| 1 | TOTAL |
| 2 | S & I OF PAPER SHREDDER MACHINE |
| 3 | ERECTION AND INSTALLATION OF BOTH COOLING AND CONDENSING UNIT FOR 1.5 TON SAC AT RESPECTIVE LOCATION ON WALL ALONG WITH TERMINATION OF REFRIGERANT LINE AS PER DIRECTION OF EIC MENDING GOOD DAMAGE TO ORIGINAL FINISH. |
| 4 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF SUCTION/ DISCHARGE COPPER PIPE LINE IN SPLIT AIR CONDITIONING UNIT 1.0/1.5 TR/2 TR/3 TR CAPACITY INCLUDING BRAZING, NITRILE RUBBER INSULATION 6/9MM THICK CLASS 'O', ETC COMPLETE AS REQUIRED.COPPER TUBE 3/8\\"[I&W WAYS SCHEDULE 2022, P-117,I-5.3 H.4.2] |
| 5 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF SUCTION/ DISCHARGE COPPER PIPE LINE IN SPLIT AIR CONDITIONING UNIT 1.0/1.5 TR/2 TR/3 TR CAPACITY INCLUDING BRAZING, NITRILE RUBBER INSULATION 6/9MM THICK CLASS 'O', ETC COMPLETE AS REQUIRED.COPPER TUBE 5/8\\"[I&W WAYS SCHEDULE 2022, P-117,I-5.3 H.4.4] |
| 6 | PROVIDING & FIXING OF ISI MARKED (IS : 15778 - 2007) A) 20MMDIA RIGID CPVC DRAIN WATER PIPING 6 KG/ CM2 WITH FITTINGS LIKE ELBOW, SOCKET, TEE ETC& SUPPORT WITH MS HANGER ON CEILING OR RECESSED IN WALL WITH CHASING & PLASTERING WITH 6 MM THICK CLOSED CELL ELASTOMERIC NITRILE RUBBER INSULATION COMPLETE IN ALL RESPECT. [I&W WAYS SCHEDULE 2022, P-117, I-5.3 H.2] |
| 7 | GAS CHARGING (R410A/ECO FRIENDLY GREEN GAS) OFWINDOW/ SPLIT AIR CONDITIONING UNIT INCLUDING FLUSHING OF COOLING & CONDENSING UNITS WITH NITROGEN GAS & RECTIFICATION OF LEAKAGE, REPLACEMENT OF FILTER, FLAIR NUT ETC. IF ANY.1.5 TR [I&W WAYS SCHEDULE 2022, P-117,I-5.3 H.5.2] |
| 8 | SUPPLY TMC501 CONVENTIONAL INDUSTRIAL BATTEN PHILIPSLEDTUBE, MODEL NO : TMC 501 P 2XT-LED 22W P3242 WITH 2NOS MAS LEDTUBE 1200MM 18W865 T8 I - 2100LM INCLUDING NECESSARY CONNECTION.[I&W WAYS SCHEDULE 2022, P-113,I-5.3 F.20] |
| 9 | SUPPLY PHILIPS LEDTUBE, MODEL NO : MAS LEDTUBE 1200MM 18W865 T8 I - 2100LM[I&W WAYS SCHEDULE 2022, P-113,I-5.3 F.23] |
| 10 | SUPPLYING OF APPROVED MAKE HIGH SPEED CEILING FAN(ISI MARKED) OF FOLLOWING SIZES HAVING DOUBLE BALL BEARING COMPLETE WITH STANDARD DOWN ROD, CANOPY, HANGING SHACKLE, ALUMINIUM BLADES, WITHOUT REGULATOR, A.C. 230-250 VOLTS 900MM/ 1050MM/ 1200MM [I&W WAYS SCHEDULE 2022, P-115,I-5.3 G.1.1] |
| 11 | Schedule of Rates FOR Wiring in PVC Insulated and Sheathed Wirein EI Conduits/ GI Conduits By single core stranded Copper conductor.Distribution wiring in 2x1.5 sqmm single core PVC insulated stranded Copper wire in 19 mm in black stove EI conduit/GI conduit to 3 pin Plug Points incl. S&F 5 A Piano Key type switch with earthing attachment in 16 SWG GI Wire and painting.(c)Average run 3 mtr.EI Conduit |
| 12 | Concealed Wiring With PVC Insulated and Sheathed Wires in Polythene Pipes - Laying & Fixing PolythenePipe, MS Boxes, Switches etc.Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand(approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing FOR switch by cutting bakelite/perspex cover and making necessary connections asrequired |
| 13 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated& unsheathed copper wire brand(approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC |
| 14 | Fixing only TPN MCBDB in Sheet Steel enclosure (4 to 12 way) on flat iron frame on wall 415V TP/TPN |
| 15 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A SP |
| 16 | Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 50 7/3.00 4 |
| 17 | BUILDING WORKS (G) WOOD AND PVC WORKS D.ACCESSORIES 9. Iron skeleton bolt of approved quality fitted and fixed complete. (b) 450mm long x 10mm dia rod. |
| 18 | BUILDING WORKS(R) ALUMINIUM WORKS???(1)Supplying profilesof required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized(with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A) In 10-12 Micron thickness Annodizing film. I) Natural white. e) Casement window ( 40 mm Depth series). v) Cleat angle. (Non-annodized) |
| 19 | Concealed Wiring With PVC Insulated and Sheathed Wires inPolythene Pipes - Laying & Fixing PolythenePipe, MS Boxes, Switches etc.Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 25 mm dia 3 mm thick polythene pipe without earth continuity wire Please Enable Macros to View BoQ information |