| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point:- |
| 3 | Medium Point:- |
| 4 | Long Point:- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 8 | 2 X 1.5 sq mm:- |
| 9 | 2 X 2.5 sq mm:- |
| 10 | 2 X 4 sq mm:- |
| 11 | 4 X 6 sq mm: |
| 12 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 13 | 1 X 1.5 sq mm:- |
| 14 | 1 X 2.5 sq mm:- |
| 15 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required:- |
| 16 | 19/20 mm dia:- |
| 17 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies ,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 18 | Supplying and fixing of the following electrical accessories i/c necessary conn. etc. as reqd. |
| 19 | Electronic 5 step fan regulator |
| 20 | Supplying and fixing of recessed mounting CRCA powder coated housing 2ft x 2 ft decorative 36 watt LED panel light fixture with integral driver, inbuild SPD >= 3 kV and high quality polycarbonate diffuser having and THD <=10%, luminous efficacy of 100 lumen/watt & life expectancy of 50,000 burning hours including ncessary connection etc as required:- (with LM79 report from NABL accredited lab):- |
| 21 | Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required. |
| 22 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 23 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 24 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 25 | Surface mounted round/ Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 26 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 27 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 28 | Supply and fixing of surface mounted 18/20 watt LED tube luminaire with powder coated finished 0.5 mm thick CRCA steel sheet housing including 1 no 18/20 watt LED tube having minimum system lumen output of 120 Lumens/watt & life expectancy of 50,000 burning hours with integral driver having 2 kV SPD and polycarbonate diffuser including connection etc as required (with LM79 report from NABL accredited lab):- |
| 29 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with precise street optic lens with heat resistant tempered glass/diffuser protection with IP66 and IK08/IK10 impact resistant including necessary connection etc. as required (50000 burning hours, THD ≤ 10% and minimum lumen output of 120 lm/watt with LM79 report from NABL accredited lab):- |
| 30 | 80 watt LED street light fixture with integral driver and secondary lens :- |
| 31 | Supplying and laying of following sizes XLPE insulated PVC sheathed Aluminium conductor Un-armoured cable including necessary connection etc as required. |
| 32 | 3 core 4 Sq mm |
| 33 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
| 34 | 40 amps DP isolator:- |
| 35 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 36 | 40 mm dia |
| 37 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : - |
| 38 | 4/6 sq mm |
| 39 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - |
| 40 | 1.5 sqmm - 4 sqmm Cable:- |
| 41 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):- |
| 42 | Centering shuttering including struttings, propping etc.and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank:- |
| 43 | 6 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ):- |
| 44 | Neat cement punning:- |
| 45 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 46 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 47 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 48 | Providng and laying 15mm dia (medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 49 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 50 | 32 amps 415 volts TPN main switch (rewireable):- |
| 51 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 52 | 32 amps kitkat porcelain fuse unit with base(rewireable):- |
| 53 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB /Isolator/ RCCB(SP/SPN/DP/TP/TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 54 | (2+6) / 8 way SPN MCB DB (double door):- |
| 55 | (2+10) / 12 way SPN MCB DB (double door):- |
| 56 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as require:- |
| 57 | 6 to 32 amps SP MCB:- |
| 58 | 6 to 32 amps DP MCB:- Please Enable Macros to View BoQ information |