| 1 | Providing and laying of hard core fill (stone soling) tightly packed in foundation trench under footing, paving and other locations, with approved hard rounded stones of size (size 50mm-80mm) and down, thoroughly filled with smaller chips, dry soling and consolidated to the required level complete before laying of mud mat all complete carriage upto site of work all head loads complete job. |
| 2 | Providing and laying in position cement concrete specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: 4.4.5 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 3 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.10.2.2 Welded. All the tools and tackles required for execution of job including necessary power backup shall be arranged and brought to the site by the contracting agency. Steel which includes hollow pipes, sheets, plates to be used strictly as per drawing and as per directions of site incharge. |
| 4 | 17.20-Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment) |
| 5 | 1.1.2-Carriage of excavated earth including Mechanical transport/ loading/unloading and stacking at site upto 5Km 250.92 and upto 10 km @ 19.58 per Km and Beyond 10 km upto20 km per @ 16.36 per Km Maximum distance taken 20 km (250.92+97.60+163.60)=512.12 |
| 6 | Providing and fixing precoated galvanized iron profile sheets (size, shape, colour and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling/self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 7 | ACCESSORIES: Providing and fixing precoated galvanized steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self-tapping screws complete :12.24.1 Ridges plain (500 - 600mm) |
| 8 | Providing and fitting of polycarbide transparent sheets(as per sample) having good Thermal properties, Lightweight UV -resistant to prevent yellowing and maintain optical clarity over time crucial for outdoor applications to ensure the longevity of the material. The job includes providing fitting of H-connector railings mainly of Aluminum with proper sealant. The job includes p/fixing of scaffolding /shuttering as per site requirement taking every precaution for men at work as per work norms. All the Tools Tackles/Labour/Accessories/ Metal hardware etc. required for the job to be arranged by the firm. |
| 9 | Providing and fitting of 50mm Thick rigid PUF, CFC free conforming to IS-12436-88 with subsequent amendments having density of 40kg/m3 sandwiched between 0.4-0.5mm thick pre painted galvanized steel sheet as per IS-14246-95 with subsequent amendments with 18-20 microns of exterior polyester coating of white color on epoxy primer on both sides. The basic substrate shall be Gr-120 hot dip Galvanized steel. The panels shall be made by continuous line and shall be joined together by means of tongue and groove joints system. The joints shall be made totally air tight by using proper sealant. The PUF panels shall be closed shall content of 90%-95% thermal conductivity of 0.023 at 10 0C (W/mk), compressive strength of 2.1 kg/m2 (at 10% deformation), water vapour permeability of 0.08-0.12 g/h/m2 , self-extinguishing property. The job shall include providing and fitting of U-Channels inner corners flashing, outer corner flashing, hold fasteners, screws silicon sealant and PU foam etc as per requirement at site. All the tools and tackles required during execution of job shall be arranged and brought to site by the firm and other items deemed to be fit for the job is included in the job. |
| 10 | Providing and fixing in position water proof wooden 12mm thick Ply to Ply layered plywood of approved make in the interior on top, bottom, sides of shed including wooden lipping, suitable locking arrangement, all types of screws, fasteners, hinges / piano hinges, wooden screws, adhesives, tower bolts, door handles/ knobs and all other types of necessary fittings etc. complete as per design, drawing and site condition as directed by the Engineer-In-Charge. |
| 11 | Supply, installation, testing of UPS for ETP of rated capacity 1600 W of reputed make of following specifications1. Rated capacity 1600VA2. Battery type SMF3. Output voltage 230VAC4. Recharge time 6Hrs to 90%5. Voltage 12V6. Number of batteries 02. All the tools and tackles required for the execution of job and other items deemed to be fit for the job is included in the job. |
| 12 | Providing and fitting of wall mounted fan of 20” standard size to the shed. |
| 13 | Providing and fitting of 9”x9” exhaust fan to the shed. |
| 14 | Providing and fitting of 100A, side operated change over switch of reputed make. The change over switch shall be operative on 415V+10%, 50 Hz+2%, 3Ø, 4-pole with SS enclosure of proper thickness as per IS and powder coated. The changeover switch shall be fitted on the wall with proper nuts and bolts of suitable size. The job also included providing/fitting/crimping and taping of the thimbles of required size & rating to the incoming and outgoing cable ends. Testing the changeover switch on full load. All the tools & tackles required for the execution of job have arranged & brought to the site by the contracting agency |
| 15 | Providing / Fitting of 3.5 core, 50 sqmm armoured Al cable for connecting power source to servo stablizer to Change Over panel and Bus bar. |
| 16 | Providing and Fixing of PVC soil waste/vent pipes with all accessories such as bends , collars clamps, elbows, reducers, junction, Door bends etc as per site requirement complete. a. 3\\" Dia. SWPVC |
| 17 | Providing, laying & fitting lighting point in 1.5 mm² size, multistrand, PVC insulated flexible copper conductor and is to be carried through PVC conduits/channels fixed to walls by means of clamps and other accessories. The job also includes providing and fitting of 12W LED lump, lump holder and 6A ON/OFF switch and other items deemed to be fit for the job. |
| 18 | Providing and fitting of fan regulator switch. |
| 19 | Providing, laying & fitting heating point complete with 20 Amp. Five way SS combine in 4 mm² size, multistrand, PVC insulated flexible copper conductor and is to be carried through PVC conduits/channels fixed to walls by means of clamps and other accessories or as deemed to be fit as per directions of site incharge. |
| 20 | 31.38-Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of “L” shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge.---Dimensions of size 1”x1” 12gauge(2.68mm) Please Enable Macros to View BoQ information |