Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #56138492

Tender For special Repair To Bldg No P-175, 176 (Guard Room) And Main Gate Of Harbaksh Dwaar And Other Sanctioned Works Under Age B/R-Ii Of Ge (E) Jrc (Tender Id No 2026_Mes_764289_2)

Issued by Statutory Bodies & Commissions/Committees · Jalandhar, Punjab
Tender Value
47.43 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
1 days left
EMD
94860
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Bldg No P-175, 176 (Guard Room) And Main Gate Of Harbaksh Dwaar And Other Sanctioned Works Under Age B/R-Ii Of Ge (E) Jrc (Tender Id No 2026_Mes_764289_2)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Jul-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-Jul-2026

BOQ

Name of Work:- Spl repair to Bldg No P-175, 176 (Guard Room) and main gate of Harbaksh Dwaar and other sanctioned works under AGE B/R-II of GE (E) JRC (Tender ID No 2026_MES_764289_2)
Sl. No. Item Description
1Demolition of cement concrete of any description and in any position and removing surplus spoil out of defence land where directed at a level not exc 1.5 m above the starting point all as specified and as directed.
2M&L for 50mm PCC 1:3:6 type C2 using 40mm graded aggregate as in plinth protection and path finishing the surfaces even and smooth without using extra cement all as specified
3M&L for 75mm PCC 1:3:6 type C2 using 40mm graded aggregate as in plinth protection and path finishing the surfaces even and smooth without using extra cement all as specified
4Demolition floor, hearth or wall tiling/stone (upto appx 8 Mtr height) including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified
5M&L for non skid joint free glazed ceramic coloured tiles of area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm and 6-7 mm thick in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed..
6M&L for Dholpur stone as on wall cladding with machine cut face work, pillar, arches, hexagonal roof pillar and all facing etc of 15 mm to 18 mm thick one side single length laid and jointed in cement and sand mortar 1:2 including ardelite chemical with epoxy and recess pointed with an admixture of white cement and fixed with screw and dholpur stone dust 1:1 and making edges, work in small patches, stone shall be of uniform colour of each stone and size not exc. 0.20 sqm each fixed, over and including 15mm thick cement plaster in CM (1:4) on brick or concrete wall surfaces finished rough surfaces to receive tiles all as specified and as directed.
7M&L for mild steel work in flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. by Engineer-in-charge
8M&L for non-skid coloured ceramic glazed tile 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed..
9M&L for 25mm thick cement concrete (1:2:4) type B-1 (12.5 mm graded aggregate) to receive the top layer of tiles complete all as specified and as directed.
10Ditto all as per Srl item No 9 above, but on skirting etc over and including 10 mm thick cement plaster finished even and rough to receive tiles in Cement mortar (1:4) complete all as specified
11Roughening surface of old concrete floor or wall by picking, sweeping clean and washing down with water to remove dust including brushing neat cement slurry with 3.00 Kg/Sqm of Cement etc. complete all as specified
12M&L for coloured glazed tiles of size 450x350x7mm thick as in vertical surface i.e. skirting/dado set and jointing in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10mm thick in cement mortar 1:4 finished rough to fix tiles, complete all as specified and as directed.
13Demolition and dismantling of reinforced cement concrete of any description and in position not otherwise specifically provided for complete all as specified
14M&L for MS TMT bars 10mm dia and over dia and cut to length, bent to shape required incl cranking bending spirally for hooping for column hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
15Ditto all as per Srl item No 14 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete al as specified & directed
16M&L for RCC (1:2:4) type B-1 using 20mm graded aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
17M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
18M&L for 16-18mm thick pre-polished green marble as in cooking platform over 15mm thick screed bed in CM (1:6) including grinding and mirror polished/granite polished and making hole for LPG pipe and rounding of edge of stone, complete all as specified and as directed.
19S&F 16 to 18mm thick granite (of any type) tiles machine cut, in skirting/dado laid over cement screed 15 mm thick in CM 1:6 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified
20M&L for rendering 15mm thick cement plaster in cement mortar (1:6) on unfair faces of brick/concrete surface finished even and smooth without using extra cement complete all as specified and as directed.
21Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc and removing surplus spoil out of Defence Land where directed at a level not exc 1.5 m above the starting point all as specified
22M&L for 15 mm thick cement plaster in cement mortar 1:6 on internal surface of brick or concrete surface finished even and smooth without using extra cement all as specified
23M&L for preparing new surfaces plastered or unplastered surfaces of walls by applying two coats of oil bound distemper over a coat of primer over a coat of 1 mm avg thickness wall putty complete all as specified.
24M&L for complete removal of existing treatment and preparation of old plastered surfaces of walls and applying two coat of distemper oil emulsion over a coat of primer over 1mm avg thickness wall putty complete all as specified
25M&L for 15mm thick cement plaster on brick or concrete surfaces in cement mortar (1:4) mixed with integral water proofing compound in the proportion recommended by manufacturer, surfaces finished fair and even complete all as specified and as directed.. (WPC shall be measured and paid separately under appropriate item of this BOQ).
26M&L for new plastered surface of walls surface including scraping down smoke soot, moulds , moss & efflorescent salts of acrylic exterior emulsion paint (weather coat) two coats over a coat of wall primer complete all as manufacturer’s instructions complete all as specified and as directed.
27Supply only integral water proofing compound all as specified
28M&L for complete removal of existing treatment of old decorated Wall surface including scraping down smoke soot, moulds, moss & efflorescent salts of acrylic exterior emulsion paint (weather coat) two coat over a coat of wall primer complete all as manufacturer’s instructions complete all as specified and as directed.
29M&L for 5mm thick cement plaster in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement all as specified
30M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of ceiling surfaces complete all as specified and as directed. by Engr -in-charge.
31M&L for three coat of white wash on newly plastered surface of wall including preparation of wall surface complete all as specified and as directed.
32M&L for preparation of old decorated plastered or unplastered surfaces and apply two coats of white wash to matching with new wall surface including cornices etc all as specified and as directed.
33Dismantling of concrete by chiselling from RCC members like col, beam parapet, facia, chajja, ceiling etc exposing the reinforcement without disturbing the reinforcement and primed with using Araldite epoxy resins manufactured by M/s ciba Geigy Ltd/ FAIR BOND EP/Sika or other approved manufacture and providing doubling coat of 20mm thick in CM 1:3 including necessary form work and reinforced with chicken wire mesh where reqd and rendering 15mm thick in cement mortar 1:3 at any height, complete all as specified and as directed.
34S&F in repairs Vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern) incl seat cover and flushing pipe for pedestal pipe etc. complete all as specified
35S&F chromium plated brass JET including PVC pipe connection fixed to EWC all as specified and as directed..
36S&F CP grating 125mm dia all as specified and as directed. by Engr-in-Charge
37S&F Brass chromium plated tubular towel ring (Square/Rectangular type) complete all as specified and as directed.
38S&F in repair, toilet paper holder, fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed..
39S&F in repair, CP soap dish holder and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed.
40M&L for Galvanised iron water tubing 15 mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc including taking down the existing tubing complete all as specified
41M&L for Galvanised iron water tubing 20 mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc including taking down the existing tubing complete all as specified
42S&F PVC valveless, syphonic action type flushing cistern low level white with inlet ball valve float and handle, 10 ltr capacity including brakets fixed in repairs complete all as specified
43S&F Vitreous china wash hand basin , white, flat back 550x400mm including one number brass CP waste coupling ,32mm dia , PVC waste pipe with connector , brackets 2 nos including cutting for and pinning in ends of brackets complete all as specified
44S&F in repair single lever basin mixer with popup waste, suitable for fixing to 15mm bore (dia) GI pipe, complete all as specified and as directed..
45S&F 15 mm Angle/stop valves, cast copper alloy, screwed down, high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and as directed.
46S&F 15mm stop valves, (Concealed type) fancy type chromium plated with long shank and cup screwed down, high pressure with crutch or butter fly handle screwed at two right angles ends for both iron pipe or for unions and fixed in repairs complete all as specified and as directed.
47S&F for flexible PVC Waste pipe of approved quality 32 bore, 75 cm long with one end socketed fixed to waste coupling, compete all as specified and as directed.
48S&F PVC connection, reinforced 45cm long 15mm in size with brass check nut and PVC washers at both ends complete all as specified and as directed.
49S&F Bib tap long body, cast copper alloy , chromium plated suitable for 15mm bore iron pipe with long body fancy type complete fixed in repairs all as specified and as directed.
50S&F brass chromium plated shower rose of 125mm size, with or without swivel joints including fixing to steel pipe or union in repairs complete all as specified and as directed.
51S&F brass chromium plated tubular towel rail 20 mm dia , D type 60 cm long between CP flanges all as specified
52M&L for chromium plated peg set of 5(PTMT), fixed with screws and plugging to rear side of door shutter in bath, complete all as specified and as directed..
53S&F mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate welded to steel frame/ screwed to wooden frame complete all as specified and as directed..
54S&F for glass shelf (with brass brackets) and fixed to wooden plug with chromium plated brass screw and cup washers, sample approved by Engr -in-charge all as specified and as directed.
55S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
56M&L in repair mild steel pipe 25 mm dia curtain rod with PVC coating fixed in the MS hooks, and finials/side brackets (both side), shade as approved by GE all as specified
57Taking down chowkats or frame not exc. 1.5 sqm each with shutters (without taking off shutters from the fames) complete all as specified
58Taking down chowkats or frame exc. 1.5 sq m but n.exc 4 sqm each with shutters (without taking off shutters from the fames) complete all as specified
59Taking down shutters of any description exc. 1 Sqm and n.exc. 2 sqm complete all as specified and as directed.
60M&L for MS work as in hold fast and similar small articles complete all as specified.
61M&L for framed work as in doors or gates of angle or other section with gusset plates, hold fast rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as specified and as directed..
62S&F for 35 mm thickness of factory made flush shutter solid core construction with particle board & ply wood face panels, one face with decorative face veneer with lipping/frame to match, commercial type on both side including 40 x 6 thick 2nd class Hard wood lipping on edge, complete all as specified and as directed..
63S&F for 2nd class hard wood 35 mm thick glazed and skeleton shutters, factory made, open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I, sector 8, clause 8.20 (a) complete all as specified and as directed.
64S&F butt hinges medium weight, cold rolled mild steel 100 mm size complete all as specified and as directed.
65S&F 300 mm long mild steel sliding door bolts stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified.
66S&F 250mm long aluminium alloy anodised sliding door bolts with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified.
67S&F Mild steel pressed handles oval type stove enamelled black 150 mm size complete all as specified and as directed.
68S&F Mild steel barrel tower bolts, 200mm long, stove enamelled black, with bright bolt complete all as specified and as directed.
69S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor overall length of cover plate 75mm complete all as specified and as directed..
70M&L 75mm PVC (SWR) PVC (SWR) floor trap, plain with grating including jointing with solvent cement fixed in repairs complete all as specified and as directed..
71M&L 75mm PVC (SWR) PVC (SWR) gully trap, 125 mm, setting and jointing with solvent cement complete all as specified and as directed..
72S&F PVC solid door frame of size 50mm x 47mm made out of 5 mm wood grain and edges painted PVC Sheet & edges will be painted to match with printed sheet and to be matched with shutter, reinforced with MS square tube, as per specification and drawing in SSR Part-II
73S&F factory made solid panel PVC Door 30mm thick (style) consisting of frame made out of M.S. Tubes for top & bottom rails M.S. frame shall be covered with heat moulded wood grain PVC sheet and edges painted, PVC `C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and wood grain PVC sheet and edges painted 10mm thick PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of wood grain PVC sheet and edges painted 10 mm thick PVC sheet to be fitted in MS frame welded/sealed to the 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (90 degree) used instead of exposed portion of PVC sheet beading, and joined together with solvent cement, fixing in the frame at the site as per specification & drawing
74S&F aluminium butt hinges, 75 mm size for fixing PVC Door Shutter complete all as specified
75S&F for Aluminium handles 125 mm size fixed with screws all as specified
76S&F for Aluminium tower bolts, 150mm long fixed with screw all as specified and as directed.
77S&F aluminium anodised tower bolts 200 mm size fixed with machine screws complete all as specified and as directed..
78S&F Hasp & Staple aluminium 100 mm , including bolt to hinge plate and fixed with screws with Cup Board shutter, all as specified
79Dismantling of brick tiles single layer as in roof covering complete all as specified
80Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof) removing surplus spoil out of Defence Land where directed at a level not exc 1.5m above the starting point all as specified
81M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in benching, roof padding, roof kerbs or mud stops, coping etc rounded or chamfered on edges complete all as specified
82M&L for 12 mm thick cement plaster in cement mortar 1:4 with water proofing compound as per manufacturer's instructions to brick or concrete surface finished even and smooth without using extra cement and using waterproofing compound all as specified (WPC shall be measured and paid separately)
83Cleaning the surface and made free of dirt, existing treatment, foreign particle, laitance followed by grinding all all protrusion to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expiation contraction. Cutting the grooves with suitable cutter machine in V groove filled with repairs mortar/ microconcrate / general purpose grout as recommended proportionally as per recommendation of manufacture. Making of Gollas at all the corners with polymer modified mortar (1:4) cement sand with 3.5% acylic of cement weight complete all as specified. Make: STP/Asian Paints/Sikka
84Supply and applying high build elastomeric waterproofing coating based on pure hydrophobic polyurethane cold applied of spray/brush applied, membrane with an elongation of 280% and tensile strength of 2.7N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88% solid content. The system includes final base preparation, epoxy primer 1:1 (Resin; harder) application with 100% water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 kg per Sqm. Application should be done with Graco sprayer by a company authorised applicator ” of given compound all as specified. Make: STP/Asian Paints/Sikka
85Demolition of brick work as in walls/parapet walls removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces, complete all as specified and as directed.
86M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 compound all as specified
87Ditto all as per Srl Item No 86 above, but except bricks
88S&F 1000 ltr rotational moulded polythylene water storage tank (Cylindrical vertical with closed top) hosted, ISI marked and fixed in position incl dismantling of existing tank of any description complete all as specified
89S&F 20mm dia Brass Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight-210gms.) complete all as specified
90S&F for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed..
91M&L for preparation of new wood or wood based surfaces of any description, not otherwise described over 10cm width or girth and applied two coat of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. by Engr -in-charge.
92M&L for preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applied two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and as directed. by Engr -in-charge
93Surface excavation n.exc 30cm deep and averaging 15cm deep in soft/loose soil all as specified and as directed.
94M&L for broken stone or boulder hard core of gauge n.exc, 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and as directed.
95M&L for 100 mm thick cement concrete 1:3:6 type C-2 (using 20mm grade aggregate) as in sub base of flooring all as specified and as directed.
96M&L for 25 mm sand cushion, filling under floors or in foundations including watering and consolidation all as specified and as directed..
97M&L for laying 60 mm thick machine pressed precast concrete interlocking paver block and shape and size conforming to IS -15658-2006 of M-35 Grade with grey cement and pigment complete all as specified and as directed.. NOTE: The sample shall be got approved from the GE before build procurement and lots shall be got tested indecently by the GE
98M&L for chequered cement concrete tiles 30cm x 30cm x 18 to 20 mm thick set with grey cement and pigments jointed and pointed in neat coloured cement slurry in floors over and including 15 mm thick cement screed bed in cement mortar (1:6) including demolition of old tiles/concrete floor all as specified and as directed.
99M&L for PCC (1;2:4) type B-1 using 20mm graded stone aggregate as in sides of rounded or chamfered on edges of interlocking tiles complete all as specified and as directed.
100Demolition and breaking up drain pipes any dia of bore (SGSW, AC or reinforced concrete) pipe set in cement mortar complete all as specified
101Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, for any type of soil as directed by Engineer-in-charge
102Ditto all as per Srl Item No. 101 here in before, but depth exc 1.5 m upto 3.00 mtr
103M&L for reinforced concrete pipes, class NP3, laid and jointed complete with collars 200 mm bore laid in trenches and jointed complete all as specified.
104M&L for cement concrete 1:4:8 type D2 (using 40 mm grade aggregate) as in concrete bed to drain pipes 200mm internal dia incl paking under and haunching against the pipe sides of pipe after they are and tested all as specified
105M&L for precast cement concrete type B-1 1:2:4 (20mm graded aggregate) and set in Cement Mortar (1:4) as in landings, manholes cover slabs, chajjas, shelves and similar articles including necessary form work all as specified and as directed..
106M&L for MS TMT bars 10 mm and over dia and cut to length, bent to shape required incl cranking bending spirally for hooping for clos hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia all as specified and as directed.
107M&L for cutting into existing manholes for connecting new drains or sewage line, making good to pipe and rendering ,cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required internal dia of pipe in 150mm all as specified and as directed.
108M&L for mild steel work as small articles for handles, holdfasts, steps, rungs, etc knee piece and similar small article complete all as specified
109S&F steel windows/ventilators 1.25 mm thick Box type (primer coated) ERW hollow 'P' section of size 60 mm x 25 mm single rebated double window (comprises of glazed shutter and gauged shutter) EWR sec 50 mm x 20 mm and 1 mm thick and four openable leaf consisting four Nos sash bar of 'T' section 20 mm x 3 mm complete welded to frame with two vertical mullion of EWR bot 'T' section of size 60 mm x 25 mm and 1.25 mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1, four Nos for each window including following fittings welded to failed shutter:- (a) Holdfasts 150 mm long 12mm x 3 mm made to shape- 4 Nos per window (b) Handle of Z sec 20 mm x 25 mm, 100 mm long - 1 nos per leaf. (c) MS tower bolt 150 mm long - 2 Nos per leaf. (d) 'Z' sec 20 mm x 25 mm , 100 long stopper-01 Nos per leaf, (e) Cleat 55mm long of hollow square 15 mm x 20 mm x 63 mm welded to hinges - 1 Nos per leaf (f) MS pintal hinges of size 75 mm x 12 mm - 2 Nos per leaf. (g) fabrication and fixing arrangement complete. Note:- Guard bar/ glass pane and wire gauge shall be measured and Paid separately
110Ditto all as per Srl item No. 109 above, but in gauged shutters without sash bars all as specified and as directed.
111S&F framed work such as grills, gratings, etc .with ends of bars shouldered and/ or riveted , or forget into spikes ; framed guard bars parallel iron doors and similar work conforming to Fe.290.Gde-E-165 complete all as specified
112S&F galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks complete all as specified
113M&L for 3.00 mm thick glass sheet, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified
114S&F in repair squatting pan WC orissa pattern size 580 x 440 mm white with integral floor rest with P or S trap incl provn of lime concrete bedding incl breaking up existing damaged WC seat and connecting flush pipe etc and make good to floor complete all as specified
115S&F for stainless steel hand rails with or without chain, half round or other steel section or core for wooden/steel section hand rail straight/curved portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps, partion including embedding in concrete and screwing etc wind ties for roof including securing bolts etc complete all as specified and as directed. by Engr-in-Charge
116S&F for 3mm thick fibre sheet any colour fixed with screw/nut etc complete all as specified directed by Engr-in-charge
117S&F for Providing precast cement concrete louvres and jallies, 25mm thick (measured solid), PCC 1:2:4, Type B0 (12.5mm graded aggregate) including all mouldings with frame Set in CM 1:4 including dismantling/ demolition of existing louvers/jallies complete all as specified and as directed.
118Demolition of cement concrete in ground floors and paving n. exc 15 cm thickness (below or above the ground level) complete all as specified and as directed. .
119M&L for 75mm thick cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in sub floors, sub base, hardstanding, concrete surfaces finished fair & even to receive topping floor finish/layer complete all as specified & directed
120M&L for 100mm thick plain cement concrete 1:4:8 Type D2 (using 40mm graded aggregate) as in sub base of flooring complete all as specified and as directed.
121M&L for 40mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in sub floors, sub base, concrete surfaces finished fair & even to receive topping floor finish/layer complete all as specified & directed.
122Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified
123S&F fibre sheet to angle or fillets with screws/nuts/bolts to wall cladding/roof complete all as specified and as directed..
124Excavation in post holes (or similar holes) in soft/loose soil, each not exceeding 0.50 cum and getting out, returning, filling in and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, including watering and removing surplus soil to a distance not exceeding 50m away from the starting point and making good surfaces complete all as specified and as directed.
125M&L for PCC (1:2:4) type B-2, (using 40mm graded stone aggregate) as in foundation, mass fillings for posts/struts etc. complete all as directed
126M&L for Rolled sections as in vertical member, rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W(GdeE-250) quality A, complete all as specified and as directed. by Engr-in-Charge.
127M&L for mild steel plate plain, square/rectangular cut welding to base of hollow pipes etc complete all as specified
128M&L for compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, inlcudings all lattice bars complete all as specified and as directed. by Engr-in-charge.
129M&L for 20mm dia rag bolts 450mm length with nut & washer one side of J Hook type complete all as specified and as directed..
130S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering cladding to wall, fixed with self drilling screws complete all as specified
131S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering cladding to wall, fixed with self drilling screws complete all as specified
132M&L for earth filling in floors etc., spreading and leveling in layers not exceeding 25cm thick, well ramming including watering as required complete all as specified and as directed..
133M&L for plain cement concrete (1:4:8) Type D-2 using 40mm graded aggregate in foundations filling and mass concrete complete all as specified and as directed..
134M&L for Reinforced Cement Concrete M-25 (Design mix) using 20 mm graded stone aggregate as in slab supported on wall beam, column in floors, roof landings balconies deck slabs and in shelves and like complete all as specified .
135M&L for Reinforced Cement Concrete M-25 (Design mix) using 20 mm graded stone aggregate as roof beam beam, GB, Lintel beam complete all as specified
136M&L for Use and waste of formwork to soffits of suspended slabs such as roof slab , floor slabs, landing and similar works not exceeding 200mm thick (Horizontal .sloping ) for flat & rough finished surface of concrete complete al as specified and as directed..
137M&L for preparation of newly plastered or unplastered surface of wall surface and applying two coat of cement base paint over one coat of primer complete all as specified and as directed.
138M&L for 20 to 25 mm thick machine in cut kota stone slab flooring over and incl 15mm thick bedding layer CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and mirror/granite finish polishing complete all as specified and as directed. by Engr-in-Charge.
139M&L for pressed steel frame of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed.
140S&F 35mm thick IInd class hard wood plain framed factory made paneled shutters with (2 panel ) of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part-I) kiln seasoned and chemically treated complete all as specified.
141S&F aluminium anodised Bow Handles 150 mm size fixed with machine screws complete all as specified
142M&L for 10mm thick cement plaster in cement mortar (1:3) on concrete roof surfaces finished even and fair, including cleaning the roof top by scraping down with water etc all as specified and as directed.
143M&L for Painting the roof surface with a coat of hot blown paving industrial bitumen 85/25 as a bonding material in two coats one on primed surface & 2nd on APP based polymeric membrane at the rate of 1.20 kg/sqm complete all as specified and as directed.
144M&L for APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3mm thick reinforced with five layer polyster non wove fabric ( wt. Not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified
145Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light and for taking credit of unserviceable light as per Sch of credit and making good disturbed surface of walls, roof, floors etc. with any type of civil work involved complete all as specified and as directed.
146M&L for point wiring for light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes (min 50 mm deep and 1.6 mm thick sheet) duly painted with anti-corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed. by Engineer-in-Charge
147Ditto all as per srl item No.146 above, but for one Fan point controlled by one switch complete all as specified
148Ditto all as per srl item No.146 above, but for one socket outlet 5 Amps on independent board complete all as specified.
149Ditto all as per srl item No.146 above, but for one socket outlet 5 Amps on the same board controlled complete all as specified.
150Ditto all as per srl item No.146 above, but with 2.5 Sqmm (nominal area) FRLS copper cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and as directed. by Engineer-in-Charge.
151S&F in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified
152S&F in replacement switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified.
153S&F in replacement socket out let 5 Amp, 5 pin flush type complete all as specified.
154M&L in replacement Socket outlet multi purpose 2 in 1, 5/6 pin, 5 & 15 Amps, flush type complete all as specified.
155S&F in repair for ceiling rose surface type bakelite 65 x 50mm, three terminal complete all as specified.
156S&F in repair for batten holder insulated body with matching colour back plate all as specified and as directed.
157S&F five step fan regulator, electronic type, single phase, including connection complete all as specified.
158Taking down and refixing carefully ceiling fan of any sweep, any size/make painting of fans complete (as per previous colour),with synthetic enamel paint by spraying including filling cavaties with filler one coat after cleaning all dust etc. including replacement of flexible wire, rubber reel, nut, bolts, split pin all as specified and as directed.
159M&L for Hanging only/ fixing only ceiling fan 1200mm/1400mm sweep after repair & maintenance upto any height upto 5 Mtr complete incl making electric connections, testing complete all as specified and as directed.
160M&L for cutting holes for exhaust fan of size 300 mm dia sweep in brick walls built in cement mortar or cement lime mortar and stone walls built inline mortar for inserting holdfasts and making good dismantled portion in cement mortar 1.3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and as directed.
161S&F LED lamp 9 watt B22 W complete all as specified and as directed. by Engineer-in-Charge
162S&F LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and as directed. by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : greater than 90 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
163S&F LED light fitting mirror type with high out put diffuser 9/10 Watt 220 V AC decorative type including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
164S&F LED light fitting 1 x9/10 watt LED bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
165S&F energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and as directed. by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)(q)LED source : Hi power LED 3 to 5W High power type
166M&L in replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 2.5 Sqmm drawn through in and including PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 2.5 Sqmm complete with any type of civil work involved to make good disturbed surfaces all as specified.Note : Two run of 2.5 sqmm wire and one run of 2.5 sqmm wire as earth wire including PVC concealed conduit shall be measured as one unit
167M&L in replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4 Sqmm drawn through in and including PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm complete with any type of civil work involved to make good disturbed surfaces all as specified.Note : Two run of 4 sqmm wire and one run of 4 sqmm wire as earth wire including PVC concealed conduit shall be measured as one unit
168S&F (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessity complete all as specified and as directed. by Engineer-in-charge.Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ
169S&F (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 4 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessity complete all as specified and as directed. by Engineer-in-charge.Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ
170S&F MCB SPN 40 Amps 240 V, 10 KA, B curve as per complete all as specified and as directed. by Engr-in-charge
171S&F MCB SP 6 to 32 Amps 240 V, 10 KA, B curve as per complete all as specified and as directed. by Engr-in-charge
172S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 16 amp 240 V 10 KA complete all as specified and as directed..
173M& L for XLPE insulated, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete laid in trenches passing through pipes/culverts all as specified and as directed. by Engineer-in-charge.
174M&L for XLPE insulated, PVC sheathed galvanised steel strip or wire , armoured heavy duty 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core complete laid in trenches passing through pipes /culverts all as specified and as directed. by Engineer-in-Charge
175Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe etc and getting out in soft soil, complete all as specified and as directed..
176M&L for returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed..(Surplus soil if any shall not be removed but left over the trench)
177M&L for removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed..
178M&L for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified.Note : For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR part-I
179Supply and laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, compressive strength of brick shall not be less than 75 kg/cm² adjacent/abutting each other complete all as specified and as directed. by Engineer-in-Charge
180M&L for cutting of existing PCC surface any type for laying cables/pipes of size 150mm width and upto 150mm depth complete and repair the surface with necessary cement work, to the disturbed surface to match with existing specifications all as specified and as directed.
181S&F galvanised pipe light grade of dia 50 mm bore for passing of cable fixed to poles/walls/laid under floor complete with and including fittings as required compete all as specified and as directed. by Engr-in-charge.
182M&L for Earthing complete in replacement with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level with the top edge of electrode not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved all as specified and as directed. and testing on completion all as specified and as directed.. Note:- (i) PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.(ii) Earth plate weight will be approved by Engr-in-charge before execution of earth work
183Supply, laying, jointing and testing XLPE insulated, PVC sheathed, Gl strip or wire armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts grade of cross sectional area 10 sqmm 4 core laid in trenches/ducts/through pipes /in floor road/along the pole etc complete all as specified
184M&L for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. (Note: Punned thickness of 18 cm should be considered for payment)
185Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and as directed. by Engineer-in-charge.
186S&F Astronomical Digital timer switch for switching on/off lights according to rising/setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/ or fixed preset time, current capacity 16A, weekly program with 1 changeover (1 CO), Total 28 programs min complete in powder coated CRCA sheet enclosure of suitable thickness with MCB TPN 32 Amp min, 3 pole contactor 32 Amp and MCB for manual switching of lights, fixing arrangement i.e. DIN rail complete with necessary porcelain insulator for incoming and outgoing cable connections with reqd clamp duly painted to fix on pole complete all as specified and as directed.. Make of timer switch: Siemens /Schneider/ L&T/Legrand/Indoasian
187S&F LED Flood light fitting 70 watts, made up of pressure die-cast aluminium housing with toughened glass with mandatory secondary optics lenses, with SS screws, IP-66, luminaire efficacy more than 100 Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF >0.95, LED source: Hi power LED 3 to 5W High power type Fitting should be double driver moisture resistant, with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off >300 V and separate Surge protection device 10 KV complete having fixing bracket clamp all as specified by Engr-in-charge
188S&F junction box for LED bollard/street/security light made out of polycarbonate with glass fibre reinforced and size should not less than 205mm x 255mm x 112mm, IP 66 suitable for upto 25 sqmm cable with cable terminal plate, necessary fixing accessories i.e. clamps, nut and bolts complete all as specified and as directed.
189S&F submain wiring with two single core 1.5 sqmm FR PVC insulated copper cable, unsheathed conductor drawn into PVC conduit and all necessary fittings including 1.5 sqmm multi strand FR PVC insulated copper wire for earth continuity conductor connected to common earth dully completed all as specified and as directed.
190S&F double string wall fan with 400mm sweep. Rated voltage shall be 220-230 Volts. Rated frequency shall be 50 Hz. Rated power input shall be 60W. RPM shall be 1350+/-10%. Rated air delivery shall be 65 CMM. Motor used shall be Class I, permanent capacitor single phase induction motor complete all as specified
191M&L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and as directed. at site. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56138492
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.43 Lakhs
LAST DATE 13-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Bldg No P-175, 176 (Guard Room) And Main Gate Of Harbaksh Dwaar And Other Sanctioned Works Under Age B/R-Ii Of Ge (E) Jrc (Tender Id No 2026_Mes_764289_2)
Basic Detail
Tender No GE/JULL/ET-03/2026-27
Bidding Type Tender
Location
City Jalandhar
State Punjab
Key Dates
Publish Date 06 Jul 2026
Submission Date 13 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 47.43 Lakhs
Tender Fee 500
EMD 94860
Exemption Available
Document List
BOQ_866890.xls
d5cb7232-5517-497e-945e-6e5038f21b7f.html
Tender03.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_866890.xls

html

d5cb7232-5517-497e-945e-6e5038f21b7f.html

pdf

Tender03.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders