Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #56138507

Tender For Comprehensive Day To Day Repair And Maintenance Of Internal Electrification Services For Md Accn Incl Map Bldg At Vsn Gandhinagar Under Ge (Af) Chiloda

Issued by Statutory Bodies & Commissions/Committees · Gandhinagar, Gujarat
Tender Value
48.50 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
5 days left
EMD
97000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gandhinagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Comprehensive Day To Day Repair And Maintenance Of Internal Electrification Services For Md Accn Incl Map Bldg At Vsn Gandhinagar Under Ge (Af) Chiloda

BOQ

Name of Work:- COMPREHENSIVE DAY TO DAY REPAIR AND MAINT OF INTERNAL ELECTRIFICATION SERVICES FOR MD ACCN INCL MAP BLDG AT VSN GANDHINAGAR UNDER GE (AF) CHILODA
Sl. No. Item Description
1M & L for providing Point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVC concealed conduit of adequate size but not less than 20mm in dia and 1.2mm thick with all fittings and accessories including modular surface box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan point controlled by one one way modular switches including one run 1.5 sqmm (nominal area) PVC insulated FRLSH unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly including taking down old unsv complete all as specified & directed. Note :- (i) Contractor will depute dedicated electrician and helper alongwith supervisor to note down the complaint from complaint register. Daily complaint shlip shall must be sigend by JE E/M. Seperate Register shall be maint for issuing / using of E/M materials against this contracts shall also be signed by contractor (not by his rep) and JE E/M and countersigned by Engr-in-Charge. The materials used shall be paid sepeately against respective item in this work. This register and complaint slip shall be fwd alongwith RAR/Final Bill for verification.
2One light/Fan point controlled by one one/way switch complete all as specified and directed.
3One light point controlled by two 2 way switches complete all as specified and directed.
4One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size complete all as specified and directed.
5One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed.
6One 3 pin 5 Amps socket outlet on independent board with cable of 2.5 sqmm size complete all as specified and directed.
7All as per item No 1 here in before but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.
8M&L for sub main wiring using four single core 10 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLSH) ISI marked drawing in and including 25mm dia rigid non metalic PVC concealed conduit & accessories like bends, tee, etc fixed and ceiling and connecting to earth dolly and including two single core 10 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed. NOTE: 4 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length. Rate quoted by contractor is demed to be included to match the disturbed surfaces with exisitng wall and no extra payment shall be made on this account
9M&L for sub main wiring using four single core 6 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLSH) ISI marked drawing in and including 25mm dia rigid non metalic PVC concealed conduit & accessories like bends, tee, etc fixed and ceiling and connecting to earth dolly and including two single core 6 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length. Rate quoted by contractor is demed to be included to match the disturbed surfaces with exisitng wall and no extra payment shall be made on this account.
10M&L for sub main wiring using two single core 4 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLSH) ISI marked drawing in and including 25mm dia rigid non metalic PVC Concealed conduit & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including one single core 4 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length. Rate quoted by contractor is demed to be included to match the disturbed surfaces with exisitng wall and no extra payment shall be made on this account.
11M&L for sub main wiring using two single core 2.5 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLSH) ISI marked drawing in and including 20 mm dia rigid non metalic PVC Concealed conduit & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including one single core 2.5 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length. Rate quoted by contractor is demed to be included to match the disturbed surfaces with exisitng wall and no extra payment shall be made on this account.
12Supply and fixing in replacement LED Tubelight lights fitting 1x 18W/20W (White/warm white/multi colour Colour and quantity as decided and directed by Engineer in Charge), 220V,AC with driver, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Bajaj/Havells/Philips or equivalent as approved by GE.
13Supply and fixing in replacement LED Tubelight lights fitting 1x 36W/40W (White/warm white/Multicolour and quantity as decided and directed by Engineer in Charge), 220V,AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Bajaj/Havells/Philips or equivalent as approved by GE.
14Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Bajaj/Havells/Philips or equivalent as approved by GE.
15Supply and fixin replacement 10W LED Bulkhead light, pressure die cast housing LED bulkhead with IP65 Protection suitable for surface/wall mounted,complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make : Bajaj/Havells/Philips or equivalent as approved by GE.
16Supply and fix in replacement Recessed mounted square slim & elegant downlight panel of 18W LED light white/warm white/multi coloured (quantity as directed and decided by Engineer in Charge) made of aluminium PDC housing for indoor application with high aesthetic appeal for uniform light. suitable for recessed/ceiling of size 300 mm x 300mm ,complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make : Bajaj/Havells/Philips or equivalent as approved by GE.
17Supply and fixing in replacement LED luminaire 600 mm x 600 mm,36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light white/warm white/multi coloured (quantity as directed and decided by Engineer in Charge) complete with driver, holders & LED lamp suitable for false ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make : Bajaj/Havells/Philips or equivalent as approved by GE.
18Supply and fixing in replacement round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free white/warm white/multi coloured (quantity as directed and decided by Engineer in Charge) ight complete with drivers, holders ,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and directed. Make : Bajaj/Havells/Philips or equivalent as approved by GE.(Note :- size of light fittings shall be approved and directed by Engr-in-charge)
19Supply and fixing in replacement round shape 12 watt 220 volts AC recessed mounted LED downlighter with COB technology type with high efficiency PMMA diffuser soft glare free white/warm white/multi coloured (quantity as directed and decided by Engineer in Charge) light complete with drivers, holders ,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Bajaj/Havells/Philips or equivalent as approved by GE.(Note :- size of light fittings shall be approved and directed by Engr-in-charge)
20Supply and fixing in replacement round shape 20 watt 220 volts AC recessed mounted tiltable and swivel adjustable upto 36 degree LED downlighter with COB technology type with high efficiency PMMA diffuser soft glare free white/warm white/multi coloured (quantity as directed and decided by Engineer in Charge) light complete with drivers, holders ,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make : Bajaj/Havells/Philips or equivalent as approved by GE.(Note :- size of light fittings shall be approved and directed by Engr-in-charge)
21Supply and fixing in replacement of decorative LED AC profile light 60 LED/Mtr, CCT - 3000K, IP-65, 15 mtr length (White/Warm white/multi coloured as decided and directed by Engineer in Charge)water proof with jointer and adaptor suitable for 180 V to 280 Volt complete all as specified and directed.Make : Bajaj/Havells/Philips/Wipro or equivalent as approved by GE.
22Supply and fixing in replacement of decorative LED AC tricolour rope light having 560 lumen watt output per meter and 120 LEDs per meter, IP-65, 30 mtr length (White/Warm white/multi coloured as decided and directed by Engineer in Charge)water proof with jointer and adaptor (Quantity as directed by Engineer in charge) suitable for 180 V to 280 Volt complete all as specified and directed.Make : Bajaj/Havells/Philips/Wipro or equivalent as approved by GE.
23Supply and fixing in replacement of PVC insulated and round sheathed flexible muti stranded copper conductor of size 4 Sqmm 3 core, 1100 volts complete all as specified and directed.
24S&F in replacement Call bell, Ding Dong AC. 230 volts,single pole complete all as specified and directed.
25S/F in replacement Modular switch one way 5/6 Amp ,1 module,240 Volts complete all as specified and directed.Make : Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
26S/F in replacement Modular switch two way 5/6 Amp,1 module, 240 Volts complete all as specified and directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
27S/F in replacement Modular Bell push 6 Amp,1 module, 240 Volts complete all as specified and directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
28S/F in replacement Modular socket 2/3 pin, 6 Amps,2 module 240 Volts complete all as specified and directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
29S/F in replacement Modular switch one way, 16 Amp,1 module, 240 Volts complete all as specified and directed.Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
30S/F in replacement Modular socket 16A, 6 pin, 3 module 240 volts complete all as specified and directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
31S/F in replacement ceiling rose surface bakelite two to three terminal 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed.Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
32Supply and fixing in replacement fan step regulator,120W, 2 Module A/C 240 Volts complete all as specified and directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
33Supply and fixing in replacement fan rotary regulator,120W,2 Module A/C 240 Volts. complete all as specified and directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
34S&F in replacement Factory made board distribution in sheet steel enclosure VTPN loadline DB 4 WAY double door glazed with 200 Amps rated bus bar,, 415 Volts suitable for housing MCCBs as incomer and MCB as outgoing. Complete including sinking of DB on wall and making surface good.complete all as specified and as directed. Make:- Legrand/Havells/L&T or equivalent as approved by GE.(Note :- MCCBs to be measured and paid seperately).
35S&Fin replacement Factory made board distribution in sheet steel enclosure vertical double door with 200 Amps rated bus bar, TPN, 4 ways, 240 Volts suitable for housing MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
36S&F in replacement Factory made board distribution in sheet steel enclosure double door glazed with 200 Amps rated bus bar, SPN, 8 ways, 240 Volts suitable for housing MCBs.complete all as specified and as directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
37S&F in replacement MCCB 125 Amps, 415 volts, 4 pole , 16 KA complete all as specified and as directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
38S&F in replacement MCB, TPN, 415 volts, C Curve , 100 Amps, 10 KA,4P complete all as specified and as directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
39S&F in replacement MCB, TPN, 415 volts, C Curve , 63 Amps, 10 KA,4P complete all as specified and as directed.Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
40S&F in replacement MCB, SPN, 240 volts, C Curve , 63 Amps 10 KA complete all as specified and as directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
41S&F in replacement MCB, SPN, 240 volts, C Curve , 32 Amps 10 KA complete all as specified and as directed. Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
42S&F in replacement MCB, SP, 240 volts, 20-32 Amps 10 KA ,C Curve, complete all as specified and as directed.Make:- Legrand/Havells/Anchor/L&T or equivalent as approved by GE.
43M&L for taking down & re-winding of ceiling fan motor 1200 mm sweep of any type including removing old burnt wire copper wire as per existing gauge & insulated paper, varnishing also including replacement of bearing, bush and capacitor with cleaning/greasing & testing complete all as specified and directed by Eng-in-charge.
44M&L for taking down & re-winding of Exhaust fan motor 300 mm sweep of any type and size including removing old burnt wire copper wire as per existing gauge & insulated paper, varnishing also including replacement of bearing ,bush and capacitor with cleaning/greasing & testing complete all as specified and directed by Eng-in-charge.
45M&L for taking down & re-winding of Wall fan motor 400 mm sweep of any type including removing old burnt wire copper wire as per existing gauge & insulated paper, varnishing also including replacement of bearing ,bush and capacitor with cleaning/greasing & testing complete all as specified and directed by Eng-in-charge.
46S&F in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) complete all as specified and directed by Eng-In-Charge.Make:- Bajaj/Havells/Usha or equivalent as approved by GE.
47S & F in replacement exhaust fan 300 mm sweep heavy duty type in metal Body as required at site complete all as specified and directed by Eng-In-Charge. Make:- Bajaj/Havells/Usha or equivalent as approved by GE.
48Supply & fix in repair capacitor for fan 1/1.5/2.5/3.15 MFD complete all as specified and directed by Eng-In-Charge.
49Supply and fix in repair ceiling fan blade any sweep as existing complete all as specified and directed by Eng-In-Charge.
50Supply and fix in repair wall/exhaust fan blade any sweep as existing complete all as specified and directed by Eng-In-Charge.
51M&L for painting one coat of ceiling fan /Exhaust fan complete as per existng colour with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning of dust etc of any sweep writing of MES No on ceiling/exhaust fan any sweep after painting with suitable size of stansile and super enamelled black paint complete all as specified and directed by Eng-In-Charge.
52Supply and fix in repair exhaust fan 200/250 mm sweep silent type in PVC Body as required at site complete all as specified and directed by Eng-In-Charge. Make:- Bajaj/Havells/Usha or equivalent as approved by GE.
53Supply and fix in repair exhaust fan 300 mm sweep silent type in PVC Body as required at site complete all as specified and directed by Eng-In-Charge. Make:- Bajaj/Havells/Usha or equivalent as approved by GE.
54Supply and fix in repair Thermostat of water heater for 25/50 Ltrs capacity AC 230V complete all as specified and directed by Eng-In-Charge.
55Supply and fix in repair Water heater heating element for 25 Ltrs capacity 1.5/2 KW complete all as specified and directed by Eng-In-Charge.
56S & F in replacement flexible hot water pipe steel cover wire of length upto 1 metre with washer for hot and cold water for geyser connection complete all as specified and directed by Eng-In-Charge.
57S & F in replacement flexible cold water pipe of length upto 1 metre with washer for hot and cold water for geyser connection complete all as specified and directed by Eng-In-Charge.
58Supply and fix in repair 1.00 Sqmm two core PVC insulated, unsheathed multistranded copper twin twisted flexible wire 1100 volts grade complete all as specified and directed by Engr in Charge.
59Supply and fix in repair 1.5 Sqmm 3 core PVC insulated, unsheathed multistranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge.
60Supply and fix in repair 2.5 Sqmm 3 core PVC insulated, unsheathed multistranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge.
61Supply and fix in repair Geyser Assembly 6 hole/9 hole of water heater for 25/50 Ltrs capacity AC 230V complete all as specified and directed by Eng-In-Charge.
62Supply and fix in repair Outer Body with top and bottom cover of water heater for 25/50 Ltrs capacity AC 230V complete all as specified and directed by Eng-In-Charge.
63Supply and fix in repair Inner copper tank for geyser cap 25 ltr of guage - 22 complete all as specified and directed by Eng-In-Charge.
64Supply and fix in repair acoustic insulation wool of water heater for 25/50 Ltrs capacity AC 230V complete all as specified and directed by Eng-In-Charge.
65S&F in repair 1 phase temper proof Electric Energy meter with LCD display 240 volts 2 wire system, 10-40 amps, 50 HZ having accuracy class 1.00 as per IS-13779 complete with all standard anti temper features including logging & display of tamper data complete including seling properly using lead seals and wires as required complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information
66S&F in repair 1 phase temper proof Electric Energy meter with LCD display 240 volts 2 wire system, 10-40 amps, 50 HZ having accuracy class 1.00 as per IS-13779 complete with all standard anti temper features including logging & display of tamper data complete including seling properly using lead seals and wires as required complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56138507
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.50 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive Day To Day Repair And Maintenance Of Internal Electrification Services For Md Accn Incl Map Bldg At Vsn Gandhinagar Under Ge (Af) Chiloda
Basic Detail
Tender No 8445/26-27/E8
Bidding Type Tender
Location
City Gandhinagar
State Gujarat
Key Dates
Publish Date 23 Jun 2026
Submission Date 14 Jul 2026
Open Date 16 Jul 2026
Finance
Tender Value 48.50 Lakhs
Tender Fee 500
EMD 97000
Exemption Available
Document List
BOQ_867119.xls
db5cb831-43cf-45f8-bf65-a8d0cbd83f31.html
Tenderdocument8445.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_867119.xls

html

db5cb831-43cf-45f8-bf65-a8d0cbd83f31.html

pdf

Tenderdocument8445.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer