| Sl. No. | Item Description |
| 1 | A. SUPPLY SERVICES |
| 2 | SH-I: CONSTRUCTION OF 3-PH, 2X80 MVA, 132/33 KV SUBSTATION AT PATHAR CAMP. |
| 3 | GALVANISED IRON STRUCTURE |
| 4 | Design, fabrication and supplying of hot-dipped GI lattice type tower made with angle iron for 132kV and 33kV gantry towers and switchyard equipments support structures. |
| 5 | Galvanizing Stubs, template Nuts & Bolts, spring washers etc. as reqd. |
| 6 | 132kV SWITCHYARD EQUIPMENTS |
| 7 | 3Ф, 80 MVA, 132/33 KV Transformers as per ISS |
| 8 | EHT transformer oil as per ISI specification amended up to date. |
| 9 | Nitogen Injection Fire Protection System (NIFPS) |
| 10 | Diesel Engine driven Hydrant with water tank, Pump Room, DG driven Pump, O/G & U/G piping, hydrant points for transformer, Control room building , Switcthyard and with complete accesories etc. |
| 11 | Online insulating oil drying system (Catridge type). |
| 12 | 145 kV, 2500 A, 40 kA, SF6, 3- Phase, Circuit Breaker, , with auto-reclosure facility along with support structure. |
| 13 | 145 KV, 200-400-600/1A, 40 kA, 1- phase, 5- Cores current transformer with 120% extended current rating complete in all respects, along with associated accessories and a common MB. (Set of 3 Nos.) |
| 14 | 145 KV, 40 kA, 3- Phase Horizontal Centre Break Isolator with earth switch. |
| 15 | 145 KV, 40 kA, 3- phase Horizontal Centre Break Isolator without earth switch. |
| 16 | 145 KV, 40 kA, 3- phase Horizontal Centre Break Isolator without earth switch.(Tandem) |
| 17 | 120 KV, 1-phase, gapless Surge Arrester, rating (kV rms) - 120, complete in all respects with insulating base and surge monitor |
| 18 | 132 kV, 1-Phase, Capacitive Voltage Transformer with accessories complete in all respect. (Set of 3 Nos.) |
| 19 | 132 KV CONTROL, RELAY AND PROTECTION PANELS WITH SAS COMPATIBILITY |
| 20 | Control & Relay panel for line Bay with primary & backup protective relays, LBB relay and other auxiliary relays as required with SAS and all associated accessories. |
| 21 | Control & Relay panel for Transformer Bay with differential, overfluxing, LBB and backup protective relays and other auxiliary relays as required with SAS and all associated accessories. |
| 22 | Control & Relay panel for bus coupler bay with primary & backup protective relays, LBB relay and other auxiliary relays as required with SAS and all associated accessories. |
| 23 | Digital Protection Couplar (DTPC) |
| 24 | SUBSTATION AUTOMATION SYSTEM (SAS) |
| 25 | Substation Automation System (SAS) conforming to IS-61850, with BCU and other complete associated equipment and accessories. |
| 26 | Remote Terminal Unit & SCADA Gateway with all required ancilliary equipment/materials. |
| 27 | 33 KV EQUIPMENTS |
| 28 | 36 KV, 2500 A, 25 KA,SF6, 3- Phase Circuit Breaker along with support structure |
| 29 | 36 KV, 1000-1600-2000/1A, 25 KA, 1- phase, 3- core current transformer of suitable rated continuous current with 120% extended current rating complete in all respects along with associated and common junction box. |
| 30 | 36 KV, 200-400-600/1A, 25 KA, 1- phase, 3- core current transformer of suitable rated continuous current with 120% extended current rating complete in all respects along with associated and common junction box. |
| 31 | 36 KV, 25 KA, 3-phase, Horizontal Double Break Isolator with one earth switch. |
| 32 | 36 KV, 25 KA, 3-phase, Horizontal Double Break Isolator without earth switch |
| 33 | 36 KV, 1-phase, gap less Surge Arrester complete in all respects with insulating base and surge monitor. |
| 34 | 36 KV, 25 KA, 1 - phase, Potential Transformers |
| 35 | 33 KV CONTROL, RELAY AND PROTECTION PANELS |
| 36 | Control & Relay protection panel for transformer bay for 33 kV system with SAS and all ancillaries. |
| 37 | Relay and protection panel for line bays & Bus Couplar bay for 33 kV system with SA and all ancillaries. |
| 38 | CONTROL & POWER CABLE |
| 39 | Armoured Power Cable (1.1 kV Grade PVC Multi-stranded Aluminium Conductor) |
| 40 | 2 C x 6 Sq. mm |
| 41 | 4 C x 6 Sq. mm |
| 42 | Armoured Control Cable (1.1 KV Grad PVC multi-stranded Copper Conductor) |
| 43 | 2 C x 2.5 Sq. mm |
| 44 | 7 C x 2.5 Sq. mm |
| 45 | 10 C x 2.5 Sq. mm |
| 46 | 12 C x 2.5 Sq. mm |
| 47 | 16 C x 2.5 Sq. mm |
| 48 | 19 C x 2.5 Sq. mm |
| 49 | 33kV XLPE cable |
| 50 | REMOTE ACCESS, DIGITAL TELE-PROTECTION, TELEMETERY & COMMUNICATION SYSTEM |
| 51 | FODP 48F- Indoor type, rack mounted with FCPC coupling and pig tails. |
| 52 | Fiber Optical (ADDSS) Cabling |
| 53 | 24 Fiber ADSS aerial (DWSM) fiber optic cable. |
| 54 | Telecom equipment |
| 55 | SDH Equipment (STM-4 MADM, upto 3 MSP protected directions). |
| 56 | Base equipment (Commn cards, Power Supply cards, Power cabling, other hardware & accessories i/c sub-racks, patch cards, DDF etc. fully equipped. |
| 57 | Optical interface cards / SFP |
| 58 | Optical Line interface Card (to support upto 200 kms). |
| 59 | Tributary Cards |
| 60 | E1 Interface Card (Min. 16 Interface per card). |
| 61 | Ethernet Interface 10/100 Base T with Layer-2 Switching Min. 8 interface per card). |
| 62 | Termination equipment (Drop and insert multiplexer) |
| 63 | Base equipment (Commn cards, power supply cards, power cabling other hardware & accessories i/c sub-racks, patch cards, DDF etc. Fully equipped excluding subscribed line interface cards. |
| 64 | Subscriber Line Interface Cards |
| 65 | 2 Wire (sub / sub) voice channel cards (min.8 channels per card). |
| 66 | 2 Wire (sub / Exch) voice channel cards (min.8 channels per card). |
| 67 | Digital Access Cross Connection Switch (DACS) 16 x 16 ports switching matrix, fully equipment for min 16 E-1 Ports. |
| 68 | Equipment Cabinet |
| 69 | For SDH Equipment (including DDF patching facilities) for Primary Multiplex & other accessories. |
| 70 | For DACS / Mux Equipment. |
| 71 | Craft terminal |
| 72 | Hardware. |
| 73 | Software. |
| 74 | Network manager and element manager system |
| 75 | Hardware. |
| 76 | Software. |
| 77 | Printer (Laser jet). |
| 78 | Main Distribution Frame (200 Pairs). |
| 79 | Synchronization equipment |
| 80 | GPS clock including all hardware & accessories. |
| 81 | 4-points VOIP gateway |
| 82 | Telephone set. |
| 83 | PLCC System complete with all accessories |
| 84 | 132kV, 1250A, 0.5mH, 40kA Line Trap |
| 85 | Coupling Device for PLCC |
| 86 | HF Cable 75 Ohms for PLCC |
| 87 | Carrier Equipment (For Speech+Data & Speech+Protection) |
| 88 | Protection Couplar |
| 89 | EPAX(4/4) with 4 Telephones with cables etc. |
| 90 | Testing & Maintenance Equipment (Print test Kit) for PLCC |
| 91 | DIRECT CURRENT POWER SUPPLY SYSTEM |
| 92 | 200 AH 2V, with required numbers plus 10% spares to add to 110 DC nominal voltage Lead-Acid type battery set having electrolyte level float indicators, terminal, connections, required quantity of electrolyte with connectors & all other accessories, complete as required including float cum boost battery charger with full wave rectification, 50 Hz input voltage for charging 200 AH battery & for making auxiliary DC power required for the sub-station with required cable connectors etc. completed & connection with designed DC back up voltage battery set and AC input supply. |
| 93 | 110 Volt DCDB |
| 94 | 200 AH 2V, with required numbers plus 10% spares to add to 48 Volt DC nominal voltage Lead-Acid type battery set having electrolyte level float indicators, terminal, connections, required quantity of electrolyte with connectors & all other accessories, complete as required including float cum boost battery charger with full wave rectification, 50 Hz input voltage for charging 200 AH battery & for making auxiliary DC power required for the sub-station with required cable connectors etc. completed & connection with designed DC back up voltage battery set and AC input supply. |
| 95 | 48 Volt DCDB |
| 96 | EARTHING SYSTEM |
| 97 | Mat earthing for entire switchyard with 100x10 mm MS Flat iron including 32 mm dia MS Rod. |
| 98 | Copper plate earthing of transformer CBS, Battery charger, etc. including cost of copper plate size 600 x 600 x 6 mm & copper strip of size 25 x 4 mm i/c salt, charcoal etc as required. |
| 99 | Lightning Mast (LM)-40 m or as per suitability complete with foundation bolts/nuts platforms etc. |
| 100 | BUS BAR MATERIALS (HARDWARE KITS) |
| 101 | Bus post insulators & insulator strings, Disc insulators, Hardware, Spacers, Conductor(s), bus bar materials, cable trays, Bay MB, Clamps, connectors including equipment connectors, junction box, Earthwire , Earthing materials, risers, auxiliary earth mat (excluding main earth mat), buried / RCC cable trenches/pipes for equipment & lighting, all accessories etc for the following- |
| 102 | 132kV. |
| 103 | SUB STATION AUXILIARIES |
| 104 | FIRE PROTECTION SYSTEM |
| 105 | 9 litre water type. |
| 106 | 4.5 kg carbon di-oxide type. |
| 107 | 5 kg dry chemical powder type. |
| 108 | Fire detection and Alarm System for C&R panel |
| 109 | AIR CONDITIONING |
| 110 | Split type inverter Air Conditioning Systems. |
| 111 | SWITCH YARD & BUILDING ILLUMINATION (LIGHTING) SYSTEMS |
| 112 | Switchyard lighting with complete cabling. |
| 113 | Street lighting with complete cabling & light posts. |
| 114 | Diesel Generating Set 100 KVA, 415 Volt with control Panel. |
| 115 | STATION TRANSFORMER as per ISS |
| 116 | 3- Ph, 400 KVA, 33/0.433 kV, transformer as per ISS. |
| 117 | 120 sqmm, 3.5 core XLPE cable for Station DT to LT ACDB panel |
| 118 | LT SWITCH GEAR SYSTEMS |
| 119 | 415 Volts main switchboard with panel, Fuse-switch combined unit for LT feeders. |
| 120 | 415 V ACDB |
| 121 | CIVIL WORKS |
| 122 | Civil works associated with equipment foundation |
| 123 | Excavation works |
| 124 | Supply & erection of steel rods of all sizes for RCC works as per design. |
| 125 | Civil works for masonry enclosure for equipment earthing |
| 126 | Cast iron cover of size 650x650 mm along with base for masonry enclosure |
| 127 | POWER TRANSFORMER FIRE PROTECTION CC WALL |
| 128 | Supply & Erection of steel reinforcement of appropriate size. |
| 129 | SUB-STATION LAND DEVELOPMENT |
| 130 | Gravel filling two layer of 100 mm with 10 mm (minimum 100 mm thick) upgraded normal size pebbles and one layer of 100 mm sand filling in switchyard area as per technical specification. |
| 131 | SH-II: CONSTRUCTION OF 132 KV LILO TRANSMISSION LINE ON DOUBLE CIRCUIT TOWERS. |
| 132 | TOWER FOUNDATION WORKS |
| 133 | Concreting |
| 134 | Supply & erection of steel rods of all sizes for RCC works as per design. |
| 135 | SUPPLY OF LINE MATERIALS |
| 136 | Galvanized Iron Structure |
| 137 | Supply of Galvanized Towers, steel members for structure. |
| 138 | Supply of Galvanizing stubs, template Nuts & Bolts of various types of Towers. |
| 139 | Earthing System |
| 140 | Supply of tower Earthing with GI Pipe & strips as per specification. |
| 141 | Supply & Earthing of Tower with counter poise earthing with GI pipes & strips as per specification. |
| 142 | Safety Alert System |
| 143 | Danger Plates of size 250 mm x 200 mm of thickness 3 mm. |
| 144 | Number Plates of size 250 mm x 200 mm of thickness 3 mm. |
| 145 | Phase plates (set of three pieces). |
| 146 | Anti climbing devices with G.I. Thornwire/ Barbed wires. |
| 147 | Conductors as per ISS - Supply |
| 148 | Supply of ACSR Panther (30/7/3.00 sqmm) |
| 149 | Composite polymer insulator(Tension) as per ISS - Supply |
| 150 | 132 kV, 120 KN. |
| 151 | Hardware fittings and accessories (as per ISS) - Supply |
| 152 | Hardware fittings for GI Earthwire 7/3.15 (7/10 SWG) with tension plate. |
| 153 | Single tension 120 kN hardware fittings with all accessories as per ISS for Panther. |
| 154 | Double tension 120 kN hardware fittings with all accessories as per ISS for Panther. |
| 155 | Midspan compression joints for panther. |
| 156 | Repair Sleeve for ACSR Panther conductor. |
| 157 | Vibration Damper for ACSR panther conductor. |
| 158 | PG Clamp for ACSR Panther |
| 159 | OPGW Cable and accessories - Supply |
| 160 | 24 Fiber (DWSM) Optical Fiber Ground Wire (OPGW) |
| 161 | Installation hardware set for 24 fiber OPGW cable i/c all fittings & accessories |
| 162 | Joint box (24 Fiber) for OPGW |
| 163 | SH-III: CONSTRUCTION OF 132 KV LINE BAY AT ROING SUBSTATION |
| 164 | GALVANIZED IRON STRUCTURE |
| 165 | Design, fabrication, supplying and erection of hot-dipped GI lattice type tower made with angle iron for 132kV switchyard equipments support structures. |
| 166 | Supply and erection of Galvanizing Stubs, template Nuts & Bolts, spring washers etc. as reqd. |
| 167 | 132 KV SWITCHYARD EQUIPMENT |
| 168 | 145 kV, 2500 A, 40 kA, SF6, 3- Phase, Circuit Breaker, with auto-reclosure facility along with support structure. |
| 169 | 145 kV, 200-400-600/1A, 1-Phase, 5 Cores, 40kA, Current Transformer with 120% extended current rating, complete in all respects along with associated accessories including terminal clamp for ACSR Panther and a common Junction Box. (Set of 3 Nos.) |
| 170 | 145 kV, 40 kA, 3- phase Horizontal Centre Break Isolator with earth switch with accessories including terminal clamp for ACSR Panther, etc. as required. |
| 171 | 145 kV, 40 kA, 3- phase Horizontal Centre Break Isolator without earth switch with accessories including terminal clamp for ACSR Panther, etc. as required.(Tandem). |
| 172 | 120 KV, 1-Phase, gapless Surge Arrester, complete in all respects with insulating base and surge monitor |
| 173 | 132 kV, 1-Phase, Potential Transformer / Capacitive Voltage Transformer with accessories complete in all respect. (Set of 3) |
| 174 | 132 KV CONTROL AND RELAY PANEL |
| 175 | Control & Relay panel for line bay with primary & backup protective relays, LBB relay and other auxiliary relays as required with SAS and all associated accessories. |
| 176 | CONTROL & POWER CABLE |
| 177 | Armoured Power Cable (1.1 kV Grade PVC Multi-stranded Aluminium Conductor) |
| 178 | 2 C x 6 Sq. mm |
| 179 | 4 C x 6 Sq. mm |
| 180 | Armoured Control Cable (1.1 KV Grad PVC multi-stranded Copper Conductor) |
| 181 | 2 C x 2.5 Sq. mm |
| 182 | 7 C x 2.5 Sq. mm |
| 183 | 10 C x 2.5 Sq. mm |
| 184 | 12 C x 2.5 Sq. mm |
| 185 | 16 C x 2.5 Sq. mm |
| 186 | SUB-STATION AUTOMATION, TELEMETRY AND COMMUNICATION SYSTEM |
| 187 | FODP 48F- Indoor type, rack mounted with FCPC coupling and pig tails. |
| 188 | Fiber Optical (ADDSS) Cabling |
| 189 | 24 Fiber ADSS aerial (DWSM) fiber optic cable. |
| 190 | Remote Terminal Unit & SCADA Gateway with all required ancilliary equipment/materials. |
| 191 | Digital Protection Couplar complete with all accessories. |
| 192 | EARTHING SYSTEM |
| 193 | Mat earthing for entire switchyard with 100x10 mm MS Flat iron including 32 mm dia MS Rod. |
| 194 | Copper plate earthing including cost of copper plate of size 600 x 600 x 6 mm & copper strip of size 25x4 mm i/c Salt, Charcoal etc. as required |
| 195 | 65x8 mm MS Flat for equipment earthing (raisers) |
| 196 | BUS BAR MATERIALS |
| 197 | Supply of ACSR Panther (30/7/3.00 sqmm) |
| 198 | Supply of ACSR Zebra (54/7/3.18 sqmm) |
| 199 | Supply of Disc insulator 120 KN. |
| 200 | Single Tension 120 kN hardware fittings with all accessories as per ISS for Panther. |
| 201 | Double Tension 120 kN hardware fittings with all accessories as per ISS for Zebra. |
| 202 | Suspension type 120 kN hardware fittings with all accessories as per ISS for (Zebra/ Panther). |
| 203 | T-Clamp (Zebra/ Panther) |
| 204 | PG-Clamp (Zebra/ Panther) |
| 205 | 132 kV Post Insulator |
| 206 | CIVIL WORKS |
| 207 | Civil works associated with equipment foundation |
| 208 | Supply & erection of steel rods of all sizes for RCC works as per design. |
| 209 | Civil works for masonry enclosure for equipment earthing |
| 210 | Cast iron cover of size 650x650 mm along with base for masonry enclosure |
| 211 | Cable Trench |
| 212 | Cable Tray (400 mm W x 100 mm H) |
| 213 | GI angle of size 65x65x5 mm for vertical support of cable tray |
| 214 | GI angle of size 50x50x5 mm for horizontal support of cable tray |
| 215 | SUB-STATION LAND DEVELOPMENT |
| 216 | Gravel filling two layer of 100 mm with 10 mm (minimum 100 mm thick) upgraded normal size pebbles and one layer of 100 mm sand filling in switchyard area as per technical specification. |
| 217 | SH-IV: CONSTRUCTION OF 33 KV LINE FROM PATHAR CAMP TO LILO POINT OF ROING-ANINI TRANSMISSION LINE |
| 218 | STEEL TUBULAR POLES as per ISS |
| 219 | 12 Mtr. Long of 410 SP-64 |
| 220 | CONDUCTOR as per ISS |
| 221 | ACSR DOG Conductor(6/7/1.57Smm) |
| 222 | RIVER CROSSING TOWERS |
| 223 | Supply of Galvanized Towers, steel members for structure, including Tower template. |
| 224 | Supply of Galvanizing stubs, template Nuts & Bolts of various types of Towers. |
| 225 | INSULATORS as per ISS |
| 226 | Disc Insulators 90KN |
| 227 | HARDWARE FITTINGS (as per ISS) |
| 228 | 90KN Disk Insulator (33kV tension type hardware fittings) as required. |
| 229 | PIN (Porcelain) |
| 230 | Pin Insulator 33 KV with pin. |
| 231 | CROSS ARMS ( MILD STEEL) |
| 232 | 33 kv, 3 Wire, 3.05 M long cross arm made of channel of size 125 X 50 X 6 mm complete etc. As required. |
| 233 | 33kV 'Y'-Type Cross arm made of angle of size 50X50X6mm in radial structure of 3 arms of 0.9 M long 120 deg apart complete etc. as reuired. |
| 234 | GI STAY SET |
| 235 | Galvanized stay set complete with galvanised MS anchor plate of size 300X300X5mm, anchor rod of length 1800mm & dia 18mm along with stay wire, thimble, bow, guy strain insulator, nut & bolts etc. As required ( of all sizes). |
| 236 | CROSS BRACING (MILD STEEL) |
| 237 | Angle bracing set 3.6m long of sizes 65X65X6mm complete with accessories nut/bolts etc. As required. |
| 238 | SAFETY ALERT SYSTEM |
| 239 | Manufacturing, fabricating and supply of danger plate made of mild steel sheet of atleast 1.6mm thick and vitreous enameled white, with letyters, figures and the conventional skull and cross-bones in signal red colour on the front side for- |
| 240 | Danger Plate of size 250mm X 200 mm of thickness 3 mm. |
| 241 | Anti-Climbing devices with GI thornwire/Barbed wires. |
| 242 | GUARD BRACKET (MILD STEEL) |
| 243 | 33kV 3.5 M long Guard Bracket made of channel of size 100X50X6mm complete etc. As required. |
| 244 | Supply & Stringing of 8 SWG G.I Earth wire. |
| 245 | EARTHING SYSTEM |
| 246 | Earthing with 40 mm dia GI pipe 4.5 Mtr. Long with GI wire for pole earthing including salt charcoal etc. As required. |
| 247 | SH-V: MANDATORY SPARES FOR SUBSTATION AND TRANSMISSION LINE |
| 248 | 132 KV EQUIPMENT |
| 249 | 145 KV, 1250 A, 31.5 KA, SF6, 3- phase Circuit Breaker. |
| 250 | 145 KV, 600 A, 31.5 KA, 1- Phase, 3- core current transformer with 120% extended current rating complete in all respects along with associated accessories and a common MB. (Set of 3 Nos.) |
| 251 | 145 KV, 1250 A, 31.5 KA, 3- phase Horizontal Centre Break Isolator with earth switch. |
| 252 | 145 KV, 1250 A, 31.5 KA, 3- phase Horizontal Centre Break Isolator without earth switch. |
| 253 | 120 KV, 1-phase, gapless Surge Arrester complete in all respects with insulating base and surge monitor |
| 254 | 132kV 1-Φ Capacitive Voltage Transformer (CVT) with accessories (Set of 3 Nos.) |
| 255 | Oil Storage Tank (15kL) |
| 256 | 33 KV EQUIPMENT |
| 257 | 36 KV, 1250 A, 25 KA,VCB, 3- Phase Circuit Breaker along with support structure |
| 258 | 36 KV, 1250 A, 25 KA, 1- phase, 3- core current transformer of suitable rated continuous current with 120% extended current rating complete in all respects along with associated and common junction box. |
| 259 | 36 KV, 630A, 25 KA, 3-phase, Horizontal Double Break Isolator with one earth switch. |
| 260 | 36 KV, 630A, 25 KA, 3-phase, Horizontal Double Break Isolator without earth switch |
| 261 | 30 KV, 1-phase, gap less Surge Arrester complete in all respects with insulating base and surge monitor. |
| 262 | 36 KV, 25 KA, 1 - phase, Potential Transformers |
| 263 | Control and Power cables |
| 264 | Armoured Control Cable (1.1KV grade PVC multi-stranded Copper Conductor) |
| 265 | 4C X 2.5Sq.mm |
| 266 | 7C X 2.5Sq.mm |
| 267 | Armoured Power Cable (1.2kV Grade PVC Multi-stranded Aluminium Conductor) |
| 268 | 4C X 6 Sq.mm |
| 269 | 132 kV Transmission line |
| 270 | Supply of ACSR Panther(30/73.00 Sq.mm) |
| 271 | 132kV 120 KN Composite Polymer Insulator(Tension) as per ISS |
| 272 | Midspan compression joints for panther. |
| 273 | Repair Sleeve for ACSR Panther conductor. |
| 274 | PG Clamp for ACSR Panther |
| 275 | B. ERECTION SERVICES |
| 276 | SH-I: CONSTRUCTION OF 3-PH, 2X80 MVA, 132/33 KV SUBSTATION AT PATHAR CAMP. |
| 277 | SURVEY & INVESTIGATION |
| 278 | Soil Investigation |
| 279 | All kinds of soil except the following classifications. |
| 280 | Fissured rock with mixed soil. |
| 281 | Hard soil with fissured rock. |
| 282 | GALVANISED IRON STRUCTURE |
| 283 | Design, fabrication and supplying of hot-dipped GI lattice type tower made with angle iron for 132kV and 33kV gantry towers and switchyard equipments support structures. |
| 284 | Galvanizing Stubs, template Nuts & Bolts, spring washers etc. as reqd. |
| 285 | 132kV SWITCHYARD EQUIPMENTS |
| 286 | 3Ф, 80 MVA, 132/33 KV Transformers as per ISS |
| 287 | Nitogen Injection Fire Protection System (NIFPS) |
| 288 | Diesel Engine driven Hydrant with water tank, Pump Room, DG driven Pump, O/G & U/G piping, hydrant points for transformer, Control room building , Switcthyard and with complete accesories etc. |
| 289 | Online insulating oil drying system (Catridge type). |
| 290 | 145 kV, 2500 A, 40 kA, SF6, 3- Phase, Circuit Breaker, , with auto-reclosure facility along with support structure. |
| 291 | 145 KV, 200-400-600/1A, 40 kA, 1- phase, 5- Cores current transformer with 120% extended current rating complete in all respects, along with associated accessories and a common MB. (Set of 3 Nos.) |
| 292 | 145 KV, 40 kA, 3- Phase Horizontal Centre Break Isolator with earth switch. |
| 293 | 145 KV, 40 kA, 3- phase Horizontal Centre Break Isolator without earth switch. |
| 294 | 145 KV, 40 kA, 3- phase Horizontal Centre Break Isolator without earth switch.(Tandem) |
| 295 | 120 KV, 1-phase, gapless Surge Arrester, rating (kV rms) - 120, complete in all respects with insulating base and surge monitor |
| 296 | 132 kV, 1-Phase, Capacitive Voltage Transformer with accessories complete in all respect. (Set of 3 Nos.) |
| 297 | 132 KV CONTROL, RELAY AND PROTECTION PANELS WITH SAS COMPATIBILITY |
| 298 | Control & Relay panel for line Bay with primary & backup protective relays, LBB relay and other auxiliary relays as required with SAS and all associated accessories. |
| 299 | Control & Relay panel for Transformer Bay with differential, overfluxing, LBB and backup protective relays and other auxiliary relays as required with SAS and all associated accessories. |
| 300 | Control & Relay panel for bus coupler bay with primary & backup protective relays, LBB relay and other auxiliary relays as required with SAS and all associated accessories. |
| 301 | Digital Protection Couplar (DTPC) |
| 302 | SUBSTATION AUTOMATION SYSTEM (SAS) |
| 303 | Substation Automation System (SAS) conforming to IS-61850, with BCU and other complete associated equipment and accessories. |
| 304 | Remote Terminal Unit & SCADA Gateway with all required ancilliary equipment/materials. |
| 305 | 33 KV EQUIPMENTS |
| 306 | 36 KV, 2500 A, 25 KA,SF6, 3- Phase Circuit Breaker along with support structure |
| 307 | 36 KV, 1000-1600-2000/1A, 25 KA, 1- phase, 3- core current transformer of suitable rated continuous current with 120% extended current rating complete in all respects along with associated and common junction box. |
| 308 | 36 KV, 200-400-600/1A, 25 KA, 1- phase, 3- core current transformer of suitable rated continuous current with 120% extended current rating complete in all respects along with associated and common junction box. |
| 309 | 36 KV, 25 KA, 3-phase, Horizontal Double Break Isolator with one earth switch. |
| 310 | 36 KV, 25 KA, 3-phase, Horizontal Double Break Isolator without earth switch |
| 311 | 36 KV, 1-phase, gap less Surge Arrester complete in all respects with insulating base and surge monitor. |
| 312 | 36 KV, 25 KA, 1 - phase, Potential Transformers |
| 313 | 33 KV CONTROL, RELAY AND PROTECTION PANELS |
| 314 | Control & Relay protection panel for transformer bay for 33 kV system with SAS and all ancillaries. |
| 315 | Relay and protection panel for line bays & Bus Couplar bay for 33 kV system with SA and all ancillaries. |
| 316 | CONTROL & POWER CABLE |
| 317 | Armoured Power Cable (1.1 kV Grade PVC Multi-stranded Aluminium Conductor) |
| 318 | 2 C x 6 Sq. mm |
| 319 | 4 C x 6 Sq. mm |
| 320 | Armoured Control Cable (1.1 KV Grad PVC multi-stranded Copper Conductor) |
| 321 | 2 C x 2.5 Sq. mm |
| 322 | 7 C x 2.5 Sq. mm |
| 323 | 10 C x 2.5 Sq. mm |
| 324 | 12 C x 2.5 Sq. mm |
| 325 | 16 C x 2.5 Sq. mm |
| 326 | 19 C x 2.5 Sq. mm |
| 327 | 33kV XLPE cable |
| 328 | REMOTE ACCESS, DIGITAL TELE-PROTECTION, TELEMETERY & COMMUNICATION SYSTEM |
| 329 | Integration of Hardware systems with last mile connections with Optical Power Ground Wire and Optical Fiber Cables in each Sub Station. |
| 330 | Telecom equipment |
| 331 | Installation of various Telecom Equipments, Software and Integrating all the Systems, Testing, Commissioning and Operationalising them in each Sub Station. |
| 332 | Tributary Cards |
| 333 | E1 Interface Card (Min. 16 Interface per card). |
| 334 | Ethernet Interface 10/100 Base T with Layer-2 Switching Min. 8 interface per card). |
| 335 | Termination equipment (Drop and insert multiplexer) |
| 336 | Base equipment (Commn cards, power supply cards, power cabling other hardware & accessories i/c sub-racks, patch cards, DDF etc. Fully equipped excluding subscribed line interface cards. |
| 337 | Subscriber Line Interface Cards |
| 338 | 2 Wire (sub / sub) voice channel cards (min.8 channels per card). |
| 339 | 2 Wire (sub / Exch) voice channel cards (min.8 channels per card). |
| 340 | Digital Access Cross Connection Switch (DACS) 16 x 16 ports switching matrix, fully equipment for min 16 E-1 Ports. |
| 341 | Equipment Cabinet |
| 342 | For SDH Equipment (including DDF patching facilities) for Primary Multiplex & other accessories. |
| 343 | For DACS / Mux Equipment. |
| 344 | Craft terminal |
| 345 | Hardware. |
| 346 | Software. |
| 347 | Network manager and element manager system |
| 348 | Hardware. |
| 349 | Software. |
| 350 | Printer (Laser jet). |
| 351 | Main Distribution Frame (200 Pairs). |
| 352 | Synchronization equipment |
| 353 | GPS clock including all hardware & accessories. |
| 354 | 4-points VOIP gateway |
| 355 | Telephone set. |
| 356 | PLCC System complete with all accessories |
| 357 | 132kV, 1250A, 0.5mH, 40kA Line Trap |
| 358 | Coupling Device for PLCC |
| 359 | HF Cable 75 Ohms for PLCC |
| 360 | Carrier Equipment (For Speech+Data & Speech+Protection) |
| 361 | Protection Couplar |
| 362 | EPAX(4/4) with 4 Telephones with cables etc. |
| 363 | Testing & Maintenance Equipment (Print test Kit) for PLCC |
| 364 | DIRECT CURRENT POWER SUPPLY SYSTEM |
| 365 | 200 AH 2V, with required numbers plus 10% spares to add to 110 DC nominal voltage Lead-Acid type battery set having electrolyte level float indicators, terminal, connections, required quantity of electrolyte with connectors & all other accessories, complete as required including float cum boost battery charger with full wave rectification, 50 Hz input voltage for charging 200 AH battery & for making auxiliary DC power required for the sub-station with required cable connectors etc. completed & connection with designed DC back up voltage battery set and AC input supply. |
| 366 | 110 Volt DCDB |
| 367 | 200 AH 2V, with required numbers plus 10% spares to add to 48 Volt DC nominal voltage Lead-Acid type battery set having electrolyte level float indicators, terminal, connections, required quantity of electrolyte with connectors & all other accessories, complete as required including float cum boost battery charger with full wave rectification, 50 Hz input voltage for charging 200 AH battery & for making auxiliary DC power required for the sub-station with required cable connectors etc. completed & connection with designed DC back up voltage battery set and AC input supply. |
| 368 | 48 Volt DCDB |
| 369 | EARTHING SYSTEM |
| 370 | Mat earthing for entire switchyard with 100x10 mm MS Flat iron including 32 mm dia MS Rod. |
| 371 | Copper plate earthing of transformer CBS, Battery charger, etc. including cost of copper plate size 600 x 600 x 6 mm & copper strip of size 25 x 4 mm i/c salt, charcoal etc as required. |
| 372 | Lightning Mast (LM)-40 m or as per suitability complete with foundation bolts/nuts platforms etc. |
| 373 | BUS BAR MATERIALS (HARDWARE KITS) |
| 374 | Bus post insulators & insulator strings, Disc insulators, Hardware, Spacers, Conductor(s), bus bar materials, cable trays, Bay MB, Clamps, connectors including equipment connectors, junction box, Earthwire , Earthing materials, risers, auxiliary earth mat (excluding main earth mat), buried / RCC cable trenches/pipes for equipment & lighting, all accessories etc for the following- |
| 375 | 132kV. |
| 376 | SUB STATION AUXILIARIES |
| 377 | FIRE PROTECTION SYSTEM |
| 378 | 9 litre water type. |
| 379 | 4.5 kg carbon di-oxide type. |
| 380 | 5 kg dry chemical powder type. |
| 381 | Fire detection and Alarm System for C&R panel |
| 382 | AIR CONDITIONING |
| 383 | Split type inverter Air Conditioning Systems. |
| 384 | SWITCH YARD & BUILDING ILLUMINATION (LIGHTING) SYSTEMS |
| 385 | Switchyard lighting with complete cabling. |
| 386 | Street lighting with complete cabling & light posts. |
| 387 | Diesel Generating Set 100 KVA, 415 Volt with control Panel. |
| 388 | STATION TRANSFORMER |
| 389 | 3- Ph, 400 KVA, 33/0.433 kV, transformer. |
| 390 | 120 sqmm, 3.5 core XLPE cable for Station DT to LT ACDB panel |
| 391 | LT SWITCH GEAR SYSTEMS |
| 392 | 415 Volts main switchboard with panel, Fuse-switch combined unit for LT feeders. |
| 393 | 415 V ACDB |
| 394 | CIVIL WORKS |
| 395 | Civil works associated with equipment foundation |
| 396 | Excavation works |
| 397 | All kind of soil except the following classification. |
| 398 | Fissured Rock with mixed soil. |
| 399 | Hard soil with fissured rock. |
| 400 | Design & Concreting of equipment footing work on 100% full rate (i.e. Supply & erection of RCC works with cement & concrete) excluding cost of reinforcement steel. |
| 401 | Normal mix Ratio1:2:4 for M15 compressive strength. |
| 402 | Plain Cement Concrete (PCC) work at base of equipment footings on 100 % full rate at nominal ratio of 1:3:6 or minimum M10 Compressive strength. |
| 403 | Supply & erection of steel rods of all sizes for RCC works as per design. |
| 404 | Brick Work with best available local bricks in foundation and plinth in cement mortar 1:4 (1 Cement: 4 Sand) |
| 405 | Civil works for masonry enclosure for equipment earthing |
| 406 | Half Brick masonry with best available local brick in cement mortar 1:4 (1 Cement: 4 Coarse Sand) in foundation and plinth. |
| 407 | 12 mm Cement Plaster 1:3 (1 Cement: 3 Fine Sand) |
| 408 | Cast iron cover of size 650x650 mm along with base for masonry enclosure |
| 409 | CABLE TRENCHES |
| 410 | Cable trenches with 1:2:4 PCC work including supply and fabrication of 4 mm steel cover as per design of following sections:- |
| 411 | Section 75cm x 75cm x 10cm (depth x width x thickness) |
| 412 | Section 75cm x 100cm x 10cm. |
| 413 | Section 100cm x 150cm x 10cm. |
| 414 | OTHER ALLIED CIVIL WORKS |
| 415 | Design, Engineering and construction of approach road and footpath on 100% full rate i/c T&P, Labour, cement, reinforcement steel, bricks, stone, sand, single earth bitumen and form work, excavation compaction etc. all complete as per approved design and drawing or as may be required. |
| 416 | Roads 3.75 m wide (including all crossings) Black topped with broken as aggregate with Hot or Cold bitumen (8cm thick) over RBM base of 10 Cm. |
| 417 | 1:2:4 ratio M 15 compression strength PCC path in switch yard (Thickness of cement concrete 8 cm and of RBM base 10 cm). |
| 418 | 1:3:6 M 10 compression strength Water Drainage as per design in PCC works. |
| 419 | Security wall around the sub station (Brick wall with M15 RCC pillar) on 100% full rate base. |
| 420 | POWER TRANSFORMER FIRE PROTECTION CC WALL |
| 421 | Design and concreting of CC wall of 1:2:4 (M15) compression strength. |
| 422 | Supply & Erection of steel reinforcement of appropriate size. |
| 423 | Main Gate complete with all necessary fittings |
| 424 | SUB-STATION LAND DEVELOPMENT |
| 425 | Sub-station area land development. |
| 426 | Gravel filling two layer of 100 mm with 10 mm (minimum 100 mm thick) upgraded normal size pebbles and one layer of 100 mm sand filling in switchyard area as per technical specification. |
| 427 | BUILDING WORKS |
| 428 | CONTROL ROOM |
| 429 | Design, Engineering and construction of RCC structured, Control Room with glass panels on aluminium frames i/c glazing, false ceiling, tiled floors Electrification ( Conceal Conduit), Water supply, Air Conditioning, Battery Room, Office Room, One bed room with toilet and kitchen fully fitted and furnished with fitting furniture, complete as per approved drawing for the estimate area of 150 to 300 sqm. or as per approved design and plinth area for direct use (Details as per TS) on 100% full rate basis. |
| 430 | RCC structure, DG set room with brick wall & rolling shutters annexed to the control room with cable connections to the systems (Approx.-20 sqm.) on 100% full rate basis. |
| 431 | Security Room complete with electrical fittings |
| 432 | HILL ROAD TRANSPORTATION & HEAD LOADING |
| 433 | Transportation from Designated Bare store (DBS) at Assam-Arunachal boarders to the last road head. (350 MT x 90 km) |
| 434 | SH-II: CONSTRUCTION OF 132 KV LILO TRANSMISSION LINE ON DOUBLE CIRCUIT TOWERS. |
| 435 | SURVEY |
| 436 | Detailed survey including route alignment profiling, tower spotting & final check survey. |
| 437 | Check survey. |
| 438 | SOIL INVESTIGATION |
| 439 | All kinds of soil except the following classifications |
| 440 | Fissured rock with mixed soil |
| 441 | Hard soil with Fissured Rock. |
| 442 | Hard Rock. |
| 443 | Boring up to a depth of 40 mtr below ground level in soil, gravel boulder deposit including core drilling, conducting SPT, collection of disturbed and undisturbed sample and conducting Laboratory test. |
| 444 | TOWER FOUNDATION WORKS |
| 445 | Benching & Excavation works |
| 446 | All kind of soil except the following classification. |
| 447 | Fissured Rock with mixed soil. |
| 448 | Hard soil with Fissured Rock. |
| 449 | Hard Rock. |
| 450 | Concreting |
| 451 | Design & Concreting of Tower footing work on 100% full rate (i.e. Supply & erection of RCC works with cement & concrete) excluding cost of reinforcement steel. |
| 452 | Normal mix Ratio1:2:4 for M15 compressive strength. |
| 453 | Plain Cement Concrete (PCC) work at base of Tower footings on 100 % full rate at nominal ratio of 1:3:6 or minimum M10 Compressive strength. |
| 454 | Supply & erection of steel rods of all sizes for RCC works as per design. |
| 455 | Pavement (Protection of Tower) |
| 456 | Random rubble stone masonry i/c excavation (with 1:4:8 mixture). |
| 457 | Stone bound in galvanized wire netting i/c excavation. |
| 458 | Back filling and leveling of volumes enclosed in revetment. |
| 459 | Concrete for top seal cover of pavement mix ratio:1:2:4 (M15) |
| 460 | PILE FOUNDATION |
| 461 | Boring, providing and installation of bored cast-in-situ RCC vertical piles of specified diameter and of any length below the pile cap with M25 grade of cement concrete, excluding the cost of reinforcement steel but including the cost of boring with temporary guide casing, bentonite solution and the length of pile to be embedded in the pile cap (length of pile for payment shall be measured from bottom of pile cap), all necessary labour, materials, plants, tools & tackles etc. complete, as necessary for proper execution of the job (boring weathered rock, shell, fissured rock and soft rock excluded). |
| 462 | 1000 mm diameter RCC vertical bored pile up to 42 mtr. from bottom of pile cap. |
| 463 | Extra over item 1.1. for boring including socketing, anchoring (if required) with required size, nos. & depth of reinforcement in weathered rock, shell, fissured rock, soft rock and hard rock up to a maximum depth of 5.00 mtr. |
| 464 | Excavation (other than boring) for all depths & sizes, in all types of soils including disposal of excavated materials for all lifts & leads, decent etc. as directed by Engineer-in-Charge, together with all labour, tools & tackles, sheeting, sheet piling, dewatering etc. complete as required for proper execution of the job. |
| 465 | Back filling with available excavated earth for all leads and lifts in sides of foundations and other underground facilities in horizontal layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering etc. |
| 466 | Form work for placing plain or reinforced cement concrete of any type including blockout and section at any elevation shoring, shuttering, strutting, propping, scaffolding, tieing, nailing, including all labour, materials, equipments, wastes for form, caulking, dismantling & removal of forms etc. complete. |
| 467 | Supply & placement of steel reinforcement of specified grade for RCC work in pile, pile cap, pedestal/chimney tie beam (if required) including straightening, cutting, bending, binding etc. all complete. |
| 468 | Providing & laying in position M25 grade concrete of specified 28 days strength for pile caps, pedestal/chimney and tie beam (if required), excluding reinforcement steel and form work but including cement, all necessary tools & tackles, labours, materials, equipments for handling, transportation, batching, mixing, placing, vibrating, dewatering etc. all complete (excluding cost of concrete piles which is included in item No. 2.1). |
| 469 | Providing & laying plain cement concrete 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) including cement, all necessary tools & tackles, labour, materials, equipments for handling, transportation, mixing, placing, vibrating, dewatering etc. all complete. |
| 470 | Conducting Standard Penetration Test (SPT) at various elevations in pile bore holes in all kind of soils including all labour, materials, tools & tackles, equipments etc. required for successful completion of the job. |
| 471 | Supply & providing MS liner of 6 mm thick in piles up to specified depth (maximum) from bottom of the pile cap, limited to the approved drawing, including supply, straightening, bending, welding, all supports, labours, tools & tackles, plants & equipments, with primer & painting etc. (complete) as required for successful completion of the job. |
| 472 | Conducting integrity test on pile using electronic control unit, hand held hammer, accelerometer, computer with required software to assess as-installed pile characteristics including mobilization of necessary manpower, equipments, materials etc. required for successful completion of the job. |
| 473 | ERECTION OF LINE MATERIALS |
| 474 | Galvanized Iron Structure |
| 475 | Erection of various types of towers and its body leg extension set (complete) i/c tuck and nuts, step bolts, hangers, D-shackles etc and i/c tuck welding and supply & application of enamel and Zinc rich paint. |
| 476 | Safety Alert System |
| 477 | Danger Plates of size 250 mm x 200 mm of thickness 3 mm. |
| 478 | Number Plates of size 250 mm x 200 mm of thickness 3 mm. |
| 479 | Phase plates (set of three pieces). |
| 480 | Anti climbing devices with G.I. Thornwire/ Barbed wires. |
| 481 | Stringing of line and accessories |
| 482 | Stringing of single circuit transmission line, (three ACSR Panther Conductor) installation of insulator strings (complete fitting) with arcing horns and necessary hardware fitting, (i/c fixing of accessories for power and OPGW Conductors). |
| 483 | JUNGLE CLEARANCE |
| 484 | Cutting of trees, including cutting of trunks, branches and removal of stems, branches from the cutting area, stacking of serviceable materials at specified place not exceeding a distance of 1000 m from the cutting area along the ROW corridor of transmission lines, sub stations and other power stations. |
| 485 | Girth above 300 mm to 600 mm. |
| 486 | Girth above 600 mm to 1000 mm. |
| 487 | Girth above 1000 mm. |
| 488 | HILL ROAD TRANSPORTATION & HEAD LOADING |
| 489 | Transportation from Designated Bare store (DBS) at Assam-Arunachal boarders to the last road head. (150 MT x 70 km) |
| 490 | Transportation of Materials by head loading from road head to the site of work. Beyond a lead of 100 meters from road to the head load end point payable extra for head load. (150 MT x 200 Mtr) |
| 491 | SH-III: CONSTRUCTION OF 132 KV LINE BAY AT ROING SUBSTATION |
| 492 | SURVEY & INVESTIGATION |
| 493 | Soil Investigation |
| 494 | All kinds of soil except the following classifications. |
| 495 | Fissured rock with mixed soil. |
| 496 | Hard soil with fissured rock. |
| 497 | GALVANIZED IRON STRUCTURE |
| 498 | Design, fabrication, supplying and erection of hot-dipped GI lattice type tower made with angle iron for 132kV switchyard equipments support structures. |
| 499 | Supply and erection of Galvanizing Stubs, template Nuts & Bolts, spring washers etc. as reqd. |
| 500 | 132 KV SWITCHYARD EQUIPMENT |
| 501 | 145 kV, 2500 A, 40 kA, SF6, 3- Phase, Circuit Breaker, with auto-reclosure facility along with support structure. |
| 502 | 145 kV, 200-400-600/1A, 1-Phase, 5 Cores, 40kA, Current Transformer with 120% extended current rating, complete in all respects along with associated accessories including terminal clamp for ACSR Panther and a common Junction Box. (Set of 3 Nos.) |
| 503 | 145 kV, 40 kA, 3- phase Horizontal Centre Break Isolator with earth switch with accessories including terminal clamp for ACSR Panther, etc. as required. |
| 504 | 145 kV, 40 kA, 3- phase Horizontal Centre Break Isolator without earth switch with accessories including terminal clamp for ACSR Panther, etc. as required.(Tandem). |
| 505 | 120 KV, 1-Phase, gapless Surge Arrester, complete in all respects with insulating base and surge monitor |
| 506 | 132 kV, 1-Phase, Potential Transformer / Capacitive Voltage Transformer with accessories complete in all respect. (Set of 3) |
| 507 | 132 KV CONTROL AND RELAY PANEL |
| 508 | Control & Relay panel for line bay with primary & backup protective relays, LBB relay and other auxiliary relays as required with SAS and all associated accessories. |
| 509 | CONTROL & POWER CABLE |
| 510 | Armoured Power Cable (1.1 kV Grade PVC Multi-stranded Aluminium Conductor) |
| 511 | 2 C x 6 Sq. mm |
| 512 | 4 C x 6 Sq. mm |
| 513 | Armoured Control Cable (1.1 KV Grad PVC multi-stranded Copper Conductor) |
| 514 | 2 C x 2.5 Sq. mm |
| 515 | 7 C x 2.5 Sq. mm |
| 516 | 10 C x 2.5 Sq. mm |
| 517 | 12 C x 2.5 Sq. mm |
| 518 | 16 C x 2.5 Sq. mm |
| 519 | SUB-STATION AUTOMATION, TELEMETRY AND COMMUNICATION SYSTEM |
| 520 | Integration of Hardware systems with last mile connections with OPGW and Optical Fiber Cables (Integration with existing SAS, SCADA Gateway, BCU, RTU, DTPC, SDH, FODP/OFC and associated communication systems, including configuration, database modification, signal mapping, testing, commissioning and end-to-end telemetry verification) |
| 521 | Remote Terminal Unit & SCADA Gateway with all required ancilliary equipment/materials. |
| 522 | Digital Protection Couplar complete with all accessories. |
| 523 | EARTHING SYSTEM |
| 524 | Mat earthing for entire switchyard with 100x10 mm MS Flat iron including 32 mm dia MS Rod. |
| 525 | Copper plate earthing including cost of copper plate of size 600 x 600 x 6 mm & copper strip of size 25x4 mm i/c Salt, Charcoal etc. as required |
| 526 | 65x8 mm MS Flat for equipment earthing (raisers) |
| 527 | BUS BAR MATERIALS |
| 528 | PG-Clamp (Zebra/ Panther) |
| 529 | 132 kV Post Insulator |
| 530 | Fitting of bus bar conductor with insulator strings, hardware fittings, etc. as required. |
| 531 | CIVIL WORKS |
| 532 | Civil works associated with equipment foundation |
| 533 | Excavation works |
| 534 | All kind of soil except the following classification. |
| 535 | Fissured Rock with mixed soil. |
| 536 | Hard soil with fissured rock. |
| 537 | Design & Concreting of equipment footing work on 100% full rate (i.e. Supply & erection of RCC works with cement & concrete) excluding cost of reinforcement steel. |
| 538 | Normal mix Ratio1:2:4 for M15 compressive strength. |
| 539 | Plain Cement Concrete (PCC) work at base of equipment footings on 100 % full rate at nominal ratio of 1:3:6 or minimum M10 Compressive strength. |
| 540 | Supply & erection of steel rods of all sizes for RCC works as per design. |
| 541 | Civil works for masonry enclosure for equipment earthing |
| 542 | Half Brick masonry with best available local brick in cement mortar 1:4 (1 Cement: 4 Coarse Sand) in foundation and plinth. |
| 543 | 12 mm Cement Plaster 1:3 (1 Cement: 3 Fine Sand) |
| 544 | Cast iron cover of size 650x650 mm along with base for masonry enclosure |
| 545 | Cable Trench |
| 546 | Cable trenches with 1:2:4 PCC work including supply and fabrication of 4 mm steel cover as per design of following sections:- |
| 547 | Section 75cm x 75cm x 10cm (depth x width x thickness) |
| 548 | Section 75cm x 100cm x 10cm. |
| 549 | Section 100cm x 150cm x 10cm. |
| 550 | Cable Tray (400 mm W x 100 mm H) |
| 551 | GI angle of size 65x65x5 mm for vertical support of cable tray |
| 552 | GI angle of size 50x50x5 mm for horizontal support of cable tray |
| 553 | SUB-STATION LAND DEVELOPMENT |
| 554 | Jungle clearance, earth cutting/ benching, leveling and removal of debris. |
| 555 | Gravel filling two layer of 100 mm with 10 mm (minimum 100 mm thick) upgraded normal size pebbles and one layer of 100 mm sand filling in switchyard area as per technical specification. |
| 556 | HILL ROAD TRANSFORTATION |
| 557 | Transportation from Designated Bare Store (DBS) at Assam-Arunachal borders to the last Road head. (Weight & distance to be estimated). (80 MT x 46 km) |
| 558 | SH-IV: CONSTRUCTION OF 33 KV LINE FROM PATHAR CAMP TO LILO POINT OF ROING-ANINI TRANSMISSION LINE |
| 559 | STEEL TUBULAR POLES |
| 560 | 12 Mtr. Long of 410 SP-64 |
| 561 | RIVER CROSSING TOWERS |
| 562 | Erection of various types of towers and its body leg extension set (complete) i/c tuck and nuts, step bolts, hangers, D-shackles etc and i/c tuck welding and supply & application of enamel and Zinc rich paint. |
| 563 | PILE FOUNDATION FOR RIVER CROSSING TOWERS |
| 564 | Boring, providing and installation of bored cast-in-situ RCC vertical piles of specified diameter and of any length below the pile cap with M25 grade of cement concrete, excluding the cost of reinforcement steel but including the cost of boring with temporary guide casing, bentonite solution and the length of pile to be embedded in the pile cap (length of pile for payment shall be measured from bottom of pile cap), all necessary labour, materials, plants, tools & tackles etc. complete, as necessary for proper execution of the job (boring weathered rock, shell, fissured rock and soft rock excluded). |
| 565 | 1000 mm diameter RCC vertical bored pile up to 42 mtr. from bottom of pile cap. |
| 566 | Extra over item 1.1. for boring including socketing, anchoring (if required) with required size, nos. & depth of reinforcement in weathered rock, shell, fissured rock, soft rock and hard rock up to a maximum depth of 5.00 mtr. |
| 567 | Excavation (other than boring) for all depths & sizes, in all types of soils including disposal of excavated materials for all lifts & leads, decent etc. as directed by Engineer-in-Charge, together with all labour, tools & tackles, sheeting, sheet piling, dewatering etc. complete as required for proper execution of the job. |
| 568 | Back filling with available excavated earth for all leads and lifts in sides of foundations and other underground facilities in horizontal layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering etc. |
| 569 | Form work for placing plain or reinforced cement concrete of any type including blockout and section at any elevation shoring, shuttering, strutting, propping, scaffolding, tieing, nailing, including all labour, materials, equipments, wastes for form, caulking, dismantling & removal of forms etc. complete. |
| 570 | Supply & placement of steel reinforcement of specified grade for RCC work in pile, pile cap, pedestal/chimney tie beam (if required) including straightening, cutting, bending, binding etc. all complete. |
| 571 | Providing & laying in position M25 grade concrete of specified 28 days strength for pile caps, pedestal/chimney and tie beam (if required), excluding reinforcement steel and form work but including cement, all necessary tools & tackles, labours, materials, equipments for handling, transportation, batching, mixing, placing, vibrating, dewatering etc. all complete (excluding cost of concrete piles). |
| 572 | Providing & laying plain cement concrete 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) including cement, all necessary tools & tackles, labour, materials, equipments for handling, transportation, mixing, placing, vibrating, dewatering etc. all complete. |
| 573 | Conducting Standard Penetration Test (SPT) at various elevations in pile bore holes in all kind of soils including all labour, materials, tools & tackles, equipments etc. required for successful completion of the job. |
| 574 | Supply & providing MS liner of 6 mm thick in piles up to specified depth (maximum) from bottom of the pile cap, limited to the approved drawing, including supply, straightening, bending, welding, all supports, labours, tools & tackles, plants & equipments, with primer & painting etc. (complete) as required for successful completion of the job. |
| 575 | Conducting integrity test on pile using electronic control unit, hand held hammer, accelerometer, computer with required software to assess as-installed pile characteristics including mobilization of necessary manpower, equipments, materials etc. required for successful completion of the job. |
| 576 | STRINGING OF LINE CONDUCTOR & ACCESSORIES |
| 577 | Stringing of ASCR conductor as per approved sagging including installation of Insulators, hardware fittings, conductors accessories, jumpering arrangement, stringing of guard wire. This shall also include erection of PG clamp and connectors, jointing sleeves, danger plate & anti-climbing device etc. as required complete in all respect as per TS. |
| 578 | DOG ACSR conductor 6/1/4.09 Sqmm (3 wire line). |
| 579 | CROSS ARMS ( MILD STEEL) |
| 580 | 33 kv, 3 Wire, 3.05 M long cross arm made of channel of size 125 X 50 X 6 mm complete etc. As required. |
| 581 | 33kV 'Y'-Type Cross arm made of angle of size 50X50X6mm in radial structure of 3 arms of 0.9 M long 120 deg apart complete etc. as reuired. |
| 582 | GI STAY SET |
| 583 | Galvanized stay set complete with galvanised MS anchor plate of size 300X300X5mm, anchor rod of length 1800mm & dia 18mm along with stay wire, thimble, bow, guy strain insulator, nut & bolts etc. As required ( of all sizes). |
| 584 | CROSS BRACING (MILD STEEL) |
| 585 | Angle bracing set 3.6m long of sizes 65X65X6mm complete with accessories nut/bolts etc. As required. |
| 586 | SAFETY ALERT SYSTEM |
| 587 | Manufacturing, fabricating and supply of danger plate made of mild steel sheet of atleast 1.6mm thick and vitreous enameled white, with letyters, figures and the conventional skull and cross-bones in signal red colour on the front side for- |
| 588 | Danger Plate of size 250mm X 200 mm of thickness 3 mm. |
| 589 | Anti-Climbing devices with GI thornwire/Barbed wires. |
| 590 | GUARD BRACKET (MILD STEEL) |
| 591 | 33kV 3.5 M long Guard Bracket made of channel of size 100X50X6mm complete etc. As required. |
| 592 | Supply & Stringing of 8 SWG G.I Earth wire. |
| 593 | EARTHING SYSTEM |
| 594 | Earthing with 40 mm dia GI pipe 4.5 Mtr. Long with GI wire for pole earthing including salt charcoal etc. As required. |
| 595 | PAINTING & FINISHING WORKS |
| 596 | Supply& painting with 2 coats of red oxide paint & 2 coats of paints on poles/equipment/metal surfaces on full rate basis. |
| 597 | JUNGLE CLEARANCE |
| 598 | Cutting of trees including cutting of trunks, branches and removal of stems, branches from the cutting area, stacking of serviceable material at specified places at a distance not exceeding 1000Mfrom the cutting area along the RoW corridor of sub-transmission line. |
| 599 | Girth above 300mm to 600mm |
| 600 | Girth above 600mm to 1000mm |
| 601 | Girth above 1000mm |
| 602 | Cutting down of smaller trees of girth 300mm and below including all types of vegetation, grass bushes, shrubs, saplings and remains of them for ease of access for laying and stringing of conductors as well as to make footpath at pole/tower locations or any construction site as may be required. |
| 603 | HILL ROAD TRANSFORTATION |
| 604 | Transportation from Designated Bare Store (DBS) at Assam-Arunachal borders to the last Road head. (Weight & distance to be estimated). (100 MT x 46 km) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |