|
| 1 | GROUP 1: Rate contract for supply, fabrication and erection of mild steel canopy andallied works at Retail outlets under Guwahati DO for 2 years from the date of placement of LOA and extendable for a further period of upto one year on the same rates, terms and conditions on mutual consent |
| 2 | GROUP 2: Rate contract for supply, fabrication and erection of mild steel canopy andallied works at Retail outlets under Tinsukia DO for 2 years from the date of placement of LOA and extendable for a further period of upto one year on the same rates, terms and conditions on mutual consent |
| 3 | GROUP 3: Rate contract for supply, fabrication and erection of mild steel canopy andallied works at Retail outlets under Silchar DO for 2 years from the date of placement of LOA and extendable for a further period of upto one year on the same rates, terms and conditions on mutual consent |
| 4 | GROUP 4: Rate contract for supply, fabrication and erection of mild steel canopy andallied works at Retail outlets under Imphal DO for 2 years from the date of placement of LOA and extendable for a further period of upto one year on the same rates, terms and conditions on mutual consent |
| 5 | CANOPY RATE CONTRACT_GDO PALINS |
| 6 | Design, Supply, Fabrication and erection at the Site of pre-fabricated canopy at different retail outlet under IOAOD SO as per the specification and scope of work defined in technical bid.Item includes, , Canopy Fabrication, erection, painting all complete, gutters, Rain water down pipe, provision of roofing, false ceiling, metal fascia (including Indian Oil Lettering with retro-reflective stickers), provision of cables for canopy lights & spreaders and backlit Indian Oil from panel room, provision for rain water gutter with downtake pipes. The job also includes painting of canopy structures & columns etc as per specification. Foundation cost (per column), LED lights, u/g drainage system (per Canopy) are payable separately under items below . No extra payment shall however be made for cost incurred towards minor repair in case of already built foundation. |
| 7 | (a) Canopy Size upto 140 SQM |
| 8 | (b) Canopy Size more than 140 SQM |
| 9 | LED lights |
| 10 | Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 100 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineerin- charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 11 | Construction of foundation for canopy |
| 12 | Construction of foundation for canopy including earth work, Brick Flat Soling, PCC, RCC, back filling with sand, foundation bolt etc. as per approved drawings & specification including all complete, & Construction of underground drainage system including NP2 class RCC hume pipe and inspection chamber with MS cover plate etc. all complete |
| 13 | CANOPY RATE CONTRACT_GDO HILLS |
| 14 | Design, Supply, Fabrication and erection at the Site of pre-fabricated canopy at different retail outlet under IOAOD SO as per the specification and scope of work defined in technical bid.Item includes, , Canopy Fabrication, erection, painting all complete, gutters, Rain water down pipe, provision of roofing, false ceiling, metal fascia (including Indian Oil Lettering with retro-reflective stickers), provision of cables for canopy lights & spreaders and backlit Indian Oil from panel room, provision for rain water gutter with downtake pipes. The job also includes painting of canopy structures & columns etc as per specification. Foundation cost (per column), LED lights, u/g drainage system (per Canopy) are payable separately under items below . No extra payment shall however be made for cost incurred towards minor repair in case of already built foundation. |
| 15 | (a) Canopy Size upto 140 SQM |
| 16 | (b) Canopy Size more than 140 SQM |
| 17 | LED lights |
| 18 | Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 100 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineerin- charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 19 | Construction of foundation for canopy |
| 20 | Construction of foundation for canopy including earth work, Brick Flat Soling, PCC, RCC, back filling with sand, foundation bolt etc. as per approved drawings & specification including all complete, & Construction of underground drainage system including NP2 class RCC hume pipe and inspection chamber with MS cover plate etc. all complete |
| 21 | CANOPY RATE CONTRACT_TDO PALINS |
| 22 | Design, Supply, Fabrication and erection at the Site of pre-fabricated canopy at different retail outlet under IOAOD SO as per the specification and scope of work defined in technical bid.Item includes, , Canopy Fabrication, erection, painting all complete, gutters, Rain water down pipe, provision of roofing, false ceiling, metal fascia (including Indian Oil Lettering with retro-reflective stickers), provision of cables for canopy lights & spreaders and backlit Indian Oil from panel room, provision for rain water gutter with downtake pipes. The job also includes painting of canopy structures & columns etc as per specification. Foundation cost (per column), LED lights, u/g drainage system (per Canopy) are payable separately under items below . No extra payment shall however be made for cost incurred towards minor repair in case of already built foundation. |
| 23 | (a) Canopy Size upto 140 SQM |
| 24 | (b) Canopy Size more than 140 SQM |
| 25 | LED lights |
| 26 | Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 100 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineerin- charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 27 | Construction of foundation for canopy |
| 28 | Construction of foundation for canopy including earth work, Brick Flat Soling, PCC, RCC, back filling with sand, foundation bolt etc. as per approved drawings & specification including all complete, & Construction of underground drainage system including NP2 class RCC hume pipe and inspection chamber with MS cover plate etc. all complete |
| 29 | CANOPY RATE CONTRACT_TDO HILLS |
| 30 | Design, Supply, Fabrication and erection at the Site of pre-fabricated canopy at different retail outlet under IOAOD SO as per the specification and scope of work defined in technical bid.Item includes, , Canopy Fabrication, erection, painting all complete, gutters, Rain water down pipe, provision of roofing, false ceiling, metal fascia (including Indian Oil Lettering with retro-reflective stickers), provision of cables for canopy lights & spreaders and backlit Indian Oil from panel room, provision for rain water gutter with downtake pipes. The job also includes painting of canopy structures & columns etc as per specification. Foundation cost (per column), LED lights, u/g drainage system (per Canopy) are payable separately under items below . No extra payment shall however be made for cost incurred towards minor repair in case of already built foundation. |
| 31 | (a) Canopy Size upto 140 SQM |
| 32 | (b) Canopy Size more than 140 SQM |
| 33 | LED lights |
| 34 | Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 100 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineerin- charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 35 | Construction of foundation for canopy |
| 36 | Construction of foundation for canopy including earth work, Brick Flat Soling, PCC, RCC, back filling with sand, foundation bolt etc. as per approved drawings & specification including all complete, & Construction of underground drainage system including NP2 class RCC hume pipe and inspection chamber with MS cover plate etc. all complete |
| 37 | CANOPY RATE CONTRACT_SDO PALINS |
| 38 | Design, Supply, Fabrication and erection at the Site of pre-fabricated canopy at different retail outlet under IOAOD SO as per the specification and scope of work defined in technical bid.Item includes, , Canopy Fabrication, erection, painting all complete, gutters, Rain water down pipe, provision of roofing, false ceiling, metal fascia (including Indian Oil Lettering with retro-reflective stickers), provision of cables for canopy lights & spreaders and backlit Indian Oil from panel room, provision for rain water gutter with downtake pipes. The job also includes painting of canopy structures & columns etc as per specification. Foundation cost (per column), LED lights, u/g drainage system (per Canopy) are payable separately under items below . No extra payment shall however be made for cost incurred towards minor repair in case of already built foundation. |
| 39 | (a) Canopy Size upto 140 SQM |
| 40 | (b) Canopy Size more than 140 SQM |
| 41 | LED lights |
| 42 | Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 100 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineerin- charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 43 | Construction of foundation for canopy |
| 44 | Construction of foundation for canopy including earth work, Brick Flat Soling, PCC, RCC, back filling with sand, foundation bolt etc. as per approved drawings & specification including all complete, & Construction of underground drainage system including NP2 class RCC hume pipe and inspection chamber with MS cover plate etc. all complete |
| 45 | CANOPY RATE CONTRACT_SDO HILLS |
| 46 | Design, Supply, Fabrication and erection at the Site of pre-fabricated canopy at different retail outlet under IOAOD SO as per the specification and scope of work defined in technical bid.Item includes, , Canopy Fabrication, erection, painting all complete, gutters, Rain water down pipe, provision of roofing, false ceiling, metal fascia (including Indian Oil Lettering with retro-reflective stickers), provision of cables for canopy lights & spreaders and backlit Indian Oil from panel room, provision for rain water gutter with downtake pipes. The job also includes painting of canopy structures & columns etc as per specification. Foundation cost (per column), LED lights, u/g drainage system (per Canopy) are payable separately under items below . No extra payment shall however be made for cost incurred towards minor repair in case of already built foundation. |
| 47 | (a) Canopy Size upto 140 SQM |
| 48 | (b) Canopy Size more than 140 SQM |
| 49 | LED lights |
| 50 | Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 100 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineerin- charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 51 | Construction of foundation for canopy |
| 52 | Construction of foundation for canopy including earth work, Brick Flat Soling, PCC, RCC, back filling with sand, foundation bolt etc. as per approved drawings & specification including all complete, & Construction of underground drainage system including NP2 class RCC hume pipe and inspection chamber with MS cover plate etc. all complete |
| 53 | CANOPY RATE CONTRACT_IDO |
| 54 | Design, Supply, Fabrication and erection at the Site of pre-fabricated canopy at different retail outlet under IOAOD SO as per the specification and scope of work defined in technical bid.Item includes, , Canopy Fabrication, erection, painting all complete, gutters, Rain water down pipe, provision of roofing, false ceiling, metal fascia (including Indian Oil Lettering with retro-reflective stickers), provision of cables for canopy lights & spreaders and backlit Indian Oil from panel room, provision for rain water gutter with downtake pipes. The job also includes painting of canopy structures & columns etc as per specification. Foundation cost (per column), LED lights, u/g drainage system (per Canopy) are payable separately under items below . No extra payment shall however be made for cost incurred towards minor repair in case of already built foundation. |
| 55 | (a) Canopy Size upto 140 SQM |
| 56 | (b) Canopy Size more than 140 SQM |
| 57 | LED lights |
| 58 | Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 100 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineerin- charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 59 | Construction of foundation for canopy |
| 60 | Construction of foundation for canopy including earth work, Brick Flat Soling, PCC, RCC, back filling with sand, foundation bolt etc. as per approved drawings & specification including all complete, & Construction of underground drainage system including NP2 class RCC hume pipe and inspection chamber with MS cover plate etc. all complete Please Enable Macros to View BoQ information |