| 1 | Taking down existing unserviceable security / street light of any size & capacity from existing pole/building/wall for checking & replacement of unserviceable parts including checking of electric circuit complete all as specified & directed by Engineer in charge and refixing the same. Note : (i) The contractor's or his authorised rep/supervisor will receive complaint on each working day from JE E/M & will rectify the total no of complaints given to him on the same day & feedback to JE E/M daily evening.(ii) Penel recovery @ Rs 20 per / light complaint not rectified within 08 hrs will be recovered.(iii) The contractor will deploy one electrician (ITI Pass with minimum 3 years experience and one helper daily to attend the compalints. They will report at 0830 hrs daily to JE/Engineer-in-Charge.(iv) The contractor will ensure all safety measures of the workers incluiding insurance.(v) Necessarty tools & T&P required to rectify complaints will be provided to the labour employed by the contractor without anty extra cost to the Govt.(vi) Parts required for replacemwnt shall be measured as \\"Supply only\\" and paid seperately under respective items of BoQ. |
| 2 | Supply only LED plate module capacity 40 to 50 watt and support to existing light with 01 years replacement warranty complete all specified and directed. |
| 3 | Supply only LED plate module capacity 60 to 75 watt and support to existing light with 01 years replacement warranty complete all specified and directed. |
| 4 | Supply only LED plate module capacity 120 to 180 watt and support to existing light with 01 years replacement warranty complete all specified and directed. |
| 5 | Supply only LED street light driver capacity 40 to 50 watt and support to existing light with 01 years replacement warranty complete all specified and directed. |
| 6 | Supply only LED street light driver capacity 60 to 75 watt and support to existing light with 01 years replacement warranty complete all specified and directed. |
| 7 | Supply only LED street light driver capacity 120 to 180 watt and support to existing light a with 01 years replacement warranty complete all specified and directed. |
| 8 | S & F in replacement, new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP67 rodway luminaire 60 watt with heat resistant clear toughened glass, better optics for uniform distribution street/ Rodway luminair, with driver complete fitting with all accesoories and following specifications complete complete all as specified and directed by Engineer-in-Charge. (Note : (a) Lumen system efficiency of luminaire should be minimum 120 lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp Operating range : Minus 10°C to Plus 50°C (d) Power Fector : Minimum 0.95 (e) THD : Max 10% (f) IP rating : Minimum IP 66 (g) IK rating minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens (o) BIS Approved fixtures and driver (p) Rated life time : 50000 buring hrs @L70 (Average 10 to 12 hrs daily), Bracket for fixing and cable for connection shall be measured and paid separately and existing light make to serviceable with 01 years replacement warranty complete all specified and directed. |
| 9 | Supply and fixing in replacement new generation energy saving and environmental friendly long life versatile pressure die-cast aluminum IP-66 roadway luminair 72 watt with heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessoreis and followig specifications complete all as specified and directed.(a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt.(b) Input voltage range : 140 to 270 volts(c) Temp operating range : Minus 10°C to Plus 50°C(d) Power factor : Minimum 0.95 (e) TDH : Max 10% (f) IP rating : Minimum IP 66(g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 KV (inbuilt + extended) (I) CCT : 5700K.(m) CRI : Morethan 70 (n) Lens - High efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @ L70 (Average 10 to 12 hrs daily) Note : Bracket for fixing and cable for connection shall be measured and paid separately. |
| 10 | S & F in replacement energy saving & environmental friendly long life versatile pressure die cast aluminium IP66 LED fiood light cool/warm with high power LEDs as light source roadway luminaire 120 watt with heat resistant clear toughened glass,better optics for uniform distribution with driver complete fitting with all accessories and following specifications, complete all as specified and as directed :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)Note :- Bracket for fixing and cable for connection shall be measured and paid separately. |
| 11 | S & F in replacement energy saving & environmental friendly long life versatile pressure die cast aluminium IP66 LED fiood light cool/warm with high power LEDs as light source roadway luminaire 170 watt with heat resistant clear toughened glass,better optics for uniform distribution with driver complete fitting with all accessories and following specifications, complete all as specified and as directed :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide anglelens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)Note :- Bracket for fixing and cable for connection shall be measured and paid separately. |
| 12 | S & F in replacement energy saving & environmental friendly long life versatile pressure die cast aluminium IP66 LED fiood light cool/warm with high power LEDs as light source roadway luminaire 120 watt with heat resistant clear toughened glass,better optics for uniform distribution with driver complete fitting with all accessories and following specifications, complete all as specified and as directed :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide anglelens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)Note :- Bracket for fixing and cable for connection shall be measured and paid separately. |
| 13 | M & L in replacement PVC insulated, PVC sheathed Copper conductor electric cable 1.5 Sq mm 3Core 1100 volts grade for existing street light fitting on pole and existing light make to serviceable with 01 years replacement warranty complete all specified and directed. |
| 14 | Supply and fix in replacement of GI pipe 50 mm bore light grade for protection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches and existing light make to serviceable with 01 years replacement warranty complete all specified and directed. |
| 15 | M&L for preparation of old surface of steel tubular pole any size and type of poles and applying two coat aluminium paint over red oxide primer and applying two coats of synthetic enamel paint with black & white or yellow colour strips 30cm each up to 1.5 mtr height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80 mm high letters 150 mm above the top strip and existing light make to serviceable with 01 years replacement warranty complete all specified and directed. |
| 16 | S& F in replacement street light bracket made out of 32/40 mm dia GI tubing medium grade made to Shape 1.5 mtr long with fixing arrangement for LED fitting duly painted with two coats of synthetic enamel paint over a coat of primer zink MS clamp and back plates fabricated from steel section and nuts , bots washers etc and existing light make to serviceable with 01 years replacement warranty complete all specified and directed. |
| 17 | S & F in replacement pole box with fuse/MCB provision and suitable connector for single phase connections loop in and out 10 to 16 Sqmm 2 core/4 core aluminium armoured cable branch out 2.5 Sqmm single core copper PVC insulated cable enclosed in a thermoplastic polysterene/polycarbonate enclosure which shcould be shock proof safe IP 66/67 weather proof, rust proof, dust proof, water proof, flame retradant glow wire test at min 750 C internally embeded gasket with provision for cable entry through IP 66/67 thermoplastic metric size glands and / or grommets enxlosure size (155 mm x 210 mm x 92 mm) including taking down the old unsv pole mounting box and existing light make to serviceable with 01 years replacement warranty complete all specified and directed. |
| 18 | S & F in replacement Automatic Street Light Control Switch using Infrared Sensor based Nature Switch for automatic switching of street lights. Nature Switch operation should be based on Natural Lux Level. Required Illuminance level for switching On is <= 30 Lux and for switching OFF >=10 Lux. The Circuit should be suitable enough to take Thre phase load of 5 KW with 3 nos Contactors, 3 nos incoming MCBs& 3 nos Outgoing MCBs of 32-40 Amps each & circuit wiring (Copper) of min 10 sqmm. and existing light make to serviceable with 01 years replacement warranty complete all specified and directed. |
| 19 | S & F in replacement Automatic Street Light Control Switch using Infrared Sensor based Nature Switch for automatic switching of street lights. Nature Switch operation should be based on Natural Lux Level. Required Illuminance level for switching On is <= 30 Lux and for switching OFF >=10 Lux. The Circuit should be suitable enough to take Thre phase load of 12 KW with 3 nos Contactors, 3 nos incoming MCBs& 3 nos Outgoing MCBs of 40-63 Amps each & circuit wiring (Copper) of min 10 sqmm. and existing light make to serviceable with 01 years replacement warranty complete all specified and directed. |
| 20 | M & L in replacement Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4.0 mm size by means of bolts, nuts check nuts and washers earth lead protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) , GI light grade 20mm bore pipe for watering perforated at the bottom 7.5 meter long placed on top edge of earth plate common salt and charcoal filling test point , funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point all as specified or indicated including testing on completion |
| 21 | Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all specified and directed. |
| 22 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all specified and directed. |
| 23 | Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all specified and directed. |
| 24 | Supply, Laying DWC pipe size 63 mm OD/ 55 mm ID by Excavated Methed and existing light make to serviceable with 01 years replacement warranty complete all specified and directed. |
| 25 | M & L in replacement PVC insulated, armoured heavy duty electric cable with multi-stranded aluminium conductor 1100 volts grade cross sectional area 10 sqmm 2 core complete all specified and directed. |
| 26 | M & L in replacement PVC insulated, armoured heavy duty electric cable with multi-stranded aluminium conductor 1100 volts grade cross sectional area 10 sqmm 4 core complete all specified and directed. |
| 27 | M & L in replacement PVC insulated, armoured heavy duty electric cable with multi-stranded aluminium conductor 1100 volts grade cross sectional area 16 sqmm 4 core complete all specified and directed. |
| 28 | M & L in replacement PVC insulated, armoured heavy duty electric cable with multi-stranded aluminium conductor 1100 volts grade cross sectional area 25 sqmm 4 core complete all specified and directed.Note : Excavation & earth work shall be measured and paid separately under respective item of this Schedule. |
| 29 | Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT overhead lines with hack saw/axe to clear the LT/ line upto 3 metre on each side (Horizontal and / or vertical) including disposal of trimmed branches 2 KM away inside the cantonment area & clearing site complete all as specified and directed.Note :- 3 metre width on each side of LT line shall be cleared and each span having not less than 3/5 conductors and min30-40 m pole to pole distance. |
| 30 | Relaying, disconnectiong of street lights service wire after removing carbon , connecting joints with connector,repairing existing busbar/junction box & refixing the service wire from inside the pole to junction box, tape and other coonected accessories complete all as specified and directed. Please Enable Macros to View BoQ information |