Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #56142364

Tender For Repairs & Maintenance To C/F Pumps, Vt Pumps, Submersible Pumps Along With Connected Items Under Ge Nrc.

Issued by Statutory Bodies & Commissions/Committees · Nashik, Maharashtra
Tender Value
50 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
14 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs & Maintenance To C/F Pumps, Vt Pumps, Submersible Pumps Along With Connected Items Under Ge Nrc.

BOQ

Name of Work:- REPAIRS & MAINTENANCE TO C/F PUMPS, VT PUMPS, SUBMERSIBLE PUMPS ALONG WITH CONNECTED ITEMS UNDER GE NRC.
Sl. No. Item Description
1Notes for Entire Work:-(i) Water Supply being an essential service to MES, the work shall be completed within -02 Days of handed over by Dept ,else penelty of Rs.1,0000 per day shall be imposed.(ii) If the work shall not be completed within 10 Days, the work shall be cancelled and PSD submitted by the Contractor will be forefitted.
2Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep and getting out in soft loose soil all as specified and directed
3Returining, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed
4Removing excavated soil to a distance not exce 50 m and deposited where directed at a level not exceding 1.5 m abvoe the starting point all as specified and directed.
5M&L for taking out old rusted MS pipe line of size 300 mm by cutting with gas welding or any other means including Tees, bends, elbows etc complete all as specified
6M&L for Dismantling PCC (Thrist block) of any description andin any position for removal of MS pipes completed all as specified as as dircted
7Supply, laying & Jointing of ISI marked Mild Steel (ERW) flanged pipes 300 mm dia heavy duty (Class C) with 8 mm thickness including all fittings i.e. reducer, elbow, tees, flanges etc. including transportation material to site, jointing by welding providing coating, laying the pipes in tranches /on PCC blocks compele work in all respect all as specified and directed .Note : PCC & Earthwork shall be measured and paid seperatelyMake:- Tata/Jindal
8Cutting existing cast iron pipe 300 mm dia in position for insertion of new pipe/tees, branches etc.
9Cutting existing cast iron pipe 250 mm dia in position for insertion of new pipe/tees, branches etc.
10Cutting existing cast iron pipe 200 mm dia in position for insertion of new pipe/tees, branches etc.
11Cutting existing cast iron pipe 150 mm dia in position for insertion of new pipe/tees, branches etc.
12Cutting existing cast iron pipe 100 mm dia in position for insertion of new pipe/tees, branches etc.
13Taking up 300 mm dia CI water pipe mains incuding flanged rubber joints with spigot and socketed ends and lead joint including burning out joints and recovering lead.
14Taking up 250 mm dia CI water pipe mains incuding flanged rubber joints with spigot and socketed ends and lead joint including burning out joints and recovering lead.
15Taking up 200 mm dia CI water pipe mains incuding flanged rubber joints with spigot and socketed ends and lead joint including burning out joints and recovering lead.
16Taking up 150 mm dia CI water pipe mains incuding flanged rubber joints with spigot and socketed ends and lead joint including burning out joints and recovering lead.
17Taking up 100 mm dia CI water pipe mains incuding flanged rubber joints with spigot and socketed ends and lead joint including burning out joints and recovering lead.
18Supply and laying 300 mm dia DI pipes K-9 (tyton joint ) with spigot and socket ends centrifugally cast, Class LA, laid in trenches complete all as specified and directed.Note :- Excavation, Earthwork, DI fittings shall be measured and paid seperately under respective items.
19Supply and laying 250 mm dia DI pipes K-9 (tyton joint ) with spigot and socket ends centrifugally cast, Class LA, laid in trenches complete all as specified and directed.
20Supply and laying 200 mm dia DI pipes K-9 (tyton joint ) with spigot and socket ends centrifugally cast, Class LA, laid in trenches complete all as specified and directed.
21Supply and laying 150 mm dia DI pipes K-9 (tyton joint ) with spigot and socket ends centrifugally cast, Class LA, laid in trenches complete all as specified and directed.
22Supply and laying 100 mm dia DI pipes K-9 (tyton joint ) with spigot and socket ends centrifugally cast, Class LA, laid in trenches complete all as specified and directed.
23M&L for 300 mm dia run lead joints for water mains with spigot & socket pipes and fittings, all as specified and directed.
24M&L for 250 mm dia run lead joints for water mains with spigot & socket pipes and fittings, all as specified and directed.
25M&L for 200 mm dia run lead joints for water mains with spigot & socket pipes and fittings, all as specified and directed.
26M&L for 150 mm dia run lead joints for water mains with spigot & socket pipes and fittings, all as specified and directed.
27M&L for 100 mm dia run lead joints for water mains with spigot & socket pipes and fittings, all as specified and directed.
28M&L for 80 mm dia run lead joints for water mains with spigot & socket pipes and fittings, all as specified and directed.
29S&F 300 mm dia rubber tyton joint.
30S&F 250 mm dia rubber tyton joint.
31S&F 200 mm dia rubber tyton joint.
32S&F 150 mm dia rubber tyton joint.
33S&F 100 mm dia rubber tyton joint.
34S&F 80 mm dia rubber tyton joint.
35S&F 300 mm dia with 06 holes machanical joint / Coller ISI marked for spigot end pipe.
36All as per Itme No. 35.00 above but 250 mm dia with 06 holes
37All as per Itme No. 35.00 above but 200 mm dia with 06 holes
38All as per Itme No. 35.00 above but 150 mm dia with 04 holes
39All as per Itme No. 35.00 above but 100 mm dia with 04 holes
40All as per Itme No. 35.00 above but 80 mm dia with 04holes
41Taking up or down 15 mm dia GI tubing and connections including cleaning for refixing or sold under Sch of credit.
42Taking up or down 20 mm dia GI tubing and connections including cleaning for refixing or sold under Sch of credit.
43Taking up or down 25 mm dia GI tubing and connections including cleaning for refixing or sold under Sch of credit.
44Taking up or down 40 mm dia GI tubing and connections including cleaning for refixing or sold under Sch of credit.
45Taking up or down 50 mm dia GI tubing and connections including cleaning for refixing or sold under Sch of credit.
46Relaying of 15mm dia GI tube obtained from taking down, incl renewal of threading if required, fixed to walls or laid in floor or to be concealed wherever directed and jointing with new fitting such as socket, bends, elbows, union etc complete.
47Relaying of 20 mm dia GI tube obtained from taking down, incl renewal of threading if required, fixed to walls or laid in floor or to be concealed wherever directed and jointing with new fitting such as socket, bends, elbows, union etc complete.
48Relaying of 25mm dia GI tube obtained from taking down, incl renewal of threading if required, fixed to walls or laid in floor or to be concealed wherever directed and jointing with new fitting such as socket, bends, elbows, union etc complete.
49Relaying of 40 mm dia GI tube obtained from taking down, incl renewal of threading if required, fixed to walls or laid in floor or to be concealed wherever directed and jointing with new fitting such as socket, bends, elbows, union etc complete.
50Relaying of 50 mm dia GI tube obtained from taking down, incl renewal of threading if required, fixed to walls or laid in floor or to be concealed wherever directed and jointing with new fitting such as socket, bends, elbows, union etc complete.
51Supply and laying 15 mm dia GI tubing medium grade with all fittings and fixed complete laid in trenches/on wall/Ceiling.
52Supply and laying 20 mm dia GI tubing medium grade with all fittings and fixed complete laid in trenches/on wall/Ceiling.
53Supply and laying 25 mm dia GI tubing medium grade with all fittings and fixed complete laid in trenches/on wall/Ceiling.
54Supply and laying 40 mm dia GI tubing medium grade with all fittings and fixed complete laid in trenches/on wall/Ceiling.
55Supply and laying 50 mm dia GI tubing medium grade with all fittings and fixed complete laid in trenches/on wall/Ceiling.
56Supply and laid 150 mm dia spigot and socketed DI fittings such as bends (any type radius and angle), tapers, tees, collars, tail piece socket, flanged/spigot etc.
57Supply and laid 200 to 300 mm dia spigot and socketed DI fittings such as bends (any type radius and angle), tapers, tees, collars, tail piece socket, flanged/spigot etc.
58Area clearance/levelling/excavation /digging at MES installations at any width and length by using JCB complete all as directed.Note 1. The cost of POL included in quotated rates .2. After Start and finsh of the work hours slips shall be provided by the contrcator3. LOG Sheet shall be maintained duly signed by Engineer-in-Charge & JE.
59M&L for Earthing in replacement complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 m, all as per electric Plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.
60S&F galvannised strip 32x6mm with saddles and fixing screws etc. complete all as specified and directed.
61Taking out of centrifugal pump set 150 HP from pump foundation after disconnection from motor and transportation to workshop, dismantling the pump for repair/ overhauling including cleaning of all parts of pump assembly throughly, including machine work of pump shaft inorder to obtain smooth finish, necessary polishing etc and installing back, helium gasket sheet not less than 1mm thick complete all as specified and directed. Make -Kirloskar, DSM 150X45 Note:(i) Spares as required shall be measure & paid seperately against the relevant items as supply only(ii) T&P and transportation to workshop & return is included in quotated rates.
62(a) Supply only Casing Wear Ring-
63(b) Supply only shaft sleeve-
64(c) Supply only Inter Stage Ring-
65(d) Supply only Ball bearing SKF - 7310
66(e) Supply only Ball bearing SKF - 6310 C3
67(f) Supply only Bearing cartridge DE
68(g) Supply only Bearing cartridge NDE
69(h) Supply only shaft sleeve Nuts
70(j) Supply only Split Gland
71Taking out of centrifugal pump set 125 HP from pump foundation after disconnection from motor and transportation to workshop, dismantling the pump for repair/ overhauling incluiding cleaning of all parts of pump assembly throughly, including machine work of pump shaft inorder to obtain smooth finish including necessary polishing etc and installing back including helium gasket sheet not less then 1mm thick all as specified and directed.Make: Kirloskar, DSM 125X40 Note: (i) Spares as required shall be measure & paid seperately against the relevant items as supply only(ii) T&P and transportation to workshop & return is included in quotated rates.
72(a) Supply only Casing Wear Ring
73(b) Supply only shaft sleeve
74(c) Supply only Inter Stage Ring
75(d) Supply only Ball bearing SKF - 7309
76(e) Supply only Ball bearing SKF - 6309
77(f) Supply only Bearing cartridge DE
78(g) Supply only Bearing cartridge NDE
79(h) Supply only shaft sleeve Nuts
80(j) Supply only Split Gland
81M&L for taking up vertical turbine pump 175 HP/180 HP (Dharna Pump House) multi stage oil lubricated type B-350-9-200 from jack well after disconnection of electrical connection earthing lines and transportation to local workshop for repairs / overhaulling of pump including dismantling the assembly, cleaning all parts of pump assembly thoroughly and finding out the defects segregating the serviceable spare parts for reuse and including machine work, reassembling the pump set after successful repair and lowering to the existing position and refixing and testing complete all as specified and directed.Make Jyoti Ltd. Note:-(i) Spares as required shall be measure & paid seperately against the relevant items as supply only(ii) T&P and transportation to workshop & return is included in quotated rates.
82(a) supply only Impeller Holding Split ring CI
83(b) Supply only Bowl bearing - Bronze
84(c) Supply only Top Bowl bearing - Bronze
85(d) Supply only Lantern ring
86(e) Supply only Impeller shaft packing ring - Bronze
87(f) Supply only Discharge case bearing - Bronze
88(g) Supply only Impeller shaft coupling - AISI410
89(h) Supply only Line shaft bearing Bronze
90(j) Supply only Glide spider - CI
91(k) Supply only Rubber guide ring - STD
92(l) Supply only Rubber guide ring Circlip - STD
93(m) Supply only Gland packing - STD
94(n) Supply only Gland packing ring - Aluminium
95(o) Supply only Impeller with seal ring Bronze
96(p) Supply only motor rachet
97M&L for taking up submersible pump 20 HP multi stage Model No B 93/1 from well after disconnection of electrical connection and transportation to local workshop for repairs / overhaulling of pump including dismantling the assembly, cleaning all parts of pump assembly thoroughly and finding out the defects segregating the serviceable spare parts for reuse and including machine work, reassembling the pump set after successful repair and refixing to the existing position and testing complete all as specified and directed.Make: Amrut Note:-(i) Spares as required shall be measure & paid seperately against the relevant items as supply only(ii) T&P and transportation to workshop & return is included in quotated rates.
98(a) Supply only Spacer Sleeve
99(b) Supply only Top Sleeve
100(c) Supply only Lock Washer
101(d) Supply only Thrust Washer
102(e) Supply only Bearing Sleeve for Bowl / machanical seal
103(f) Supply only Bearing Bush GM for Bowl l / machanical seal
104(g) Supply only Neck Ring (Wear Ring)
105(h) Supply only Oil Seal
106(j) Supply only Bearing Bush GM for IP/l / machanical seal
107Taking up Submersible Pump assembly including column pipe approx 50 to70 m using chain pulley block manually and carrying out following phase of work all as directed for 5HP/3 HP/1 HP Pump Set.(i) Transportation of submersible pump motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3 phase, taking out burnt winding wire, rewinding using super enamelled copper winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed.(iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 5 HP submersible pump of any make including carrying out painting by two coat of synthetic enamelled paint over a coat of primer, assembling the pump and motor including testing complete.Note:-(i) Spares as required shall be measure & paid seperately against the relevant items as supply only(ii) T&P and transportation to workshop & return is included in quotated rates.
108(a) Supply only Impeller key
109(b) Supply only Lantern ring
110(c) Supply only Impeller shaft ring
111(d) Supply only thrust Ball bearing SKF
112(e) Supply only Water Seal
113(f) Supply only Motor pump couple bush with key
114(g) Supply only Impeller
115Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Volts, 50 Cycles, and taking out to local workshop induction motor 175 HP/180 HP for repair purpose including complete cleaning, varnishing, reinsulation and replacement of DE /NDE bearings and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note:-(i) T&P and transportation to workshop & return is included in quotated rates(ii) Rewinding will be measure & paid seperately under relavant item of Sch.
116Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Volts, 50 Cycles and taking out to local workshop submersible induction motor 20 HP for repair purpose including complete cleaning, varnishing, insulation, replacement of DE /NDE bearings and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note:-(i) T&P and transportation to workshop & return is included in quotated rates(ii) Rewinding will be measure & paid seperately under relavant item of Sch.
117Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Volts, 50 Cycles and taking out to local workshop induction motor 150/125/110/100 HP for repair purpose including complete cleaning, varnishing, insulation replacement of DE /NDE bearings and greasing and including shifting back to location as directed, installing, testing and commissioning after repair complete all as specified and directed.Note: Rewinding will be measure & paid seperately under relavant item of Sch.
118Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Volts, 50 Cycles and taking out to local workshop induction motor 15/10 HP/7.5 HP 1440 RPM for repair purpose including complete cleaning, varnishing, insulation replacement of DE /NDE bearings and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note:-(i) T&P and transportation to workshop & return is included in quotated rates(ii) Rewinding will be measure & paid seperately under relavant item of Sch.
119Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Volts, 50 Cycles, 5 HP, 900 RPM capacity motors from respective non clogging centrifugal pumps/open well submersible pumps, other rotating mechanism etc, removing from foundations, dismantling rotor and stator, bearings, cleaning the dust/dirt, overhauling thoroughly including complete varnishing and reinsulation replacement of DE/NDE bearings, greasing, reassembling the motor, mounting on the foundations, coupling with non clogging centrifugal pumps/respective mechanism, making the electrical connections, testing and commissioning all as directed. Note:-(i) T&P and transportation to workshop & return is included in quotated rates(ii) Rewinding will be measure & paid seperately under relavant item of Sch
120Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Volts, 50 Cycles and taking out to local workshop induction motor 3HP/1 HP 1440 RPM for repair purpose including complete cleaning, varnishing, insulation replacement of DE /NDE bearings and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note: Rewinding will be measure & paid seperately under relavant item of Sch.
121M&L for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations for the Pump 175/180 HP at Dharna pump House as directed.Note: T&P and Transportation requried included in the Quatod Rate
122M&L for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations for the Pump 150 to 100 HP at Waldevi pump House as directed.Note: T&P and Transportation requried included in the Quatod Rate.
123M&L for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations for the Pump 20 to 3 HP at Arty centre as directed.Note: T&P & Transportation requried included in the Quatod Rate.
124S&F in repair Contactor MNX140 160A U 1000V with Auxiliary contact ie AC-15:4A, 415V suitable for use on a circuit capable of delevering not more than 1000 RMS Symmetrical Ampre 600 Volts max fuze 225 A RK5 time delay type.Make : L&T or Equivalent in SIEMENS/ABB
125S&F in repair Fully Automatic Star Delta Motor starter 3 phase 66 150 HP MN 140 FASD in sheet-steel enclosure type MK-1S (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-14 and taking down.Make : L&T or Equivalent in SIEMENS/ABB
126Dismantling/Removing of Air compressor after disconnecting all electrical connetions and removing nuts & bolts etc, from foundation. Dismantling the compressor head, removing all defective parts as appended below, taking of compressor head, reassembling the compressor head after replacement of head gasket and other defective parts, as required including cleaning, servicing and overhauling the compressor. Reinstallation, commissioning and testing complete and replacement of compressor oil, all as specfied and directed. Make ELGI Capacity 10 Kg/Cm2Note:-(i) Spares as required shall be measure & paid seperately against the relevant items as supply only(ii) T&P and transportation to workshop & return is included in quotated rates
127(a) Supply only Piston Ring - 04 Nos
128(b) Supply only Bush Bearing - 02 Nos
129(c) Supply only Connecting rod bush - 02 Nos
130(d) Supply only Piston Pin - 02 Nos
131(e) Supply only Scrapper Oil Ring - 04 Nos
132(f) Supply only Piston - 02 Nos
133(g) Supply only Safety Valve - 01 Nos
134(h) Supply only Piston Pin bush - 02 Nos
135(i) Supply only Fan belt - 02 Nos
136S&F in repair MCCBs of 800 Amps 4 pole 50 kA, frame size SKB-3 adjustable thermal setting 70-100% Model No -I830416 (L&T) as directed.
137S&F in repair MCCB 400 Amps 4 pole 50 kA, Conforms to IS/IEC 60947 -2 as directed.
138S&F in repair MCCB 250 Amps 4 pole 50 kA, Conforms to IS/IEC 60947 -2 as directed.
139S&F in repair 100mm dia valve operating wheel cap (Cast iron) inserting of nut bolt with 20 mm GI pipe length 4 m long with Tee rod.
140S&F in repair 150mm dia valve operating wheel cap (Cast iron) inserting of nut bolt with 20 mm GI pipe length 4 m long with Tee rod.
141S&F in repair 200mm dia valve operating wheel cap (Cast iron) inserting of nut bolt with 20 mm GI pipe length 4 m long with Tee rod.
142Collecting samples of water from waldevi filteration plant / OH tanks inside the Arty centre/waldevi RAW water UG sump in sterlized bottle and testing is per IS 10500:2012 and upto latest revision for Organic & physical parameters, odour, PH, TDS, Turbidity, all substances undesirable in excessive at Distt Public Health laboratory Nashik /Govt lab and submitting test report all as directed
143M&L for rectification of water lekage pipe line size upto 80 mm to 300 mm pipe of any type (CI/GI/DI) including necessary excavation, joints, pipes etc all as specified and directed.Note : Excavation and eartwork, fittings, pipe etc shall be measured and paid under respective items of Schedule.
144NOTE: AMOUNT OF SCHEDULE OF CREDIT Rs. 5,32,535.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56142364
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 50 Lakhs
LAST DATE 15-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs & Maintenance To C/F Pumps, Vt Pumps, Submersible Pumps Along With Connected Items Under Ge Nrc.
Basic Detail
Tender No GE/NRC/8798/E8
Bidding Type Tender
Location
City Nashik
State Maharashtra
Key Dates
Publish Date 24 Jun 2026
Submission Date 15 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 50 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Available
Document List
Tendernotice_1 (1).pdf
3ae4370e-e47e-4410-b6da-707516e79bb9.html
8798PS.pdf
8798SOC.xls
BOQ_867143.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1 (1).pdf

html

3ae4370e-e47e-4410-b6da-707516e79bb9.html

pdf

8798PS.pdf

xls

8798SOC.xls

xls

BOQ_867143.xls