| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE KARANJA NAME OF WORK : COMPREHENSIVE MAINT OF B/R AND E/M WORKS LIKE REPAIR, REPLACEMENT, MAINT OF LT UG CABLES, MCCBS, LT OUTDOOR/INDOOR PANELS, CHANGE OVER SWITCH AND CONNECTED MISC WORKS IN TUNIR, ABHIMANYU AND OTM AREA AT NAVAL STATION KARANJA CONTRACT AGREEMENT: CWE KJ(K) - OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided incl doors, gates for complete all as specified and as directed |
| 3 | Dismantling posts or struts (Wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground (posts embedded in in concrete, brick work, masonry work, etc. ) |
| 4 | Dismantling fencing wire mesh any type complete all as specified and as directed |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 6 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface hard or dence soil complete all as specified and directed |
| 7 | S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire mesh, etc.; flat iron fillets( for securing wire mesh etc.) including all necessary drilling, bolting or riviting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 8 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square but, length of boltexc 5cm but n exc 10cmlong.(Diameter of neck in 11 to 15 mm) complete all as specified and directed |
| 9 | S&F mild steel round bars 10mm dia and over, in horizontal support for chain link straining of fencing including cut to length, bent to shape required including cranking, bending spirally for hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) complete all as specified and directed. |
| 10 | Matrial and Labour for preparation of new steel surfaces any description nexc 10cm in width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. |
| 11 | Matrial and Labour Preparation of new previously untreated steel and iron surfaces of any description not other wise described over 10 centimetre width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and as directed. |
| 12 | S&Fof mild steel security chain link fencing 60mmx60mm with PVC coated mesh made out of 3.0 mm dia MS wire and 1.00mm thick PVC Complete all as specfied and directed. |
| 13 | Taking down and refixing of chain link fencing in same position after replacing of damage of fencing post complete all as specified and directed by Engineer–in-Charge |
| 14 | Taking down existing angle iron from wall embadded in PCC and refixing in the same opening/position complete all as specified and as directed by Engr-in-Charge. |
| 15 | Material and labour for cement concrete C-2 1:3:6 using 40mm graded crushed stone aggregate stone aggregate as in foundation, filling and mass concrete, in fencing pole all as specified and directed. |
| 16 | Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil all as directed. |
| 17 | Returning and filling in of excavated soil including spreading,levelling, watering and well ramming in layers not exceeding 25 cm each. |
| 18 | Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point. |
| 19 | Matrial and Labour for Sand cushioning/sand covering for underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid. |
| 20 | Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed. |
| 21 | Matrial and Labour for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection . |
| 22 | Matrial and Labour for GI pipe light grade 80 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection . |
| 23 | Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable all as directed. |
| 24 | Matrial and Labour for PCC type C2, 1:3:6 using (40 mm gradded stone aggregate) in foundations complete all as specified &directed. |
| 25 | Supply and fix in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps. Make: C&S/Schneider/L&T/ Indoasian/GE/Havells |
| 26 | Supply and fix in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1000 Amps. Make: C&S/Schneider/L&T/ Indoasian/GE/Havells |
| 27 | Supply and fix in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1250 Amps. Make: C&S/Schneider/L&T/ Indoasian/GE/Havells |
| 28 | Supply and fix in repairs MCCBs of following current carrying capacity. Make: Legrand/C&S/Schneider/L&T/ Indoasian/GE/Havells/HPL |
| 29 | 3 Pole MCCB 400 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 30 | 3 Pole MCCB 250 Amps, Adjustable type, 415 V, with breaking capacity 36KA rating |
| 31 | 3 Pole MCCB 200 Amps, Adjustable type, 415 V, with breaking capacity 36KA rating |
| 32 | 3 Pole MCCB 160 Amps, Adjustable type, 415 V, with breaking capacity 36KA rating |
| 33 | 3 Pole MCCB 125 Amps, Adjustable type, 415 V, with breaking capacity 16KA rating |
| 34 | 3 Pole MCCB 100 Amps, Adjustable type, 415 V, with breaking capacity 16KA rating |
| 35 | 4 Pole MCCB 630 Amps, Adjustable type,415V, with breaking capacity 50KA rating |
| 36 | 4 Pole MCCB 500 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 37 | 4 Pole MCCB 400 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 38 | 4 Pole MCCB 350 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 39 | 4 Pole MCCB 250 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 40 | 4 Pole MCCB 200 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 41 | 4 Pole MCCB 100-160 Amps, Adjustable type,415V, with breaking capacity 36KA rating |
| 42 | 4 Pole MCCB 630 Amps, 415 V, Microprocessor release with breaking capacity 50 KA |
| 43 | 4 Pole MCCB 400 Amps, 415 V, Microprocessor release with breaking capacity 36 KA |
| 44 | 4 Pole MCCB 250 Amps, 415 V, Microprocessor release with breaking capacity 36 KA |
| 45 | 4 Pole MCCB 160 Amps, 415 V, Microprocessor release with breaking capacity 36 KA, 160 A rated |
| 46 | Supply and fix in repairs Isolator 415 Volts of following current carrying capacity. Make: HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells |
| 47 | 4 Pole 63 Amps |
| 48 | 4 Pole 100 Amps |
| 49 | Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 3.5/4 core XLPE , armoured, electric power cables (heavy duty) with aluminium conductor of the following size including dismantling old one. |
| 50 | 25 Sqmm 4 core |
| 51 | 35 Sqmm 3.5 core |
| 52 | 50 Sqmm 3.5 core |
| 53 | 70 Sqmm 3.5 core |
| 54 | 95 Sqmm 3.5 core |
| 55 | 120 Sqmm 3.5 core |
| 56 | 150 Sqmm 3.5 core |
| 57 | 185 Sqmm 3.5 core |
| 58 | 240 Sqmm 3.5 core |
| 59 | 300 Sqmm 3.5 core |
| 60 | 400 Sqmm 3.5 core |
| 61 | Matrial and Labour for detecting LT UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave reciever, cable indentification instrument , cable tracer for exact location of under ground cable routes. Note: The rate quoted deemed to be inclusive of transportation of equipment and charges for service engineer . Note : The fault locator will be arranged by Contractor Only |
| 62 | Disconnecting incoming and outgoing connections, taking out and overhauling of manually operated, draw out type air circuit breaker of any make 3 pole, 415 volts, AC, current rating 800-1600 A, including cleaning/ oiling/ greasing all mechanical moving parts, replacement of defective accessories, racking in and connecting incoming/ outgoing cables complete all as specified and directed. Note :Accessories required for replacement shall be measured & paid separately under respective item of this schedule. |
| 63 | Supply and fixing following accessories suitable for ACB of any make and capacity :- |
| 64 | Auxiliary contact |
| 65 | motor |
| 66 | Trip alarm contact |
| 67 | Under voltage release |
| 68 | Shunt realease |
| 69 | Insulation barrier |
| 70 | Earth fault release |
| 71 | Racking interlock |
| 72 | Matrial and Labour for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 50 sq.mm.Make :- M-SEAL / BIRLA 3 M LTD / RAY CHEM |
| 73 | All as per Item No.33 herein before but for cable of size 3.5 core 95 to 120 sq.mm. |
| 74 | All as per Item No. 33 herein before but for cable of size 3.5 core 150 to 185 sq.mm. |
| 75 | All as per Item No. 33 herein before but for cable of size 3.5 core 240 to 300 sq.mm. |
| 76 | All as per Item No. 33 herein before but for cable of size 3.5 core 400 sq.mm. |
| 77 | Matrial and Labour for heat shrinkable End Termination Kit (with colour limbs of Red, Yelllow, Blue & Black) for LT UG cable complete for making serviceable for aluminium conductor cable of size 3.5/ 4 core 50 to 95 sq.mm.Make :- M-SEAL / BIRLA 3 M LTD / RAY CHEM |
| 78 | All as per Item No.38 herein before but for cable of size 3.5 core 120 to 185 sq.mm. |
| 79 | All as per Item No.38 herein before but for cable of size 3.5 core 240 to 300 sq.mm. |
| 80 | All as per Item No.38 herein before but for cable of size 3.5 core 400 sq.mm. |
| 81 | Matrial and Labour for Maintenance and attending complaints / breakdowns at Naval Station Karanja area comprising of LT panels, over head lines/ underground LT cables upto main distribution boards at buildings including repairs of day to day maintenance of LT panels by providing necessary hinges, nuts & bolts, welding and painting at site to LT Panels where necessary for smooth & trouble free LT power supply including rectification of minor defects to electrical controls gear/accessories complete all as specified and directed. |
