| 1 | Excavating in trenches, n.exc 1.50m wide and n.exc 1.50m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil complete all as specified and directed. |
| 2 | M&L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggragated) as in foundation filling and mass concrete, sub base of floor, sub base of path etc complete all as specified and directed |
| 3 | M&L for brick work with flyash bricks straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed. |
| 4 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick wk or concrete surfaces surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | Returning filling in soil including spreading leveling watering and well ramming in layers not exc. 25mm thick each complete all as specified and directed. |
| 6 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 7 | M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggragate) as in benchning, copings, channels, slightly chamfered or rounded on edge including necessary use of form work complete all as specified and directed. |
| 8 | S&F mild steel TMT bars as in reinforcement ,6mm to 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 9 | S&F framed steel work for doors, gates and posts using angle iron or other rolled steel sections, including gusset plates, rails, braces, cleats and other necessary members, complete, drilled and prepared for fixing steel sheeting or other covering. Doors and gates shall be prepared for hinged or sliding operation, including hooks, hinges or steel hanging door fittings, fastening and fixing in position, fabricated from Fe-410W (Grade E-250) Quality B steel complete all as specified and directed. |
| 10 | S&F framed steel work such as grills, gratings, guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework for water tanks and similar works, with ends of bars shouldered and/or riveted or forged into spikes, including cutting, bending, welding, riveting, drilling, assembling, erection and fixing in position, fabricated from steel conforming to Fe-290 Grade E-165, complete all as specified and directed. |
| 11 | Supply of chain link fencing including line wire any mesh and any type (as approved) of standard rails staining bolt etc including provision of binding wire etc complete all as specified and directed. |
| 12 | Fixing only chain link fencing including line wires, and mesh size type of stadrads, rail straining bols etc size of mess 100x100mm 4mm dia wire complete all as specified and direceted. |
| 13 | S&F 11 to 15mm dia of neck mild steel screw bolts (Machine made ) with hexagonal or square heads at one end and screwed at other end or both end, and screwed end to be fitted with washer and one hexagonal or square n.exc 20 cm long etc complete all as specified and directed. |
| 14 | M&L for preparation of new steel surfaces of any description exc. 10cm width or girth ,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 15 | M&L for RCC (Nominal Mix) type B1 1:2:4 (using 20 mm graded crushed stone aggregate) as in foundation including rafts footings Plinth beams & mass concrete etc complete all as specified and directed.Note : Reinforcement shall be measured and paid separately. |
| 16 | M&L for RCC (Nominal Mix) type B1 1:2:4 (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers etc. complete all as specified and directed.Note : Reinforcement shall be measured and paid separately. |
| 17 | Formwork to sides of concrete foundations,footings,bases of columns and soffits of foundation and plinth beam etc complete all as specified and directed. |
| 18 | Formwork to sides of column, post, struts, pillars etc complete all as specified and directed. |
| 19 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of cement primer complete all as specified and directed. |
| 20 | S&F framed work in ornamental and intricate designs such as grills, gratings, gates, guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework for water tanks and similar works, with ends of bars shouldered and/or riveted or forged into spikes, fabricated from steel conforming to Fe-290 Grade E-165, including cutting, bending, welding, riveting, drilling, fastening, erection and fixing in position complete in all respects as specified and directed by the Engineer-in-Charge. |
| 21 | Excavation post holes (or similar holes) each n exc. 0.50 Cum, getting out Hard/ dense soil, Returning, filling in and ramming earth or broken rubble mixed with earth around, in layersn.exc. 25 cm, watering and removing surplus soil to a distance not exc 50m and making good surface complete all as specified and as directed |
| 22 | M&L for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggragated) as in foundation filling and mass concrete, sub base of floor, etc complete all as specified and directed |
| 23 | S&F steel work in tubular trusses, including special shaped washers, cleats, gusset plates, bolts, nuts and all necessary fittings, fabricated from ERW or Induction butt welded steel tubes conforming to IS 1161:1979, Grade St-240, including cutting, bending, welding, drilling, assembling, hoisting, erection and fixing in position complete as specified and directed. |
| 24 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and directed. |
| 25 | Surface excvation in soft and loose soil n. exc. 30 cm deep and averaging 15 cm deep and getting out complete as specified and directed. |
| 26 | M&L for hardcaore of gauge not exceeding 63mm depositeds spread and levelled in layers, not exceeding15 cm thick watered aand rammed to a true surface complete all as specified and as directed. |
| 27 | M&L for rubber moulded coloured glossy finish cement concrete chequered tile of size 25mm thick size exceeding 0.03 sqm but not exceeding 0.16 sqm each, jointed in neat cement slurry and pointed in white or coloured cement and pigment to match the surface of tile over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 28 | Earthwork in excavation in all kind of soil by mechanical means (hydraulic excavator) means over area (n exc 30cm in depth, exe 1.50m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.50m complete all as specified and directed. |
| 29 | Rolling and consolidating formation surface in cutting with 2 to 5 tonne power roller complete all as specified and directed. |
| 30 | M&L for moorum filling in pavings laid in layers 15 cm thick(spread thickness), levelled and blinded with earth and rammed including watering in berms complete all as specified and directed. |
| 31 | M&L for hardcore of guage exceeding 63mm but not exceeding 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed. |
| 32 | M&L for providing and laying at or near ground level factory made kerb stone/Surface drains as in road edgining & surface drain of M-25 grade cement concrete fixed in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 33 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete interlocking paver block of M-35 grade with approved colour (glossy finished), design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of washed fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed by Engr-in-Charge. |
| 34 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete interlocking paver block of M-35 grade with approved colour(glossy), design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of washed fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed by Engr-in Charge. |
| 35 | M&L for preparation of concrete or plastered surfaces of any description over 10cm girth or width, not otherwise described and applying two coats of plastic emulsion paint over a coat of primer complete all as specified and directed. |
| 36 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. |
| 37 | S&F 25 mm thick precast RCC spun pipe, half cut, 200 mm internal diameter, laid and jointed in cement mortar complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |