| 1 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 2 | M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 Complete all as specified and as directed. |
| 3 | Taking down cement plaster on brick or stone walls etc. including raking out joints hacking for key scrubbing down with water complete all as specified and as directed. |
| 4 | M&L rendering 15 mm thick in cm 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 5 | M&L rendering 15 mm thick in cm 1:4 on stone masonry surfaces or surfaces other than fair faces of brick work or concrete surfaces mixing of integral water proofing compound as per manufacture instruction by weight of cement finished even and smooth without using extra cement.(Note : Supply only wpc shall be measured & paid separately) |
| 6 | Supply only liquid water proofing compound complete all as specified and directed. |
| 7 | M&L for rendering 5 mm thick in C M 1:3 on ceiling and finished the surface even and smooth without using extra cement complete all as specified . |
| 8 | M&L for preparation of newly plastered or un plastered surfaces of walls and applying 3mm thick Jk/birla wall care putty on internal surfaces of walls, rubbing with sand paper to achieve a level and smooth surface including two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed. |
| 9 | M&L for preperation of newly plastered surfaces of wall es etc and applying two coats of exterior emulsion paint in camouflage pattern (two or more colour combination)over 1mm thick cement based putty complete all as specified and directed . |
| 10 | M&L for complete removal of existing treatment by scrapping, washing, rubbing down & stopping etc of old painted surfaces and applying two coat of exterior emulsion paint camoflague pattern through OEM complete all as specified and directed. |
| 11 | M&L for preparation of old painted wooden surface of wood and wood based material over 10cm in width or girth of any description and applying one coat of synthetic enamel paint all as specified and directed. |
| 12 | M&L for preparation of old painted surface of steel or iron work over 10cm in width or girth of any description and applying two coat of synthetic enamel paint all as specified and directed. |
| 13 | M&L for preperation of newly plastered surfaces of wall es etc and applying two coats of exterior emulsion paint in camouflage pattern (two or more colour combination)over 2mm thick cement based putty complete all as specified and directed . |
| 14 | M&L for one coat of exterior emulsion paint over old decorated surface of wall including preparation of surface complete all as specified and as directied. Note:- Cost of scaffolding and its removal is deemed to be included in unit rate quoted. |
| 15 | M&L complete removal of existing treatment by scrapping, washing, rubbing down & stopping etc of old painted surfaces and applying two coats of exterior emulsion paint on walls complete all as specified and as directed. Note:- “The rates for external painting are deemed to include all operations for execution up to 15.00 m height above ground level, including provision of scaffolding, staging, labour, T&P, and safety precautions. No additional claim on account of height up to 15.00 m shall be entertained.” |
| 16 | M&L for preperation of old painted surfaces of wall by scrapping, washing, rubbing down & stopping etc of old painted surfaces and applying one coat of exterior emulsion paint in camouflage pattern through OEM (two or more colour combination) complete all as specified and as directed.Note:- “The rates for external painting are deemed to include all operations for execution up to 15.00 m height above ground level, including provision of scaffolding, staging, labour, T&P, and safety precautions. No additional claim on account of height up to 15.00 m shall be entertained.” |
| 17 | M&L for complete removal of existing treatment by scrapping, washing, rubbing down & stopping etc of old painted surfaces and applying two coat of exterior emulsion paint camoflague pattern through OEM complete all as specified and directed.Note:- “The rates for external painting are deemed to include all operations for execution up to 15.00 m height above ground level, including provision of scaffolding, staging, labour, T&P, and safety precautions. No additional claim on account of height up to 15.00 m shall be entertained.” |
| 18 | M&L for preparation of old painted steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint in camouflage pattern complete all as specified and as directed by Engr-in-Charge. |
| 19 | Demolition floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed. |
| 20 | M&L Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick cement plaster in CM 1 :4 complete all as specified and directed. |
| 21 | M&L for joint free non-skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1 :6 complete all as specified and directed. |
| 22 | S&F Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 20mm thick screed bed in CM 1 :4 complete all as specified and directed. |
| 23 | M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed. |
| 24 | M&L PCC 1:3:6 type C2, 75 mm thick laid as in plinth protection/paving etc finished even & smooth with out usnig extra cement complete all as specified and as directed. |
| 25 | Demolition of cement concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 26 | M&L Hardcore of broken stone gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as dierected. |
| 27 | M&L for 100 mm thick cement concrete type D-2, 1:4:8 using (40mm graded aggregate) complete all as specified and directed. |
| 28 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approvedcolour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 29 | M&L cement concrete 1:2:4 type B1 using 20 mm graded aggregate as in flooring benching to drain, coping, bed block etc and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and directed. |
| 30 | S&F 15 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors or concealed including taking up or down steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 31 | S&F 20 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors or concealed including taking up or down steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 32 | S&F 25 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors or concealed including taking up or down steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 33 | S&F in repair vitreous china flat back white WHB size 550 X 400 mm including fixing of brackets with wooden plugs and bolts etc, and waste pipe including fixing of 15 mm bore CP Brass pillar tap fancy type long shang making good etc complete all as specified and directed. |
| 34 | Taking down unserviceable PVC low level flushing cistern and supply and fixed new PVC valveless ,symphonic action type flashing cistern white with inlet ,bal valve ,float and handle incluiding brackets-10 ltr capacity complete all as specified and directed. |
| 35 | S&F in repairs Chromium Plated Jet Spray/Health faucet with 1.0 mtr 15mm bore PVC Tube and hooke all as specified and directed. |
| 36 | S&F in repairs two way bib cock 15 mm chromium plated complete all as specified and directed. |
| 37 | S&F in repairs angular stop cock chromium plated 15 mm dia complete or as specified and directed. |
| 38 | Supply and fix in repair 15 mm bore CP bib taps cast copper alloy with crutch or butterfly handles screwed down for iron pipes all as directed complete. |
| 39 | S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 40 | S&F in repair PVC (SWR) pipes single socketed of any length with rubber rings joints 110mm dia fixed to walls complete all as specified and directed |
| 41 | S&F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall for 110/75mm dia pipe complete all as specified and as directed. |
| 42 | S & F in repairs 20mm bore dia Gate valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for union, complete all as specified and directed. |
| 43 | Dismantling water tanks and supply and fixed rotational moulded polythene water storage tank (Cylinderical vertical with closed top)hoisted and fixed in position and connecting the inlet and out let pipe etc complete 1000Ltr capacity complete all as specified and directed. |
| 44 | Dismantling water tanks and supply and fixed rotational moulded polythene water storage tank (Cylinderical vertical with closed top)hoisted and fixed in position and connecting the inlet and out let pipe etc complete 500 Ltr capacity complete all as specified and directed. |
| 45 | S&F in repair plates (plain or chequered) channels, square cut or notched(ordinary and counter sunk) forming holes, without any attachment Fe 410 -W(Gde-E- 250) quality- A complete all as specified and directed. |
| 46 | Taking down chawkhats or frame with shutter (without taking out shutter from the frame not exc1.50 Sqm each complete all as specified and directed. |
| 47 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube suppling and fixing in opening as per specification and drawing complete all as specified and directed. |
| 48 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 49 | S&F aluminium, anodized, barrel tower bolts 150mm of extruded section complete all as specified and directed. |
| 50 | S&F 100 mm anodised extruded aluminium alloy butt hinges with galvanised mild steel hinge pin, 100mm size all as specified and as directed. |
| 51 | S&F 100mm size handles of stainless steel fixed with screws complete all as specified. |
| 52 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with bead complete all as specified and directed. |
| 53 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each panel complete all as specified and directed. |
| 54 | S&F in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed. |
| 55 | M&L for repair to RCC chajja/facia/fins, roof projection by removing loose concrete including cleaning of exposed reinforced with wire brush and cutting/removing of rusted unsericeable reinforcement if any and providing new reinforcement inserting/welding or binding of reinfoced , applying a coat of forsect chemical - Nito bond ( for bonding of old & new cone) and provn of RCC 1:2:4 type B0, finishing surface even and smooth with applying 2 coats of Cement base paint over a coat of primer complete all as specified and as directed. (Note : formwork or scafolding as required at site deemed to be included in the rate.) Please Enable Macros to View BoQ information |
| 56 | M&L for repair to RCC chajja/facia/fins, roof projection by removing loose concrete including cleaning of exposed reinforced with wire brush and cutting/removing of rusted unsericeable reinforcement if any and providing new reinforcement inserting/welding or binding of reinfoced , applying a coat of forsect chemical - Nito bond ( for bonding of old & new cone) and provn of RCC 1:2:4 type B0, finishing surface even and smooth with applying 2 coats of Cement base paint over a coat of primer complete all as specified and as directed. (Note : formwork or scafolding as required at site deemed to be included in the rate.) Please Enable Macros to View BoQ information |