| 1 | Dismantling of Split AC. Complete in all respect as per direction of E/I.(AOR) |
| 2 | Installation of Split AC. Complete in all respect as per direction of E/I. (AOR) |
| 3 | Dismantling of Window AC. Complete in all respect as per direction of E/I. (AOR) |
| 4 | Installation of Window AC. Complete in all respect as per direction of E/I. (AOR) |
| 5 | Supply & Fixing Copper Pipe Insulating PVC Coated. Complete in all respect as per direction of E/I.(AOR) |
| 6 | Supply & Fixing of Accessories Set(Running Capicitor, Starter Capicitor, Starter Relay etc) Complete in all respect as per direction of E/I.(AOR) |
| 7 | Supply & Fixing of Motor( 1/4 HP, 1/6 HP, 1/8 HP & Different Capcities of AC) Complete in all respect as per direction of E/I.(AOR) |
| 8 | Supply & Fixing of Gas Compressor for 1.5 Ton Window & Split AC .Complete in all respect as per direction of E/I.(AOR) |
| 9 | Supply & Fixing of Cooling Coil(Evaporator) for 1.5 Ton Window & Split AC. Complete in all respect as per direction of E/I.(AOR) |
| 10 | Supply & Fixing of Heat Exchanger for 1.5 Ton Window & Split AC.Complete in all respect as per direction of E/I.(AOR) |
| 11 | Supply & Fixing of PCB(Printed Circuit Board) for 1.5/2.0 Ton Window & Split AC. Complete in all respect as per direction of E/I.(AOR) |
| 12 | Supply & Fixing of FCU(Fan Coil Unit) 1.5/2.0 Ton for Split AC. Complete in all respect as per direction of E/I.(AOR) |
| 13 | Supply & Fixing Angle Stand for Outdoor Unit. Complete in all respect as per direction of E/I.(AOR) |
| 14 | Supply & Fixing of Fan Blade (12\\" to 18\\") Complete in all respect as per direction of E/I.(AOR) |
| 15 | Supply & Fixing of Blower (320x900 mm & 360 x 930 mm) Complete in all respect as per direction of E/I.(AOR) |
| 16 | S/L of 2.5 sq.mm 3 core , PVC Insulated copper cable . Complete in all respect as per direction of E/I.(AOR) |
| 17 | Supply & Installation of Split Type 1.5 Ton, 3 Star AC including 4 KVA Voltage Stabilizer, Angle Stand, 3 Mtr Copper Pipe, Drain Pipe & Cable. Complete in all respect as per direction of E/I.(AOR)Make- Carrier, Voltas, O General, Hitachi |
| 18 | Supply & Installation of Split Type 2.0 Ton, 3 Star AC including 4 KVA Voltage Stabilizer, Angle Stand, 3 Mtr Copper Pipe, Drain Pipe & Cable. Complete in all respect as per direction of E/I.(AOR) Make- Carrier, Voltas, O General, Hitachi |
| 19 | Supply & Installation of Window Type 1.5 Ton, 3 Star AC including 4 KVA Voltage Stabilizer. Complete in all respect as per direction of E/I.(AOR)Make- Carrier, Voltas, O General, Hitachi |
| 20 | Supply & Installation of Window Type 2.0 Ton, 3 Star AC including 4 KVA Voltage Stabilizer. Complete in all respect as per direction of E/I.(AOR)Make- Carrier, Voltas, O General, Hitachi |
| 21 | Supply & Fixing of 12.70 mm dia copper refrigerant piping for the above indoor & outdoor units, copper Piping shall be properly supported and it shall including the cost of all the fitting, insulation, UV coating and all required fittings, joints etc. as per drawing of the following sizes (The insulation shall be 13/19 mm thick closed cell nitrile rubber tubular insulation and all internal and external pipe shall runon proper cable tray )AOR |
| 22 | Supply & Fixing of 6.4 mm dia copper refrigerant piping for the above indoor & outdoor units, copper Piping shall be properly supported and it shall including the cost of all the fitting, insulation, UV coating and all required fittings, joints etc. as per drawing of the following sizes (The insulation shall be 13/19 mm thick closed cell nitrile rubber tubular insulation and all internal and external pipe shall runon proper cable tray )AOR |
| 23 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (DSR-2018- 2.18) Please Enable Macros to View BoQ information |