| 1 | Dewatring naala by using 5 to 10HP Pump …............Including all complete. |
| 2 | Excavation in mud, sludge and silt loam, clay or and including lift upto 1.50m and lead up to 30m and including filling watering and ramming of excavated earth in to the reenches or in to the space between the bulilding and the side of foundation ……………................................. allcomplete |
| 3 | Excavation in foundation in ordinary soil or silt (loam, clay or sand) including lift upto 1.50m and lead up to 30m and including filling watering and ramming of excavated earth in to the trenches or in to the space between the building and the side of foundation trenches or in to the plinth and removal and disposal of surplus earth as directed by the Engineer in charge up to a distance of 30m from the foundation trenches. (PWD SOR 2025-26, Chepter-4, Item No.01 Spec- 251 ) |
| 4 | Disposal of malba from site with cartage up to 8km distance including loading & unloading, T&P etc. required for proper of work as direction by Engineer-In-Charge. (PWD SOR 2025-26, Chapter-3, Item No. 231a ) |
| 5 | Providing and laying cement concrete in 1:4:8 (1 cement: 4coarse sand :8 graded stone aggregate 40mm norminal size ) including supply of all materials, labour and T&P etc. (PWD SOR 2025-26 Chapter No-06 SI No. 3 Spec. No. 4.1) |
| 6 | RCC work Providing and laying in position specified grade of reinforced cement concrete in Raft foundation, including the cost of centering, shuttering, finishing and excluding reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (PWD SOR 2025-26, Chepter-5, Item No.9 Spec. no. 5.1). |
| 7 | R.C.C work in Wall (any thickness) including attached plasters, buttresses, plinth and string courses, fillers, columns, pillars, abutments, post and struts etc. including the cost of centering, shuttering, finishing and excluding reinforcement All work up to plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) upto plinth level (PWD SOR 2025-26, Chepter-5, Item No.9 Spec. no. 5.2) |
| 8 | Reinforced cement concrete work in beams, lintels, roofs having balconies, shelves, chajjas, bands, staircases and spiral stair cases above plinth level up to floor five level, including cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). (PWD SOR 2025-26, Chapter-5, Item No.12) |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. including cost of centering, shuttering, finishing and excluding reinforcement :1:1.5:3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).(PWD SOR 2025-26, Chapter-5, Item No.11 Spec. no. 5.2) |
| 10 | M-15 Brick work in 1:4 Cement and Coarse sand mortar in foundation and plinth including supply of all materials, labour and tools and plants, etc. required for proper completion of the work. (SOR/ PWD 2025-26 Chapter No. 6 SI No. 2)) |
| 11 | M-150 ( Non Modular)Brick work in 1:4 Cement and Coarse sand mortar in foundation and plinth including supply of all materials, labour and tools and plants, etc. required for proper completion of the work add extra to item No.1 to 4 above for super structure above plinth level upto floor five level including necessary cutting and moulding of brick work as required and also including honey combed brick work in thickness of wall more than 12cm( PWD SOR 2025-26, chapter-5, SI No. 2+5) |
| 12 | 12 mm thick plaster with cement mortar in proportion of 1:4 cement & fine sand ( Dholpur sand Not less than in 1.25 FM) of single coat for interior plastering upto floor two level...... All complete.(PWD/SOR 2025-26 Chapter No-07 SI No. 2) |
| 13 | Finishing walls with putty approved brand and manufacture and of required shade on undercoated wall surface to give even shade over including curing.......................... etc all complete(new item chapter No. 8 ,SI. No. 31) |
| 14 | Finishing walls with exterior emulsion paint (Apex) of approved brand and manufacture and of required shade onundacorated wall surface to give even shade over @ 1.25Ltr/10sqm including one coat of primer applid @0.75Ltr/10sqm coat curing and cost of all material, labour, T&P etc. required for proper completion of work.for two coat.(new item chapter No. 8 ,SI. No. 31) |
| 15 | Earth work in filling in ordinary soil excavation to be in the form regular pits note excluding 0.5M in depth and earth work embankment to be in 20 Cm layers including ramming and dressing the surface to required slows and also including 1.5M, lift and 30 M lead in all complete. site up to 10 km distance.(As per Analysis of Rate) |
| 16 | Mild steel or iron work of small size and sections such as holding down bolts, hold fast, tie rods, grating etc, (when not included in an overall rates) wrought to required shape as necessary for bending etc including supply of steel and its wastage including cost of bolts, nuts if required, welding, grinding and making holes as required for completion of work. (DSR 2023-24, 10.01) |
| 17 | Supply & Laying precast concrete blocks (ordinary Interlocking Tiles) for paving of thickness Grey 80mm (Compresive strength not less then 30 mpa) Including 25 mm theick local sand Base leveling and dressing of surface to requred level and slope] filling Jointsa With local sand all complete work as speciefied in IS 15658:2006. (PWD SOR 2025-26 Chapter No-12 SI No. 10 New Item) |
| 18 | Supply & Laying precast concrete blocks (ordinary coloured Interlocking Tiles) for paving of thickness Grey 80mm (Compresive strength not less then 30 mpa) Including 25 mm thick local sand Base leveling and dressing of surface to requred level and slope] filling Jointsa With local sand all complete work as speciefied in IS 15658:2006. (PWD SOR 2025-26 Chapter No-12 SI No. 10 New Item) |
| 19 | providing and laying cement concrete in 1:2:4 (1 cement: 2 coarse sand :4 graded stone aggregate 40mm norminal size) including supply of all materials, labour and T&P etc. |
| 20 | M.S or Iron work in plain work such as reinforced concrete or reinforced brick work (When not included in and an over all rates) brought to required shape as necessary of the work and including the suply of steel and its wastage bend, hooks and authorized over lapping shall be measured upto floor to level. (As per Analysis of Rate) |
| 21 | Painting 1st coat over priming coat ( but excluding cost of priming coat) on steel and other metal surface upto 10cm width or girthor small articles not exceeding 0.10 Sq.M. in area with superior synthetic enamel such as Luxol 3, Higloss Apcolite. superlac, dulux specified brushing to give and even shade and including the cleaning the surface of all dirt, dust and other foreign matter sand papering and scrapping including cost of all materials, labour, tools and plants etc. required for proper completion of work. (SOR 2025-26 Chapter No.08 SI No. 4) |
| 22 | Providing and laying Ceramic glazed tiles on walls of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.DSR 2023-24 S.No. 11.37 A |
| 23 | White Vitreous China Flat back wash basin size 450x 300 mm with single 15 mm C.P. brass pillar tap(DSR 2022-23, 17.7.7) |
| 24 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.(DSR 2022-23 , 17.23) |
| 25 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:(DSR 2022-23 17.1.1) |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25mm nominal dia pipe(DSR 2022-23, 18.7.3) |
| 27 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(DSR 2022-23, 18.48) |
| 28 | Supplying and planting tree well developed in polybag of size 20cm as per direction of the officer-in-charge ............................. Including all Complete |
| 29 | Supplying MS Tree guard in (1200X450mm) size ............................. Including all Complete.(as per analysis of rate) |
| 30 | M.S Speciefication Board including painting & writing |
| 31 | P/F of Inogration Granite stone including writing and Please Enable Macros to View BoQ information |