Housing Urban and Rular Development Local Bodies Closing in 5 days TDR #56146073

Tender For Strengthening Of Sewerage (Replacement Of Old Chocked & Damaged Sewer & Water Line In Village-Barolla Noida.

Issued by Local Bodies · Ghaziabad, Uttar Pradesh
Tender Value
3.72 Crore
Estimated cost
Bid Submission
07 Jul 2026
5 days left
EMD
8.79 Lakhs
Bank guarantee accepted
Document Fee
5310
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Strengthening Of Sewerage (Replacement Of Old Chocked & Damaged Sewer & Water Line In Village-Barolla Noida.

BOQ

Name of Work:- Strengthening of Sewerage (Replacement of Old Chocked & Damaged Sewer & Water line in Village-Barolla Noida.
Sl. No. Item Description
1Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
2Earth work in excavation by mecanical means (hydraulic excavater)/manual means in over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) i/c disposal of excavated earth, lead up to 50 m and lift up 1.5, disposed earth to be levelled and neatly dressed in all kind of soil.The contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of E/I.
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m.
4Extra for every additional lift of 1.5 or part thereof in all kind of soil.
5a) 1.50 - 3.00 m
63.00-4.50m
7Centring and shuttering including strutting, propping etc. and removal of form for:-
8a) Foundation, footings, bases of columns etc. for mass concrete.
9Cement Concrete with 4 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work.
10As in item 279 above but in proportions of 8:4:1
11P/L in position Cement Concrete of specified grade excluding the cost of centering and shuttering – all work up to plinth level :
121:2:4 (1 Cement : 2 C. Sand (zone-cum III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).
13P/L Non-Pressure NP-3 class RCC Spigot Socketed pipe confirming to IS : 458 : 2003 with latest amendment laying in true alignment & position on craddle including with rubber ring (confirming to IS : 5382 with latest amendment testing of laid pipe as per direction of Engineer Incharge complete in all respect.
14300 mm dia Sewer pipe
15400 mm dia Sewer pipe
16450 mm dia Sewer pipe
17600 mm dia Sewer pipe
18Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top with 100 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 C.Sand), in side cement plaster 12mm thick with cement mortar 1:3 (1 cement: 3 c.sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement: 3 c.sand: 6 graded stone agg. 40mm n.s.), and making necessary channel in cementconcrete 1:2:4 (1 cement: 2 coarsesand : 4 graded stone agg. 20 mm n.s.) finished with a floating coat of neat cement all complete as per standard design. 0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement: 2 c.sand: 4 graded stone agg. 20mm n.s) including centering shuttering all complete. (Excavation, foot rests and 12m thick cement plaster at the external surface shall be paid for separately). with common burnt clay F.P.S. (non modular) bricks of class designation 100.
19Extra depth for circuler type manhole 0.91 m internal dia (at bottom) beyond 0.91 m to 1..67 m. With common burnt clay F.P.S. (non modular) bricks of class designation 100.
20Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 Cement : 4 C. Sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 Cement : 3 C. Sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 Cement : 3 C. Sand : 6 graded stone agg. 40 mm n.s.), and making necessary channel in cement concrete 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20 mm n.s.) finished with a floating coat of neat cement, all complete as per standard design. 1.68 m deep with SFRC cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS : 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 Cement : 2 C. Sand : 4 graded stone agg. 20mm n.s.) i/c centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately). with common burnt clay F.P.S. (non modular) bricks of class designation 100.
21Extra depth for circuler type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m. With common burnt clay F.P.S. (non modular) bricks of class designation 100.
22Constructing brick masonry circular type manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 Cement : 3 C. Sand : 6 graded stone agg. 40 mm n.s.), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nomonal size.) finished with a floating coat of neat cement all complete as per standard design.0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS : 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) i/c centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately). With common burnt clay F.P.S. (non modular) bricks of class designation 100.
23Extra depth for circuler type manhole 1.52 m internal dia (at bottom) with common burnt clay F.P.S. (non modular) class designation 100 beyond 2.30 m
24Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 c.sand: 4 graded stone agg. 20 mm n.s) cement plastered on both sides with cement mortar 1:3 (1cement: 3 c.sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete
25For Pipes 250 to 300 mm dia
26For Pipes 350 to 450 mm dia
27Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactrue's permanent identification mark to be visible even after fixing, i/c fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 Cement : 3 C. Sand : 6 graded stone agg.20 mm n.s.) complete as per design.
2812 mm cement plaster of mix 1:4 (1 Cement : 4 C. Sand).
29Hiring of Diesel Enginr (including cost of Diesel, lubricant & Operator).
30Disposal of building rubbish/malba/similar unserviceable dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by E/I, beyond 50 m initial lead, for all leads including all lifts involved.
31Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vaccum dewatering process and finally finished by floating, brooming with wire brish etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
32Excavating trenches of required width for pipes, cables etc. i/c excavation for sockets depth upto 1.5m i/c getting out the excavated materials, returning the soil as required in layers not exceeding 20cm. in depth i/c consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within lead of 50 m. The contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of E/I.
33a) Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm dia.
34P/L following size of Finolex makes PVC pipes 6 Kg/Cm2 with required PVC standard special confirming to IS codes with latest amendment and lowering the same trenches and laying true to alignment and gradient complete I/c the cost of cutting of pipes for making upto length and making joints I/c cost of socket, plstochem PV-85 PVC solvent cement complete. PVC pipe must be confirming to IS : 4985-2000 with latest amendment Make-Finolex Industries Ltd. /Kisan/Supreme industries Ltd. (Rate As per Comparative Statement per Rm.)
35a) 140 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVCstandard Specials
36b) 160 mm dia with coupler @ 6 Kg/Cm2 Pressure with i/c all PVCstandard Specials
37Providing & fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of E/I. (external work).
3815 mm nominal outer dia Pipes
39P/F M.S. Clamp.
40P/F M.S. Clamp 140 mm dia i/c excavation, reffiling etc. complete as per direction E/I.
41P/F M.S. Clamp 160 mm dia i/c excavation, reffiling etc. complete as per direction E/I.
42P/F M.S. Clamp 200 mm dia i/c excavation, reffiling etc. complete as per direction E/I.
43Reparing of existing PVC water line I/c bailing out of water by / Manually / Diesel Engine, P/F PVC coupler, CID joint etc. complete work as per direction of E/I (But Excluding cost of excavation filling and PVC pipe)
44a) 110 mm dia PVC line
45b) 140 mm dia PVC line
46c) 160 mm dia PVC line
47d) 200 mm dia PVC line
48Supply of PVC pipe 6Kg/cm2 pressure with required PVC standard special confirming to IS : 4985-2000 with latest amendment Make- Finolex Industries Ltd./Kisan/Supreme Industries Ltd. (Rate as per comparative statement per Rm.)
49a) 110 mm dia with coupler @ 6 Kgf/Cm2 Pressure
50b) 140 mm dia with coupler @ 6 Kgf/Cm2 Pressure
51c) 160 mm dia with coupler @ 6 Kgf/Cm2 Pressure
52d) 200 mm dia with coupler @ 6 Kgf/Cm2 Pressure
53P/F M.S. Special such Tee, Bends, collars, Tapers cap pieces pipes including flange ends as required painting, cutting, welding as per site requirement of MS pipe thickness etc. complete in all respect as per the direction of E/I.
54Hiring of Gas cutting Set with oxygen and LPG Running Time @ 6 Hrs.
55Hiring of Welding Set Running Time @ 6 Hrs
56Hire charge of Generator (including cost Service of operating staff, supply of lubriceting oil and diesel also)
57DG Set/Generator 50 KVA
58Reparing existing AC/CI/DI Water line I/call required materials such as CID joints, rubber packing, nut & bolts, bailling out of water, all labour and T&P i/c cutting of pipe etc. complete work as per direction of E/I (But Exclyding cost of Excavation filling and M.S. Special)
59200 mm dia.
60250 mm dia. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56146073
AUTHORITY Local Bodies
TENDER VALUE 3.72 Crore
LAST DATE 07-07-2026
Authority
Authority Name New Okhla Industrial Development Authority
Work Description Tender for Strengthening Of Sewerage (Replacement Of Old Chocked & Damaged Sewer & Water Line In Village-Barolla Noida.
Basic Detail
Tender No 19/SM-JAL-III/2026-27
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 24 Jun 2026
Submission Date 07 Jul 2026
Open Date 08 Jul 2026
Finance
Tender Value 3.72 Crore
Tender Fee 5310
EMD 8.79 Lakhs
Exemption Not Available
Document List
4e39e95f-3517-4c57-a8bd-43154787f2e8.html
BOQ_2181158.xls
C19.xls
TD19.pdf
Tendernotice_1 (23).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

4e39e95f-3517-4c57-a8bd-43154787f2e8.html

xls

BOQ_2181158.xls

xls

C19.xls

pdf

TD19.pdf

pdf

Tendernotice_1 (23).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail