| 1 | Rates for Retrofitting of Kuriya Gaon Water Supply Scheme including supply of all material, labour, T&P etc. complete.within Jal Jeevan Mission program under Haldwani Block. |
| 2 | E & M Work & Accessories |
| 3 | Lifting/lowering of 150 mm dia. Column pipe with supply and fixing including nut bolt, rubber packing, submersible cable jointing and NRV repair complete in all respect including cost of materials with all T&P required. |
| 4 | Repairment of fully automatic pump automation control pannel of suitable for 1000 lpm 210 m head capacity having intelegent unit having\\" FIELD PROGRAMMABLE LOGIC CONTROLER based SCADA operated pump motor startRun Control Protactagainst faults automatically operated controle and management system\\" for supervisory control and data acquasition system at pumping water supply schemes & two year freeof cost AMC for warranty period of following dutiesas per specifications sheet enclosed &suaitable for integrationsin the existing system including cartage from works of manufactures up to site of work Capacity of suitable for 1000 lpm 210 m. |
| 5 | Supply and fixing of 400 Amp TPN main switch 3 phase, 415 volt, 50 H havells make heavy duty double break main switch with HRC fuse making connection at this testing complete work etc at inter college tubewell. |
| 6 | Main piping and valves as per specification. |
| 7 | Supply of 150mm dia Column pipe, 6.4 mm thick - |
| 8 | Supply and fixing of suitable 16 mm thick MS Flange for column pipe both end with fixing trangle support and cutting of groove for cable all complete with labour& T&P |
| 9 | 150mm dia size column pipe clamps. |
| 10 | Distribution of Pipe line work |
| 11 | Providing, Lowering into trenches with true to alignment, Laying & Jointing of full lenghts of HDPE Pipes of specified grade as per IS:4984-1995 and specifications, with testing of pipe line including supply of jointing materials. HDPE Pipe Confirming to IS: 4984-1995/ PE-100 Grade Normal Pressure (PN) in 6.0 Kg/Cm263 mm dia |
| 12 | 75 mm dia |
| 13 | 90 mm dia |
| 14 | 110 mm dia |
| 15 | 140 mm dia |
| 16 | 200 mm dia |
| 17 | Excavating in soil mixed with single boulders etc. requiring the use of specials T&P, if any, for pipe line trenches including lift up to 50m and lead upto 30m with back filling, watering, ramming of excavated earth in the trenches.(0.6 +dia)(1.0+dia) |
| 18 | Supplying and fixing of following sizes of valves including carting the same upto site of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect but excluding the cost of earth work and construction of chamber. C.I. D/F sluice valves confirming to IS: 14846-2000200 mm dia |
| 19 | 125 mm dia |
| 20 | 80 mm dia |
| 21 | 65 mm dia |
| 22 | 50 mm dia |
| 23 | Constructing masonry Chamber , inside with 75 class designation brick work in cement mortar 1:4(1 cement: 4 coarse sand ) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : - With F.P.S. bricks.90x90x100 |
| 24 | 60x60x75 |
| 25 | Supply and Installation of Fire Hydrant including supply of all fasting & fixture Item, Construction of Chamber size 60x60x100 Cms. Complete in all respect. |
| 26 | Demolishing cement concrete manually/ by mechanical means incl- uding disposal of material within 50 metres lead as per direction of Engineer - in - charge. - for CC road |
| 27 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.-For Reinstatement |
| 28 | Providing and Fixing Ultrasonic Water flow meter for bulk pipe lines inline type, flange end with integral mounted, flow rate &totaliser display, battery operated (with five year battery life ) Communication:UART/RS485, suitable against antifraud attempts etc. incl. all necessary fittings complete. 80 mm |
| 29 | 125 mm |
| 30 | 200 mm |
| 31 | FHTC (Functional Household Tap Connection) |
| 32 | Excavation in soil mixed with single bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches.15 mm dia GI Pipe |
| 33 | Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete.15 mm dia GI Pipe |
| 34 | Making ferrule connection in the existing main of G.I, A.C, PVC or any type of pressure mains with saddle piece, service connections, fittings and fixing of G.M. ferrule including tapping the main, but excluding the cost of earth work and cost of all materials. Ferrule Connection (Labour cost only) |
| 35 | Cost of Material for ferruling in FHTC per connection as Lump Sum Please Enable Macros to View BoQ information |