| 82 | Supply and fix in repair LED indicating lamp of 230 volts AC to show R, Y & B phase with RED, YELLOW and BLUE in colour complete all as specified and directed by Engr-in-Charge. |
| 83 | Supply and fix in repair current transformer of CT ratio 100/5A to different capacity LT Panels complete all as specified and directed by Engr-in-Charge. |
| 84 | Supply and fix in repair digital multifunctional meter having LCD displays showing single and three phase current and voltages for different capacity of LT Panels complete all as specified and directed by Engr-in-Charge. |
| 85 | Matrial and Labour in repair for control wiring to existing LT Panel with 1/2/2.5/4 Sqmm FRLS wires as required at site with necessary cable duct, Volt meter, Ammeter, alluminium Bus bars, selector switch etc as required at site and connectors with suitable wire lugs complete all as specified and directed by Engr-in-Charge. |
| 86 | Matrial and Labour for maintenance of LT panels by providing necessary hinges, nuts & bolts, welding and painting at site to electric control panel/LT Panel/Feeder Piller box /Bus bar panel any type and any size of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 87 | Matrial and Labour Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size |
| 88 | Supply and Fix aluminium bus bar red,yellow,blue and black colour coded heat shrinkable sleeve of size 25 x 5 mm fixed with suitable ss nut bolts etc in LT Panel complete all as specified and directed |
| 89 | Supply and Fix aluminium bus bar red,yellow,blue and black colour coded heat shrinkable sleeve of size 40 x 10 mm fixed with suitable ss nut bolts etc in LT Panel complete all as specified and directed |
| 90 | Supply and Fix aluminium bus bar red,yellow,blue and black colour coded heat shrinkable sleeve of size 60 x 10 mm fixed with suitable ss nut bolts etc in LT Panel complete all as specified and directed |
| 91 | Supply and fixing MS nut bolts,SS nut bolts ,clamp ,screw of different size and sample complete all as specified and directed. |
| 92 | Matrial and Labour for testing of Lightning Conductor & earthing except new earthing 40 to 43 here-in-after of various EM installation in the presence of Engineer-in-Charge & maintaining record of tests for lightning conductor as per IAFW -2215 by removing all connection and the resistance of earthing & lightning protection network should not exceed 5 Ohm in every building/Panel showing the details of defective earthing & lightening protection system. Items to be repaired/renewal during record of sets for lightening conductors as per IAFW 2215 & also test results to be recorded after repair/renewal. Note :- (i) The earthing showing result beyond 10 ohm to be renewed and shall be measured & paid for separately under relevant item of Sch 'A'. (ii) The test result after renewal of earthing and replacement of defective conductor also be recorded in earthing test book as per IAFW-2215 for lightening conductor & cost for the same is deemed to be included in unit rate of above item. (iii) The unit rate quoted shall be deemed to be included for the test results of all existing earthing point, date of testing and renewal etc to be written on wall of each building as per direction from engr-in-charge with out any extra cost. (iv) The testing of new earthing covered under item Nos 40 to 43 are not covered in this item. |
| 93 | Matrial and Labour in repair Earthing with galavanised steel earth plate elctrode 600mm x 600mmx6mm thick buried directley in ground, (earth pit not less than 2.25m below ground level), with the top edge of the plate not less then 1.5 m below the normal ground level, connected to 4 mm GI wire and riveted to earth plate,GI earth wire will be protected by using 40mm bore GI pipe (light grade) from earth plate to equipment and watering pipe 20mm bore (light grade), chamber and coping shall be made in PCC (1:3:6) type C1 using 20mm graded stone aggregate, RCC pit cover 50mm thick in 1:2:4 type B1 using 20mm graded stone aggregate reinforeced with 8mm dia TMT bar @ 80mmc/c both way with lifting hook made out of 8mm dia TMT bar duly embedded in RCC cover in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No 3 of SSR Part I and as specified including charcoal dust, common salt complete and earth lead connected to earthing test point/main point and testing of earthing complete as directed.(Note:- Main earthing lead from earth plate to test point & upto 7.5mtr to be provided and the cost of the same shall deemed to be included in the quoted rate). |
| 94 | Matrial and Labour in repair earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 25 x 4 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point all as specified and indicated including testing on completion |
| 95 | Matrial and Labour in repair earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point all as specified and indicated including testing on completion |
| 96 | -Ditto- all as per srl item No. 56 hereinbefore, but with copper earth electrode of size 60 cm x 60 cm x 3.15 mm thick & earth continunity lead of size 20 mm x 3 mm copper strip, complete all as specified and directed 'Note :-for item No. 53 to 56 :- (i) copper/Aluminium strip upto 7.5 m will be deemed to be inluded in quoted rate of item No. 53 to 56 respectively. (ii) The earth chamber shall be constructed 50 cm away from the edge of earth pit & the cost of the same is deemed to be included in rate quoted for above items. |
| 97 | Supply & fix in repairs GI funnel suitable for GI/ Copper earthing complete all as specified and directed. |
| 98 | Matrial and Labour for Raw salt with mixiing with water and pouring in existing earthing complete all as specified and directed. |
| 99 | Matrial and Labour for PCC (1:2:4) type B1, using (20 mm graded stone aggretgate) for earth chambers as in repairs, coping for GI pipe post including necessary form work, excavation in soft loose soil, returning in filling and removing surplus soil to a distance n. exc 50 mtr and deposing where directed. |
| 100 | Removing existing worn out CI cover with angle iron frame of earth chamber and supply and fix new CI cover of size 30 cm x 30 cm x 6 mm thick fixed in frame made out of mild steel angle iron 40 mm x 40 mm x 6 mm thick with and including locking and lifting arrnagement, painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed |
| 101 | Supply and lay 20 mm dia, GI pipe, medium grade, burried in trenches as earth continuity protection as in repairs, including necessary excavation and earth work in hard/dense soil, returining & filling in, watering and well ramming, removal of surplus soil to a distance not exc 50 mtrs complete all as specified and directed. |
| 102 | Supply and lay 40mm dia, GI pipe, light grade, burried in trenches as earth continuity protection as in repairs, including necessary excavation and earth work in hard/dense soil, returining & filling in, watering and well ramming, removal of surplus soil to a distance not exc 50 mtrs complete all as specified and directed. |
| 103 | Supply and Fix in repair GI or steel wire 4mm on wall/surface for conductors or as earth continuity conductor all as specified and directed. |
| 104 | Supply and Fix in repair GI strip of 25x4mm on wall/surface for conductors or as earth continuity conductor all as specified and directed. |
| 105 | Supply and Fix in repair GI strip of 32x6mm on wall/surface for conductors or as earth continuity conductor all as specified and directed. |
| 106 | Supply and Fix in repair copper strip of 20x3mm on wall/surface for conductors or as earth continuity conductor all as specified and directed. |
| 107 | Matrial and Labour for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, Outdoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following : |
| 108 | (A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 315 Amps – 01 Nos .Make : L&T/ABB/SIEMENS(ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 200 Amps - 01 Nos .Make : L&T/ABB/SIEMENS(iii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 125 Amps – 02 Nos .Make : L&T/ABB/SIEMENS(iv) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps- 03 Nos Make : L&T/ABB/SIEMENS(v) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(vi) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. MAKE AE/NSDA/PRINZ(vii) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, Make TEKNIK/SELECT/L&T(viii) Aluminium bus bar of Rating 800 Amp R-Y-B phases and Neutral.(ix) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted.(x) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. Total in Figures 0.0 23 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |