| 1 | Dismantling of fencing posts or struts (wood, steel or R.C.C.) any section embedded in conrete, brick work, masonry etc, including taking out embedded portion and making post work clear for bedding of new postsdisturbed ground all as specified . |
| 2 | Dismantling of fencing wire mesh, barbed wire fencing, any type all as specified and directed |
| 3 | M&L for PCC 1:4:8 type B2 using 40mm gragded stone aggregate for post hole complete all as specified and directed. |
| 4 | M&L MS Angle iron post or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mest etc) including all necessary drilling bolting or riverting etch and similar work confirming to /fe 290 Gde E-165 complete all as specified and as directed |
| 5 | Supply only chain link MS galvanised fencing of any size square mesh of any dia wire directed by Engr-In Charge. |
| 6 | Fixing only chain link MS galvanised fencing any size or type as required complete all as specified and directed. |
| 7 | S & F MS 10 mm dia round bar and fixed independently to angle iron for chain link fencing cut to length, bend to shape reqd and directed including taking down old rusted part complete all as specified and directed. |
| 8 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5 cm of 11 to 15mm dia of neck. |
| 9 | S&F repair galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails strain-ing bolts, including, tying at crossing with and provision of galvanised mild steel wire, staple oe steel pins etc as directed by EIC (each line wire to be measured) |
| 10 | S&F in repair barbed razor type concertina coil 9 SWG hot galvanised spring tensile wire of UTS 145 to 150 Newton per square mm zinc coating 250-300 grams per squre metre dia of coil when unstretched 610 mm covering 8 to 10 running meter per coil and minimum weight of coild (GI strip) 1.625 kg per running metre hot dip galvanised razor ribbon tape of size 0.50 mm thickness, 19 mm wide before wrapping on central core wire fixed 1.66 mm thick GI clip minimum 25 nos per running metre and special nut bolt to hold two coils together and extra two rows parallel wire of 10 gauge ,including dismantling of concertina coil any type complete all as specified and as directed |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 12 | Supplying & fixing Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 |
| 13 | M&L Plates 8-10mm thick (plain or chequered) channels square cut or notched (ordinary and counter sunk) fixed to angle iron frame complete all as specified. |
| 14 | M & L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of 2K polyurethrane (PU) rasin base and hardner component over and including zinc rich epoxy primer complete all as specified and directed Make :- Asian Paints (Epoxy +PU system)/ Excel polyurethrane /2KPU)/ Indigo Paint (2K PU System) |
| 15 | M & L for preparation of old steel surfaces exc 10 cm width or girth and applying one coats of 2K polyurethrane (PU) rasin base and hardner component complete all as specified and directed. Make :- Asian Paints (Epoxy +PU system)/ Excel polyurethrane /2KPU)/ Indigo Paint (2K PU System) |
| 16 | Taking down cement plaster of any description on brick walls or concrete surfaecs etc. including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed . |
| 17 | M&L plastering 20mm thick in CM 1:4 on stone or concrete surfaces on external surface of walls in two coats (15mm thick backing coat and 5mm thick setting coat) mixed with water proofing compound finished fair & even without using extra cement. |
| 18 | Demolition of brick or strone / boulder work, built in cement mortar in portion/ part ordered to be dismantled including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed. |
| 19 | M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified & directed. |
| 20 | M&L for applying two coats of cement paint over one coat of alkali resistant priming paint on newly plastered surface of wall including preparation, watering to surfaces all as specified. |
| 21 | Demolition of cement concerete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified & directed by Engineer in charge. |
| 22 | S&F MS TMT bars 8 mm dia and above cut to length, bend to shape required including cranking and bending, spirally hooking ends and binding with & including mild steel wire (annealed) not less than 0.90 mm dia all as specified. |
| 23 | M&L for precast RCC slabs 1:2:4 type B1 (using 20mm graded stone aggregates) such as manhole cover and similar articles with plain fair faces, including chamfers, weatherings, throating etc. and setting in in CM 1:4 including formwork complete all as directed |
| 24 | Material & Labour for providing and fixing stainless steel (Grade 304) railing/ grill made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. Please Enable Macros to View BoQ information |