| 1 | Earth work in excavation of foundation trenches or drains, in amixed soil but excluding laterite or sandstone) including removing, spreading orstacking the spoils within a lead of 75 m. as directed. The item includes necessary timming the sides of trenches, levelling, dressing and ramming tie bottom, bailing out water as required complete.a) Depth of excavation not exceeding to 1500mm |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation. |
| 3 | (B) Filling in foundation or plinth by fine sand in layers not exceeding 150 mm including watering and ramming etc layer by layer complete. |
| 4 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 5 | Ordinary Cement concrete(1:3:6) with 20 mm down graded agregate excluding shuttering In ground floor |
| 6 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. |
| 7 | Reinforcement for reinforced concrete work in all sorts ostructures includingon bars, stirrups, binders etc initial straightening and removal of loose rust (ifnecessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. JSW/JSPL/SHYAM/SRMB/SSL/BMASL |
| 8 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with sgirgohutn required bracing for concrete slabs, beams and columns, lintels including fitting, fixing and striking out after completion of works floor). (f) 25 mm to 30 mm shuttering without staging in foundation Column |
| 9 | (b) Above PL up to roof in gr. Floor |
| 10 | Brick work with 1st class bricks in cement mortar. |
| 11 | 125 mm th brick work with 1st class brick in (1:4) cement morter in ground f |
| 12 | Plaster (to wall,floor,celling etc) with sand and cement morter including rounding off or chamfering corners (i) 10 mm th with (1:4) cement morter. |
| 13 | (ii) 15 mm th with (1:6) cement morter. |
| 14 | Neat cement punning about 1.5mm thick wall dado, window sills, floor, drain etc. |
| 15 | Supplying , fitting & fixing 1st quality ceramic tile ib wall & floo to match with the existing work & 4 nos key stone |
| 16 | Supplying & laying 20 mm designer chequered tiles of any shade and of approved quality as per IS : 1237 :1980 laid in patterns as directed in pavement , footpath including necessary under lay 25 mm thick average cement mortar (1:3) complete in all respect with all labour and materials. |
| 17 | Labour for boring tube well of required dia. by water jet system through any type 5T soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. 50 mm dia. boring.etc. |
| 18 | 100 mm dia. boring.etc. |
| 19 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS :1239 (Part - I). (A) PVC Pipes 32 mm dia. boring.etc. |
| 20 | 50 mm dia. boring.etc |
| 21 | 100 mm dia. boring.etc |
| 22 | supplying PVC strainer oF approved' make with adapte conforming to I.S.12818 Specifications. 50 mm dia. boring.etc. |
| 23 | M.S. structural works with hollow section……………..50mm x 50mm bar(4.98 kg/m) |
| 24 | Supplying PVC water storage tank of approved quality with closed top withlid (Black) Multilayera) 1000 litre capacity |
| 25 | Labour for hoisting plastic water storage tank.Upto 1500 litre capacity. a) Upto 1st story froM G.L. |
| 26 | Labour for punching hole in plastic water storage tank upto 50 mm dia |
| 27 | Supplying, fitting and fixing heavy type bell mouth reducing socket 50 mm X 100 mm |
| 28 | Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. 50mm |
| 29 | Supplying, fitting and fixing G.I. cap at top i)100mm dia |
| 30 | Supplying, fitting and fixing PVC (Chlorinated Polyvinyl Chloride) pipes of approved reducing tee,make conforming to 15-15778: 2007 . with all necessarY accessories, specials viz.fixing socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, etc. complete in all respect including cost of all necessary fittings s. No separate payment materials in any position above ground. (Payment will measurements of total pipe line including all special made for accesories, specials dia (i) 25 mm |
| 31 | (ii) 15 mm |
| 32 | Supplying, fitting and fixing alloy iron withbrass spindlebib cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. 15mm |
| 33 | Diging earth in any soil including mixed soil but excluding moorum laterite sand stone or any other hard stone……. (A) R.C.C. ring well (i) 1.2mtr diameter of digging for 0.90 meter internal dia meter of well ring (a) upto 3.00 m below G.L. |
| 34 | R.C.C. well ring made with cement concrete 1:1.5:3 with stone chips and 0.8% reinforcement ………(a) 65mm thick and 0.9 meter internal dia (0.45x5 nos) |
| 35 | Primimg one coat on timber ,plaster or steel surface |
| 36 | Painting with best quality enamel paint of approved make & brand .. Etc |
| 37 | Solar Module: Supply, Transport, Installation & commissioning of ISI marked Solar Module Multicrystaline/ Monocrystaline/ Monocrystaline PERC/ bifacial cell with min efficiency of 15% & fill factor more than 70% laminated between sheet of Ethylene Vinyl Acetate (EVA) & high transmissivity 3.2/ 4.0 mm tempered glass, framed in anodized aluminium frame. The power output of individual PV modules used in the PV array under STC, should be a minimum 300 watt peak, with adequate provision for measurement tolerances. Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years & 80% at the end of 25 years. Necessary Test Certificates also to be supplied. |
| 38 | Power conditioning unit Supply , transport , insiailaiion and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard , safety standard suitable for 3 Phase A.C. motor, lGBT based high voltage switching invener with MPPT technology, |
| 39 | Cable & Accessories: Supplying, fitting fixing of UV rated Copper Cable laid inside HDPE conduit & other accessories as per followings with necessary connection with the Solar PV module, MPPT etc (i) 4.0mm sq mm single core multi studs - 5m (for 2HP) (II) Lugs, HDPE Pipe, Flexible Pipe , Saddle, Cable tie etc |
| 40 | 2-HP ISI marked -Submersible Pump-motor set for LDTW ISI marked as per lS: 8034 with discharge of 7.i Lps-5.83 Lps at 30 mts.-3S mts. total head with cable(3m), cover plate, Socket, Fianged Nipple, Rubber Insertion, Nuts& bolts and all other accessories including zansportation of Bend, Column Pipes, cable, sluice value, lay flat hose pipe e‹c. |
| 41 | Earthing: Earthing wiih 50 trim dia G I pipe 3.64 mv thick x 3.04 Mts. long and 1 X 4 SWG GI (Hot Dip) wire (4 Mrs. long). 13 mm dia x 80 mm long GJ bolts, double outs, double washers incl. S & F 15 mm dia GI pipe protection ( I Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. be!ow ihe ground level as bclow: By ISI Medium Gl pipe including excavation of soil for installation of Earth Electrode and filling& ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3mm galvanised (Hot Dip) MS flat on wall/door with GI saddles as required and connection to equipments incl drilling holes with bolts nuts washers etc |
| 42 | Iron removal filter 1500LPH size 13'' x 54'' |
| 43 | Add GST @18.0% |
| 44 | Add Labour Cess @1.0% Please Enable Macros to View BoQ information |