| Sl. No. | Item Description |
| 1 | GST % for the tender Please select the rate of GST in cell AY13. Rate selected shall be applicable for the entire BoQ. |
| 2 | MPPL P25 - CSW Civil - IPIG 03 NON ITC |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in widt h as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed b y the Engineer-in-Charge : |
| 4 | In all kinds of soil |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in d epth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m. |
| 6 | Filling the excavated earth to required grade, level & profile in low lying areas including watering, ramming, compacting at optimum moisture content to 90% of Proctor's density consolidation by rolling with 8 to 10 tonne power roller in layers not exceeding 20 c m thickness, including clearing the area by cutting of shrubs, bushes, grass, vegetation, debris etc. stacking and disposing out of plot area to an unobjectional area as directed by Engineer-in-Charge complete in all respects inclusive of cost of all labour, mate rials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 8 | 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from n atural sources] |
| 9 | 1:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from n atural sources] |
| 10 | 1:3:6 (1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from n atural sources) |
| 11 | 1:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from n atural sources] |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 13 | Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 15 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anc hor blocks and the like. |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level : |
| 19 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above pl inth level : |
| 21 | Thermo-Mechanically Treated bars of grade Fe-500 D or more |
| 22 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concr ete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement content as per approved design mi x, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, inc luding admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per directions of the Engineer-in-Charge. [Note : Cement content considered in this item is @ 3 30 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.] : |
| 23 | All works upto plinth level |
| 24 | All works above plinth level upto floor V level |
| 25 | Extra for providing richer mixes at all floor levels. [Note: Excess/ less cement over the specified cement content used is payable/ recoverable separately] : |
| 26 | Add for using extra cement in the items of design mix over and above the specified cement content therein. [Note: Unit \\"QN\\" shall me an \\"QUINTAL\\"] |
| 27 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 28 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : |
| 29 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 30 | Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to fl oor V level in all shapes and sizes in : |
| 31 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 32 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite (of any colour and s hade) for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour an d texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matc hing pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels : |
| 33 | Area of slab up to 0.50 sqm |
| 34 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrange ments for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27. 5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 (Part-1) and M.S. top co ver of required thickness for rolling shutters : |
| 35 | 80 x 1.25 mm M.S. laths with 1.25 mm thick top cover |
| 36 | Providing and fixing ball bearing for rolling shutters. |
| 37 | Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc ., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboar ds, supports for cable trench, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint \\"EPILUX 155\\" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalen t make as per manufacturer’s recommendation, complete in all respect including cutting to required size welding of joints, fixing a nchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.c omplete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directio ns of the Engineer-in-Charge. (excluding the cost of concrete work). |
| 38 | Supplying, fitting and fixing hot dip galvinised barbed line wire through holes in fencing posts (already made in the body of the po st), tightening and fixing the wire in tight condition with straining bolts (straining bolts at end post) including the cost of cutt ing and lapping joints, making holes, straining bolts, galvanised staples, binding wires etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. |
| 39 | Supplying and placing in position 5.0 mm thick steel chequered plates over cable ducts, valve pits etc. including provision for lift ing arrangements complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifica tions and directions of the Engineer-in-Charge. |
| 40 | Supplying, fitting and fixing punched tape concertina spiral coil of 50 turns per coil having core wire of 2.6 mm diameter made of h igh carbon spring steel of high tensile strength as per IS:4454 (Part-I, Grade-II) having minimum galvanising coating thickness equi valent to 230 grams per square metre and low carbon steel strip of 0.5 mm thickness having a series of barbes punched all along the length on both sides of the strip at regular interval as per IS:513, DD quality having minimum galvanising coating thickness of 12 m icrons. Hardness of tape should be between 137-180 VPN (Victor Penetration Number). The coil should be clipped sufficiently at regul ar intervals. The coil should not be stretched for more than 6.0 m length and the minimum diameter of the coil in the closed conditi on should not be less than 600 mm complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per dr awings, specifications and directions of the Engineer-in-Charge. |
| 41 | Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 la id to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labo ur, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. |
| 42 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make & colour using acid and/or alkali resisting mor tar bedding and filling joints with acid and/or alkali resisting cement as per IS:4457, all complete as per specifcations and direct ions of the Engineer-in-Charge : |
| 43 | In flooring on a bed of 10 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) : |
| 44 | In dado/ skirting on 12 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) : |
| 45 | Providing and laying Polished Granite stone slab (Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent) flooring in required de sign and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 1 8 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. al l complete as specified and as directed by the Engineer-in-Charge. |
| 46 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigmen t to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse san d) : |
| 47 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cemen t: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and poli shing complete. |
| 48 | Providing gola 75x75 mm (in 75x75 mm deep chase) in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and do wn gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design. |
| 49 | Making Khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggr egate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse s and) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 50 | Providing and fixing on wall face Unplasticised Rigid PVC (uPVC) rainwater pipes (110 mm diameter, single socketed) conforming to IS :13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion. |
| 51 | Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipe s conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion : |
| 52 | Coupler (110 mm) |
| 53 | Single Push-fit Coupler (110 mm) |
| 54 | Bend- 87.5 Degrees (110 mm) |
| 55 | Shoe - Plain (110 mm) |
| 56 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 57 | 1:6 (1 cement : 6 fine sand) |
| 58 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 59 | 1:4 (1 cement : 4 fine sand) |
| 60 | 6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand) |
| 61 | Providing & fixing galvanized chicken wire net 20 Gauge, 20 mm mesh size in plastering work at the junction of RCC Columns/ Beams & brickwork as directed by the Engineer-in-Charge. |
| 62 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 63 | Water thinnable cement primer |
| 64 | Finishing walls with textured exterior paint of required shade : |
| 65 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 66 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 67 | Two or more coats on new work |
| 68 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wa ll surface to prepare the surface even and smooth complete. |
| 69 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 gra ms/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour : |
| 70 | Two coats |
| 71 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, includ ing painting of fittings and brackets, cutting and making good the walls wherever require : |
| 72 | White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap |
| 73 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete : |
| 74 | Flexible Pipe : |
| 75 | 32 mm diameter |
| 76 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board grou nd fixed to wooden cleats with C.P. brass screws and washers complete. |
| 77 | Stainless steel liquid soap container (spring loaded push type) with lid and brackets fixed to P.V.C. cleats with C.P. brass screws, etc. |
| 78 | Internal Work - Exposed on wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. Th is includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per directions of the E ngineer-in-Charge : |
| 79 | 15 mm nominal outer dia pipes |
| 80 | 20 mm nominal outer dia pipes |
| 81 | External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge : |
| 82 | 50 mm nominal dia pipes |
| 83 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 84 | 32 mm nominal bore |
| 85 | Providing and fixing 15mm diameter C.P. brass angle valve as per following with C.P. copper connecting pipe 375mm long or as require d including nuts, washers, C.P. brass flange, etc. including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Ch arge : |
| 86 | Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 0053 or approved equivalent) |
| 87 | Providing and fixing 15mm diameter C.P. brass stop cock with wall flange (Ref. Make: JAQUAR, Model: Cat. No. 0933 or approved equiva lent), male end with C.P. copper connecting pipe 375mm long or as required including nuts, washers, C.P. brass flange etc. including cutting & making good the walls wherever required complete in all respects inclusive of cost of all materials, labour, tools, tackl es etc. as per specifications and directions of the Engineer-in-Charge. |
| 88 | Providing & fixing Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 563 or approved equivalent) and Health Faucet with flexible tube 8mm diameter x 1.5 m long (Ref. Make: JAQUAR, Model: Cat. No. 549 or approved equivalent). |
| 89 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover (Ref. Make: SINTEX or approved equival ent), conforming to ISI:12701, colour of opaque white or as approved by the Engineer-in-Charge. The rate includes making necessary h oles for inlet, outlet & overflow pipes. The base support including fittings & fixtures for tank shall be paid separately. |
| 90 | Providing and laying non-pressure NP-2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in t he proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 91 | 300 mm dia. R.C.C. pipe |
| 92 | 450 mm dia. R.C.C. pipe |
| 93 | Construction of second class brick masonary open surface drain (Size: 200mm wide & 200mm average depth) in cement mortar 1:4 laid ov er a bed of 150mm thick cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including mak ing haunches and providing 15mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement inside and its top and exposed surfaces, including excavatioin, disposal of the surplus earth up to any lead and lift as per standard desi gn and drawing, complete in all respects inclusive of cost of all labour, materials, carriages, excavation and refilling, curing etc ., as per specifications and directions of the Engineer-in-Charge. |
| 94 | Constructing Brick Masonary catch pit in cement mortar 1:4 (1 cement : 4 coarse sand) including necessary excavation, 200mm thick fo undation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm size) and inside and top plastering (15mm thic k) with cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement making necessary connections to dr ains inclusive of all labour, material, equipment, etc., all complete as per drawing, specifications and directions of the Engineer -in-Charge : |
| 95 | 1000mm x 1000mm x depth up to 1200mm inner dimensions. |
| 96 | 750mm x 750mm x depth up to 1000mm inner dimensions |
| 97 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : |
| 98 | For fixed portion : |
| 99 | Powder coated aluminium (Minimum thickness of powder coating 50 micron) |
| 100 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittin gs wherever required including the cost of EPDM rubber/ neoprene gasket required. [Note: Fittings shall be paid for separately] : |
| 101 | Powder coated aluminium (Minimum thickness of powder coating 50 micron) |
| 102 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket et c. complete as per the architectural drawings and directions of the Engineer-in-Charge. [Note: Cost of aluminium snap beading shall be paid in basic item] : |
| 103 | With float glass panes of 5.50 mm thickness |
| 104 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per directions of the Engineer-in-Charge. : |
| 105 | With stainless steel cover plate minimum 1.25 mm thickness |
| 106 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per d irections of the Engineer-in-Charge : |
| 107 | Powder coated (Minimum thickness 50 micron) aluminium tubular handle bar |
| 108 | Providing and fixing brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for al uminium doors including necessary cutting and making good etc. complete. |
| 109 | Filling the gap in between Aluminium/ Stone/ Wood frame and adjacent RCC/ Brick/ Stone/ Wood/ Ceramic/ Gypsum work by providing weat her/ structural non-sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and directions of t he Engineer-in-Charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 : |
| 110 | Up to 5 mm depth and 5 mm width |
| 111 | Providing and fixing, on fixed glazing/ doors/ window panes, sun control film \\"HP NATURAL 35 SAFETY COMBINATION FILM-4Mil\\" of M/s. G ARWARE or approved equivalent make and shade, all complete as per manufacturer's specification and as per directions of the Engineer -in-Charge. |
| 112 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflec tivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric water proofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thi ckness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly c leaning the surface to remove loose particles with wire brushes, complete in all respect as per directions of the Engineer-in-Charge . |
| 113 | Supplying and using water proofing compound like CICO, PUDDLE or any other approved brand with Cement Plaster/ CC/ RCC complete in a ll respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the En gineer-in-Charge. |
| 114 | Providing and fixing 75mm diameter P.V.C. pipe (4 Kg/sq.cm) for Weep Holes in Masonry/ RCC wall including providing 230x230x230 mm s ize (approx.) filter using pebles of 40mm & down size in every weep hole on retaining side etc. complete in all respects inclusive o f cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge. |
| 115 | Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm down size) mixed with approved brand of water proofing compound @ 1Kg/50 Kg bag of cement, in roof grading, coping, in bed concrete etc. at all heights & depths, including providing centering and shuttering, scaffolding, watering, curing, vibrating, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer. |
| 116 | Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor fiv e level in : Cement mortar 1:4 |
| 117 | Preparation and consolidation of sub-grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the s ub grade and disposal of surplus earth with lead up to 50 metres. |
| 118 | Providing and laying design mix reinforced cement concrete of M-30 grade in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specifi ed design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading, levelling to required s lope/ camber and compacting mechanically by using screed board vibrators, vaccum dewatering process and finally finishing in require d texture by floating & brooming with wire brush, including steel form work with sturdy M.S. channel sections, curing, making provis ion for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing ex pansion joints as per drawing including dowel cap, sponge, sealing tape, bitumen painting, debonding tape and filling joints with ap proved joint filler and sealants, complete all as per direction of the Engineer-in-Charge. [Notes: (1) Item of joint fillers, sealan ts, dowel bars with sleeve/ tie bars to be paid separately. (2) The item rate is inclusive of cost of dowel cap, sponge, sealing tap e, bitumen painting, debonding tape. (3) Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design m ix is payable/ recoverable separately]. |
| 119 | Cement concrete prepared with batch mixing machine |
| 120 | Providing and fixing in position pre-moulded joint filler in expansion joints. [Note: Unit \\"CM\\" shall mean \\"PER CENTIMETRE DEPTH PER CENTIMETRE WIDTH PER METRE LENGTH\\"]. |
| 121 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. : |
| 122 | Using Grade 'A' sealing compound. [Note: Unit \\"CM\\" shall mean \\"PER CENTIMETRE DEPTH PER CENTIMETRE WIDTH PER METRE LENGTH\\"]. |
| 123 | Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS :164, on bituminous surface in white/ yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign mate rial etc. complete : |
| 124 | New work (Two or more coats) |
| 125 | Supplying and fixing Road Hump of minimum size 350 mm width x 50 mm thick made of Carbon Black mixed Rubber with Additive of LDPE fo r reinforcement & UV resistant colouring agent of black & yellow colour with 4 reflective glass beads, of weight not less than 16 Kg /metre, and capacity to withstand minimum 35 tonne weight (moving vehicle load) including cleaning the road surface of all dirt, sca les, oil, grease and foreign material etc. and fixing the hump on the Road top as per manufactures specifications with necessary fas teners complete in all respects inclusive of cost of all labour, materials, fasteners, tools, tackles etc. as per specification and directions of the Engineer-in-Charge. |
| 126 | Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thicknes s with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per s pecifications and directions of the Engineer-in-Charge : |
| 127 | With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 128 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thi ckness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc . as per directions of the Engineer-in-Charge. [Notes: (1) Length of finished kerb edging shall be measured for payment. (2) Precast C.C. kerb stones shall be approved by the Engineer-in-Charge.] |
| 129 | Providing and making Construction/ Contraction joint by mechanically cutting 12mm x 25mm deep groove and filling with bituminous sea ling compound including cleaning etc. complete as per drawing, specifications and directions of the Engineer-in-Charge. |
| 130 | Making plinth protection 50 mm thick of cement concrete 1:3:6 [1 cement : 3 coarse sand derived from natural sources : 6 graded ston e aggregate 20 mm nominal size derived from natural sources] over 75 mm thick bed of dry brick ballast 40 mm nominal size, well ramm ed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc . complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direc tions of the Engineer-in-Charge. |
| 131 | MPPL P25 - CSW Civil - IPIG 03 ITC |
| 132 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in widt h as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed b y the Engineer-in-Charge : |
| 133 | In all kinds of soil |
| 134 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 135 | 1:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from n atural sources] |
| 136 | 1:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from n atural sources] |
| 137 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 138 | Foundations, footings, bases of columns, etc. for mass concrete |
| 139 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level : |
| 140 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 141 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concr ete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement content as per approved design mi x, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, inc luding admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per directions of the Engineer-in-Charge. [Note : Cement content considered in this item is @ 3 30 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.] : |
| 142 | All works upto plinth level |
| 143 | Extra for providing richer mixes at all floor levels. [Note: Excess/ less cement over the specified cement content used is payable/ recoverable separately] : |
| 144 | Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. [Note: Cement content considered in M-30 is @ 340 Kg/cum] |
| 145 | Add for using extra cement in the items of design mix over and above the specified cement content therein. [Note: Unit \\"QN\\" shall me an \\"QUINTAL\\"] |
| 146 | Supplying and providing non-shrinkable cement grout (SHRINKKOMP 20 or any other equivalent approved brand) for grouting holding down bolts in pocket holes for equipment foundation, including necessary surface preparation mixing of grout, curing as per manufacturer 's recommendation/ specification and directions of the Engineer-in-Charge. [Note: This item shall be operated under specific instruc tions of the Engineer-in-Charge] |
| 147 | Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, cl addings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cut ting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. including pre paration of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying & applying painting with two coats of epoxy paint \\"EPILUX 155 High Build Enamel over a coat of \\"EPILUX 610\\" Primer of M/s BERGER or any other approved equivalent make as per manufacturer’s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of conc rete work). |
| 148 | Supplying and placing in position 5.0 mm thick steel chequered plates over cable ducts, valve pits etc. including provision for lift ing arrangements complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifica tions and directions of the Engineer-in-Charge. |
| 149 | Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 la id to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labo ur, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. |
| 150 | 15 mm cement plaster 1:2 (1 cement : 2 stone dust) on the rough side of single or half brick wall. |
| 151 | 6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand) |
| 152 | Electrical Supply |
| 153 | SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges: RUBBER HAND GLOVES: Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark. |
| 154 | INSULATING MATS - Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elasto mer mats as per specifications: Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2.5 mm (Class B) |
| 155 | SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges: Supply of fully charged CO2 fire extinguishers as per specifications (4.5 kg capacity as per IS: 2878 latest) |
| 156 | SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges: Supply of fire buckets mounted on stand |
| 157 | Electrical Service |
| 158 | Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and materials comple te as per drawings, specification and directions of Site Engineer / Engineer-in-Charge |
| 159 | WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to origina l condition and disposing off excess materials (within the work site) job complete in all respects including the cost of labou r, tools, materials, load, lift hire charges of equipments, if any, complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. |
| 160 | Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cabl e racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and inst allation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all la bour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions o f Site Engineer / Engineer-in-Charge: |
| 161 | Power cables LT : OD upto 20 mm |
| 162 | Power cables LT : OD above 20 mm and upto 40 mm |
| 163 | Control cables (T&I) : OD upto 20 mm |
| 164 | Silent LT DG set - Erection, Installation including transportation from owner desginated location, connecting, testing and commissio ning of owner/vendor supplied Emergency LT DG set including execution of terminal connection of power/control cable. The work shall include grounding of alternator neutral, earthing, providing water pipe connection for Radiator water make-up complete with valve, s olenoid valve etc. piping for fuel line, fabrication, welding, erection and painting of support structure for exhaust piping, mounti ng on channels/AVM pads, installation of PLC based AMF panel, NIG panel, exhaust piping including insulation and cladding, fuel pipi ng etc., materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: LT DG set with PLC based AMF panel, fuel tank etc |
| 165 | 415 V AC 3 phase / 230 V AC single phase motors - Connection and testing of 415 V AC 3 phase / 230 V AC single phase motors (includi ng space heaters/thermistors wherever provided) / AC/DC Actuators including execution of terminal connection of control and power ca bles, earthing of the motor/actuator/ connecting the thermistor, installing the controller in LT panel, earthing the motor frame, ar mour etc. as per the drawings, erection manuals, and as per directions of Site Engineer. Job complete in all respects including the cost of supplying and installation of all the required FLP/WP cable glands, reducers, adapeters, end lugs, GI earthing wire / strips , labour, tools, materials, etc., as required in all respects for all types of motors/heaters/thermistors/actuators etc.: |
| 166 | Capacity above 1 KW and upto 2.5 KW |
| 167 | Capacity above 2.5 KW but upto 7.5 KW |
| 168 | Capacity above 7.5 KW but upto 50 KW |
| 169 | LT Panel - Erection, installation including transportation from owner desginated location, testing and commissioning of 415 V, owne r supplied power-control- centres, motor control centres, soft starters, APFC panel etc. assembling as required, installation on the already made foundation channels, aligning, levelling, grouting, assembling, making all the inter connections /outgoing/incoming po wer & control cable/ bus duct connection including making holes for cable entries as required as per drawing, specifications and dir ections of the Site Engineer/Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect including termination of all power, control cables, installation of thermistor controller, internal wiring, earthing of LT panels, supply of cable glands etc.complete as per cable schedule, drawings etc.: Weight of unit above 1000 kg but upto and including 3000 kg |
| 170 | Installation of corrosion monitoring probes including 2\\" Flareweld on station piping at desired location and 12 O'Clock position for mounting of ER Probe under the supervision of site engineer. Flareweld assembly shall be supplied by owner. The job complete in all respect with material, tools & tackles, consumables etc. |
| 171 | Electrical Composite |
| 172 | Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg /Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. |
| 173 | Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, loa d and lift charges, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge |
| 174 | Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable tren ches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , as per drawing s, specification and directions of Site Engineer / Engineer-in-Charge. |
| 175 | Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, ba ckfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. |
| 176 | EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the eart hing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer -in-charge, including the cost of all labour, tools, materials, etc. complete in all respect: |
| 177 | 50 mm X 6 mm G.I. earthing strip |
| 178 | 40 mm X 5 mm G.I. earthing strip |
| 179 | GI wire /rope (8 SWG) |
| 180 | GI wire / rope 10 mm diameter |
| 181 | Copper cable as per specifications - 100 Sq.mm |
| 182 | Copper cable as per specifications - 10 Sq.mm |
| 183 | Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (a lready made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of s ite engineer / Engineer-in-Charge: |
| 184 | 25 mm |
| 185 | 37 mm |
| 186 | 50 mm |
| 187 | 100 mm |
| 188 | Supply, fabrication, erection, installation of steel structural works of any type and shape such as cable raks, cable trays, push bu tton control posts etc., as required job complete in all respects including the cost of all labour, tools, material etc., complete. and as per specifications and directions of site engineer/ Engineer-in-Charge. |
| 189 | FLAME PROOF FITTINGS - All equipment under this category shall be suitable (minimum requirments) for location in zone-I gas group II A & IIB (Temp. class T3) area with a separate terminal box for incoming cable and a separate terminal box for out going cable (where applicable), apart from separate enclosure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified en closure: FLAMEPROOF TUBELIGHT, 2x22Watt, LED, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007 |
| 190 | FLP/WP PUSH BUTTON STATION - Supply ,erection,testing and commissioning of FLP/WP push button(ON/OFF) control station of approved m ake with /without ammeter for the motor off control at field including connection and termination of copper control cable, fabricati ng, earthing the supporting structure, painting the same, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries including the cost of all labour,tools, materials etc. complete in every respect as per t he specification and directions of the Site Engineer/Engineer-in-charge including the cost of all labour,tools, materials etc. compl ete in every respect as per the specification and directions of the Site Engineer/Engineer-in-charge: With Ammeter |
| 191 | FLP & WP JUNCTION BOX - Supply, erection, installation, testing and commissioning of flameproof & weather proof junction box for pr oviding cable termination of motor, including connection and termination of earthing wire and conduits etc., including supply & inst allation of double compression cable glands & flame proof plugs for sealing all spare entries complete as per drawings, specificatio ns and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc., complete in all respect: 4 way junction box with 4 cable entries (4 x 3/4\\") at bottom & 20 nos. terminals. |
| 192 | Flame proof, weather proof, single phase, 12\\" exhaust fan, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007, IP65, LM6 type EF1001 of FCG or equivalent alongwith supporting frame, bolts, louvers, flame proof motor, including supply & installation of doubl e compression cable glands & flame proof plugs for sealing all spare entries, complete in all respects |
| 193 | Supply, installation, testing & commissioning of Flame proof weather proof ON/OFF Rotary Switch , IP65, LM6, including including sup ply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., complete in all respec ts. |
| 194 | FLP/WP DISTRIBUTION BOARDS - Supply, erection, installation, testing and commissioning of flameproof /weather proof (IP-65) distrib ution board as per technical specification of types mentioned for lighting purpose in MLPU / booster shed etc., including connection and termination of power cables, earthing wire and conduits etc. including including supply & installation of double compression ca ble glands & flame proof plugs for sealing all spare entriescomplete as per drawings, specifications and direction of the Site Engin eer, including the cost of all labour, tools, consumable materials etc. complete in all respect: Outdoor Type, floor mounted, flame proof, weatherproof (IP 65) Lighting Distribution board Type-II DB having Bus bar - 100 A TPN, Incomer - 1 no. 32 A TPN MCB & Outgo ing - 3 no. 6 A SPN MCB |
| 195 | FLP/WP SWITCH CUM SOCKET - Supply, erection, installation, testing and commissioning of flameproof /weatherproof switch cum socket /welding receptacle of approved makes to be installed on walls, coloumns, structures, including supply & installation of double comp ression cable glands & flame proof plugs for sealing all spare entries etc., including connection and termination of earthing wire a nd conduits., etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, to ols, consumable materials etc. complete in all respect: 415V, 63A, Switch & Socket with Plug (No. of Pins 3P +N+ E), Model EPSS 156 3-61 of Baliga or Equivalent approved make |
| 196 | Supply, erection, testing and commissioning of Weather Proof push button (OFF) control station of approved make for emergency trans former tripping at field including connection and termination of copper control cable, fabricating, earthing the supporting structur e, painting the same, including supply & installation of cable glands & plugs for sealing all spare entries including the cost of a ll labour,tools, materials etc. complete in every respect as per the specification and directions of the Engineer-in-charge. |
| 197 | Supply and installation of shock treatment chart framed in good quality glass in English / Hindi / Local Language. |
| 198 | Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/6.6 KV as per IS 255 including fixing on the wall with all the required hardware etc. complete in English / Hindi/ Local Language. |
| 199 | Supply and installation of approved quality stainless steel name inscription plates including anodising, engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, provi ding necessary holes tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-char ge including the cost of all labour, tools etc. |
| 200 | \\"Supply and installation of approved quality plastic name inscription plates including engraving the inscriptions, providing screws , etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, providing necessary ho les tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-charge including the cost of all labour, tools etc.\\" |
| 201 | Point wiring - Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installa tion of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes ,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor: |
| 202 | 1 light point controlled by 1 switch |
| 203 | 2 light points controlled by 1 switch |
| 204 | Ceiling fan wiring: Wiring with PVC insulated 2.5 sqmm copper conductor wire for fan points (1 fan point controlled by 1 modular sw itch) including providing space for electronic regulator in switch box, providing and fixing fan hook in the ceiling as per specific ations and drawings. |
| 205 | Exhaust fan / wall bracket fan wiring: Wiring with PVC insulated 2.5 sqmm copper conductor wire for phase & neutral , 650 V grade i ncluding earthing , the third pin with 1.5 sqmm copper conductor earthing insulated continuity wire for exhaust/ wall bracket fan in cluding providing and fixing of 5 pin 6 A modular socket and 10 A modular switch near the door or as as per specifications and drawi ngs. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st exhaust fan for multiple exhaust fans in one circuit. |
| 206 | 16 A power plug point wiring: Wiring for 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm copper conductor earth ing insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socket and 20/10 A modular switch (1 plug p oint per circuit) as per specifications and drawings |
| 207 | 6 A plug point wiring: Wiring for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper co nductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 5 pin 6A modular socket and 10 A modular switch (1 plug point per circuit) a s per specifications and drawings. |
| 208 | Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribu tion board of approved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conf orm to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings: Critical Light DB: Euro DB DBOXx of Havells or equivalent make complete with bus bar, neutral links, earth links and 1 x 6 A MCB SPN & 7x2 A SPN MCB |
| 209 | Decorative Light fittings - Supply, installation, connection, earthing and testing of the following fittings, including supply and i nstallation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other requir ed materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from t he approved make list given in the specifications: |
| 210 | Supply and fixing of LED wall light cat. no. 35022 9W fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation. |
| 211 | LED light fittings with LEDs, Sereno LED-Suspended-SP824 P LED 30S-5000 GR OD or approved equivalent:Supply and fixing of surface mo unted weather proof light SP824 P LED 42 W having 2950 lumens output fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved m ake. |
| 212 | Critical Light: Non Flame Proof type PEL 240 M/SL of Prolite or of approved make as per EIC, with 2 X 18 W LED TL/ Lamp including se aled lead acid battery of suitable size for minimum 01 hour back up, battery charger, for Fire fighting pump shed, HT/LT Room, Batte ry Room etc.The job includes connection of the fitting, 6A switch socket with 2C x 4 sqmm cable from DB/switch board and as mentione d above including all accessories etc. complete in all respect as per direction of EIC / Site engineer. |
| 213 | Swan neck lighting pole with LED well glass light: |
| 214 | Supply, installation, testing and commissioning of swan neck lighting pole of 100mm nominal Diameter B class MS pipe (Height of bot tom of light fitting shall be 5 meters from FGL), having base Plate 200mmx200mmx5mm along with Flameproof and Weatherproof 2x18W LE D well glass light fitting complete with lamp and builtin control gear and choke of approved make, including supply and installation of earthing conductor of 8 SWG GI wire, nuts, bolts, Neck portion of lighting pole shall made up be of 50mm diameter GI pipe (radiu s of neck shall be 250mm). The pole shall be painted with 01 coat of primer and 02 coats of aluminium paint. The job shall also incl ude supply and installation of 4 way Flameproof/weather proof junction box (with 4 cable entries) having 8 Nos., 6A, 440V shrouded t erminal, with double compression FLP glands/lugs with looping arrangement and supply and termination of 3C X 2.5 sq. mm. armoured co pper PVC/XLPE insulated cable from JB to light fitting The job complete in all respects as per specifications, drawings and instruct ions of EIC / Site engineer. |
| 215 | Supply, installation, testing and commissioning of swan neck lighting pole of 100mm nominal Diameter B class MS pipe (Height of bott om of light fitting shall be 2 meters from FGL), having base Plate 200mmx200mmx5mm along with Flameproof (Exd IIA/IIB) and Weatherpr oof 1x60W LED well glass light fitting complete with lamp and builtin control gear of approved make, including supply and installati on of earthing conductor of 8 SWG GI wire, nuts, bolts, Neck portion of lighting pole shall made up be of 50mm diameter GI pipe(radi us of neck shall be 250mm). The pole shall be painted with 01 coat of primer and 02 coats of aluminium paint. The job shall also inc lude supply and installation of 4 way Flameproof/weather proof junction box(with 4 cable entries) having minimum 4 Nos., 6A, 440V sh rouded terminal, with double compression FLP glands/lugs with looping arrangement and supply and termination of 3C X 2.5 sq. mm. arm oured copper PVC/XLPE insulated cable from JB to light fitting The job complete in all respects as per specifications, drawings and instructions of EIC / Site engineer. |
| 216 | Ceiling fan, BEE 5 star rated, with electronic regulator & other accessories and fittings etc. of or approved make with 56\\" Sweep s ize |
| 217 | Exhaust fan - Supply, installation, testing of single phase 230 V, industrial type heavy duty exhaust fan of GEC/Usha/Crompton Greav es or of approved make fitted/ provided with louvres, supports etc. including making the required opening on walls, fixing and conne cting the wires etc. including earthing the body of the fan, making good the opening on the wall etc. complete as per specifications , drawings and direction of Site Engineer including the cost of all labour, tools, materials etc. complete. |
| 218 | 18\\" Sweep |
| 219 | 12\\" Sweep |
| 220 | PVC Conduit pipes - Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providi ng necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including makin g good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge includin g cost of all labour, materials etc.: |
| 221 | 19 mm |
| 222 | 25 mm |
| 223 | 32 mm |
| 224 | Supplying and laying reinforced cement concrete light duty hume pipe, non pressure type (NP3), centrifugally cast conforming to I.S .458 with 1:3:6 concrete casing at joints as required with necessary slope including excavation, backfilling, supply of collars, jo inting of pipes with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand), testing of joints, complete i n all respects as per specifications, drawing and the direction of the EIC/Site Engineer: |
| 225 | 300 mm dia |
| 226 | Supply fixing and erection of modular cable transit (MCT) for cable entry to building in proper frame including supply of peelable t ype, spare block, stay plates compression wedgs etc. with all accessories as per specification considering 20 % minimum spare in eac h module to be installed as per instruction of Engineer in charge/ site engineer: |
| 227 | Galvanised mild steel frame with packing space of Min.120x240 mm with multi diameter blocks and accessories with peeling off arrange ment to adjust cable size from 3.5mm to 99mm outer dia |
| 228 | Galvanised mild steel frame with packing space of Min.120x180 mm with multi diameter blocks and accessories with peeling off arrange ment to adjust cable size from 3.5mm to 99mm outer dia |
| 229 | Lightining Arrestor: Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverti ng lightning surges to the ground. The work shall include supply of 1.2 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. complete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the main earthing grid. |
| 230 | INST_IPIG3_SERVICE |
| 231 | Installation of Wall mounted Cabinet (switching closet) for housing Networking Equipment/ CCTV hardware, patch panel & accessories including power distribution boxes, MCBs/ Isolator Switches, required installation materials as per tender specifications |
| 232 | As built documentation for each station covering a) Control /signalling cable layout drawings, b) Cable trench details, c) Cable marker details, d) Earth grid layout, e) Field instrument termination details, f) Cable schedule, g) Junction box wiring details, h) Earth resistivity measurement data, i) Field panel termination details, j) Calibration data of all instruments tested as per scope., k) OTDR Traces of the laid OFC as applicable for respective stations |
| 233 | Installation of wall mounted Fibre Termination Box (FMS) as per tender specifications and directions of Engineer-in-charge/ Site Engineer |
| 234 | INST_IPIG3_COMPOSITE |
| 235 | Taking delivery, shifting within a road distance of 500 meters and installation & testing of the following instruments (pressure Gauge, Pressure Switch, Pressure Transmitter, flow meters, density meters etc. of various ratings by fabrication and installing all the required pipe fittings with pressure pipes, valves, plugs, tees, nipples, junction box, cables, supply and erection of all other required materials such as the supporting structure clamps, cannopy, screws, nuts, bolts, aluminium sheets, GI wire, steel plats, cement concrete etc. complete in all respects including supply of suitable size non flame proof cable gland at control panel end and terminating the already laid cables at field, junction box and control panel end, mounting the junction boxes as per the Drawings, specifications and directions of the engineer in-charge/site engineer including cost of all labour, materials, consumables, tools, tackles and services rendered etc. All the instruments shall have to be properly connected to the earth pit through GI wires. The works shall include labelling, tagging using SS plates, glanding and ferruling at both field and panel side. Installation to be done as per OEMs recommendations, vendor drawings and other approved drawings. The scope shall include providing assistance in testing and commissioning of the instruments along with loop checking and providing assistance to control system vendor |
| 236 | INSTALLATION OF PI/ PT / PS: Installation, assistance in testing and commissioning of Pressure Indicator (PI)/ Pressure Transmitter (PT) including remote seal type PT/ Pressure Switch (PS) of various ratings as per the directions of Engineer in-charge/ Site engineer and drawings. |
| 237 | INSTALLATION OF DPT: Installation, assistance in testing and commissioning of Differential Pressure Transmitter (DPT) as per the directions of Engineer in-charge/ Site engineer and drawings. |
| 238 | INSTALLATION OF TEMPERATURE TRANSMITTER WITH THERMOWELL: Installation and assistance in testing & commissioning of thermowell, temperature elements & temperature transmitter(TT) by making necessary holes on the pipes, welding the socket for thermowell on the pipe including supply of boss, silicon paste etc as per the directions of engineer in-charge/site engineer and drawings. |
| 239 | INSTALLATION OF SUB SOIL TEMPERATURE TRANSMITTER Installation and assistance in testing & commissioning of sub soil temperature elements/temperature transmitter (TT) by as per the directions of engineer in-charge/site engineer and drawings. |
| 240 | INSTALLATION OF SURFACE MOUNTED TEMPERATURE TRANSMITTER Installation and assistance in testing & commissioning of Surface Mounted temperature elements/temperature transmitter (TT) by by welding the weld pad on the surface of the pipe, silicon paste as per the directions of engineer in-charge/site engineer and drawings. |
| 241 | INSTALLATION OF EMERGENCY SHUTDOWN SWITCH: Installation and testing of emergency shut - down (ESD) Push button. This includes mounting of termination box as per the drawings, specification and instruction of Engineer in-charge/ Site engineer, replacement of broken glass covers and painting it in red colour. |
| 242 | INSTALLATION OF FLOW SWITCH: Installation and testing of Flow switch. This includes mounting of termination box as per the drawings, specification and instruction of Engineer in-charge/ Site Engineer. |
| 243 | INSTALLATION OF LEVEL TRANSMITTER: Installation and testing of Level Transmitter (of all types i.e contact type / non contact type etc.). The scope shall include installation, assistance in testing and commissioning of Level Transmitter (LT) on sump tank / crude oil fuel tank / fire water tank / surge relief tank / ransmix tanks/ Crude Oil Tank etc. as per the OEM recommendations, vendor drawings, directions of engineer in-charge/site engineer and other apporved drawings. in -charge/ Site Engineer. |
| 244 | INSTALLATION OF LEVEL SWITCH: Installation, assistance in testing and commissioning of Level Switch of various lengths as per drawings, specifications and the directions of Engineer in-charge/ Site engineer. The scope shall include installation, assistance in testing and commissioning of Level Switch (LS) on sump tank / fuel tank/ surge relief tank / transmix tanks etc. as per the OEM recommendations, vendor drawings, directions of engineer in-charge/site engineer and other apporved drawings. |
| 245 | DENSITY INDICATOR INSTALLATION - Taking delivery and shifting to site within distance of 500 m, installation and testing of Density Indicator, including fabrication and erection of all installation structure such as mounting stand, canopy etc, termination of cables at both ends after loop testing as per the drawings and directions of site engineer. |
| 246 | DENSITY METER/VISCOSITY METER INSTALLATION - Taking delivery, shifting to installation site within the station premises, erection, installation of Density transducer (DE/DM) complete with by pass scoop, pitot tube, weld neck flanges. Providing assistance to control system vendor/density meter supplier in testing and commissioning of density meter. Installation and erection shall be as per manufacturer's instructions, drawings and engineer in-charge/site engineer's instructions. Job shall include termination of cables both at control panel end and density transducer end, welding of weldolet, supply of suitable size non-flame proof cable glands, steel structures or fixtures, leveling, grouting, assembling and fixing all accessories, labelling, tagging using SS plates, glanding, ferruling etc complete in all respect. |
| 247 | FLOW METER INSTALLATION - Taking delivery, shifting to installation site within the station premises, erecting and installing of the flow meter along with reducers and flow meter electronics/ flow transmitter. Providing assistance to control system vendor/meter supplier in testing and commissioning of the turbine/ ultrasonic / coriolis mass flow meter / clamp on ultrasonic ete etc.. Making structural supports and fittings, clamps, screws, nuts, bolts, making the cable supports and terminating cables at panel and field ends. Mounting the junction boxes as per drawings,manufacturer's instructions, specification and direction/instruction of engineer in-charge/site engineer. Job shall include termination of cables at both fiels ends and control panel ends, supply of suitable size non-flame proof cable glands at control panel and the cost of all labour, tools, materials, etc. including labelling, tagging using SS plates painting, glanding, ferruling complete in all respect. |
| 248 | INSTRUMENTATION JOBS FOR PRESSURE CONTROL VALVE / FLOW CONTROL VALVE - Testing of control valve and field electronics, including fabrication of all structural supports and fittings, termination of related cables at field, panel & MCC end, after loop testing as pervendors drawing and direction of the site engineer. Mounting of junction box if any, supply of non flame proof cable glands for paneland MCC end. The works includes tagging, labelling, glanding andferruling at both panel and field ends. |
| 249 | INSTALLATION OF JUNCTION BOX/ PUSH BUTTON STATION - for MOV/ROSOV: Installation of non-flame proof junction box, explosion proof / flame proof junction boxes, Push button stations for MOV/ROSOV for marshalling of control cables, terminating the cables at field and control panel end, mounting the junction boxes/Push button station, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, canopy, cable gland hood, cement concrete, painting, GI wire etc. (excluding supply of the Junction Boxes/Push button station) in all respects complete as per specifications, drawings and direction of site Engineer including supply of suitable size non-flame proof cable glands at Control Panel end and the cost of labour ,tools, materials, glanding, ferruling etc. complete in all respects. |
| 250 | INSTRUMENTATION JOBS FOR MOTOR OPERATED VALVES (MOV)/ROSOV/ROV - Carrying out the instrumentation and control system jobs on the already erected actuator assembly of motor operated valves (MOV)by making the necessary cable connection at field and control panel end (excluding the supply of cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc. |
| 251 | Installation of Infrared HYDROCARBON DETECTORS (point type / open pathtype), terminating the cables at field and control panel / RTU end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, canopy, cement concrete, painting, GI wire etc.(excluding supply of the Hydrocarbon detector) complete in all respectsas per specifications. |
| 252 | Installation of Manual Call Point (Explosion Proof & Weather Proof) in Hazardous area, terminating the cables at field and control panel end, connecting to earthing grid by supplying and installing all the required materialssuch as supporting structure, cement concrete, painting, GI wire etc.(excluding supply of the Manual Call Point) complete in all respectsas per specifications. |
| 253 | INSTALLATION OF CONTROL PANEL/CONSOLE DESK/ UPS/ RIO/ RTU/ PLC/ ACDB - Taking delivery, shifting the panels to installaion site and erection, installation, testing of Control panels, mounted with all the instruments, power supply units, UPS & battery banks logic control systems , barriers, providing assistance to control system vendor for commissioning of control system including panels, control/console desk etc. installation on already made foundations or fixing on walls, or steel structure or fixtures aligning, levelling, grouting, inter-wiring outgoing, incoming cable terminations as required, earthing, testing, complete in all respects as per drawings, specifications and directions of the engineer in-charge/site engineer, including supply of suitable size non-flame proof cable glands for all incoming/outgoing cables and the cost of the materials, tools, labour, glanding, ferruling etc. complete in all respects.The indicated quantity is cumulative weight of panels. |
| 254 | STEEL STRUCTURAL WORKS - Supply, fabrication, erection and installation of steel/GI structural works of any type and shape such as cable racks, trays, push button, control posts, ladders, lugs, chain link, fencing, angles, joints, channels, plates, flats, bars etc as required as per specifications, drawings, directions of site engineer/engineer in-charge, inlcuding cost of all labour, materials, tools, consumables etc complete in all respects. Job is inclusuve of taking delivery from owner's go down and shifting to site wherever required. |
| 255 | DISMATLING OF CONTROL PANEL / MIMIC PANEL/ CONSOLE DESK/UPS/RTU: Dismantling of Control panels / MIMIC panels/UPS/RTU etc, retrieving cards/ modules in good condition and storage as per direction of site engineer/EIC, retrieving cables from control panels in healthy condition, isolating the retreived cables, labelling, of the cables etc so as to complete the job in every respect as per directions of site engineer / EIC |
| 256 | Supply and installation of IDF (intermediate distribution frame) / Distribution box of 20 Pair capacity with mounting arrangement as per specifications |
| 257 | Supply and installation of MDF (Main distribution frame) /Distribution box of 50 Pair capacity with mounting arrangement as per specifications |
| 258 | Supply & installation of MAGNETIC PROXIMITY SWITCH with suitable junction box for termination of leads/cable for extending contact to control system for unauthorised entry of building / MOV fencing. |
| 259 | Laying of HDPE conduit and blowing of OFC cable inside the SV/MOV premises along the boundary wall, line item includes supply & installation of suitable clamps , connectors, fixture, corner bends, tools & tackles (comprising of anchor bolts/nuts/accessories etc) required for OFC entry inside SV/MOV loctaionalong the boundary wall by clamping of HDPE conduit at a height of 1 meter above the finished ground level and extending it along the length of boundary wall at 1 meter height upto the transition pit inside SV/RCP building as per attached drawing no. STD-793-00. The line item includes all sevices required for blowing of OFC cable iin HDPE conduit inside the MOV/SV loctaion as per STD - 793 drawing. |
| 260 | INST_IPIG3_SUPPLY |
| 261 | Supply of Pressure Indicators (PI) of the range 0 to 10 Kg / Cm2 as per the technical specifications attached in the Tender. |
| 262 | Supply of Pressure Indicators (PI) of the range 0 to 40 Kg / Cm2 as per the technical specifications attached in the Tender. |
| 263 | Supply of Pressure Indicators (PI) of the range 0 to 100 Kg / Cm2 as per the technical specifications attached in the Tender. |
| 264 | Supply of flame proof and weather proof fittings including EP/WP certificates as per the technical specifications attached. |
| 265 | FLP/ WP Junction Box, Type C. (Nos. of terminals: 60 Nos.; Bottom entry: 1 No. - 1 1/4\\" & 1 No.- 1\\"; Left side entry: 1 No. - 1\\" & 3 Nos.- 1/2\\"; Right side entry: 2 No. - 1\\" & 2 Nos.- 1/2\\") along with FLP cable glands & FLP plugs for all the cable entries of the Junction as per technical specifications. |
| 266 | FLP/ WP Junction Box, Type D. (Nos. of terminals: 24 Nos.; Bottom entry: 1 No. - 1\\"; Left side entry: 3 Nos.- 1/2\\"; Right side entry: 3 Nos.- 1/2\\") along with FLP cable glands & FLP plugs for all the cable entries of the Junction as per technical specifications. |
| 267 | FLP/ WP Emergency Shut Down Push Button Switch (with 2 nos. cable entry provision of 1/2\\" NPT) with steel hammer chained with main unit. |
| 268 | Supply of additional Cable Glands - flame proof and weather proof including EP/WP certificates: |
| 269 | 1 1/4\\" (5/4\\") |
| 270 | Supply of additional Plugs - flame proof and weather proof including EP/WP certificates: |
| 271 | Supply of Reducers - flame proof and weather proof including EP/WP certificates: |
| 272 | 1\\" to 1/2\\" Reducers |
| 273 | 1\\" to 3/4\\" Reducers |
| 274 | 3/4\\" to 1/2\\" Reducers |
| 275 | Supply and placing in position 5 mm thick steel checkered plates over cable ducts, valves, pits etc including keeping provision of holes for lifting arrangement and providing lifting arrangement complete in all respect inclusive of cost of all labour, material, carriage etc as per specification & the direction of the engineer in-charge/site engineer |
| 276 | 2 Pair unarmoured Telephone Cable as per specifications |
| 277 | 20 Pair Armoured PIJF Underground Telephone Cable as per specifications |
| 278 | Cat 6 UTP (LAN) Networking Cable as per tender specifications |
| 279 | Wall mounted telephone socket outlet with 2 port telephone jack face plate (white/ cream colour) including RJ11 I/O. The item includes modular plate & switch box/ gang box for fixing the face plate. |
| 280 | Duplex (2 port) Face plate (Network I/O point) (white/ cream colour) for Local Area Network including RJ45 I/O, modular plate & switch box/ gang box for fixing the face plate. |
| 281 | Wall mounted Cabinet (switching closet) for housing Networking Equipment/ CCTV hardware, patch panel & accessories including power distribution boxes, MCBs/ Isolator Switches, required installation materials as per tender specifications |
| 282 | 8 port Industrial Grade Network Switch with Optical Interfaces as per tender specifications |
| 283 | 24 port Industrial Grade Network Switch with Optical Interfaces as per tender specifications |
| 284 | Power cable 3 core x 2.5 mm2 Armoured, Copper as per tender specifications |
| 285 | 600 VA UPS with battery back-up for LAN switch |
| 286 | 19/25 mm ISI marked GI conduit along with all fittings & fixtures like Tees, bends, junction boxes, etc for installation of detectors in buildings |
| 287 | 2 Pair x 1.5 Sq. mm, unarmoured FRLS cable complaint to BS: EN 50288-7 as per the tender specifications for indoor applications to be laid through PVC/Metaliic conduits. |
| 288 | Supply of wall mounted Fibre Termination Box (FMS) as per tender specifications |
| 289 | 12 Fibre Single Mode Armoured Optical Fibre Cable as per Technical Specifications SAP material code: 9320712494 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
| 10 | Click here to download tender document | Tender Documents |
| 11 | Click here to download tender document | Tender Documents |
| 12 | Click here to download tender document | Tender Documents |
| 13 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail