| 1 | [13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate] |
| 2 | [20.103.2]Development of tube well according to clause 9.3 of IS: 2800-1991 (Part-I) as amended up to date and specifications attached and as directed by the Engineer-in-charge of the work including the cost of all consumable stores, fuel, oil, compressors, pumps and machinery etc. as required for the work. 2. Compressor 800cfm x 550 psi [Through Rate] |
| 3 | [20.106.1]Supply, testing and lowering (ERW) electric resistance welded M.S. pipes with MS threaded socket as per IS 4270 as amended up to date, duly ISI marked for housing pipe in 4 to 7 metres random length into bore well with 88.90mm of threaded ends (8 threads to an inch or 25.40 mm) manufactured out of 8mm thick MS plates with required numbers of MS socket 177.8mm with inside thread to match the pipe threads and made out of MS plate in to borehole in vertical position including cost of all tools and plants, complete in all respects to the satisfaction of Engineer-in-charge, including cost of all cutting, threading of pipe, welding, where required and all sockets. The pipe shall be painted with anti corrosive paint and covered tightly with polythene of following sizes: 1. 200x6.4mm [Through Rate] |
| 4 | [20.107.1.2]Supply, testing and lowering of ISI marked all welded stainless steel screen (SS304) cage Type V-Wire Wound Screens in bore wells conforming to IS:8110 and compositions of material as per IS:1012, outer dia 221mm equivalent thickness required as per code, tensile load 14000 kg minimum and ring thickness as per IS code of following sizes:- 1.2. Stainless Steel Screens 200x8.0x0.75mm [Through Rate] |
| 5 | [20.11.2]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 2. 100 mm i/d [Through Rate] |
| 6 | [20.114.3]Supplying erection, testing of fullyautomatic electric control panel board forT/Wells in Pump Chamber consisting ofMS sheet of thickness 14 gauge dulypainted box type floor mounted made ofangle Frame containing 1 no. fullyautomatic air brake starter suitable forMotor of the following capacity, Minswitch of suitable range with HRC fuse, 1no. volt meter (0 to 500 volts), 1 No.Amp. Meter of 0 to 100 amp. 3 sets ofindicating lamp capacitor of suitablecapacity and 1 no. single phase preventerswith the timer switch including wiring inpanel board and suitable electric energymeter wiring in Electric Control PanelBoard complete in all respect as perspecification given in Schedule No. II,Including MCB, suitable, Capacitor,Wooden Box etc as per siterequirement complete in all respect. 3. 20 HP Motor [Through Rate] |
| 7 | [20.54.4]Providing GI pipes class B marked with IS: 1239 in 3.05 m length, their threading and welding with flanges (Heavy Duty) on both sides, jointing with nuts and bolts ( ‘W’ make), rubber gaskets , lowering into Tube wells and testing including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. 4. 100 mm i/d [Labour Rate] |
| 8 | [20.59.2]Providing and fixing Cast Iron Detachable Joints class-25 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 2. 100mm i/d CID Joint [Through Rate] |
| 9 | [20.63.1]`Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade SandS pipes as per 15:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/W to be measured and paid separately.` 1. 100 mm i/d [Through Rate] |
| 10 | [20.68.1]Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths Ductile Iron (DI) standard specials plain /flanged/ socketed confirming to IS9523-2000 with rubber ring (EPDM/SBR) joints such as tees, bends, tapers, caps etc. with in trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 1. Up to 300mm dia [Through Rate] |
| 11 | [20.69.1]Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths cast iron (CI) standard specials plain /flanged/ socketed confirming to IS13382 with rubber ring, nut bolts and rubber sheet such as tees, bends, tapers, caps etc. complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 1. Up to 300mm dia [Through Rate] |
| 12 | [20.96.1]Water Supply installation of shallow/Medium/Deep tubewells as per IS 2800:1991 Drilling of 609.60mm dia bore by hydraulic rotary drilling (reverse circulation method) according to ISI specification No. 2800-1991 (Part-I) as amended up to date and modified to extent of the specification attached with this schedule of items of work in all kinds of soils and boulders up to 125 mm dia except rocky strata including the cost of all consumable stores, fuel, oil, soil stabilizing material and transportation of rig and other accessories to the site of proposed bore and back including cost of lowering of all size of casing pipe while boring and extracting the same against earth friction etc. 1. Drilling from 0 metre but up to 200 metre BGL [Through Rate] |
| 13 | [20.99.Zone-III]Water Supply installation of shallow/Medium/Deep tubewells as per IS 2800:1991 Supplying and packing graded gravel in bore well of size as per ISI 4097, as amended up to date (Grade A, 2.25mm to 3.35mm) and specification attached with this schedule of item of work. The gravel should be free from dust, dirt or vegetable matters. Packing to be done from reducer to the bottom of liner all around in the bore with Margin above reducer in the housing pipe as per the requirement and will be packed after liner and housing pipes have been lowered and suitably clamped. Thickness and size of the gravel packing will be designed and directed by the Engineer-in-charge strictly as per relevant ISI. Zone-III. Sonipat, Panipat, Jind, Fatehabad, Sirsa, Hisar [Through Rate] |
| 14 | [22.160.1]Providing and laying SandS Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : 1. 100 mm dia Ductile Iron Class K-7 pipes [Through Rate] |
| 15 | [24.13.30]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 30. 25 Sq mm 3.5 core (Arm.) [Through Rate] |
| 16 | [3.1.18]By Mechanical Transport including loading, unloading and stacking 18. Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead up to 10 km for all lifts, complete as per directions of Engineer-in-charge. [Rate] |
| 17 | [33.11.3]Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumastic paint of approved brand and manufacture, including hire and labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer -in-charge. 3. 200 mm nominal size dia [Through Rate] |
| 18 | [33.16.3]Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 3. 200 mm dia [Through Rate] |
| 19 | [33.17.3]Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 3. 200 mm clamp [Through Rate] |
| 20 | [33.18.3]Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 3. 200 mm dia [Through Rate] |
| 21 | [4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate] |
| 22 | [5.23.1]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) [Through Rate] |
| 23 | [6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 24 | [9.31]Providing and fixing Hi, Rib profiled sheets 0.60mm TT (Total Thickness) (only ± 0.2mm tolerance allowed) Hi Tensile galvalume/Zincalume steel sheet of the approved make having a hot dip metallic Zinc-Aluminium alloy (AZ-150) coating of minimum (150 gms/sqm) with 550 Mpa yield strength of approved blue colour (RAL-5012) the colour coating shall be as per IS 15965 of SMP or Super Durable Polyester Paint XRW fixed with hex head self-drilling screw sloping roof without curvature as per approved specification, drawing and design of the Corporation [Through Rate] Please Enable Macros to View BoQ information |