Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down carefully copper /aluminium point wiring (Light, fan, socket, or power) complete including fittings and fixture such as switches, ceiling roses pendents, regulators sockets / DBs / main switches include boards etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately), removing material, from site and making good the disturbed surfaces of walls/floor complete all as specified and directed. |
| 2 | Material and labour for point wiring for one light point/fan/bell point controlled by one switch complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core using approved colour code as per IS code drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I including all conduit accessories for concealed wiring including concealed GI flush mounting junction box of required size factory made , with modular base and cover plate of required colour for mounting modular switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting & making good disturbed surface complete all as specified and directed. Note: The rate of cutting chases required for concealing the PVC conduits alongwith the fittings / fixtures like elbow, bends , conduit, junction box, modular frame, modular plate etc and making good the disturbed surface shalll be deemed to be included in unit rate quoted and nothing extra shall be paid for this. |
| 3 | All as per Ser item No 02 here-in-before but one light point controlled by two 2-way switch with the cable 1.50 sqmm size complete all as specified and directed. |
| 4 | All as per Ser item No 02 here-in-before but for 05/06 Amp socket outlets point controlled by one switch on same board with the cable 1.50 sqmm size complete all as specified and directed. |
| 5 | All as per Ser item No 02 here-in-before but for 05/06 Amp 3 pin socket outlets point controlled by one switch on Independent board with the cable 1.50 sqmm size complete all as specified and directed. |
| 6 | All as per Ser item No 02 here-in-before but for 15/16 Amp 3 pin socket outlets point controlled by one switch on Independent socket outlet using 2.5 sqmm PVC insulated and unsheathed FRLS copper conductor single core multi stranded flexible copper cable 1100 V of approved colour code as per IS code for phase and neutral along with PVC insulated and unsheathed FRLS 2.5 sqmm multi stranded copper unsheathed cable 1100V (green color) as continuous earth lead wire connected to common earth and earth dolly complete all as specified and directed. |
| 7 | Material and labour for point wiring for one light point/fan/bell point controlled by one switch complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core using approved colour code as per IS code drawn in existing conduit incl GI flush mounting junction box of required size factory made , with modular base and cover plate of required colour for mounting modular switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting for fixing of junction box concealed in wall & making good disturbed surface complete all as specified and directed. Note: The rate of cutting chases required for concealing the Junction box incl junction box, modular frame, modular plate etc and making good the disturbed surface shall be deemed to be included in unit rate quoted and nothing extra shall be paid for this. |
| 8 | All as per ser item No 07 here-in-before but one light point controlled by two 2-way switch with the cable 1.50 sqmm size complete all as specified and directed. |
| 9 | All as per ser item No 07 here-in-before but for 05/06 Amp 3 pin socket outlets point controlled by one switch on same board with the cable 1.50 sqmm size complete all as specified and directed. |
| 10 | All as per ser item No 07 here-in-before but for 05/06 Amp 3 pin socket outlets point controlled by one switch on Independent board with the cable 1.50 sqmm size complete all as specified and directed. |
| 11 | All as per ser item No 07 here-in-before but for 15/16 Amp 3 pin socket outlets point controlled by one switch on Independent socket outlet using 2.5 sqmm PVC insulated and unsheathed FRLS copper conductor single core multi stranded flexible copper cable 1100V of approved colour code as per IS code for phase and neutral along with PVC insulated and unsheathed FRLS 2.5 sqmm multi stranded copper unsheathed cable 1100V (green color) as continuous earth lead wire connected to common earth and earth dolly complete all as specified and directed. |
| 12 | Supply and fixing for modular switch one way 5/6 Amp, 1 Module complete all as specified and directed. |
| 13 | Supply and fixing for modular socket, 5/6 amps 3 pin, 2 module complete all as specified and directed. |
| 14 | Supply and fixing for modular switch , one way, 15/16 amps, one module complete all as specified and directed. |
| 15 | Supply and fixing for modular socket 5/6 & 15/16 amps 3 pin multipin, 2 module complete all as specified and directed. |
| 16 | Supply and fixing for modular switch 2 way 6 Amp,1 module complete all as specified and directed. |
| 17 | Supply and fixing for modular bell push 5 Amp,1 module complete all as specified and directed. |
| 18 | Supply and fixing for modular fan regulator electronic step type 230 V 2 Module complete all as specified and directed. |
| 19 | Supply and fixing in repairs Ceiling rose surface type, PVC/Polycarbonate three terminals complete all as specified and directed. |
| 20 | Supply and fixing for door bell, ding dong, AC, 240 Volts, SP complete all as specified and directed. |
| 21 | Supply only PVC casing caping of size 25 mm including of all tee, bend, elbow etc with fixing accessories complete all as specified and directed. Note: Casing Caping shall be taken in charge by MES through RV. |
| 22 | Dismantling and taking down carefully by sub main wiring/service connection of any type complete all as specifed and directed. |
| 23 | Material and labour for sub main wiring using PVC insulated and unsheathed fire retardant low smoke (FRLS) copper conductor single core multi stranded unsheathed copper cable 2x4.00 sqmm (for Phase and neutral) and earth continuity conductor of size 1x4.00 sqmm multistranded copper conductor FRLS 1100V using approved colour code for phase,neutral & earth as per IS code drawn through existing conduit complete all as specified and directed.Note : (i) 3 runs of 4.00 sqmm copper cable shall be measured as one unit. |
| 24 | Material and labour for sub main wiring using PVC insulated and unsheathed fire retardant low smoke (FRLS) copper conductor single core multi stranded unsheathed copper cable 2x10.00 sqmm (for Phase and neutral) and earth continuity conductor of size 1x10.00 sqmm multistranded copper conductor FRLS 1100V using approved colour code for phase,neutral & earth as per IS code drawn through existing conduit complete all as specified and directed. Note : (i) 3 runs of 10.00 sqmm copper cable shall be measured as one unit. |
| 25 | Material and labour for sub main wiring using PVC insulated and unsheathed fire retardant low smoke (FRLS) copper conductor single core multi stranded unsheathed copper cable 2x4.00 sqmm (for Phase and neutral) and earth continuity conductor of size 1x4.00 sqmm multistranded copper conductor FRLS 1100V using approved colour code for phase,neutral & earth as per IS code drawn through non-metallic PVC rigid concealed conduit, 20 mm outer dia (Minimum dia). The external dia shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) including chases cutting & making good disturbed surface complete all as specified and directed. Note : (i) 3 runs of 4.00 sqmm copper cable & 1 run of 20 mm (Minimum dia) PVC conduit shall be measured as one unit. (ii) The rate of cutting chases required for concealing the PVC conduits alongwith the fittings / fixtures like elbow, bends , conduit/flush boxes etc. and making good the disturbed surface shall be deemed to be included in unit rate quoted and nothing extra shall be paid for this. |
| 26 | Material and labour for sub main wiring using PVC insulated and unsheathed fire retardant low smoke (FRLS) copper conductor single core multi stranded unsheathed copper cable 2x10.00 sqmm (for Phase and neutral) and earth continuity conductor of size 1x10.00 sqmm multistranded copper conductor FRLS 1100V using approved colour code for phase,neutral & earth as per IS code drawn through non-metallic PVC rigid concealed conduit, 25 mm outer dia (Minimum dia). The external dia shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) including chases cutting & making good disturbed surface complete all as specified and directed. Note : (i) 3 runs of 10.00 sqmm copper cable & 1 run of 25 mm (Minimum dia) PVC conduit shall be measured as one unit. (ii) The rate of cutting chases required for concealing the PVC conduits alongwith the fittings / fixtures like elbow, bends , conduit/flush boxes etc. and making good the disturbed surface shall be deemed to be included in unit rate quoted and nothing extra shall be paid for this. |
| 27 | Supply and fixing for LED batten (4 feet) surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 22 Watt, driver efficiency>85%, power factor > 0.9 incl dismantling and taking down old unser lights (any type) complete all as specified and directed. |
| 28 | Supply and fixing for surface and wall mounted LED Batten 10W (2 Feet) light fitting complete with tube, & duly pre-wired from fitting to ceiling rose incl dismantling and taking down old unser lights (any type) complete all as specified and directed. |
| 29 | Supply and fixing for LED bulk head 10W bulk head edge LED lighting fixture , energy efficent surface mounted ready to use pack 10W LED, complete with connecting accesseries & Driver duly pre-wired and connecting up with suitable size flexible wire complete all as specified and directed. |
| 30 | Supply and fixing for LED decorative wall light with B22 base incl LED bulb of 9 watt having base B22 complete with connecting accesseries & Driver duly pre-wired and connecting up with suitable size flexible wire incl dismantling and taking down old unser lamp holder/light (any type) complete all as specified and directed. |
| 31 | Supply and fixing for recessed mounted 2'x2' 36W LED ceiling light suitable for armstrong/grid/POP ceiling, delivers high brightness & excillent illumination complete with connecting accesseries & driver duly pre-wired complete all as specified and directed. |
| 32 | Supply and fixing for recessed mounted 1'x1' 20W LED ceiling light suitable for armstrong/grid/POP ceiling, delivers high brightness & excillent illumination complete with connecting accesseries & driver duly pre-wired complete all as specified and directed. |
| 33 | Supply only LED bulb 9 watt with B22 base complete all as specified and directed. Note: bulb shall be taken in charge by MES through RV. |
| 34 | Supply and fixing for 1'x4' 40 W LED suitable for armstrong/grid/POP ceiling,/Surface ultra slim 1x4 LED flat panel delivers high brightness & excellent illumination with extruded Aluminium housing provided for heat resistant frosted diffuser for glare free uniform light distribution & Driver duly pre-wired and connecting up with suitable size 3 core flexible wire complete all as specified and directed . |
| 35 | Supply and fixing for round shape 12 watt 220 volts AC recess mounting LED round down lighter with high efficient clear diffuser, IP 20 including connecting up with three core flexible copper conductor cable of suitable size complete fixing complete all as specified and directed. |
| 36 | Supply and fixing in repair LED Post top lantern luminaire with die cast aluminium spigot, lid cover and clear acrylic cover 40 watt, 5700 K with IP-65 protection incl connection complete all as specified and directed. |
| 37 | Supply and fixing for bed side LED lamp 5 Watt with flexible gooseneck, bedside fixture with push button switch including connection complete all as specified and directed. |
| 38 | Supply and fixing for sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 double door complete with 200 Amps rated bus bar, earth link and neutral link with provision for fixing incomer and outgoing MCBs as outgoing switchgears, fixed flush in wall including chases cutting in wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. Note - MCBs shall be measured separately. |
| 39 | Supply and fixing in repairs sheet metal enclouser distribution board 415volt, Vertical TPN 8 Way (load line DB) with provision for suitable MCCB FP up to 160 A as incomer & MCBs as out going as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mounting IP-43 protection, including connection with the existing sub circutis, electric meter etc with proper size new copper cable, lugs,connectors etc complete all as specified and directed. Note - MCCB & MCBs shall be measured separately. |
| 40 | Supply and fixing in repairs sheet metal enclouser distribution board 415volt, Vertical TPN 4 Way (load line DB) with provision for suitable MCCB FP up to 125 A as incomer & MCBs as out going as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mounting IP-43 protection, , including connection with the existing sub circuits, electric meter etc with proper size new copper cable, lugs,connectors etc all as specified and directed. Note - MCCB & MCBs shall be measured separately. |
| 41 | Supply and fixing for sheet metal enclosure MCB distribution board TPN 415 volts 04 way with IP-43 double door complete with 200 Amps rated bus bar and neutral link with provision for MCB as incomer and MCBs as outgoing switchgears, fixed flush in wall including chases cutting in wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. Note - MCBs shall be measured separately. |
| 42 | Supply and fixing in repairs MCCB, 4-pole, adjustable breaking capacity 16 KA, 415 volts, 125 Amps including taking down unservicable one complete all as specified and directed. |
| 43 | Supply and fixing in repairs MCB SP 6 to 32 Amps 240 volts 10 KA ''C''Series complete all as specified and directed. |
| 44 | Supply and fixing in repairs MCB SPN 40 to 63 Amps 240 volts 10 KA ''C''Series complete all as specified and directed. |
| 45 | Supply and fixing in repairs MCB TPN 40 to 100 Amps 415 volts Breaking capacity 10KA C Series complete all as specified and directed. |
| 46 | Supply and laying PVC insulated flexible unarmoured cable three core copper conductor 1.5 sqmm size 1100 volt grade complete all as specified and directed. |
| 47 | Supply and fixing for portable residual current device (PRCD) 30 mA , 16 Amps plug/Socket Top for Geyser and other electric devices suitable for fitting in existing power sockets incl dismanting and taking down old u/s normal plug top at any type complete all as specified and directed. |
| 48 | Supply and fixing for DBOX MCB protected socket , single phase, with MCB 20 Amps 'C' curve with plastic enclosure 4 module suitable for AC and other electrical connection incl dismantling and taking down old unser switch sockets box or AC socket box or MCB enclosure 2 module (PVC/Metal) as per actual complete all as specified and directed. |
| 49 | Supply only capacitor of 2.5 mfd , 240 V, complete all as specified and directed. Note: capacitor shall be taken in charge by MES through RV. |
| 50 | Supply only down rod for ceiling fan of 19/20 mm dia of mild steel pipe of 75/90 cm long complete all as specified and directed. Note: Rod shall be taken in charge by MES through RV. |
| 51 | Supply only PVC connections 15 mm size with PTMT nuts of length 450 mm suitable for Water coolers/Geysers complete all as specified and directed. Note: PVC connections shall be taken in charge by MES through RV. |
| 52 | Supply only PVC connections 15 mm size with PTMT nuts of length 600 mm suitable for Water coolers/Geysers complete all as specified and directed. Note: PVC connections shall be taken in charge by MES through RV. |
| 53 | Supply only of apparatus plate (Geyser Assembling Unit) with rubber gasket including nuts, bolts and washers consisting of 6/9 Nos of holes suitable for existing geysers complete all as specified and directed. Note: Appratus shall be taken in charge by MES through RV. |
| 54 | Supply only heating element of geyser 2.0/1.5 KW as existing pattern complete all as specified and directed. Note: Heating elements shall be taken in charge by MES through RV. |
| 55 | Supply only Inner Tank of geyser of capaciy 25 Ltrs as existing pattern incl taking down and refixing complete all as specified and directed . Note: Inner Tanks shall be taken in charge by MES through RV. |
| 56 | Supply only outer Body cover of geyser of capaciy 25 Ltrs as existing pattern incl taking down and refixing complete all as specified and directed. Note: Outer body cover shall be taken in charge by MES through RV. |
| 57 | Supply only LED indicator (Red & Green) with wire for connectionfor geyser complete all as specified and directed. Note: LED indicator shall be taken in charge by MES through RV. |
| 58 | Supply only electric geyser safety valve as per existing complete all as specified and directed. Note: Electric geyser safety valve shall be taken in charge by MES through RV. |
| 59 | Supply only Thermostat 7'/11' for geyser with adjustable temperature setting range complete all as specified and directed. Note: Thermostat shall be taken in charge by MES through RV. |
| 60 | Supply only PVC plug top 3 pin 16 amps suitable for 230 volts AC supply complete all as specified and directed.Note: plug top shall be taken in charge by MES through RV. |
| 61 | Material and labour for cutting brick wall, making a hole suitable for fixing exhaust fan of sweep upto 600 mm and making good distyrbed surface complete all as specified and directed. |
| 62 | Supply and fixing for wall mounted fan 400 mm sweep,1400 RPM, heavy duty motor with double ball bearing, aerodynamicaly design blades with provision of flexible cord 3 core stranded copper conductor of size 0.50 sqmm from connector block to fan complete incl taking down old u/s all as specified and directed. Note- old u/s material shall be property of MES. |
| 63 | Supply and fixing for exhaust fan metalic body size 300 mm sweep with louvers, operated on 230/240V AC Single phase electric supply 900 RPM complete including connecting with 3 core stranded copper conductor cable cord of size 0.5 sqmm from ceiling rose to fan connector incl taking down old u/s exhaust fan complete all as specified and directed. Note- old u/s material shall be property of MES. |
| 64 | Supply and fixing for exhaust fan made of sturdy Engineering plastic size 250 mm sweep with louvers and shutter, voltage 230/240V, 50Hz, AC single phase electric supply 1200 RPM complete including connecting with 3 core stranded copper conductor cable cord of size 0.5 sqmm from ceiling rose to fan connector incl taking down old u/s exhaust fan complete all as specified and directed.Note- old u/s material shall be property of MES. |
| 65 | Supply and fixing of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, minimum air delivery 210 CM/Min (Minimum), class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, with remote for on/off and speed control and all remaining accessories including safety pin, nut bolts, washers,suitable for 230/240V, 50 Hz, single phase AC Supply, earthing etc incl taking down old u/s complete all as specified and directed.Note- old u/s material shall be property of MES. |
| 66 | Supply only pvc electrical insulation tape size 6 Meter with fire retardant and water proof complete all as specified and directed.Note:- Tape shall be taken in charge by MES through RV. |
| 67 | Material and labour in replacement printed circuit board (PCB) after dismantling, taking down and refixing after repairing of BLDC fan any type any size incl dismantling and taking down and refixing the same after repairing complete all as specified and directed. |
| 68 | Supply only remote for BLDC ceiling fan (25-38 W) for 1200 mm sweep suitable for Bajaj/Orient/Crompton/Havells fan as per sample without batteries complete all as specified and directed. Note: Remote shall be taken in charge by MES through RV. |
| 69 | Supply only PVC gang box suitable for one switch & socket 6/16 Amps complete with screw and necessary arrangement complete all as specified and directed.Note:- gang box shall be taken in charge by MES through RV. |
| 70 | Material and labour for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth electrode connected connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 incl PCC earth pit with CI frame and RCC cover including testing and dismantling ,taking down old unser earthing complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, watering pipe, earth lead protection pipe, porcelain insulator,PCC earth Pit, RCC cover, funnel with wire mesh shall be deemed to be included in the unit rate quoted. |
| 71 | Material and labour for Wet servicing of split AC by highly skilled technician incl both Indoor and outdoor units using water and specialized cleaning agents to throughly clean the cooling coils, condenser coils, outside panels, drain and fillet pipes by using pressure jet ,jet pump, jackets cover to prevent spills, cleaning foam, blowers, brush,cleaning cloths etc complete servicing with additional checks as: (i) Check for Gas Pressure (ii) Check for Power Consumption (iii) Check for level of indoor unit for proper water flow (iv) Check Thermostat (v) Check all electrical connections and tighten them. |
| 72 | Material and labour for Wet servicing of window AC by highly skilled technician using water and specialized cleaning agents to throughly clean the cooling coils, condenser coils, outside panels, drain and fillet pipes by using pressure jet ,jet pump, jackets cover to prevent spills, cleaning foam, blowers, brush,cleaning cloths etc complete all as specified and directed. Servicing with additional checks as:(i) Check for Gas Pressure (ii) Check for Power Consumption (iii) Check for level of indoor unit for proper water flow (iv) Check Thermostat (v) Check all electrical connections and tighten them. |
| 73 | Material and labour for dismantling and taking down split AC after restoring gas and disconnection of all electrical and copper tubes incl dismantling stands for outdoor unit and deposited to MES store yard complete all as specified and directd. Note: Rate of arrangement (ladder/Scaffolding) for reaching at a height for dismantling and taking down outdoor unit from multi-story buildings shall be deemed to be included in the unit rate quoted. |
| 74 | Material and labour for installation and mounting of split AC incl all electric and copper tube connections, drilling on brick wall (up to 12\\") for copper tube & drain pipe and interconnecting them with electrical wires and communication cables with proper testing after installation complete all as specified and directed. Note:Rate of arrangement (ladder/Scaffolding) for reaching at a height for installation outdoor unit to multi-story buildings shall be deemed to be included in the unit rate quoted. |
| 75 | Material and labour for carrying out leakage testing of split/window type air conditioner of capacity 1.5 / 2.0 TR of existing make and type, charging dehydrated Nitrogen gas upto 280 PSI in refrigerant system for a period of 24 hours for detecting leakages and repairing of tubing by brazing / welding suitably and repeating the pressure test to obtain 100% leak proof condition in the system, charging the refrigerant gas R-22 / 410-A/R-32 and testing complete all as specified and directed. |
| 76 | Supply and fixing for stand for outdoor unit of split AC incl heavy duty wall stand (set of 2) suitable for 1/1.5/2 TON AC, nut, bolts, fastners etc complete all as specified and directed. |
| 77 | Supply and fixing for 3 core 2.5 sqmm copper flexible wire for connection/interconnection of IDU and ODU complete all as specified and directed. |
| 78 | Supply and fixing for drain PVC pipe 20 mm dia including all tee and bends complete all as specified and directed. |
| 79 | Supply and fixing of Two run of copper tubing of suitable dia for 1.5/2.0 TR split AC incl standard insulation,1 run of 3 core 2.5 sqmm flexible copper cable for interconnection between outdoor and indoor unit complete all as specified and directed by Engr-in-Charge. Note : (i) 2 Run of copper pipes incl insulation and 1 run of copper wire shall be measured as 01 RM. |
| 80 | Supply and fixing for 50+6 MFD capacitor, brust proof, ISI marked, 440 V AC, round Aluminium suitable for Split/Window AC of capcacity 1.0/1.5/2 TON complete all as specified and directed. |
| 81 | Charges for attending minor complaints for split AC , water cooler, and desert cooler to rectify the minor diffects I,e checking of electrical connections, mode of ACs , temporary defaults complete all as specified and directed. |
| 82 | Supply and fixing for automatic voltage stabilizer of capacity 4 KVA incl dismantling and taking down old u/s complete all as specified and directed |
| 83 | Supply and fixing for capacitor 10 MFD suitable for air conditioner/ water cooler complete all as specified and directed |
| 84 | Supply and fixing for capacitor 4 mfd for desert/water cooler as required at site complete all as specified and directed |
| 85 | Supply and fixing in replacement new condenser fan motor (DC /AC )(outdoor) for split type A/C unit of capacity 1.5/2.0 TR as per existing model complete all as specified & directed. |
| 86 | Supply and fixing in replacement of polypropylene filter mesh air filter for split type A/C units of capacity 1.5 TR/2 TR as per sample complete all as specified and directed. |
| 87 | Supply and installation in replacement indoor unit complete 1.5 TR 5 star BEE rating, inverter type compatible with existing outdoor unit of make as per existing of split AC of cap 1.5 TR all as specified and as directed. Note: Old u/s items shall be the property of MES and shall be deposited in MES store yard. |
| 88 | Supply and fixing in replacement of starting relay for split type AC units of capacity 1.5/2 TR as required at site complete all as specified and directed. |
| 89 | Supply and fix in replacement of contactor (Mnx type), 32 Amps 3-phase (NO) as per existing model, coil voltage 230 V installed in split type AC units all as specified and as directed. |
| 90 | Supply and fix in replacement of indoor unit blower motor suitable for Split AC Capacity 1.5 / 2.0 TR complete all as specified and directed. |
| 91 | Supply and fixing for compressor of capacity 2.0 TR from split type AC unit as per existing models including flushing, dehydration incl disantling and taking down old unser complete all as specified and directed. |
| 92 | Supply and fixing for compressor of capacity 1.5 TR from split type AC unit as per existing models including flushing, dehydration incl disantling and taking down old unser complete all as specified and directed. |
| 93 | Supply and installation in replacement outdoor unit complete 1.5 TR 5 star BEE rating, inverter type compatible with existing indoor unit of make as per existing of split AC of cap 1.5 TR complete all as specified and directed. Note: Old u/s items shall be the property of MES and shall be deposited in MES store yard. |
| 94 | Supply and fix in replacement the new remote control unit (cordless) with batteries as per existing model for 1TR/1.5 TR/ 2 TR split type A/C unit complete all as specified & directed. |
| 95 | Supply and fix in replacement condenser fan blade for split AC 1.5/2.0 TR complete all as specified and directed. |
| 96 | Supply and fixing in replacement of unserviceable printed circuit board (PCB) suitable for 1.5 Ton window type AC of existing make and type complete all as specified and as directed. |
| 97 | Supply and fixing in replacement of unserviceable printed circuit board (PCB) suitable for 1.5 / 2.0 Ton split type AC of existing make and type complete all as specified and as directed. |
| 98 | Supply and fixing in replacement of thermostat for window/split type AC 1TR/1.5/2.0 TR as required at site complete all as specified and directed. |
| 99 | Supply and fixing in replacement of overload protector for compressor as reqd at site for AC/ water cooler complete as specified and directed by Engineer-in-charge. |
| 100 | Supply and fixing in replacement starting relay as required at site for water coolers complete including connecting, testing complete all as specified and directed . |
| 101 | Taking down the water cooler of any capacity / make / size from site, opening side covers of water cooler and overhauling / servicing of water cooler by carrying out the following works at different location complete all as specified and directed. (a) Inspection, taking down opening & dismantling descaling brushing cleaning of storage tanks (b) Examine water tightness of stotage tank after cleaning (c) Carry out operations of stop cock, push cock, float valve etc (d) Replace washer & glands of all taps to ensure water tightness (e) Inspect over flow and remove blockage obstruction if any (f) Check and correct earth continuity of electrical items (g) Check thermostate and test its functioning (h) Inspect drain pipe and remove blockage if any (j) Check & correct all electrical wiring and its functioning (k) Testing of water coolers after repairs for satisfactory functioning complete. |
| 102 | Taking out old unserviceable compressor of water cooler of capacity 40 / 80 to 60 / 120 litres any make / size and providing new company sealed compressor and connectig up suction and discharge copper pipe including extra copper tubing with brazing work, gas welding, pressure testing of leakage,leakage rectification, vacumising and charging of refrigerant gas R-22/ Non-CFC as applicable upto required level testing comissioning complete all as specified and directed. |
| 103 | Disconnecting and taking out water cooler of any type any capacity and refixing the same after removal of leakage in condensor of cooling coil including flushing dehydration and charging refrigerant gas R-22/Non-CFC as applicable in the system including pressure testing, vaccumising and extra copper tubing complete and testing the water cooler for proper functioning in workshop complete all as specified and directed. |
| 104 | Supply and fixing condenser motor single phase for water coolers of cap 40/80 ltr as per existing incl dismantling and taking down old unser with clamps bolts, nuts and rubber bushes including connecting, testing complete all as specified and directed. |
| 105 | Supply only new desert cooler water pump including connection for proper functioning complete all as specified and directed . |
| 106 | Supply only cooler wood wool pad set of three for desert cooler complete all as specified and directed. |
| 107 | Supply only desert cooler motor single phase, 50 Hz, 240 Volt, 180 W, 1400 RPM complete all as specified and directed |
| 108 | Material and labour for repairing printed circuit board (PCB) after dismantling, taking down and refixing after repairing of Split/Window AC or AC plant any type any capacity incl dismantling and taking down and refixing the same after repairing complete all as specified and directed. |
| 109 | Supply only digital clamp meter ,600A AC/DC range, .01A high resulution,battery powered all as specified and directed.Note: clamp meter shall be taken in charge by MES through RV. |
| 110 | Supply and fixing for pure sine wave Automatic Inverter / home UPS for auxillary AC/DC supply equipped with fan for cooling, power active switch, MCB protection and bypass switch which keeps supplying output from grid even in case of inverter faults, LCD display, charging current not less than 12A, efficiency 95 %, suitable for 24 Volts incl 2 nos batteries, 12 volts and 150 AH (with 24 Month warranty) each Input 220/240 Volts, 50 Hz, output power not less than 1200 Watt , 220/240 vots AC alongwith standard accessories incl dismantling and taking down old u/s power pack complete all as specified and directed. |
| 111 | Supply and fixing in replacement of instrial RO+UV+TDS water purification with TDS aduster capacity 25 LPH, full stainless steel body with double pump purification complete all as specified and directed.Note:-old u/s item shall be property of MES and shall deposited to MES store. |
| 112 | Servicing and testing the Industrial RO of cap upto 50 LPH incl replacement of unser parts complete all as specified and directed. Note: (i) Part shall be measured and paid for separately under relevent item. |
| 113 | Supply only 10 inch wall hanking Kit with paper packing suitable for induatrial RO of capacity up to50 LPH complete all as specified and directed. |
| 114 | Supply only RO membrene suitable for industrial RO of capacity upto 50 LPH complete all as specified and directed. |
| 115 | Supply only pre carbon filter suitable for industrial RO of capacity upto 50 LPH complete all as specified and directed. |
| 116 | Supply only post carbon filter suitable for industrial RO of capacity upto 50 LPH complete all as specified and directed. |
| 117 | Supply only inline filter set suitable for industrial RO of capacity upto 50 LPH complete all as specified and directed. |
| 118 | Supply only UV filter set suitable for industrial RO of capacity upto 50 LPH complete all as specified and directed. |
| 119 | Supply only sediment filter suitable for industrial RO of capacity upto 50 LPH complete all as specified and directed. |
| 120 | Supply only pressure switch suitable for industrial RO of capacity upto 50 LPH complete all as specified and directed. |
| 121 | Supply only booster pump 24/36 VDC/VAC , suitable for industrial RO of capacity upto 50 LPH complete all as specified and directed. |
| 122 | Supply only power supply adapter/SMPS 24/36 volt, suitable for industrial RO of capacity upto 50 LPH complete all as specified and directed. |
| 123 | Supply only solenoid valve 24/36 volt, suitable for industrial RO of capacity upto 50 LPH complete all as specified and directed. |
| 124 | Supply and fixing in replacement energy saving & environmental friendly long life LED street light not less than 50 watt made up of pressure die cast housing with toughned glass and individual high power LEDs ,IP55/66 protection, impact resistant, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, Power factor> 0.95, built in surge protection of up to 5kV incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy