| 1 | Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5m in depth for foundation, shaft, manholes etc and n exc 10sqm on plan and getting out in any type of soil complete all as specified and directed. |
| 2 | All as per Sl item No. 1 above but depth exc 1.50 m but not exc 3.00 m complete all as specified and directed. |
| 3 | Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm as specified in soil complete all as specified and directed. |
| 4 | Removing excavated materials n.exc 50 mtr and depositing where directed at level n.exc. 1.50 mtr above the starting point complete all as specified and directed. |
| 5 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 6 | M&L PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 7 | M&L for 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in below of DWCPE pipe line as a bed and provide required slope complete all as specified and directed. |
| 8 | Demolition of brick work built in cement mortar including plaster, coping etc of manholes /septic tank in any position complete all as specified and directed. |
| 9 | M&L brick work with sub class-B bricks straight or curved on plan exceeding 6 mtr mean radius built in CM 1:4 complete all as specified and directed. |
| 10 | M&L brick work in CM (1:4) except bricks (Old retrieved good quality bricks to be use) straight or curved on plan exceeding 6 mtr mean radius complete all as specified and directed. |
| 11 | Taking down cement plaster any description including raking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 12 | M&L 15mm thick rendering on brick surfaces of wall in CM 1:4 finished even and smooth without using extra cement including mixing of WPC compound complete all as specified and directed.Note : WPC shall be measured and paid separately. |
| 13 | M&L fo preparation of newly plastered surface of walls and applying two coats of cement based paint over a coat of white wash complete all as specified and directed. |
| 14 | Demolition and breaking up drain pipes of internal dia 150 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar or cement concrete complete all as specified and directed.Note : Earth work shall be measured and paid seperately |
| 15 | Demolition and breaking up drain pipes of internal dia 200 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar or cement concrete complete all as specified and directed.Note : Earth work shall be measured and paid seperately |
| 16 | Supply and laying DWCPE (SN8) 180 (OD)/163 (ID) mm diameter drain pipes as per IS-16098 (Part-II), laid in trenches on PCC bed to required slope, including all accessories/fittings, jointing and tested complete all as specified and directed.Note : PCC and earth work shall be measured and paid separately. |
| 17 | Supply and laying DWCPE (SN8) 240 (OD)/200 (ID) mm diameter drain pipes as per IS-16098 (Part-II), laid in trenches on PCCbed to required slope, including all accessories/fittings, jointing and tested complete all as specified and as directed.Note : PCC and earth work shall be measured and paid separately. |
| 18 | M&L PCC 1:2:4 type B1 using 20mm graded stone aggregates for coping & benching to main holes etc complete all as specified and directed. |
| 19 | Material and labour for cleaning of blockage of bathroom, kitchen, urinals and WHB at any location, at any height, at any floor by cleaning the nahani traps/ gully traps by rodding/choke remover, manually or other wise including refixing of oval assess door covers with nuts & washers, including removing of all extracted wastes solid or liquid sludge any distance outside the cantonment area complete all as specified and directed. |
| 20 | Material and labour for cleaning of blockage of WC (any type) including cleaning of SGSW/CI pipe of any lenght upto 1st manhole by rodding choke remover, manually or otherwise including refixing of assess door covers with nuts & washers, including removing of all extracted waste solid or liquid sludge to any distance outside the cantonment area complete all as specified and directed. |
| 21 | Material and labour for cleaning of Manholes including taking off manhole cover, closing of inlet/ outlet of manhole/line and cleaning of manholes of any size n exc 1.0 sqm and depth up to 2m, using mechanized suction machine and removing of all wastes solid or liquid sludge in closed containter to any distance outside the cantonment area and replacing manhole cover in position after cleaning complete all as specified and as directed. |
| 22 | Material and labour for cleaning of Manholes including taking off manhole cover, closing of inlet/ outlet of manhole/line and cleaning of manholes of any size n exc 2.0 sqm and depth exc 2m but n exc 5.0m, using mechanized suction machine and removing of all wastes solid or liquid sludge in closed containter to any distance outside the cantonment area and replacing manhole cover in position after cleaning complete all as specified and as directed. Note for sl item No. 21 & 22 : (a) Contractor shall make his own arrangement for disposal off the sludge and no extra cost for the same shall be paid by the department (b) The manhole once cleaned, shall be kept functional through out the contract period. In case the manholes required to be cleaned again, same shall be done by the contractor at his own cost and no repitative payment shall be allowed for the same manhole (c) Any damaged caused during cleaning shall be made good to the entire satisfaction to Engineer-in-charge by the contractor without any extra cost. |
| 23 | M & L for cutting bushes around the manholes and on the route of sewer line and refixing manhole cover properly complete all as specified and directed. |
| 24 | M&L for cleaning of underground SGSW/DWCPE/SN2 sewage pipes (cleaning of pipe length from manhole to manhole or from manhole to septic tank) by using mechanised suction machine for sewage pipe lines of any size and depth up to 1.50m complete all as specified and directed. |
| 25 | M&L for cleaning of underground SGSW/DWCPE/SN2 sewage pipes (cleaning of pipe length from manhole to manhole or from manhole to septic tank) by using mechanised suction machine for sewage pipe lines of of any size and depth exc 1.5 m below complete all as specified and directed. Note for sl item No. 24 & 25: (a) Cleaning of manholes if reqd shall be measured and paid seperately. (b) Any damage caused during cleaning shall be made good to the entire satisfaction to Engineer-in-charge by the contractor without any extra cost. (c) Once cleaned the sewage lines, the contractor shall maintain the lines funtional upto date of completion. |
| 26 | Supply and fixing in repairs cast iron acces door cover for 75mm bore pipes including all accesseries complete all as specified and directed. |
| 27 | Supply and fixing in repairs cast iron acces door cover for 100mm bore complete all as specified and directed. |
| 28 | S & F in repair cast iron bends (any radius) with Ducks foot or heel rest bend of 100mm bore dia complete all as specified and directed. |
| 29 | S & F in repair cast iron bends (any radius) with Ducks foot or heel rest bend of 75 mm bore dia complete all as specified and directed. |
| 30 | M & L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branche channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 20mm graded crushed stone aggregate smooth finished and forming benching as required, Internal dia of pipe 150 mm complete all as specified and directed. |
| 31 | M&L for precast cement concrete 1:2:4 Type B1 as in cover slabs (for manholes etc) and similar articles with plain & smooth faces and set in cement mortar (1:4) complete including dismantling existing damaged manhole covers of any description & in any position all as specified and directed. (Note : The rate quoted shall be deemed to include use and waste of necessary form work) |
| 32 | M & L mild steel TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed. |
| 33 | Supply & fixing in repairs 110mm PVC pipes grade 'B' bends / Elbow heavy grade of any radius/shoe with or without access door fixed to uPVC pipes complete all as specified and directed. |
| 34 | Supply & fixing in repairs 75mm PVC pipes grade 'B' bends / Elbow heavy grade of any radius/shoe with or without access door fixed to uPVC pipes complete all as specified and directed. |
| 35 | Supply & fixing in repairs PVC 75mm dia of floor trap with grating including jointing to waste pipes fixed in cement concrete 1:2:4 type B1 in repair complete all as specified and directed. |
| 36 | Supply & fixing in repairs PVC pipes grade 'B' branch piece, (single Y ), 75mm bore (equal or unequal), with or without access to door complete all as specified and directed. |
| 37 | Supply & fixing in repairs PVC pipes grade 'B' branch piece, (single Y ), 110mm bore (equal or unequal), with or without access to door complete all as specified and directed. |
| 38 | Supply & fixing in repair PVC pipes grade 'B' vent cowl 110mm complete all as specified and directed. |
| 39 | S & F in repairs 100 mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed In walls complete all as specified and directed. |
| 40 | S & F in repairs 75 mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed in walls complete all as specified and directed. |
| 41 | S & F in repairs Vitreous china wash down water closet pan (pedestal pattern), white (including sheet cover, fixing bolts, flushing cistern, & flush pipe) complete all as specified and directed. |
| 42 | S&F repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot rests Incl flushing cistern , 'P' trap set in and including concrete fixed complete all as specified and directed. |
| 43 | Water proofing treatment to sunken slab and adjjoining vertical surfaces complete all as specified and directed by Engineer-in-charge as under :-(a) M&L rendering 10 mm thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compound trowel even and smooth with steel trowel on sunken surfaces (b) Applying first coat of chemical pidifin 2K(Dr Fixit) on cleared RCC surfaces @ 0.86 Kg/Sqm (Minimum) as recommended by manufacturer.(c) Provide a layer glass fibre mesh of size 2.25mm x2.25mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturers recommendation.(d) Applying second coat of chemical Pidifin 2K (Dr Fixit) @ 0.86 Kg/Sqm (minimum) layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturers. |
| 44 | M&L for PCC 1:5:10, type E-2 as in filling of sunken floors etc complete all as specified and directed. |
| 45 | M&L 40 mm GI pipe light grade, made to shape as in spout pipe in sunken/ verandah/ Balcony complete all as spedifed. |
| 46 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises all as specified and as directed. |
| 47 | M&L for Non skid coloured ceramic tiles (Joint less) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n exc 0.18 as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed |
| 48 | M&L for ceramic glossy finish, joint free premium quality coloured tiles 600 X 300 mm and 8-9 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 49 | M & L for desludging by removing semi solid sludge from existing spectic tank, soak wells of any capacity and depth as in foul condition including taking up and placing in position manhole cover of any description, removal of sludge and solid contents to any place outside defence land (in covered septic tanker) complete all as specified and directed.Note : Contractor shall be responsible for providing necessary safety eqpt to the labour. |
| 50 | M & L for dewatering from existing septic tanks and soak wells and disposal of effluent out side MD land (In covered safety tankers) complete all as specified and directed. |
| 51 | S & F in repairs FRP manhole covers, frame and grating havingany shape for manhole covers and installed as per manufacturer instruction. The top layer of covers, frame, and grating consists of special grade of UV stabilised resin to get good abrasion resistance. The fibre glassshall be reinforced with glass fibre film in the film of UD stitched, multidirectional wooden roving to get good tensile and flexural strength and embedded in the matrix of UV stablised and high tensile strength modified specially to suit this application. The frame shall be embedded in minimum 1:2:4 concrete and top level of frame to match the existing level complete all as specified and directed. |
| 52 | S&F in repairs for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. Please Enable Macros to View BoQ information |