| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 2 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : a) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for : a) Shelves (Cast in situ) |
| 4 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. A) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. A) 40 mm thick with 20 mm nominal size stone aggregate |
| 7 | 12 mm cement plaster of mix : a) 1:6 (1 cement: 6 fine sand) |
| 8 | 15 mm cement plaster on the rough side of single or half brick wall of mix : a) 1:6 (1 cement: 6 fine sand) |
| 9 | 12 mm cement plaster finished with a floating coat of neat cement of mix : a) 1:3 (1 cement: 3 fine sand) |
| 10 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : a) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : a) Two or more coats on new work. |
| 12 | Finishing walls with Acrylic Smooth exterior paint of required shade : a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 13 | Finishing walls with Acrylic Smooth exterior paint of required shade : a) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |
| 14 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. A) Old work (one or more coats) |
| 15 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : a) One or more coats on old work. |
| 16 | Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : a) 100 mm diameter pipes . |
| 17 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). a) Sal wood |
| 18 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) i) Kiln seasoned selected planks of sheesham wood a) 35 mm thick shutters |
| 19 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. a) Kiln seasoned and chemically treated hollock wood. |
| 20 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 21 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : a) 125 mm |
| 22 | b) 100 mm |
| 23 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade with necessary screws etc. complete. A) Twin rubber stopper |
| 24 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : a) 250x10 mm |
| 25 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : a) 300x16 mm |
| 26 | b) 250x16 mm |
| 27 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 28 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. A) Using M.S. angels 40x40x6 mm for diagonal braces |
| 29 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 30 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 31 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. A) 110 mm diameter |
| 32 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. i ) Single tee with door (a) 110x110x110 mm |
| 33 | (ii) Bend 87.5° (a) 110 mm bend |
| 34 | Providing and fixing unplasticised -GI pipe clips of approved design to unplasticised - PVC rain water pipes by means of hardwood plugs/Pvc gugay, screwed with M.S. screws of required length including making good the wall etc. complete. As Per Direction of EICa) 110 mm |
| 35 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 36 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead : a) With cement mortar 1:4 (1cement: 4 coarse sand). |
| 37 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: a) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 38 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. a) Orissa pattern W.C Pan of size 580x440 mm |
| 39 | Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. |
| 40 | Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts / welding and erection etc. complete. A) Wheel 50 mm dia. and below. |
| 41 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 42 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish to muncipal dumpaning yard outside the periphery of the area cleared. |
| 43 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. A) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 44 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 45 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 46 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : a) Of area 3 sq. metres and below |
| 47 | b) Of area beyond 3 sq. metres |
| 48 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 500 m initial lead, for all leads including all lifts involved. |
| 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall a) 20 mm nominal outer dia. Pipes. |
| 50 | b) 25 mm nominal outer dia .Pipes. |
| 51 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall. A) 20 mm dia. nominal bore |
| 52 | b) 25 mm dia. nominal bore |
| 53 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : a) 25 to 40 mm nominal bore |
| 54 | Providing and fixing uplasticised PVC connection pipe with brass unions : a) 30 cm length 15 mm nominal bore |
| 55 | Providing and fixing PTMT bib cock of approved quality and colour. A) 15mm nominal bore, 90 mm long. Weighing not less than 93 gms. |
| 56 | Providing and fixing PTMT grating of approved quality and colour. A) Circular type. 100 mm nominal dia. |
| 57 | Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. |
| 58 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : a) 25 mm nominal bore |
| 59 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: a) White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 60 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 61 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. A) 10 litre capacity - White |
| 62 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (i) Flexible pipe (a) 32 mm dia |
| 63 | Grading roof for water proofing treatment with a) Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 64 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 65 | After cleaning of roof slab and proper curing applying cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. |
| 66 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge a) 75 mm average thickness |
| 67 | b) 50 mm average thickness |
| 68 | c) 25 mm average thickness |
| 69 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. a) Bars upto 12 mm diameter |
| 70 | b) Bars above 12 mm diameter |
| 71 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. A) Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make. |
| 72 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). a) 12 mm average thickness. |
| 73 | b) 25 mm average thickness in 2 layers. |
| 74 | c) 50 mm average thickness in 3 layers. |
| 75 | Repairing the minor crack portion in the Brick wall with arrangement of provision for nailing the chiken mesh jali and making good the same with cement plaster 1:4 (1 cement : 4 coarse sand ) up to a thickness of 20mm as per instruction of Engineer in charge. |
| 76 | Uprooting Bargad/Jangali plants on vertiacal wall and on roof of bldg. taking out the root of plant from wall throgh chiesel the wall upto 2nd floor level including labour , material for repairs wall and treatment with acid in roots of plants etc. and repairing the same. All complete as per direction of E-I-C (Scafloding is payment basic item sepertely) |
| 77 | Easy adjusting of doors shutter (Aluminium, wood wherever necessary of fixing with screws,oiling,chesiling etc.complete as direction of Engineer in charge. |
| 78 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to 3rd story height made with bamboos 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with bamboos, bamboo challies, clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners,connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 79 | Cleaning of M/H by manually labour with bamboo's stick & gunny bag upto complete satisfaction of Engineer in charge.( including the rate of dumping the night soil to the municipal dumping ground etc.) |
| 80 | Providing and fixing PVC water tank cover i/c locking arrangement existing water tank as per direction of EIC |
| 81 | Credit of old and damaged steel Grill/TMT bar/steel window/steel door frame /GI Pipe other iron material etc as per local market rate as per direction of Engineer in charge.(i/c all rate of loading/unloading/transportaion etc) Please Enable Macros to View BoQ information |