Tender For Provn Of Solid Waste Management Infrastructure At Hisar Mil Stn
Tender Value
4 Crore
Estimated cost
Bid Submission
28 Jul 2026
21 days left
EMD
4.75 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Solid Waste Management Infrastructure At Hisar Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Schedule \\"A\\" \\"BUILDING WORKS\\" PART IA is not prepriced by MES and prepriced rate indicates 0.0 under Column 5 signifies this fact only.Design, fabrication, erection and construction of PEB structure of clear span (27mX37m) and height 7m with corrugated colouired roof sheeting including brick wall of height 1.5m on the all sides with PCC flooring and 03 Nos MS gates complete all as specified and as shown in drawings |
| 2 | Lump sum price worked out by the contractor for \\"BUILDING WORKS\\" as listed in Schedule ‘A’ Part-I B representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 3 | Lump sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 4 | Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 5 | Lump sum price worked out by the contractor for \\"ROAD, PATH, CULVERT AND HARD STANDING\\" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 6 | Lump sum price worked out by the contractor for \\"SEWAGE DISPOSAL\\" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 7 | Lump sum price worked out by the contractor for \\"FENCING AND GATE \\" as listed in Schedule ‘A’ Part-VI\\" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 8 | Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 9 | Lump sum price worked out by the contractor for \\"EXTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 10 | Lump sum price worked out by the contractor for \\"SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK\\" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 11 | Sch 'A' Part-X MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-IX SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule). |
| 12 | INTERNAL ELECTRIFICATIONS&F for modular type 1 blanking plate etc complete all as specified and directed |
| 13 | S&F for LED industrial lighting 120 Watt round higbay in PDC housing suitable for industrial application and efficacy up to 130 to 150 LPW, SPD included, IP 65 with necessary fixtures required for mounting the light, suitable brackets, nuts, bolts and fixing PVC conduit for cable/ wire protection upto PVC terminal box etc complete all as specified and directed |
| 14 | SEWAGE DISPOSALS&F for factory made (SFRC) precast reinforced cement concrete manhole cover as required thickness not less than 60mm of size 1200mm x 600mm, edge of manhole cover to be locked with 1mm thick MS sheet etc complete all as specified and directed. |
| 15 | S&F for On site Hume Pipe (for 10 users) septic tank designed to carry sewage and sullage water, exacation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 16 | S&F for On site Hume Pipe (for 10 users) septic tank designed to carry sewage and sullage water, exacation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender