specified and directed.
30All as described Ser item No. 29 here-in-before but 200mm sweep
31S & F in reapirs Exhaust fan metal body 450mm with louvers, AC, 230V and depositing to MES store yard complete all as specified and directed.
32All as described Ser item No. 31 here-in-before but 300mm sweep
33S & F in repairs, Industrial type Wall mountedf Air Circulator fan, 450mm sweep, AC,230V and depositing to MES store yard complete all as specified and directed.
34All as described Ser item No. 33 here-in-before but 600mm sweep
35S & F in repairs BLDC Ceiling Fan 1200mm Sweep with remote control, 5 star BEE rating Energy saving and depositing to MES store yard complete all as specified and directed.
36All as described Ser item No. 35 here-in-before but 1400mm sweep
37S & F in repairs of new compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection making all existing connection including testing for 1.5 ton Window /Split type Air conditioners complete all as specified and directed
38All as described Ser item No. 37 here-in-before but of capacity 2 ton.
39All as described Ser item No. 37 here-in-before but Invertor type 1.5 Ton.
40M&L for filing and checking Gas refrigerant R12/R22/R410A/R134a in the sealed system of window/Split type AC 1.5/2 Ton capacity after checking leakage / pressure vacumising flushing the sealed unit including replacement of filter drier and capillary tube complete all as specified and directed
41Taking down of window/Split AC 1.5/2.0 any type/any model ton capacity and cleaning / servicing of AC, overhauling of blower motor , preparation of body for painting one coat of black paint inner side and one coat synthatic enameled paint on the outer cover of AC and marking of SM/MES No and testing of full load of summer season and reinstallation at site complete all as specified and directed.Note : Worn out parts shall be measured & paid seperately under relevant item as S & F in repairs.
42S&F in repairs Split AC of capacity 1.5 / 2 TR Blower motor 1/6 HP with base / rubber bush complete Suitable for any make / model complete all as specified and directed
43All as described Ser item No. 42 here-in-before but Condensor fan motor Suitable for Split AC/ Window AC double ended of capacity 1.5 / 2 Ton AC complete all as specified and directed
44All as described Ser item No. 42 here-in-before but Condensor fan blade metallic.
45All as described Ser item No. 42 here-in-before but Drum type blower fan PVC as per existing.
46All as described Ser item No. 42 here-in-before but Running capacitor 36 mfd.
47All as described Ser item No. 42 here-in-before but Starting capacitor 100 to 120 mfd
48All as described Ser item No. 42 here-in-before but Selector switch. Any make / any model
49All as described Ser item No. 42 here-in-before but Thermostate
50All as described Ser item No. 42 here-in-before but with plastic / juite Air filter.
51All as described Ser item No. 42 here-in-before but cooling coil assembly suitable for any make / any model as per site requirement
52All as described Ser item No. 42 here-in-before but Condensor coil assembly.
53All as described Ser item No. 42 here-in-before but Wiring kit complete.
54All as described Ser item No. 42 here-in-before but Capacitor 6 mfd.
55All as described Ser item No. 42 here-in-before but Blower motor 1/3 HP for indoor unit split type AC suitable for any Make / any model as per site requirement.
56All as described Ser item No. 42 here-in-before but Running capacitor 45 mfd.
57All as described Ser item No. 42 here-in-before but Blower fan 3 Ft long suitable for split AC (as per existing) complete all as specified and directed
58S & F in repairs of electronic circuit plate (PCB) with remote control including necessary repairs to electronic circuit operation suitable for 1.5 / 2.0 ton split/window type AC complete all as specified and directed
59S & F in repairs Air break contactor relay 6.2 Amps, 415 Volts AC suitable for split type AC complete all as specified and directed
60Labour for shifting of split AC 1.5 , 2 ton capacity one place to another places as required at site and disconnecting of copper tubing, PVC pipe connection and installation of New location indoor/outdoor unit complete with Gas charging tested on full load on summer season complete all as specified and directed.
61S & F in repairs indoor unit of capacity 2 ton with cooling coil, blower motor complete with all accessories complete all as specified and directed.
62S & F in repairs outdoor unit of capacity 2 ton with condensor coil, blower motor 1/6 HP , single phase, including fixing in old serviceable compressor and connection of copper tubing suction / discharge complete all as specified and directed.
63S & F in repairs of new compressor hermetically sealed type type compressor suitable for 300 to 320 ltrs capacity refrigerator with suitable rated capacity electric motor and shall be equipped with relay / over load protection 230 Volt, 50 Hz, including testing for any make or model complete all as specified and directed.
64All as described Ser item No. 63 here-in-before but 165 ltrs to 260 ltrs.
65M&L for filling/charging Gas refrigerant R22/R134a/R438A in the sealed system of refrigerator of any make / capacity after checking leakage / pressure vacumising flushing the sealed unit including replacement of filter drier and capillary tube complete all as specified and directed
66S & F in repairs of thermostat switch suitable for any model / model complete all as specified and directed
67S & F in repairs electric Lamp 15 watt 230 volt AC thread / pin type suitable for any make / capacity of refrigerator complete all as specified and directed
68S & F in repairs compressor hermetically sealed type with suitable rated capacity electric motor and shall be equipped with over load and relay, 230Volt, 50 Hz, includind testing single suitable for water cooler 40/80 ltr capacity complete all as specified and directed.
69All as described Ser item No. 68 here-in-before but 60/120 ltr capacity.
70All as described Ser item No. 68 here-in-before but 150 ltr capacity.
71M&L for cleaning of water cooler tank from inner side with soda / Acid and de-scaling of water cooler to remove by brushing and soldering the leaking places and prepare the leak proof and complete all as specified and directed
72Dismantling the blower motor of water cooler 1/32 HP capacity, 230 volts, SP and taking out burnt out copper winding wire from motor and M&L for rewinding the electric motor with super enameled copper winding wire of same size and gauge including insulation material, varnish and bush, shaft and refixing the motor complete & testing on full load complete all as specified and directed Note:- Spare parts required to make functional the equipment shall be measured and paid seperatlly under relevant items as S & F in repairs.
73All as described Ser item No. 72 here-in-before but 1/6HP for 150 ltr water cooler / AC
74S&F in repairs of starting relay No. 522 / 1622 for water cooler complete all as specified and directed.
75S&F in repairs of starting capacitor 40-60 mfd 220 Volts complete all as specified and directed.
76All as described Ser item No. 75 here-in-before but for capacitor 60-80 mfd 220 Volts.
77All as described Ser item No. 75 here-in-before but for Running capacitor 15 mfd, 415 volts.
78All as described Ser item No. 75 here-in-before but for capacitor 10 mfd, 415 volts .
79All as described Ser item No. 75 here-in-before but for capacitor 36 mfd, 415 volts .
80S & F in repairs of PVC float valve with rod and plastic ball suitable for 1/2\\" bore of water cooler complete all as specified and directed
81S & F in repairs of LDPE 25 mm dia flexible pipe heavy duty with suitable clamp complete all as specified and directed
82S & F in repairs PVC pipe flexible type 32 mm dia for waste water draining complete all as specified and directed.
83S & F in repairs over load protector (OLP) for water cooler of any capacity complete all as specified and directed.
84S & F in repairs self closing push cock 15mm bore chromium plated brass heavy duty long body inner threaded complete all as specified and directed.
85S & F in repairs aluminium blade for blower motor of water cooler 80 ltrs to 150 ltrs complete all as specified and directed.
86S & F in repairs open type relay : CAJ-2612 complete all as specified and directed.
87All as described Ser item No. 86 here-in-before but CAJ-3612 complete all as specified and directed.
88S & F in repairs thermostat of water cooler of any type make complete all as specified and directed.
89S & F in repairs blower motor 1/32 HP 230 volt suitable for water cooler complete with base frame/and rubber bush make AUE/GE for 60 to 150 ltrs complete all as specified and directed.
90S & F in repairs drip tray made of stainless steel complete suitable for water cooler any make of 40 to 150 ltr capacity complete all as specified and directed.
91S & F in repairs water tank gasket for water cooler 40/80 ltr cap complete all as specified and directed.
92S&F in repairs wiring kit complete for water cooler complete all as specified and directed
93S & F in repairs compressor hermetically sealed with suitable rated capacity electric motor and shall be equipped with over load and relay, 230 volt , 50 Hz , including testing suitable for Deep freezer of capacity 200 / 300 Ltrs complete all as specified and directed
94All as described Ser item No. 93 here-in-before but 400 / 500 ltrs capacity complete all as specified and directed
95M&L for Filling charging gas refrigerent R12/R22/R-404A in the sealed system of Deep Freezer any make and capacity after checking the leakage / pressure vacuminising flushing the sealed system including replacement of capacity Tube, copper pipe for jointing, Gas filter complete all as specified and directed
96S & F in repairs starting relay as per sample for deep freezer complete all as specified and directed
97S & F Voltage Stabilizer 5 KVA with input variation between 130V to 250V with output voltage stabilized at 220 to 240V with accuracy of +/- 2.5%. Including taking down old one and depositing to MES store yard complete all as specified and directed.
98S & F Voltage Stabilizer 4 KVA with input variation between 170V to 250V with output voltage stabilized at 220 to 240V with accuracy of +/- 2.5% including taking down old one and depositing to MES store yard complete all as specified and directed.
99Taking out of water purifier (Aqua guard) or any other make / model and servicing , repair / replacement of spare parts of water purifer complete all as specified and directed.Note:-Spare parts required to make functional the equipment shall be measured and paid separetelly under relevant items as S & F in repairs.
100S & F in repairs pre filter candle (as per sample) kept in office of AGE E/M complete all as specified and directed
101S & F in repairs Activated Carbon filter complete all as specified and directed
102S & F in repairs SMPS/PCB circuit electric plate complete all as specified and directed
103S & F in repairs ultra violet lamp unit complete all as specified and directed
104S & F in repairs of PVC pipe nylon braided heavy duty suitable for water partition inlet connection and as required at site complete all as specified and directed
105S & F in repairs of chromomum plate tee 15/8 mm with valve for existing GI pipe connection complete all as specified and directed
106DESERT COOLER:Servicing / Disconnection desert cooler fan from desert cooler for repairing including cleaning, greasing,oiling , welding or M'seal at leaking place and refixing back after repair in original position .Note:- Spare required to make functional the equipment shall be measured and paid separately under relevant items as S & F in repairs.
107S&F in repairs rewinding desert cooler fan motor upto 4000cum cap any type/any model/make complete all as specified and directed
108All as described Ser item No. 107 here-in-before but 6000cum cap complete all as specified and directed.
109S & F in repairs of capacitor 4 mfd for kit fan / Exhaust fan complete all as specified and directed
110S & F in repairs of PVC flexible pipe 15 mm dia suitable for water distribution system of Desert cooler of any size / capacity complete all as specified and directed
111S & F in repairs of Vertical lifting pumps 1/70 HP, 230 Volts single phase complete all as specified and directed
112S& F in repairs of Sumersible pump suitable for desert cooler/ industrial cooler complete upto 4000/6000 cum complete all as specified and directed
113S &F in repairs of wood wool padding of desert cooler of suitable size 4000cum in wire net complete weight not less than 450 gms complete all as specified and directed
114S &F in repairs of wood wool padding of Industrial type cooler of suitable size 6000cum in wire net complete weight not less than 450 gms complete all as specified and directed
115Supply & install desert cooler (steel body) 4000 cum per hour,electric driven, 1 phase, 240 volts, AC heavy duty long body exhaust fan motor with , submersible water pump, ISI marked 3 core 1.50 sqmm pvc copper cable of minium 2 mtr long with plug top and control switches etc complete all as specified and directed
116S & F fan motor copper wounded suitable for desert cooler 230 volts, 50 Hz, single phase AC supply of capacity 4000 Cum complete all as specified and directed
117S & F fan motor copper wounded suitable for Industrial desert cooler 230 volts, 50 Hz, single phase AC supply of capacity 6000 Cum complete all as specified and directed
118S & F fan motor of Industrial cooler 3 phase, 415 V ,6000 Cum complete all as specified and directed
119S & F 3 core 1.5 sqmm copper flexible wire complete all as specified and directed
120S & F in repairs of Mettalic fan blade for desert cooler motor 4000 Cum complete all as specified and directed
121S & F in repairs of Mettalic fan blade for Industrial desert cooler motor 6000 Cum complete all as specified and directed
122S & F in repairs of 3 pin plug top 5 Amps complete all as specified and directed Please Enable Macros to View BoQ information
123S & F in repairs of 3 pin plug top 5 Amps complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56158234
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 17-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Maintenance And Repairs Summer Appliances And Other Connected Items Under Age E/M-I Of Ge (North) Meerut Cantt
Basic Detail
Tender No 8645/E8
Bidding Type Tender
Location
City Meerut
State Uttar Pradesh
Key Dates
Publish Date 24 Jun 2026
Submission Date 17 Jul 2026
Open Date 25 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 80000
Exemption Available
Document List
0d1f7de6-dac7-4437-aef9-4e2943d72e4b.html
8645TD.pdf
BOQ_867158.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

0d1f7de6-dac7-4437-aef9-4e2943d72e4b.html

pdf

8645TD.pdf

xls

BOQ_867158.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail