| 1 | SH-I:- Dismantling & reinstallation of Electrical Pump at Mundka Metro stationDismantling of Semi permanent wiremeshstructure including cutting of 40x40x6mm legfrom CC Foundation and cutting it in propersize including cleaning of existing place. (12feet x 15 feet) |
| 2 | Dismantling of existing Galvanized Ironprofile sheet having thickness minimum0.5mm with the help of suitable T&P. (10 feetx 15 feet |
| 3 | Dismantling of common header made by100/150/200 mm dia MS'C' class pipe forexisting pump including dismantling of NRV& Sulice valve if avavlible at site. |
| 4 | Dismantling of following rating centrifugal pumps including connections testing completion etc. as required and as per direction of Engineer in charge. |
| 5 | 25 HP |
| 6 | Reinstallation of following rating centrifugal pumps including connections testing completion etc. as required and as per direction of Engineer in charge. |
| 7 | 25 HP |
| 8 | Supplying and Fixing Anti vibration mounting pads suitable for 25HP including testing of commissioning etc. asrequired. |
| 9 | Supplying and Laying of following size of Multicore flexible PVC Insulated & PVC Sheathed submersible flat cable of 1.1KVgrade in well/On surface/ in ground i/c testing etc complete as required. as & whenreqd. as per the irection of engineer incharge. |
| 10 | 3 Core x 16 Sq.mm |
| 11 | Installation of feeder panel with suitable size of CC/MS Fabricated foundation grouting minimum 45 cm in CC foundation (in position 1:2:4 reinforced cement concrete) including connection of all existing MCB/MCCB to the existing starter panel & if any mishappening will occur during entire work only the agency will be the responsible. |
| 12 | Supplying, Installation, Testing & Commissioning of following rating Fully automatic Star Delta starter Submersible /Centrifugal pump controller with single phase preventer in sheet steel enclosure of relay following range ( as per pump capacity) with voltmeter & ammeter suitable for 415 Volt 50 Hz AC Supply etc as required. |
| 13 | 30 HP with Relay Range 30-50 A |
| 14 | Supplying and making outdoor end termination withcast resin compound including aluminium lugs andother jointing materials for following size of PVCinsulated and PVC sheathed / XLPE aluminiumconductor cable of 1.1 KV grade as required. |
| 15 | 3.5 X 150 sq. mm |
| 16 | Supplying, Installation, Testing &Commissioning of 4 Pole Change Over Switch with enclosure, suitable to work on 415V, 50 Hz AC Supply i/c Connection ofcables at all ree terminals etc. completed asrequired. as & when eqd. s per the directionof engineer in charge. |
| 17 | 250 A |
| 18 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required |
| 19 | 150mm dia |
| 20 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required |
| 21 | 150mm Dia |
| 22 | Providing, laying, testing & commissioning of 'C'class heavy duty MS pipe conforming to IS1239/Class -II of IS: 3589 including Welding, fittingslike elbows, tees, flanges, tapers, nuts bolts, gasketsetc. and fixing the pipe on the wall/ceiling withsuitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required |
| 23 | 150 mm dia |
| 24 | 300 mm dia (wall thickness 7 mm) |
| 25 | Supplying & Fixing of Following items for fabrication of Common Header for Centrifugal pump of Suitable capacity |
| 26 | 300mm dia MS Dead End Plate |
| 27 | 150mm dia MS flange |
| 28 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 29 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 30 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 31 | Group C |
| 32 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 33 | 3 x 2.5 sq. mm |
| 34 | 3 x 4 sq. mm |
| 35 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 36 | 25 mm |
| 37 | Supplying, Installation, Testing and Commissioning of 300 mm Sweep heavy duty metal body fresh air exhaut fan minimum 1400 rpm including louvers and shutter, fixing with suitable arrangement, connection with 1.5 sq.mm. FRLS PVC insulated wire complete etc. as reqd |
| 38 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 39 | 6 Module (200mmX75mm) |
| 40 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 41 | 15/16 A switch |
| 42 | 6 pin 15/16 A socket outlet |
| 43 | Supplying and fixing of aluminium composite (ACP) sheet having minimum thickness 6mm and fixing on temporary wall by proper Nut-Bolt, washer and dash fastner as per direction of Engineer-in-charge. |
| 44 | Credit back of following items :- |
| 45 | Wiremesh Structure |
| 46 | GI Profile Sheet |
| 47 | Common Header |
| 48 | 150mm NRV/Sulice valve |
| 49 | Dismantle assorted size MS Pipe 100/150/200mm |
| 50 | SH-II :- Construction of Semi permanent structure and SITC of Monoblock pump for dewatering system at MayapuriFabricating, Supplying & Fixing wire mesh protection frame work made out of 40 mm x 6 mm thick angle & \\"T\\" strengthened with intermediate members of MS flat iron of size 30 mm x 5 mm thick welded at a distance of 30 cm horizontally & vertically and duly welded with wire mesh of size 75 mm x 25 mm made with 6 SWG wire mash of size 75 mm x 25 mm made with 6 SWG wire on all sides and top i/c providing and fixing of double door gate with double locking arrangement ( Two Nos. sliding bolts and One No go down lock) having 0.5 mtr. long legs of 40 mm x 40 mm x 6 mm thick angle iron, duly grouted in cement concrete foundation ration 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate), up to suitable depth painting with one coat of red oxide & Two coats of synthetic enamel paint of approval colour and shade and having provision of Central lock etc. complete as reqd. |
| 51 | Pdg & fixing 24 SWG corrugated GI Sheet on the top of the roof existing wiremesh enclosure with the help of 'J' hooks etc complete as reqd. |
| 52 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the Engineer-in-charge; for the following grades of concrete. Note : Extra cement upto 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 53 | Concrete of M25 grade with minimum cement content of 300 kg /cum |
| 54 | Providing, laying, testing & commissioning of 'C'class heavy duty MS pipe conforming to IS1239/Class -II of IS: 3589 including Welding, fittingslike elbows, tees, flanges, tapers, nuts bolts, gasketsetc. and fixing the pipe on the wall/ceiling withsuitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required |
| 55 | 100 mm Dia |
| 56 | 150 mm Dia |
| 57 | 200 mm dia (wall thickness 6.3 mm) |
| 58 | Steel work in built up tubular (round, square or rectangular hollow tubes etc), trusses etc. including cutting, hosting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete as reqd. |
| 59 | Hot finished welded type tubes |
| 60 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required |
| 61 | 100mm Dia |
| 62 | Supplying & Fixing of Following items for fabrication of Common Header for Centrifugal pump of Suitable capacity |
| 63 | 200mm Dead End Plate |
| 64 | 100mm Dia MS Flange |
| 65 | 150mm Dia MS Flange |
| 66 | Supplying, Installation, Testing & Commissioning of following rating Fully automatic Star Delta starter Submersible /Centrifugal pump controller with single phase preventer in sheet steel enclosure of relay following range ( as per pump capacity) with voltmeter & ammeter suitable for 415 Volt 50 Hz AC Supply etc as required. |
| 67 | 12.50/15 HP with Relay Range 13-22 A |
| 68 | Supplying Installation Testing and commissioning of 12.5 HP/9.3 KW Rating Centrifugal Pump having following specifications. (A) Suction Size - 100mm (B) Deliver Size - 100mm ( C) Impeller - CI (D) Gland Packing - Sealing ( E) C-40 Shaft (F) IP Rating - IP44 (G) Class of Insulation - F |
| 69 | Supplying Installation Testing and commissioning Self Priming 1 HP/0.75KW Monobloc Pumpset for priming of all the existing Centrifugal Pumpset installed in various pump rooms having following specifications. (A) Suction Size - 40mm (B) Deliver Size - 40mm ( C) Impeller - CI (D) Gland Packing - Sealing ( E) C-40 Shaft (F) IP Rating - I (G) Insulation Class - B |
| 70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 40 mm nominal outer dia. Pipes. |
| 71 | Providing and fixing of flexible PVC Rainforce Pipe 32-40mm dia & connection with existing monoblock pumpset |
| 72 | Supplying and Laying of following size of Multicore flexible PVC Insulated & PVC Sheathed submersible flat cable of 1.1KV grade in well/On surface/ in ground i/c testing etc complete as required. as & when reqd. as per the direction of engineer in charge. |
| 73 | 3 Core x 10 Sq.mm |
| 74 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 75 | Group C |
| 76 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 77 | 3 x 2.5 sq. mm |
| 78 | 3 x 4 sq. mm |
| 79 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 80 | 25 mm |
| 81 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 82 | 6 way , Double door |
| 83 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 84 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 85 | Supplying, Installation, testing and commissioning of 300mm sweep Fresh Air Exhaust Fan Plastic Body of single phase, with louver & shutter in the existing opening, making good the damage, connection, testing, commissioning etc as required. |
| 86 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 87 | 6 Module (200mmX75mm) |
| 88 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 89 | 5/6 A switch |
| 90 | 15/16 A switch |
| 91 | 3 pin 5/6 A socket outlet |
| 92 | 6 pin 15/16 A socket outlet |
| 93 | Supplying and fixing of 3 Pin 16 A Plug Top suitable for 240 V AC ISI Marked etc complete as required as per direction of Engineer-in-charge. |
| 94 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 95 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 96 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 97 | Single pole |
| 98 | Double pole |
| 99 | Supplying of Power contactor 4 pole , 95 A, 415 volt having 2 NO+2NC contact (MNX-95/similar make). |
| 100 | Supplying of Power contactor 4 pole , 110 A, 415 volt having 2 NO+2NC contact (MNX-110/similar make). |
| 101 | Supplying of Astro Mini Timer in the existing cubical Panel with suitable connection etc as reqd. Please Enable Macros to View BoQ information |