| 1 | Supply and fixing of Mast Nut, Bolt & templates suitable for 30 Mtr High mast. Complete in all respects as per directiion of E/I.(AOR) |
| 2 | Supply and fixing of Winch Machine assembly suitable for 30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 3 | Supply and fixing of SS Rope Wire 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 4 | Supply and fixing of Lantern Carriage made of 2.5\\" outer dia G.I. Pipe Class B heavy duty for mounting the luminaries suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 5 | Supply and fixing of Head Frame with Pulley suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 6 | Fixing of 30 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. on existing foundation. Complete in all respect . As per direction of E/I. (AOR) |
| 7 | Dismantling of 16 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. Complete in all respect . As per direction of E/I. (AOR) |
| 8 | Fixing of 16 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. on existing foundation. Complete in all respect . As per direction of E/I. (AOR) |
| 9 | Supply and fixing of Window Door/Cover size as per 16Mtr/30 Mtr High mast made of 3mm thick MS Sheet with 2 Nos heavy duty lock shutter type incl. hinged. Complete in all respects as per directiion of E/I. (AOR) |
| 10 | Supply and fixing of Aviiation Light suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 11 | Supply and fixing of MS Lighting arrestor rod suitable for 16Mtr/30 Mtr High Mast. Complete in all respects as per directiion of E/I. (AOR) |
| 12 | Supply and fixing of fibre Junction Box suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 13 | Supply and fixing of Mast Nut, Bolt & templates suitable for 16 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 14 | Supply and fixing of Winch Machine suitable for 16 Mtr High mast. Complete in all respects as per directiion of E/I.(AOR) |
| 15 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. DSR Electricals 2018 No. 9.3a) 2 X 16 sq. mm (9.3.1) |
| 16 | b) 2 X 25 sq. mm (9.3.2) |
| 17 | c) 4 X 16 sq. mm (9.3.29) |
| 18 | d) 3.5 x 50 sq. mm (9.3.19) |
| 19 | S/L of Al conductor PVC/XLPE insulated rmoured served sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand alround & protected with burnt on sides & on top surface the cable run shall be fixed on M.S. Clamps etc of suitable size or as directed by complete in all respects. The armoruring of the cable shall be properly connected with the earth conductor by clamps etc. P S No 501 -16 sqmm x 4 core |
| 20 | 25 sq. mm 3-1/2 core |
| 21 | 50 sq. mm 3-1/2 core |
| 22 | S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) -ii) 50 Sqmm |
| 23 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR 14.16.1a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 24 | b) 90 mm dia (OD-90 mm & ID-76 mm nominal) (14.16.2) |
| 25 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) 2018 |
| 26 | S/L of 25x3mm G.I. Strip from earth electrode directly in the ground as required Complete in all respects as per PS No. 716 |
| 27 | Supplying and fixing of light class G.I. pipe of 80 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required. DSR Electrical-18/ 12.38 |
| 28 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 25 A TPN PS No.-807 e (ii) |
| 29 | Supply and laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.PS 506 a) 120 sq. mm 3 core |
| 30 | S/F of jointing of following sizes outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson Make) uperc Pg-41 120 Sqmm |
| 31 | S/Making of Straight through joint suitable for 120 sq.mm x 3 core 11 KV armoured cable as per ISS & complete as per the direction and satisfaction of E/I (Raychem, Denson, Cabseal Make) UPERC 2019 Pg-27 |
| 32 | S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I.. (AOR) |
| 33 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 34 | Location and pin pointing of 11KV HT Cable fault exposing the same in the underground 11KV Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 35 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by expert technical staff. (AOR) |
| 36 | Pole Bus bar support connector 3 way with Backsheet. Completed in all respects. (AOR) |
| 37 | Pole Bus bar support connector 4 way with Backsheet. Completed in all respects. (AOR) |
| 38 | Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects P.S. No. 627 |
| 39 | S/f of 11 KV Disc insulator 70 KN and fitting B&S heavy duty with clamp of cross arm fixed on ht pole BHEL/ Jai shree / WS/RR make UPERC 19 P No 24 I No 9 |
| 40 | S/f of 11 KV Pin 12 long with insulator of Jai shree/BHEL on cross arm fixed on HT pole including all T/P etc UPERC P No 26 I No 7 |
| 41 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.07/S.N. 279 |
| 42 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 43 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. bituminous portion (AOR) |
| 44 | ii) Water bound macadam (AOR) |
| 45 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars (AOR) |
| 46 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil. (AOR) |
| 47 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns (AOR) |
| 48 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection. UPPWD-2018, PS-1455 CAT-AAA |
| 49 | Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge. (Civil AOR) Please Enable Macros to View BoQ information |