| 1 | Detailed condition assessment reportPreliminary visual inspection & surface survey, high-resolution photographic documentation (before, during and after), condition mapping (deterioration marking, tracing/ grid mapping), material & deterioration identification (visual analysis), written condition assessment report with recommendations in detailed project report in coordination with qualified art conservator and conservation architect on site. |
| 2 | Photographic and videographic documentation Providing comprehensive pre-conservation photographic documentation of historic wall paintings including overall elevations, sectional views, and close-up condition details using high-resolution digital equipment, with proper scaling, color reference, and controlled lighting, complete as per conservation documentation standards. Carrying out systematic videographic recording of wall paintings, preparation of detail condition photographs highlighting deterioration features such as flaking pigments, cracks, plaster detachment, deposits, and previous repairs, properly indexed and labeled. |
| 3 | Proper handling and moving health and safety measuresProviding and maintaining site-specific health and safety arrangements for wall painting conservation works, including hazard assessment, safe work procedures, and compliance with heritage-site safety protocols, complete. |
| 4 | Conservation laboratory at siteProviding and installing a temporary conservation laboratory/workstation at site, including stable work tables, storage racks, and protected preparation area for conservation materials, complete in all respects. Provision of basic examination equipment such as magnification lamps, raking light, PH meter and other necessary equipment, measuring tools, and accessories required for wall painting conservation. All chemicals and consolidate must be of conservation grade imported chemical with bills and available on site. |
| 5 | Scientific analysis/ testing from authorized laboratry of wall painting as per conservation requirements. Carrying out non-destructive scientific examination of wall paintings to identify materials, pigments, binders, and deterioration features using approved analytical methods. |
| 6 | Consolidation of plaster and paint layer as emergency treatmentCarrying out emergency condition assessment to identify unstable areas of wall paintings including flaking pigments, detached plaster, cracks, or active deterioration requiring urgent stabilization. Providing temporary facing/support using conservation-grade tissue, reversible adhesives, stabilization of loose edges, cracks, or localized detachments through minimal intervention techniques suitable for historic fabric. CleaningCarrying out pre-cleaning examination and test patches to determine suitable cleaning methodology compatible with original materials, gentle dry surface cleaning using soft brushes, micro-vacuum, or conservation-grade tools to remove loose dust and deposits without disturbing original paint layers, controlled wet/chemical cleaning using approved conservation solutions, swabs, or gels and localized cleaning of sensitive or fragile areas using minimal intervention techniques.Filling and filleting Preparation of lacunae and edges by careful cleaning and stabilization of surrounding original plaster and paint layers prior to filling operations. Providing compatible lime-based or conservation-grade filling to losses in plaster, cracks, and voids, matched in texture and level to adjacent surfaces without covering original paint layers. Executing filleting of edges to secure fragile boundaries between original material and fills using fine tools and reversible conservation materials.In painting and reintegrationCarrying out inpainting of losses using reversible, conservation-grade pigments and binders to visually integrate lacunae without covering original historic material. Executing chromatic reintegration using distinguishable conservation techniques (e.g., tratteggio/ neutral toning) to achieve visual harmony at normal viewing distance while remaining identifiable upon close inspection.Reattachment of loose elementsIdentification and marking of hollow or detached plaster areas through careful tapping and visual inspection prior to treatment, preparation of injection points and cleaning of voids to facilitate bonding without disturbing original paint or plaster layers. Injection of compatible lime-based or conservation-grade grouts/adhesives to reattach loose plaster to the substrate using controlled methods and pressure and sealing and finishing of injection points to match surrounding surface without obscuring original fabric.Stabilization of paintingApplication of compatible conservation-grade consolidants to stabilize flaking or powdering paint layers using controlled methods to ensure penetration without altering appearance and proper protective coat to wall painting using conservation grade consolidant.Recommendations for preventive conservation, scheduled training to staff and care taker of building. |
| 7 | Recreation of new painting on existing wooden doors/ windowsCleaning of existing paint layer as per requirement on site under supervision of Engineer in-charge.Local repair or replacement of deteriorated wooden elements with matching seasoned timber, ensuring protection and reintegration of painted surfaces.Complete painting decoration work on wooden doors / windows & false ceilings.Treatment for insect or biological activity using conservation-approved methods safe for painted surfaces.Application of protective measures and environmental stabilization during conservation work. |
| 8 | Restoration of existing decorative wooden doors/ windowsDetailed inspection, condition mapping, and photographic documentation of painted khatambandi ceiling including identification of paint loss, flaking, insect damage, structural looseness, and previous repairs, complete. Controlled wet/solvent cleaning tests and treatment, Stabilization and consolidation of flaking or powdering paint layers using compatible, reversible conservation materials.Local repair or replacement of deteriorated wooden elements with matching seasoned timber, ensuring protection and reintegration of painted surfaces.Minimal inpainting and visual reintegration of paint losses using reversible pigments, ensuring distinguishability on close inspection.Treatment for insect or biological activity using conservation-approved methods safe for painted surfaces.Application of protective measures and environmental stabilization during conservation work. |
| 9 | Providing and fixing of new Khatambandi at ceiling in Chaar-gul pattern fabricated using 1st class seasoned Deodar wood. The rate shall include supply, workmanship and installation of wooden ceiling components excluding scaffolding/ framework. |
| 10 | Restoration of painting on decorative khatam BandiDetailed inspection, condition mapping, and photographic documentation of painted khatambandi ceiling including identification of paint loss, flaking, insect damage, structural looseness, and previous repairs, complete. Controlled wet/solvent cleaning tests and treatment, Stabilization and consolidation of flaking or powdering paint layers using compatible, reversible conservation materials.Structural tightening and stabilization of interlocking wooden members.Local repair or replacement of deteriorated wooden elements with matching seasoned timber, ensuring protection and reintegration of painted surfaces.Minimal inpainting and visual reintegration of paint losses using reversible pigments, ensuring distinguishability on close inspection.Treatment for insect or biological activity using conservation-approved methods safe for painted surfaces.Application of protective measures and environmental stabilization during conservation work. |
| 11 | Recreation of new decorative painting on khatam BandiCleaning of existing paint layer as per requirement on site under supervision of Engineer in-charge.Structural tightening and stabilization of interlocking wooden members.Local repair or replacement of deteriorated wooden elements with matching seasoned timber, ensuring protection and reintegration of painted surfaces.Complete painting decoration work on wooden false ceilings.Treatment for insect or biological activity using conservation-approved methods safe for painted surfaces.Application of protective measures and environmental stabilization during conservation work. |
| 12 | Providing and fixing double scaffolding system (cup lock type) on the interior side of building/ structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. sqm 159.90 Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 13 | Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100gm/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (Onetime payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work) |
| 14 | Provide & fixing printed pvc based cross-hatch texture star flex over the barricade/ frame/ ms sheet /ply board for a height up to 20 m to separate the working area, including any fixing frame work of wood or ms tube upto 25x25 mm or as per direction of engineer incharge and removing the same after completion of the work . Please Enable Macros to View BoQ information |