| 1 | Supply and fixing in replacement of CI sluice valve of size 150 mm dia confirming to IS -14846 PN-1.6 non raising type both ends flanged with SS spindle including jointing materials such as nuts, bolts washers,02Nos addl GI valve flanges to fix in PP-R pipes and 3mm rubber gasket 02 Nos complete all as specified and directed by Engineer-in-Charge. |
| 2 | Supply and fixing in replacement of CI sluice valve of size 100 mm dia confirming to IS -14846 PN-1.6 non raising type both ends flanged with SS spindle including jointing materials such as nuts, bolts washers,02Nos addl GI valve flanges to fix in PP-R pipes and 3mm rubber gasket 02 Nos complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply and fixing in replacement of CI sluice valve of size 80 mm dia confirming to IS -14846 PN-1.6 non raising type both ends flanged with SS spindle including jointing materials such as nuts, bolts washers,02Nos addl GI valve flanges to fix in PP-R pipes and 3mm rubber gasket 02 Nos complete all as specified and directed by Engineer-in-Charge. |
| 4 | Supply and replacement of CI Non Return / foot valve with strainer PN 1.6 having one side flanged end joint suitable size of 100 mm dia including jointing materials such as nuts, bolts washers 02Nos and 3mm rubber gasket complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply and replacement of CI Non Return/ foot valve with strainer PN 1.6 having one side flanged end joint suitable size of 80 mm dia including jointing materials such as nuts, bolts washers 02Nos and 3mm rubber gasket complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply and replacement of CI Non Return foot valve with strainer PN 1.0/1.6 having one side flanged end joint suitable size of 65 mm dia including jointing materials such as nuts, bolts washers 02Nos and 3mm rubber gasket complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply and laying in trenches Ductile Iron spigot and socket pipes as per IS:8329/2000 Class K7 including EPDM rubber gasket suitable for push on rubber gasket joint with inside cement mortar lining and outside Zinc bitumen coating of size 100mm dia to connect main pipe lines complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply and laying in trenches Ductile Iron spigot and socket pipes as per IS:8329/2000 Class K7 including EPDM rubber gasket suitable for push on rubber gasket joint with inside cement mortar lining and outside Zinc bitumen coating of size 150mm dia to connect main pipe lines complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply and fix Rubber Gasket joints suitable for 150mm dia DI pipe including jointing and jointing materials complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply and fix Rubber Gasket joints suitable for 100mm dia DI pipe including jointing and jointing materials complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for CI/DI/PP-R fittings like Connecting pieces one end flanged and other ocket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth up to 150mmdia including jointing and jointing materials complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply and fix in repair galvanised iron bolt,nut and washers of any dia and length as required at site and MS support brackets, clambs etc complete all as specified and directed by Engineer-in-Charge. |
| 13 | M & L for taking up or down from trenches for old rusted/ damaged CI/GI/ PVC Pipe including fittings and branch connections if any for removal to stores for further disposal of following dia complete all as specified and directed by Engineer-in-Charge.(a) CI 150 mm dia |
| 14 | (b) GI 100 mm dia |
| 15 | (c) GI 80 mm dia |
| 16 | (d) GI 50mm dia |
| 17 | (e) GI 40mm dia |
| 18 | (f) GI 25mm dia |
| 19 | (g) GI 20mm dia |
| 20 | Excavation in trenches not exceeding 1.5 mtr depth and not exceeding 1.5 mtr width and getting out in hard/dense soil for taking out/laying of pipe lines complete all as specified and directed by Engineer-in-Charge. |
| 21 | Returning and filling in soil including spreading, leveling, watering and well remming in layer not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge. |
| 22 | Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply and lay 3 layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 & SDR 11UV stablised and antimicrobial fusion welded having thrmal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene all type of fittings compete laid in trenches of size of outer dia 110mm pipe complete all as specified and directed by Engineer-in-Charge. |
| 24 | All as per item No.17 above but for 90mm |
| 25 | All as per item No.17 above but for 63mm |
| 26 | All as per item No.17 above but for 50mm |
| 27 | All as per item No.17 above but for 32mm |
| 28 | All as per item No.17 above but for 25mm |
| 29 | Supply and lay 3 layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 & SDR 11UV stablised and antimicrobial fusion welded having thrmal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene fittings compete laid in walls /ceilings or in floor etc of size of outer dia 25mm pipe complete all as specified and directed by Engineer-in-Charge. |
| 30 | All asper item No.23 above but for 32mm complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply and fix in replacement of gate valve, PP-R Gate valves(Brass insert) asper requirement of site for pipe 25mm size complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply and fix in replacement of gate valve, PP-R Gate valves(Brass insert) asper requirement of site for pipe 32mm size complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fix in replacement of gate valve, PP-R Gate valves(Brass insert) asper requirement of site for pipe 50mm size complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and fix in replacement of gate valve, PP-R Gate valves(Brass insert) asper requirement of site for pipe 63mm size complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and fix in replacement of gate valve, PP-R Gate valves(Brass insert) asper requirement of site for pipe 90mm size complete all as specified and directed by Engineer-in-Charge. |
| 36 | M & L for cutting of existing road/ floor/ plinth/drain for taking out/laying of GI/PP-R pipes line including necessary earth work excavation and making good to match with existing surface with PCC 1:4:8 type C1 by (using 40mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge. |
| 37 | M & L for Plain Cement Concrete 1 :3: 6 type C2 using 20mm graded stone aggregrate using as thrust block for pipe lines etc including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 38 | M&L for Construction of brick masonary valve chamber of size 1200x1200x1200mm(internal dimensions) with PCC 1:4:8 foundation 150mm thick brick masonary built in CM 1:6 PCC 1:3:6 Type C1 using 20mm graded stone aggregate coping 50mm thick plastering 15mm thick in CM 1:6 to all internal and exposed surfaces including excavation and earth work in hard/dense soil including provision of MS sheet cover 3 mm thick with locking arrangement embedded in PC coping and painting with two coats of syenthetic enamal paint over one coat of red oxide primer etc.complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&L for Construction of brick masonary valve chamber of size 900x900x900mm(internal dimensions) with PCC 1:4:8 foundation 150mm thick brick masonary built in CM 1:6 PCC 1:3:6 Type C1 using 20mm graded stone aggregate coping 50mm thick plastering 15mm thick in CM 1:6 to all internal and exposed surfaces including excavation and earth work in hard/dense soil including provision of MS sheet cover 3 mm thick with locking arrangement embedded in PC coping and painting with two coats of syenthetic enamal paint over one coat of red oxide primer etc. complete all as specified and directed by Engineer-in-Charge. |
| 40 | M&L for Construction of brick masonary valve chamber of size 600x600x600mm (internal dimensions) with PCC 1:4:8 foundation 150mm thick brick masonary built in CM 1:6 PCC 1:3:6 Type C1 using 20mm graded stone aggregate coping 50mm thick plastering 15mm thick in CM 1:6 to all internal and exposed surfaces including excavation and earth work in hard/dense soil including provision of MS sheet cover 3 mm thick with locking arrangement embedded in PC coping and painting with two coats of syenthetic enamal paint over one coat of red oxide primer etc.complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed by Engineer-in-Charge. |
| 42 | S&F in replacement single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with single pole MCB 20/ 25 Amps for incoming and out going control complete all as specified and directed by Engineer-in-Charge. |
| 43 | M & L for circuit/sub main wiring complete with 2 X 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through existing surface/recessed steel/PVC conduit and accessories with 1 X 2.5 Sqmm of PVC FRLS copper cable for earth continuity all as specified, dismantling existing U/S circuit/ sub main wiring and making good disturbed portion complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply and fixing for MCB SP 06 to 32 Amps, 10KA 240 volts,50Hz complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F 20mm PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed by Engineer-in-Charge. |
| 46 | S&F 3-layer 20mm PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls with sutabible clamps and screwes complete all as specified and directed by Engineer-in-Charge. |
| 47 | S&F Fancy type taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 48 | M&L Cutting existing steel tubing for alterations/additions incl provision of tee /adapters/union and drilling hole on wall etc. complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |