Tender For Supply, Installation, Testing And Commissioning Of Heating, Ventilation And Air Conditioning System For Lecture Halls At Workshop Block Of Gcet Chak Bhalwal Jammu.
Tender Overview
Project Description
Tender for Supply, Installation, Testing And Commissioning Of Heating, Ventilation And Air Conditioning System For Lecture Halls At Workshop Block Of Gcet Chak Bhalwal Jammu.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Jun-2026 | Extension of dates | Date | 06-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of Variable refrigerant flow/variable refrigerant volume air cooled top discharge outdoor units suitable for cooling and heating complete with hermetically sealed inverter-driven compressor(s), microprocessor-based control system, with factory-charged refrigerant R-410A refrigerant. The unit shall deliver the rated capacity at AHRI conditions and work at high ambient temperature upto 55 degree with COP greater than 3.5. The unit shall be suitable to work on 400V+/-5%, 3phase 50Hz AC power supply. The unit shall have weatherproof casing, anti-corrosion treated condenser coil, all factory-fitted safety and control devices, vibration isolation arrangement, necessary mounting accessories, interconnecting control terminals, testing, commissioning and satisfactory operation as per manufacturer's specifications. Capacity- 14 HP |
| 2 | Supply, installation, testing and commissioning of 4-Way Ceiling Cassette Type Variable refrigerant flow Indoor, complete with decorative/LED panel, DC fan motor, electronic expansion valve (EEV), condensate drain pump, washable air filter, return air grille, discharge louvers, infrared wireless remote controller/wired controller, mounting accessories, control wiring terminals and all factory-fitted components required for satisfactory operation, complete as per manufacturer's specifications. Capacity 4 TR |
| 3 | Providing and fitting of refrigerant copper pipe of different diameter as per manufacturing design complete with elbows, bends, reducers, fittings, brazing, supports, hangers, sleeves etc. This shall also includes complete insulation of copper pipe with class-0 closed cell elastomeric nitrile rubber insulation of minimum 19 mm thickness. Complete with all accessories as required for complete installation. |
| 4 | Commissioning of air conditioning system including topping with R410A as per site requirement and OEM standards. |
| 5 | Providing and fitting of 40mm rigid UPVC drain pipe complete with all sorts of fitting, supports etc. |
| 6 | Supply, installation, testing and commissioning of Y-joint. |
| 7 | Design, manufacture, fabrication, installation, testing & commissioning of main LT distribution panel outdoor type with canopy suitable for operation on 415V, 3 PH, 50 Hz for 01 no. incoming and 03 nos. outgoing supply for ODU and 12 nos. outgoing supply for IDU. The panel shall be indoor type supported on M.S angle of suitable size and provision for fixing it on the ground with the help of foundation bolt, sheet metal enclosed with lockable type hinged doors, cubicle type, dust & vermin proof, fully compartmentalized made out of 16 SWG CRCA sheet steel and given two coats of anti rust primer and two coats of steel grey enamel paint complete with aluminum busbar, necessary wiring, cable glands etc Incomer1. MCCB’s of Suitable rating2. Aluminum 4 Pole Bus Bar-3. Digital Voltmeter with Selector Switches 4. Digital Ammeter with Selector Switches & CT’s 5. 5. Phase Indicator Set -6. OutgoingMCB’s/TPN and contactors of suitable rating as per OEM. It shall have overload relays, timer with built-in thermal-magnetic over current, short circuit & equipped with digital ammeter, CTs, selector switch & ON/OFF indicating light & control fuses. Complete in all respect for successes full commissioning of air conditioning system. |
| 8 | Earthing with copper earth plate 600 x 600 x 6mm thick by digging of pit having dimension 0.6 x 0.6 x 3.0 mtrs including all accessorties and masonry enclosure with cover plate having locking arrangement and water piping 2.7 meter long etc with charcoal/coke and salt as required. |
| 9 | Providing and laying of GI strip of size 25 x 6mm as strip earth electrode including connections/terminations with nut/bolt, spring washer as required. |
| 10 | Proving and laying of control cum communication wiring 2 core 1.5 sqmm shielded copper cable in PVC Conduit/raceway. |
| 11 | Proving and laying of PVC insulated and PVC sheathed/ XLPE power cable of following sizes with proper clamping and thimbling.(a)3.5 core x 95 sqmm LT XLPE Aluminium conductor cable from main source to LT panel of air conditioning system. |
| 12 | 4 core x 10 sqmm copper XLPE armoured conductor cable from LT panel to each ODU. |
| 13 | 3 core x 2.5 sqmm copper XLPE conductor cable from LT panel to each IDU. |
| 14 | Supply and laying of perforated hot dipped galvanized Iron cable tray of size 150mm x 50mm depth in convenient sections joint with connectors/ support etc along the wall/ceiling as required on site. |
| 15 | Design, Manufacturing, Supply, Installation, Testing and Commissioning of a digitally controlled oil cooled 125 KVA 3PH 4-wire copper wound wire Servo Automatic Voltage Stabilizer with input range of phase to neutral 150-240 volt. It should have “A” Class Insulation, degree of protection IP 54, winding and wiring material-copper EC grade(99.9% pure), transformer oil- ISI 335 Marked and Confirming to IS-9815, ISO 9001-20015, ISO-14001-2015 to operate on unbalanced input voltage of 415+1% Volts, 3 phase 50+3% cycles/second frequency, duly painted with providing and filling of transformer oil. |
| 16 | Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol Formaldehyde synthetic resin bonded pressed particle board conforming to 15:3087, finished with a coat of aluminum primer on both sides & edges, including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodized aluminum (with 15 micron anodic coating) T-sections 35 x15x1.5 mm size main runners, cross runners 23.5x19x1.5mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender