Tender For Supply Installation Testing and Commissioning of Uninterruptible Power Supply (Ups) System Work In New / Old Building , At Rajasthan High Court,Jaipur.
Name of Work:- SITC Of Uninterruptible power supply (UPS) System Work in New / old building , at Rajasthan High Court,Jaipur.
Sl. No.
Item Description
1
SITC of 3Phase Input, 3Phase Output Online double conversion VFI-SS-111 IGBT based Rectifier & Inverter UPS with 0.99 Input power factor & unity Output factor(KVA=KW), having Inbuilt Isolation Transformer at Input, Phase balance of 120° ±1° (100% unbalanced load), input voltage & frequency range of 320-480V & 45-55 Hz and output voltage of 415V (+/- 1% for balanced & +/- 2% for unbalanced load) & output frequency of 50Hz +/- 0.1 Hz.UPS should have Inbuilt phase sequence corrector & protector both (UPS should correct the Input Phase reversal condition & shall not go to battery mode) and Input, output & Bypass breaker, UPS should have Inbuilt Static & maintenance bypass, Parallel kit, EPO, dust filter & conformal coated boards, Overall efficiency without transformer loss (93% for 10KVA, 94% for 20KVA & 30KVA, 95% for 40KVA& 60KVA) , Overloading on mains mode = 110% for 60 mins, = 125% for 10 mins, =150% for 1 min, THDi < 4%. UPS should have LED Panel with minimum 5 inch Intuitive Touch Screen LCD Displayy showing UPS status with other parameters like Input, Output, Bypass - Voltage/ Frequency,load%, Battery%. UPS should have protection from Input High / Low; Over Load;Short Circuit; Over Temperature and give audible alarms on Battery Mode;Low Battery;Fault;Over Load & Bypass Mode.UPS communication through RS485. SMF Batteries of 12V VRLA for 30 min back up with MS Rack having battery breaker with enclosure and necessary cable for UPS to Batteries Installation of 20 Mtrs.UPS should have feature to connect similer model & capacity with common battery bank.Operating Temperature of UPS 40 degree, relative humidity 0-95% (Non condensing), Noise level of 65dBA @1 mtr. UPS should have CE, ROHS, IEC62040-1,2&3 compliance and should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. as required.
2
10KVA UPS with 10080 VAH Battery
3
20KVA UPS with 20160 VAH Battery
4