| 1 | Dismentaling of pump for over hauiling including greasing, gland packing, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineer-in- Charge. |
| 2 | Providing & fitting fixing C.I coupling complete with nuts & bolts of approved quality. |
| 3 | 150 mmφ |
| 4 | 190 mmφ |
| 5 | Providing & fitting fixing coupling nuts & bolts (all Size) of approved quality. For LI |
| 6 | Providing & fitting fixing coupling rubber bush (All Size) of approved quality.For LI |
| 7 | Providing & fitting fixing coupling star bush (All Size) of approved quality. |
| 8 | 150 mmφ |
| 9 | 190 mmφ |
| 10 | Providing & fitting fixing Pump Shaft of approved quality. |
| 11 | Providing & fitting fixing Shaft sleeve of approved quality.Cast iron (CI) |
| 12 | Providing & fitting fixing Shaft sleeve nut of approved quality.Cast iron (CI) |
| 13 | Providing & fitting fixing C.I. Impeller of approved quality for Horizontal pump |
| 14 | Providing & fitting fixing coupling/ impeller Key of approved quality. |
| 15 | Providing & fitting fixing Casing ring of approved quality |
| 16 | 150 mm dia |
| 17 | 8 mm thick |
| 18 | Providing & fitting fixing C.I. gland of approved quality |
| 19 | Providing & fitting fixing Nuts & bolts full threaded 10mm dia and 100 mm long (Stag nut) for gland of approved quality |
| 20 | Providing & fitting fixing Lantern Ring for pump of approved quality |
| 21 | Supply & fitting fixing ball bearing of approved quality for pump required during overhauling. |
| 22 | 6305 Ball bearing (TATA /SKF) |
| 23 | 6306 Ball bearing (TATA /SKF |
| 24 | 6308 Ball bearing (TATA /SKF |
| 25 | 6309 Ball bearing (TATA /SKF |
| 26 | 6310 Ball bearing (TATA /SKF |
| 27 | Supplying & fitting fixing of GI . bend of approved quality |
| 28 | 125 mm dia |
| 29 | 150 mm dia |
| 30 | Hiring charge of welding set of single phase with operating staff and carrying upto the site of work including loading and unloading (both way) complete as per direction of Engineer-incharge. |
| 31 | Providing & fitting fixing M.S flange (10mm thick) at site of work of approved quality. |
| 32 | 150 mm dia |
| 33 | 125 mm dia |
| 34 | Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality. |
| 35 | 150 mm dia |
| 36 | 125 mm dia |
| 37 | Providing & fitting fixing MS hose clamp with nuts & bolts etc. complete at site of work of approved quality.150 mm dia |
| 38 | Providing & fitting fixing PVC suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality.150 mm dia |
| 39 | Providing & fitting fixing C.I tail piece of approved quality at site of work.150 mm dia |
| 40 | Providing & fitting fixing C.I foot valve spare Parts of 125/150 mm dia at site of work of approved quality. |
| 41 | C.I foot Valve wieght |
| 42 | C.I foot Valve ring |
| 43 | C.I foot Valve net |
| 44 | Providing & fitting fixing C.I foot valve of heavy duty at site of work of approved quality.150 mm dia |
| 45 | Providing & fitting fixing foot valve leather washer (6 mm thick) of heavy duty at site of work of approved quality.150 mm dia |
| 46 | Supplying & fitting fixing of ball bearing of approved quality (TATA/SKF MAKE) for motor. |
| 47 | 6308 Ball bearing (TATA /SKF) |
| 48 | 6309 Ball bearing (TATA /SKF) |
| 49 | 6310 Ball bearing (TATA /SKF) |
| 50 | Dismentaling of old pump/motor from base & stacking of materials & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge. |
| 51 | Dismentaling of G.I pipe including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge. 125/150 mm dia |
| 52 | Dismental of horizontal pump and motor of 20/25 HP from the base and carrying the pump set to the nearest workshop for repairing the body thread of stag nut and carrying the same to the scheme and fitting fixing the pump set as before as per direction of the Engineerin-charge. |
| 53 | Dismentaling of pump for over hauiling including greasing, gland packing, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineerin-Charge. |
| 54 | Dismentaling of G.I bend including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge.125/150 mm ɸ |
| 55 | Installation of pumpset including carriage of materials from M.I store of Resource Division to site of work including trial run for 10hrs. in two spell. |
| 56 | Dismentalling of motor for vernishing, heating etc. complete in/c reinstallation and trial run for 10 hrs in two spell complete as per direction of Engineer-in-charge |
| 57 | Supplying and fitting fixing of asbestos rope of best quality as per direciton of Engineer-in-charge. 10 to 12 mm thick |
| 58 | Supplying and greasing/applying of grease of approved quality as per direction of Engineer-in-charge |
| 59 | Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, dressing of sides where required, ramming of bottoms , depth upto 1500 mm ( slope -1 in 200 ) including getting out the excavated soil and back filling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavted soil with all required leads as per Chapter-2 of CPWD specification and direction of the Engineer- in Charge. B. G.I/ C.I/D.I pipes in new work,A) All kinds of soil. i) for Pipes exceeding 90 mm dia but not exceeding 300 mm dia, |
| 60 | Labour charge for laying of G.I pipe conforming IS 1161,3589 & 1239 including fitting fixing complete as per direction of Engineer-in- Charge. |
| 61 | 150 mm dia nominal bore(medium) |
| 62 | 125 mm dia nominal bore(medium) |
| 63 | Supplying &fitting fixing ofspare partsfor submersible pump5 HPto 25 HP of approved quality as per direction of Engineer-in-Charge.Motor bush (Brass make) . |
| 64 | Providing & fitting fixing of pannel board of local teak wood for fitting & fixing of electrical items including 2 nos. MS angle post ( Size 50X50X6mm 2.80 Mtr. long) nuts& bolts etc. for errection of the same by 1 : 1.5 : 3 cement concreate casting (1feetX1feetX2feet) below the ground level and painting two or more coats of synthetic enamel paint on primer as per direction of Engineer-in-Charge.Size 1.80X1.20X0.025 mtr. |
| 65 | Dismentling of pannel board by disconnection of all electrical equipments & stacking of materials & return the same to SubDivisional store as per direction of the Engineer-in-charge. |
| 66 | Labour charge for reinstallation of all electrical equipments (dismentalled serviceable materials, if any additional/ replacement of electrical eqiupments required will be paid separtely)on the pannel board including trial run for 10 hrs in two spell complete as per direction of the Engineer-in Charge. |
| 67 | Providing & fitting fixing Steel sheet enclosed switch Fuse unit (Suitable for DIN fuse) triple pole with Neutral Link (TPN) , 415/500 Volt, complete as per direction of Engineer-in-Charge |
| 68 | Current range 63 Amps. |
| 69 | Current range 200 Amps. |
| 70 | Providing & fitting fixing of Fully Automatic Star Delta type Motor startar ( 3ph, 50 Hz, 415V 25HP/18.7 kw Relay range within 17-25) in steel sheet enclosure with Conductor , Timer etc. complete suitable for motor pump Havells/L&T/BCH make as per direction of Engineerin- Charge. |
| 71 | Supplying & filling of Transformer Oil in the oil tank of manually operated oil immerged starter of approved quality. |
| 72 | Repairing of OSCO starter including supplying & fixing of necessary spare parts as per direction of Engg.- In - Charge. |
| 73 | Stand finger |
| 74 | Gola Finger |
| 75 | CT finger |
| 76 | Magnet Coil |
| 77 | Circuit board for Osco starter of Backelite Make |
| 78 | Supplying & fitting fixing manually operated oil immerged starter of approved quality.a) 30 Hp Osco/BCH Make |
| 79 | Supplying and fitting fixing AC Voltmeter (Moving Iron) on the panel board of approved quality.SMI-144, Range 0-400 to 0-500 |
| 80 | Supplying and fitting fixing AC Ammeter (Moving Iron) on the panel board of approved quality.SMI-144, Range 0-10A |
| 81 | Supplying & fitting fixing power capacitor (ISI Marked) of approved quality.12.5 KVAr power capacitor |
| 82 | Providing & fixing 200 Amps busbar of size 600X 450X100 mm with 4 nos. copper strip of size 450X40X4 mm of approved quality. |
| 83 | Supplying & fitting fixing of PVC insulated Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality.7/16 Copper Wire |
| 84 | Supplying and fitting fixing of selector switch on the panel board of approved quality. |
| 85 | Supplying and fitting fixing of Indicator bulb (Flush type containig 3nos batton holder with bulb)) on the panel board of approvedquality. |
| 86 | Supplying & fitting fixing kit cut for main & sub-main swich (Male & female) as per direction of the Engineer in Charge. |
| 87 | 63 Amps main switch |
| 88 | 200 Amps main switch |
| 89 | Supplying and fitting fixing of 3 pole power conductors of different type, range from 25-300 AC-3 suitable for Fully Automatic Star Delta type Motor startar L&T , BCH, Havells make as per direction of Engineer-in-Charge.Type ML1.5 |
| 90 | Supplying and fitting fixing of spare contact kit , type ML 1.5/2.0/3.0/4.0/6.0 suitable for Fully Automatic Star Delta type Motor startar L&T,BCH, Havells make as per direction of Engineer-in- Charge.Type ML1.5 |
| 91 | Supplying and fitting fixing of spare coil, type ML 1.5 range suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in- Charge. |
| 92 | Supplying and fitting fixing of bimetal overload relay, relay range 20-32, & 28-42, directly operated suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in-Charge. |
| 93 | Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:-a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 94 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level:a) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 95 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 96 | Providing and fixing MS bolts including nuts and washers complete as per standard design:-Above 300mm length.- |
| 97 | Providing and fixing G.I. pipes medium class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per chapter 20 of CPWD specification and direction of the Engineer- in - charge.A. External work i. 40 mm dia. nominal bore- For Priming line |
| 98 | Labour charge for lifting of hose pipe from river bad by dismantling of G.I. suction line and refitting the same after cleaning the pipe with necessary filling etc. complete as per direction of the Engineer in charge. |
| 99 | Reparing of 125mm dia sluice valve by dismentling in/c changing of sluice valve spindle, key, gasket, nuts and bolts etc. and refitting fixing the same after making good in the exisitng delivery line as per direction of the Engineer in charge. |
| 100 | Labour charge for dismentling of 125mm dia non-return valve and refitting fixing the same after proper washing and ressemling the C.I seperator plate etc as per direction of the engineer in charge. |
| 101 | Providing and fitting fixing of brass fullway valve with handle in the GI pipe line including cutting, threading etc. complete as per CPWD specification and direction of the Engineer - in -charge.40 mm dia |
| 102 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge.40 mm dia |
| 103 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.40 mm dia |
| 104 | Providing and fixing G.I. equal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.40 x 40 x 40 mm dia |
| 105 | Labour charge for checking the panal board and making safe including dismantling and refitting fixing of wire and electrical equipments and reconstruction etc complete as per direction of the engineer in charge. |
| 106 | Repairing of 15/20/25 HP starter by dismantling in/c changing of magnetic coil, connecting finger, oli finger rod etc complete and refitting fixing the same as per direction of the Engineer in charge. |
| 107 | Repairing charge of busber including changing of copper strip with neccesary screws,nuts, washer including proper reconnection and wiring etc. complete as per direction of the engineer in charge. |
| 108 | Repairing of pump shaft by welding, polishing etc complete as per direction of the Engg-in-Charge. |
| 109 | Labour charge for dismantling,turning making alignment of pump motor shaft for suitable fitting coupling,bearing,sleeve bush etc as per direction of the Engg-in-Charge. |
| 110 | Repairing of impeller by welding, polishing etc complete as per direction of the Engg-in-Charge. Please Enable Macros to View BoQ information |