| 1 | Taking down carefully copper / aluminium point wiring light / fan, socket or power point complete including fittings such as switches, sockets, ceiling rose, bell push complete all as specified and directed. |
| 2 | M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover (cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-One light / fan point controlled by one way switch |
| 3 | All as per Item No 2.00 here-in-above but One 5 Amp socket outlet on independent board complete all as specified and directed. |
| 4 | All as per Item No 2.00 here-in-above but One 5 Amp socket outlet on same board complete all as specified and directed. |
| 5 | All as per Item No 2.00 here-in-above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and directed. |
| 6 | M & L for replacement of point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade with PVC rectangular block of suitable size including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :-One light / fan point controlled by one way switch |
| 7 | All as per Item No 6.00 here-in-above but one 5 Amps socket out let point controlled by one 1-way switch on independent board complete all as specified and directed. |
| 8 | All as per Item No 6.00 here-in-above but one 5 Amps socket out let point controlled by one 1-way switch on same board complete all as specified and directed. |
| 9 | All as per Item No 6.00 here-in-above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and directed. |
| 10 | M & L for replacement of existing conduit point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade drawn through existing conduitwith MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover ( cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-One light / fan point controlled by one switch. |
| 11 | All as per Item No 10.00 here-in-above but one 5 Amps socket out let point controlled by one switch on independent board complete all as specified and directed. |
| 12 | All as per Item No 10.00 here-in-above but one 5 Amps socket out let point controlled by one switch on same board complete all as specified and directed. |
| 13 | All as per item No 10.00 here-in-above but with 2.5 Sqmm nominal cross sectional area electric cable for 15 Amps socket outlet point controlled by one switch on independent board complete complete all as specified and directed. |
| 14 | M & L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade FRLS electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia on surface/wall/ceiling including all flame proof conduct fittings and accessories such as tees junction boxes, bends duly tested by CMRI Dhanbad suitable for one light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire FRLS PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 2.5 Sqmm and connected to earth dolly complete all as specified and directed. |
| 15 | All as per Item No 14.00 here-in-above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and directed. |
| 16 | S & F in replacement switch piano type 5 amp one way ISI marked complete all as specified and directed. |
| 17 | S & F in replacement switch piano type15 Amps one way ISI marked complete all as specified and directed. |
| 18 | S & F in replacement socket outlet 5 pin 5 Amps flush type complete all as specified and directed. |
| 19 | S & F in replacement socket outlet 2-in-1, 6 pin 5 amp and 15 amps complete all as specified and directed. |
| 20 | S & F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed. |
| 21 | S & F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed. |
| 22 | S & F in replacement switch 6 amps modular type one one way complete all as specified and directed. |
| 23 | S & F in replacement switch 16 amps modular type one one way complete all as specified and directed. |
| 24 | S & F in replacement electronic fan regulator Step type & flush type complete all as specified and directed. |
| 25 | S & F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed. |
| 26 | S & F in replacement of Lamp holder bakelite type with back plate suitable for batten fittings complete all as specified as directed |
| 27 | S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 28 | S & F in replacement of sub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 6.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 29 | S & F in replacement of Rigid non-metallic PVC conduit 25 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and directed. |
| 30 | All as per Item No 28.00 here-in-before but of size 20mm complete all as specified and directed. |
| 31 | S & F in replacement of PVC casing capping 20/25mm ISI marked complete all as specified and directed |
| 32 | M & L for fixing PVC gang box for mounting one switch and one socket of 5 Amps including all accessoriese complete all as specifies and directed. |
| 33 | M & L for fixing PVC gang box for mounting one switch and one socket of 15 Amps including all accessoriese complete all as specifies and directed. Please Enable Macros to View BoQ information |
| 34 | M & L for fixing PVC gang box for mounting one switch and one socket of 15 Amps including all accessoriese complete all as specifies and directed. Please Enable Macros to View BoQ information |