| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK : SPECIAL REPAIRS TO WIRE DUCT AT CERTAIN LOCATIONS AT HQTC (U) BANGALORE CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | S&F TRAY PANEL SCREW type system (at the site) with Aluminium composite panel of approved plain colour or wood grain printed on interior walls, columns, ducting of wires making shutters, MS structure, ceiling, coping, slab projectons at all heights and elevation over aluminium framework and making sliding doors or equivalent . The aluminium composite panel should 4 mm thick consist of 3mm thick thermoplastic core of anti oxidant LDPE sandwitched between 2 skins of 0.5mm thick aluminium alloy sheet making a total panel thickness of 4mm. The external surface shall be finshed with PVDF based coating on the top side and service coating on the reverse side shall be with a polymer paint all including main duct with openable or sliding doors including all fittings complete all as specified and directed. Notes:- The system shall be fitted over Aluminium. sub frames and cleats shall be fixed to the masonry/ RC walls/ MS structure with necessary clamps, galvanized M.S brackets and anchor fasteners. All clamps and brackets shall be hot dip galvanized minimum 80 microns thick and shall conform to IS: 4759-1996. Any other acessories such as fastening straps, nuts, bolts, rivets, washers, etc other than anchor system shall be in Indian standard grade. All joints of ACP must be sealed with approved sealent of approved colour. Sealant Make DOW CORNING 789 weather sealant. Rate shall quoted shall include to provide open cell polyethylene backer rods, weather sealant and all materials and labour inclusive. Aluminium section shall be measured and paid separately |
| 3 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 4 | M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement. including mixing of water proofing compound wherever required as per manufacturers instructions and complete all as specified and directed. Note: WPC shall be measured & paid separately |
| 5 | M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in Cement mortar 1:6, finished even and smooth with out using extra cement complete all as specified and directed. |
| 6 | M&L fo Rendering 10 mm thick on fair faces of concrete surfaces in cement mortar 1:3 in ceiling of chajja,roof projection,shelve etc and finished even and smooth without using extra cement complete all as specified and directed. |
| 7 | M&L for preparing new plastered surfaces and applying three coats of white wash on surfaces of ceilings complete all as specified and directed. |
| 8 | M&L for preparing old plastered surfaces and applying two coats of white wash on surfaces of ceilings complete all as specified and directed. |
| 9 | M&L for preparing old plastered surfaces and applying one coat of cement base paint through mechanical means complete all as specified and directed. |
| 10 | M&L for Preparing new plastered surfaces of walls and applying through mechanical means two coats of oil bound distemper over a coat of alkali resistant primer over and including applying 2 mm thickness plaster of paris putty to prepare the surface even and smooth complete all as specified and directed. |
| 11 | Complete removal of existing treatment of old plastered surfaces of walls and applying through mechanical means two coats of oil bound distemper over a coat of alkali resistant primer over and including applying 1 mm thickness plaster of paris putty to prepare the surface even and smooth complete all as specified and directed. |
| 12 | S&F Rigid PVC trunking white colour of 195mm x 50mm along with bodies & with flexible cover 185 mm as per OEM fixing on stone walls/ brick masonry walls/ ceilings/ floors etc. for running of all type of service/ miscellaneous cables complete with fitting such as joints/ Tee/ elbow/ coupler etc, including taking down old PVC cable trunking complete all as specified & directed.Make : Legrand, Cat No 010452 ( Body) and 010526 ( Cover ) or Techno commercially equivalent in Generic,Polycab. |
| 13 | S&F PVC divider suitable for 195 X50mm trunking including taking down old PVC cable Trunking complete all as specified & directed.Make : Legrand, Cat No : 075609 or Techno commercially equivalent in Generic,Polycab. |
| 14 | S&F Suitable End cap of size 195X50mm trunking including taking down old PVC cable Trunking complete all as specified & directed. |
| 15 | S&F Cover joint suitable for 195X50mm trunking including taking down old PVC cable Trunking complete all as specified & directed. |
| 16 | S&F Body joint suitable for 195 X50mm trunking including taking down old PVC cable Trunking complete all as specified & directed. |
| 17 | S&F Flat angle suitable for 195 X50 mm trunking including taking down old PVC cable Trunking complete all as specified & directed. |
| 18 | S&F Rigid PVC trunking white colour of 80 mm x 50mm with a long bodies & with flexible cover 65mm as per OEM fixing on stone walls/ brick masonry walls/ceilings / floors etc. for running of all type of service/ miscellaneous cables complete with fitting such as joints/ Tee/ elbow / coupler etc, including taking down old PVC cable Trunking all as specified and directed. Make : Legrand, Cat No 010452 (Body) and 010526 (Cover) or Techno commercially equivalent in Generic,Polycab. |
| 19 | S&F heavy grade PVC Casing & Capping of size 40 mm dia ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc complete all as specified & directed. |
| 20 | S&F Sheet metal enclosure for DB's double door SPN, 12 ways when MCBs to be used single pole and neutral, deep drawn with 200 Amps rated copper bus bar 230 Volt, complete all as specified & directed. |
| 21 | S&F MCB SPN, 40 Amps, 230 V, C- series with breaking capacity of 10 KA complete all as specified & directed. |
| 22 | S&F MCB SP, 6-32 Amps, 230V, C- series with breaking capacity of 10KA complete all as specified & directed. |
| 23 | S&F Sheet metal enclosure for DB's double door VTPN 04 ways including 01 No MCCB 125 Amp 4 pole 16 KA to be used as incomer and outgoing as MCB single pole, deep drawn with 200 Amps rated copper bus bar 415 V, complete all as specified & directed. |
| 24 | S&F Sheet metal enclosure for DB's double door VTPN 08 ways including 01 No MCCB 125 Amp 4 pole 16 KA to be used as incomer and outgoing as MCB single pole, deep drawn with 200 Amps rated copper bus bar 415 V, complete all as specified & directed. |
| 25 | S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 32 Amps complete all as specified & directed. |
| 26 | M&L for sub main wiring with two single core 2.5 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Capping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 2.5 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed. Note-Two runs of 2.5 sqmm single core cable and one run of 2.5 sqmm earth wire including PVC casing & capping together shall be measured as one unit. |
| 27 | M&L for sub main wiring with two single core 4.00 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Capping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 4.00 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed.Note-Two runs of 4.00 sqmm single core cable and one run of 4.00 sqmm earth wire including PVC casing & capping together shall be measured as one unit. |
| 28 | M&L for sub main wiring with two single core 6.00 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Capping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 6.00 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed by Engineer-in-Charge. Note-Two runs of 6.00 sqmm single core cable and one run of 6.00 sqmm earth wire including PVC casing & capping together shall be measured as one unit. |
| 29 | M&L for sub main wiring with four single core 4.00 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Capping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 4.00 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed. Note- Four runs of 4.00 sqmm single core cable and one run of 4 sqmm earth wire including PVC casing & capping together shall be measured as one unit. |
| 30 | M&L for sub main wiring with four single core 6.00 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Capping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 6 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed. Note- Four runs of 6.00 sqmm single core cable and one run of 6.00 sqmm earth wire including PVC casing & capping together shall be measured as one unit. |
| 31 | M&L for sub main wiring with four single core 10.00 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Capping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 10.00 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed. Note- Four runs of 10.00 sqmm single core cable and one run of 10.00 sqmm earth wire including PVC casing & capping together shall be measured as one unit. |
| 32 | M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron wire 4 mm dia as earth lead up to test point with suitable size GI nuts/bolts, washers,check nut and brazed properly up to main board,LT panel etc and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10 mm thick with hinged and frame of angle iron 25x25x6mm with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI protection pipe 15 mm bore up to main board complete all as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed. Notes: (i) The unit rate includes 15 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes galvanised iron wire 4 mm dia from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthing is recorded more than 3 ohms then the earthing shall be re done by the contractor without any extra cost to the Govt till desired result is obtained (iv) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge / JE E/M and proper record shall be maintained duly signed by all concerned. (v) Earth resistance tester shall be provided by the contractor. |
| 33 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing 4 mm dia galvanised iron or steel wire complete all as specified & directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |